• Title/Summary/Keyword: diesel generator set

Search Result 28, Processing Time 0.028 seconds

Vibration characteristics of diesel generator set with resilient mount and prevention of vibration on the design stage (탄성 마운트 장착 디젤 발전기 세트의 진동 특성과 예방에 대한 연구)

  • Lee, Kun-Hee;Bae, Jong-Gug;Lee, Soo-Mok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.921-924
    • /
    • 2005
  • Diesel generator sets with resilient mounts often experience resonances by major excitations which come from diesel engine and their foundation with rigid body modes. Because their natural frequency is determined by moment of inertia and stiffness of resilient mount vibration problems are resolved by changing location and stiffness of resilient mounts. But the calculated natural frequencies are inaccurate due to uncertainty of the inertia and mount stiffness. So this result can be useless on the design stage. In this paper, the stiffness of mount is evaluated on result from mount stiffness test in laboratory and generator set vibration test and a simple calculation method for moment of inertia is proposed. Based on these data, the procedure to select optimized mount stiffness and location on the design stage is set up.

  • PDF

A study on the design optimization of baseframe to avoid resonance of diesel generator set (발전기세트 공진 회피를 위한 베이스프레임 최적설계에 관한 연구)

  • Jeong, S.H.;Kwak, Y.S.;Kim, W.H.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.157-162
    • /
    • 2012
  • A structural modification of baseframe is an effective method to avoid resonance in marine diesel generator (D/G) set which consists of diesel engine, generator and baseframe. However the reinforcement with thick plates or additional parts to increase the natural frequency can be less effective because of increased weight. Especially fine control of target mode based on the experience is difficult because the weight and interference of system have to be considered. In this paper, the design optimization of baseframe was performed to reduce the resonant vibration using a gradient descent method. The design parameters such as thickness, shape and location of baseframe parts are optimized to increase the torsional natural frequency of D/G set. From the actual test, the new designed baseframe reduced the vibration level in resonance by 55% without any increase of weight and interference. interference.

  • PDF

A Study on the Analysis of Failures Related to Emergency Diesel Generators in Overseas Nuclear Power Plants (원전용 비상디젤발전기 국외 손상사례 분석에 관한 연구)

  • Chang, Jung-Hwan;Kim, Jin-Sung;Chung, Hae-Dong;Cho, Kwon-Hae
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.5 no.1
    • /
    • pp.32-37
    • /
    • 2009
  • The emergency diesel generator (EDG) in a nuclear power plant (NPP) shall start within 10 secondss and supply electrical power to engineered safety features within one minute and less if a loss of offsite power (LOOP), A design-basis event, or their combination occur. Each NPP has an EDG set consisting of two diesel generators for redundancy. In addition to the EDG set, an alternate Alternating Current Diesel Generator (AAC DG) is installed and shared by several units to cope with a station black out (SBO), i.e., loss of the offsite power concurrent with reactor trip and unavailability of the EDG set. The objective of this study is to analyze the failure data of emergency diesel generators reported in overseas nuclear power plants.

  • PDF

The Fundamental Study for Torsional Vibration of Diesel Generator Set connected Electric Power Grids (전력망에 연결된 디젤 발전기 세트의 비틀림 진동에 대한 기초 연구)

  • Kim, Hyujung;Yun, Hyunwoo;Barro, Ronald D.;Lee, Donchool
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.294-297
    • /
    • 2014
  • A Shipboard power system consists of three or four diesel generator sets connected to a grid. In case of dual fuel diesel generator sets employed LNG ship as a prime mover, large amounts of electricity are required for electric propulsion, auxiliary machinery and accommodation facilities. The electrical connection between generators through a network, torsional vibration can lead power swings. In this paper, the influence on the network by the torsional vibration of diesel generator sets in grid operation were studied. The torsional vibration characteristics were investigated and analyzed through theoretical analysis and the vibration measurement and the results were presented.

  • PDF

Analysis and Prediction of Structural Vibration for Diesel Engine Generator Set (디젤 발전기세트의 구조진동특성 연구)

  • 이수목;김관영;김원현
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.948-954
    • /
    • 2002
  • The structural vibration of a diesel generator set was investigated through analyses and tests. FE modeling and normal mode analysis were performed and compared with measured results for both structure components and generator set assembly. The results of component analyses were fairly well coincident with measured results but those of assembled generator set showed more or less discrepancies. Discussions were given about the uncertainties for vibration characteristics of component structures and assembled running structures especially concerning their nonlinearities and damping effects. Detailed excitation analysis fellowed by forced response analysis was done from the engine and pressure data to compare with the actual measured vibration. As results the vibration prediction for frame structures of reciprocating internal combustion engine was confirmed reliable to some extent.

