• Title/Summary/Keyword: diagnostic radiology

Search Result 2,281, Processing Time 0.033 seconds

Effect of Radiation Dose for Radiotherapy on Ovarian Follicle Atresia in Rat (치료 방사선량이 쥐의 난포 퇴축에 미치는 영향)

  • Lee, Won-Jeong;Seon, Jong-Ryul;Yoo, Se-Jong;Ahn, Bong-Seon
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.4
    • /
    • pp.208-212
    • /
    • 2012
  • In previous studies, ovarian follicle in rat has been used a higher radiation dose than that for cancer radiotherapy in clinical practice. The aim of this study was to evaluate the effect of radiation dose used for cancer radiotherapy on ovarian follicle atresia in rat. Mice of 4-week-old female were whole body irradiated with 2 cGy or 2 Gy (Mevatron 67, Siemens, Germany) and sacrificed by cervical dislocation. Ovaries were collected at 24 hours after irradiation to observe the degree of follicular atresia. Ovaries were fixed in neutral formaldehyde solution for 24 hours and embedded with paraffin. Cutted in $5{\mu}m$ thickness with microtome and stained with hematoxylin and eosin (H&E) and TUNEL immunohistochemical stain, and examined histologically under a light microscope. All data were presented as mean ${\pm}SD$, calculating the ratio of normal or atretic follicles to total ovarian follicles. Statistical analysis was performed by the Mann Whitney test using the SPSS ver 19.0. Ratio of atretic to total follicles of 2 Gy group was significantly higher than control or 2 cGy groups (p<0.05). Ratio of normal to total follicles of 2 Gy group was significantly lower than control group in preantral follicle (64.0 vs. 87.7, p=0.027). Ratio of normal to total follicles of 2 cGy group was significantly increased more than control or 2 Gy groups in antral follicle, and there were no significant difference between control and 2 Gy groups (p=0.522). Radiation dose of 2 Gy for cancer radiotherapy have a significant effect on ovarian follicle atresia in rat.

Evaluation of the Solitary Pulmonary Nodule by Spiral Computed Topography with Contrast Enhancement (고립성 폐결절의 감별에 있어서 나선형 흉부 전산화 단층촬영시 조영증강의 의의)

  • Song, Kwang Seon;Shin, Kye Chul;Yong, Suk Joong;Ryu, Jeong Seon;Kang, Sin Goo;Kim, Chong Ju;Sung, Ki Joon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.4
    • /
    • pp.519-526
    • /
    • 1996
  • Background : Clinical and Radiographic studies to differentiate benign from malignant pulmonary nodules have previously focused on clinical status and the morphologic and the computed tomographic attenuation characteristics of the lung nodules. Distinctive differences in the vascularity and pathophysiology of malignant versus benign pulmonary nodules were identified. We evaluated the diagnostic method for differentiating malignant from benign solitary pulmonary nodule by contrast enhancement on the spiral CT. Method : Sixteen patients with solitary pulmonary nodule were examined(Tuberculoma 8, primary lung cancer 8). Serial thin section on the spiral CT was performed before and after(45second, 2min, 5min) the onset of the injection of 100mL of nonionic contrast material(2mL/sec). Results : There was no difference in size of nodule and pre-contrast CT number (Hounsfield unit) between benign and malignant nodules. At forty-five second after the onset of the injection, malignant neoplasms($19.6{\pm}7.9$ HU) enhanced significantly more than tuberculomas($4.9{\pm}9.4$ HU, p=0.008). At 2minute and 5 minute after, malignant neoplasms($34.0{\pm}19.2$HU, $34.0{\pm}15.4$HU) enhanced significantly more than tuberculomas ($6.7{\pm}9.7$HU, p=0.007 and $7.7{\pm}11.5$HU, p=0.011). On cut-off value 20HU(contrast enhancement) 2minute after the injection of contrast media, sensitivity was 87% and specificity was 87%. No correlation between the contrast enhancement and size of the nodules was observed. Conclusion : Studies with the use of an intravenously administered noniodinated contrast medium in examining the enhancement properties of lung nodules was performed. The contrast enhancement was useful in differential diagnosis of solitary pulmonary nodules.