  • PDF

Development of stiffness adjustable mount for vibration control of marine diesel generator set (박용 발전기세트 진동 제어를 위한 강성 조절형 마운트 개발)

  • Kim, W.H.;Joo, W.H.;Kim, D.H.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.89-92
    • /
    • 2012
  • Marine diesel generator(D/G) set which is supported with resilient mounts for vibration isolation has been experienced the resonance problem by the main engine or propeller excitations and rigid body modes. Then the avoidance of resonance is difficult because the several excitations and 6 rigid body modes have to be considered simultaneously. In this paper, stiffness adjustable mounts was developed and proposed to control the natural frequencies of installed D/G set. Operating concept of the mount is that the total stiffness of mount can be changed according to the engagement of secondary rubber element in addition to primary one. The performance of mount was verified with the test rig and actual experiment in D/G set.

  • PDF

Development of MR Mount for Vibration Control of Marine Diesel-Generator Set (박용 발전기세트 진동 제어용 MR 마운트 개발)

  • Kang, Ok-Hyun;Kim, Won-Hyun;Joo, Won Ho;Park, Jun-Hee
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.04a
    • /
    • pp.381-385
    • /
    • 2014
  • This paper investigates the magneto-rheological(MR) mount for the marine diesel-generator(D/G) sets. Sometimes, significant vibrations over the allowable limit are observed on the D/G sets due to their huge excitation forces. Because the severe vibration can lead to structural damages to the D/G sets, it should be reduced below the limit. Although passive mounts with rubber isolators are usually used, the vibration reduction performance is not always sufficient. In addition, expecting that the vibration levels required by customers will get more severe, vibration reduction devices need to be developed. To the aim, the flow mode type of MR mount has been designed. Especially, the annular-radial configuration was adopted to enhance the damping force within the restricted space. The geometry of the mount has been optimized to obtain the required damping force and the magnetic field analysis has been carried out using ANSYS APDL. To verify the performance of the developed MR mount, an excitation test was conducted. In addition, they were applied to a medium-speed diesel generator and it was verified that about 40% of vibration reduction was yielded.

  • PDF

Vibration characteristics and reduction of Diesel Power Plant(DPP) (육상용 중속 디젤엔진 발전기세트의 진동 특성 및 저감)

  • Kim, Won-Hyun;Jung, Kun-Hwa;Lee, Soo-Mok;Ryoo, Young-Seok
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.39-40
    • /
    • 2006
  • Diesel power plant(DPP) with the medium speed diesel engine is operated under the very severe condition in aspect of load and operating time as compared with the marine diesel generator set. So, minimized vibration level have to be insured for the more stable operation of engine and generator. The vibration of generator set mainly comes from the resonance between the rigid modes by resilient mount or distortion modes by structural stiffness and the excitation forces of engine. Then, avoidance of resonance with structural modification is generally well known. In this paper, the first order vibration in non-resonance range and local vibration modes were investigated by impact test, response/ODS(operational deflection shape) measurement and 3D finite element analysis for the additional reduction of vibration. The proposed countermeasures were actually applied and their final effects were verified through the in-situ measurement.

  • PDF

The Study on the Improvement on Damping Ratio of Dynamic Absorber using Silicon Oil (실리콘 오일을 이용한 동흡진기 감쇠 성능 향상에 대한 연구)

  • Kwak, Y.S.;Kim, W.H.;Joo, W.H.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.113-118
    • /
    • 2011
  • Many kinds of dynamic absorbers have been used to reduce the vibration of machineries and structures. In the typical ones, however low damping capacity, durability and limited install condition restrict their application. In this study, high damped dynamic absorber was proposed for diesel generator set. Developed absorber is composed with mass and coil springs. Silicone oil was filled inside the narrow gap between mass and casing. Viscous damping of silicon oil act as additional damping so that proposed dynamic absorber is suitable for D/G set which have adjacent resonance frequency to operation speed. The performance of the dynamic absorber was confirmed through the actual test on diesel engine generator set.

  • PDF

DESIGN, CONSTRUCTION AND ACOUSTIC PERFORMANCE OF A SOUND-POOOF ENCLOSURE FOR DIESEL GENERATOR-SET

  • Bansal, A.S.
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1994.06a
    • /
    • pp.662-667
    • /
    • 1994
  • This paper presents the design and construction details of a soundproof enclosure for housing 20 KVA diesel generator-set. As the generator had to be installed close to the hospital building, it was desirable to reduce the transmission of noise by housing the generator in such an enclosure. The diesel engine being an air cooled one, it was essential to supply fresh air into the enclosure for its cooling. Forced inflow of air is provided through an inlet duct located in such a way that the incoming fresh air is thrown close to the inlet of cooling fan of the engine. The high velocity air stream, which heats up while passing over the engine head, escapes to the atmosphere through a rectangular outlet duct with enlarges inlet that receives hot air from the engine. The air ducts were designed specially and have been provided with acoustic lining for sound absorption. The masonary enclosure has been provided with double glazed fixed windows and double doors. The exhaust pipe of the engine fitted with a muffler has been taken out through the enclosure wall facing away from the hospital. Acoustic performance studies conducted in terms of attenuation provided by the enclosure at different frequencies have also been presented and discussed. The noise control measures adopted for building the sound-proof enclosure have been found to be quite effective as the noise levels inside the hospital building are now within the acceptable limits.

  • PDF