  • PDF

Constrictive Bronchiolitis Accompanied By Non-Hodgkin's Lymphoma (비 Hodgkin 림프종과 동반된 교착성 세기관지염)

  • Lee, Kye Young;Jee, Young Koo;Choi, Young Hi;Myong, Na Hye;Kim, Keun Youl
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.4
    • /
    • pp.613-622
    • /
    • 1996
  • Constrictive bronchiolitis, one of small airway diseases, is very rare and occupies one of the two arms of bronchiolitis obliterans together with proliferative bronchiolitis. Proliferative bronchiolitis, presenting the prototype with bronchiolitis obliterans with organizing pneumonia(BOOP), can be easily taken into diagnostic consideration in terms of relatively rapid clinical course and radiologic presentation as if atypical pneumonia with interstitial and alveolar infiltrations. Meanwhile constrictive bronchiolitis is not only very Tare but also easily overlooked as chronic obstructive pulmonary diseases such as emphysema, because it usually shows normal chest radiographic finding and obstructive pattern in pulmonary function test. In the aspects of the response to treatment, proliferative bronchiolitis showed dramatic response to the corticosteroid while constrictive bronchiolitis is intractable, which is easily explained on the basis of the pathologic characteristics of cicartrical replacement of bronchiolar walls. The bronchiolitis, both proliferative and constrictive, can be associated with diverse conditions such as inhalational injury, postinfectious process, drug of chemical induced reactions, connective tissue diseases, and organ trasplantation. And there is idiopathic type which has no associated condition. There is one explanation that both types of bronchiolitis lie on the same disease spectrum because the different disease pattern can be evoked from the same etiology. In contrast, another explanation is suggested that both types of bronchiolitis are one of nonspecific tissue reaction rather than a disease specific histologic finding because the various types of causes can provoke the same histologic findings. These dilemma remains for further investigation. With literature investigation, the authors report a case of constrictive bronchiolitis proven by open lung biopsy in 47 year old female who was diagnosed as non-Hodgkin's lymphoma and simultaneously had relatively rapid progression of airflow obstruction and showed negative radiographic finding without the rise factors for the development of chronic obstructive lung disease. We consider it as idiopathic because we could not find any relationship between constrictive bronchiolitis and non-Hodgkin's lymphoma on the literature search and it requires further investigation.

  • PDF

Development of $^{166}Ho$-Stent for the Treatment of Esophageal Cancer (식도암 치료용 $^{166}Ho$-Stent 개발)

  • Park, Kyung-Bae;Kim, Young-Mi;Kim, Kyung-Hwa;Shin, Byung-Chul;Park, Woong-Woo;Han, Kwang-Hee;Chung, Young-Ju;Choi, Sang-Mu;Lee, Jong-Doo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.1
    • /
    • pp.62-73
    • /
    • 2000
  • Purpose: Esophageal cancer patients have a difficulty in the intake of meals through the blocked esophageal lumen, which is caused by an ingrowth of cancer cells and largely influences on the prognosis. It is reported that esophageal cancer has a very low survival rate due to the lack of nourishment and immunity as the result of this. In this study a new radioactive stent, which prevents tumor ingrowth and restenosis by additional radiation treatment, has been developed. Materials and Methods: Using ${\ulcorner}HANARO{\lrcorner}$ research reactor, the radioactive stent assembly ($^{166}Ho$-SA) was prepared by covering the metallic stent with a radioactive sleeve by means of a post-irradiation and pre-irradiation methods. Results: Scanning electron microscopy and autoradiography exhibited that the distribution of $^{165/166}Ho\;(NO_3)$ compounds in polyurethane matrix was homogeneous. A geometrical model of the esophagus considering its structural properties, was developed for the computer simulation of energy deposition to the esophageal wall. The dose distributions of $^{166}Ho$-stent were calculated by means of the EGS4 code system. The sources are considered to be distributed uniformly on the surface in the form of a cylinder with a diameter of 20 mm and length of 40 mm. As an animal experiment, when radioactive stent developed in this study was inserted into the esophagus of a Mongrel dog, tissue destruction and widening of the esophageal lumen were observed. Conclusion: We have developed a new radioactive stent comprising of a radioactive tubular sleeve covering the metallic stent, which emits homogeneous radiation. If it is inserted into the blocked or narrowed lumen, it can lead to local destruction of the tumor due to irradiation effect with dilatation resulting from self-expansion of the metallic property. Accordingly, it is expected that restenosis esophageal lumen by the continuous ingrowth and infiltration of cancer after insertion of our radioactive stent will be decreased remarkably.

  • PDF

Role of FDG-PET in the Diagnosis of Recurrence and Assessment of Therapeutic Response in Cervical Cancer and Ovarian Cancer Patients: Comparison of Diagnostic Report between PET, Abdominal a and Tumor Marker (자궁경부암 및 난소암 환자 재발진단과 치료반응평가에 있어서 FDG-PET의 역할: 양전자방출단층촬영, 복부전산화단층촬영 및 종양표지자 판독의 비교 분석)

  • Han, You-Mie;Choe, Jae-Gol;Kang, Bung-Chul
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.3
    • /
    • pp.201-208
    • /
    • 2008
  • Purpose: We aimed to assess the role of positron emission tomography using fluorodeoxyglucose (FDG-PET) in the diagnosis of recurrence or the assessment of therapeutic response in cervical and ovarian cancer patients through making a comparison between FDG-PET, abdominal computed tomography (CT) and serum tumor marker. Materials and methods: We included 103 cases (67 patients) performed FDG-PET and abdominal CT. There were 42 cervical cancers and 61 ovarian cancers. We retrospectively reviewed the interpretations of PET and CT images as well as the level of tumor marker. We calculated their sensitivity, specificity, positive predictive value and negative predictive value for these three modalities. And then we analyzed the differences between these three modalities. Results: Tumor recurrences were diagnosed in 37 cases (11 cervical cancers and 26 ovarian cancers). For PET, CT and tumor marker, in cervical cancer group, sensitivity was 100% (11/11), 54.5% (6/11) and 81.1% (9/11), respectively. And specificity was 93.6% (29/31), 93.6% (29/31) and 100% (31/31). In ovarian cancer group, sensitivity was 96.2% (25/26), 84.6% (22/26) and 80.8% (21/26), and specificity was 94.3% (33/35), 94.3% (33/35), 94.3% (33/35), PET was highly sensitive to detect the intraperitoneal and extraperitoneal metastasis with the help of the CT images to localize the lesions. However, CT had limitations in differentiation of the recurrent tumor from benign fibrotic tissue, identification of viable tumors at the interface of tissues, and detecting extraperitoneal lesions. Conclusion: FDG-PET can be an essential modality to detect the recurrent or residual tumors in gynecologic cancer patients because of its great field of the application and high sensitivity.

Analysis of Children with Unilateral Multicystic Dysplastic Kidney(MCDK) (편측성 다낭포성 신이형성증 (Unilateral multicystic dysplastic kidney)의 임상 경과)

  • Yoo Ji Hyung;Yook Jinwon;Kim Ji Hong;Kim Pyung-Kil;Han Sang Won;Kim Myung Joon
    • Childhood Kidney Diseases
    • /
    • v.4 no.1
    • /
    • pp.63-68
    • /
    • 2000
  • Purpose: MCDK is regarded as a common cause of abdominal masses in children. And the presentation of the MCDK is usually a unilateral flank mass in the a newborn. Bialteral disease results in either fetal demise or necessity fer renal replacement therapy at birth. This study is designed to assess the clinical features and natural history of the unilateral multicystic dysplastic kidney. Patients and Methods: From January 1987 to January 2000 data were obtained retrospectively on 57 patients (28 boys and 29 girls, age ranged 1day-11years) who had a diagnosis of multicystic dysplastic kidney. The diagnosis of multicystic dysplastic kidney was confirmed by a combination of ultrasonography and radionuclide scan. Voiding cystourethrogram study in 31 patients were done to determine the condition of the contalateral kidney. Restllts: $84\%$ of the patients were diagnosed before birth by antenatal ultrasonography Clinical manifestations of children with postnatal diagnoses were palpable abdominal mass($3.5\%$), abdominal distension($17\%$), and incidental($10.5\%$). The abnormalities in contralateral kidney were hydronephrosis($21\%$), compensatory hypertrophy($12\%$), simple cyst($2\%$), bifid pelvis($2\%$). Surgical management was performed in 20 patients($35\%$) due to recurrent infection, for diagnostic purpose to differentiate from malignancy and abdominal distention. Follow-up in the remaining 37 patients continued (mean 18 months) and results of sonogram findings were involution change in 23 patients($40\%$) and no interval changes in 13 patient($23\%$). Conclusions : The apparent tendency to regression of the dysplastic kidney and no difference in the number of complications justify a conservative management rather than operative intervention except in associated severe complications such as urinary tract infection or rupture of cysts.

  • PDF

Clinical Analysis of Ectopic Kidney in Children (소아 이소성 신장의 임상적 고찰)

  • Yook Jin-Won;Kim Ji-Hong;Kim Myung-Joon;Kim Pyung-Kil
    • Childhood Kidney Diseases
    • /
    • v.3 no.2
    • /
    • pp.196-202
    • /
    • 1999
  • Purpose : When the mature kidney fails to reach its norml location in the renal fossa, the condition is known as ectopic kidney. Presenting symtoms can be various and it generally depend on the associated anomaly. Beside urologic anomalies such as hydronephrosis and vesicoureteral reflux, various anomalous vascular net work, skeletal anomaly or genital anomaly can be observed in this condition. Methods : Sixteen children with ectopic kidney was studied retrospectively to analyse initial presentation, accompanied anomaly and prognosis. Results : 56% of the children were accompanied with other urologic anomalies such as true incontinence and vesicoureteral reflux that required surgical treatment. 31% of children were either diagnosed incidentally during evaluation of other non-urologic disease or during follow-up evaluation of abnormal antenatal renal sonogram. Conclusion : Ectopic kidney can be often misdiagnosed as tumorous condition or as a surgical condition depend on the abnormal location of the kidney. Careful evaluation using abdominal sonogram, DMSA, VCUG and abdominal CT scan should be performed in order to search for associated anomalous condition and for proper management.

  • PDF

Prevalence and Risk Factors of the Gallbladder Polyps Diagnosed by Ultrasound (복부초음파검사로 진단된 담낭용종의 유병률과 위험인자 분석)

  • LEE, Mi-Hwa;Cho, Pyong-Kon;Kwon, Duck-Moon
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.127-134
    • /
    • 2015
  • This study was designed to determine the prevalence of gallstones in the last three years and evaluate the associated risk factors in the population who underwent health screening. Although there are many studies reporting the prevalence and risk factors of GB polyp, the results varied among each report. The aims of this study were to evaluate the prevalence rate and risk factors of GB polyp, colon polyp and fatty liver in the population who underwent health screening. The study population consisted of 4,877 visited the health promotion center in Dalseogu, Daegu in Korea from January 2011 to December 2013. Each participant in the study had their biliary system gallbladder examined using ultrasonography. The prevalence of GB polyp was evaluated along with age, gender, metabolic syndrom, body mass index (BMI), Fatty liver, Colon polyp. A showed of total 383 (7.9%) people were found to have GB polyps. The prevalence of sex among 256 (9.8%) patients men and 127 (5.6%) women which showed significantly higher in male than in female subjects(p=0.001). The mean size of the GB polyps 4.92 mm (1.6-17 mm). The sizes of most GB polyps (73.6%) were less than 10 mm in diameter. 122 subjects (31.28%) had multiple GB polyps which 2 or more polyps and 261 subjects (68.2%) had single polyp. Independent risk factors related with GB polyp were male gender (OR 0.551, p<0.001), overweight that BMI above $23kg/m^2$ (OR 0.713, p=0.002) triglyceride (OR 0.571, P<0.001), metabolic syndrome (OR 0.049, p=0.033) and colon polyp (OR 1.409, p=0.002). In spite of the conclusion, the prevalence GB polyp was higher than previous Korea and other country reports. The GB polyp in a healthy population was results as 7.9%. The risk factors of GB polyps were found to be male, being overweight, triglyceride, metabolic syndrome and colon polyp. Not only the subject of a health examination is needed but, a further study of the general public when possible.

Evaluation to Obtain the Image According to the Spatial Domain Filtering of Various Convolution Kernels in the Multi-Detector Row Computed Tomography (MDCT에서의 Convolution Kernel 종류에 따른 공간 영역 필터링의 영상 평가)

  • Lee, Hoo-Min;Yoo, Beong-Gyu;Kweon, Dae-Cheol
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.71-81
    • /
    • 2008
  • Our objective was to evaluate the image of spatial domain filtering as an alternative to additional image reconstruction using different kernels in MDCT. Derived from thin collimated source images were generated using water phantom and abdomen B10(very smooth), B20(smooth), B30(medium smooth), B40 (medium), B50(medium sharp), B60(sharp), B70(very sharp) and B80(ultra sharp) kernels. MTF and spatial resolution measured with various convolution kernels. Quantitative CT attenuation coefficient and noise measurements provided comparable HU(Hounsfield) units in this respect. CT attenuation coefficient(mean HU) values in the water were values in the water were $1.1{\sim}1.8\;HU$, air($-998{\sim}-1000\;HU$) and noise in the water($5.4{\sim}44.8\;HU$), air($3.6{\sim}31.4\;HU$). In the abdominal fat a CT attenuation coefficient($-2.2{\sim}0.8\;HU$) and noise($10.1{\sim}82.4\;HU$) was measured. In the abdominal was CT attenuation coefficient($53.3{\sim}54.3\;HU$) and noise($10.4{\sim}70.7\;HU$) in the muscle and in the liver parenchyma of CT attenuation coefficient($60.4{\sim}62.2\;HU$) and noise ($7.6{\sim}63.8\;HU$) in the liver parenchyma. Image reconstructed with a convolution kernel led to an increase in noise, whereas the results for CT attenuation coefficient were comparable. Image scanned with a high convolution kernel(B80) led to an increase in noise, whereas the results for CT attenuation coefficient were comparable. Image medications of image sharpness and noise eliminate the need for reconstruction using different kernels in the future. Adjusting CT various kernels, which should be adjusted to take into account the kernels of the CT undergoing the examination, may control CT images increase the diagnostic accuracy.

  • PDF

Evaluation of Effective and Organ Dose Using PCXMC Program in DUKE Phantom and Added Filter for Computed Radiography System (CR 환경에서의 흉부촬영 시 Duke Phantom과 부가여과를 이용한 유효선량 및 장기선량 평가)

  • Kang, Byung-Sam;Park, Min-Joo;Kim, Seung-Chul
    • Journal of radiological science and technology
    • /
    • v.37 no.1
    • /
    • pp.7-14
    • /
    • 2014
  • By using a Chest Phantom(DUKE Phantom) focusing on dose reduction of diagnostic radiation field with the most use of artificial radiation, and attempt to reduce radiation dose studies technical radiation. Publisher of the main user of the X-ray Radiological technologists, Examine the effect of reducing the radiation dose to apply additional filtering of the X-ray generator. In order to understand the organ dose and effective dose by using the PC-Based Monte Carlo Program(PCXMC) Program, the patient receives, was carried out this research. In this experiment, by applying a complex filter using a copper and Al(aluminum,13) and filtered single of using only aluminum with the condition set, and measures the number of the disk of copper indicated by DUKE Phantom. The combination of the composite filtration and filtration of a single number of the disk of the copper is the same, with the PCXMC 2.0. Program looking combination of additional filtration fewest absorbed dose was calculated effective dose and organ dose. Although depends on the use mAs, The 80 kVp AP projection conditions, it is possible to reduce the effective amount of about 84 % from about 30 % to a maximum at least. The 120 kVp PA projection conditions, it is possible to reduce the effective amount of about 71 % from about 41 % to a maximum of at least. The organ dose, dose reduction rate was different in each organ, but it showed a decrease of dose rate of 30 % to up 100 % at least. Additional filtration was used on the imaging conditions throughout the study. There was no change in terms of video quality at low doses. It was found that using the DUKE Phantom and PCXMC 2.0 Program were suitable to calculate the effect of reducing the effective dose and organ dose.