• Title/Summary/Keyword: diagnostic radiology

Search Result 2,233, Processing Time 0.027 seconds

Utility of Computed Tomography in a Differential Diagnosis for the Patients with an Initial Diagnosis of Chronic Obstructive Pulmonary Disease Exacerbation

  • Park, Hyung Jun;Kim, Soo Han;Kim, Ho-Cheol;Lee, Bo Young;Lee, Sei Won;Lee, Jae Seung;Lee, Sang-Do;Seo, Joon Beom;Oh, Yeon-Mok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.82 no.3
    • /
    • pp.234-241
    • /
    • 2019
  • Background: The utility of computed tomography (CT) in the differential diagnosis of patients with chronic obstructive pulmonary disease (COPD) exacerbation remains uncertain. However, due to the low cost associated with CT scan along with the impact of Koreas' health insurance system, there has been a rise in the number of CT scans in the patients with initial diagnosis of COPD exacerbations. Therefore, the utility of CT in the differential diagnosis was investigated to determine whether performing CT scans affect the clinical outcomes of the patients with an initial diagnosis of COPD exacerbation. Methods: This study involved 202 COPD patients hospitalized with an initial diagnosis of COPD exacerbation. We evaluated the change in diagnosis or treatment after performing a CT scan, and compared the clinical outcomes of patient groups with vs. without performing CT (non-CT group vs. CT group). Results: After performing CT, the diagnosis was changed for two (3.0%) while additional diagnoses were made for 27 of the 64 patients (42.1%). However, the treatment changed for only one (1.5%), and six patients (9.3%) received supplementary medication. There were no difference in the median length of hospital stay (8 [6-13] days vs. 8 [6-12] days, p=0.786) and intensive care unit care (14 [10.1%] vs. 11 [16.7%], p=0.236) between the CT and non-CT groups, respectively. These findings remained consistent even after the propensity score matching. Conclusion: Utility of CT in patients with acute COPD exacerbation might not be helpful; therefore, we do not recommend chest CT scan as a routine initial diagnostic tool.

Comparison of Sizes of Anatomical Structures according to Scan Position Changes in Patients with Interstitial Lung Disease Using High-Resolution Thoracic CT (고해상도 흉부 전산화단층촬영을 이용한 간질성 폐질환을 가진 환자의 자세에 따른 해부학적 구조물 크기 비교)

  • Lee, Jae-min;Park, Je-heon;Kim, Ju-seong;Lim, Cheong-Hwan;Lee, Ki-Baek
    • Journal of radiological science and technology
    • /
    • v.44 no.2
    • /
    • pp.91-100
    • /
    • 2021
  • High-Resolution thoracic CT (HRCT) is a scanning protocol in which thin slice thickness and sharpness algorithm are utilized to enhance image resolution for diagnosis and assessment of interstitial lung disease (ILD). This examination is sometimes performed in both supine and prone position to improve sensitivity to early changes of these conditions. Anatomical structures (the size of lung field and heart and descending aorta) of 150 patients who underwent HRCT were retrospectively compared. HRCT had been conducted in two positions (supine and prone). Data were divided into five groups according to patient body weights (from 40 to more than 80kg, 10kg intervals, 60 patients/each group). Quantitative analysis was utilized in Image J program. In the supine position defined as the control group, the average values of lung fields and heart size and aorta were compared with the prone position defined as the experimental group. The size of the lungs was found to be higher in the supine position, and it was confirmed that there was a statistically significant difference in patients over 70 kg (p<0.05). In addition, both sizes of the heart and descending aorta were larger in prone position, but in the case of the heart, there was no correlation with the presence or absence of ILD disease (p>0.05). Also, the area of prone in the descending aorta was higher than supine position, but there was no statistically significant difference between supine and prone position (p>0.05). In conclusion, when the severity of ILD disease was severe, there was no statistically significant difference in the area difference between supine and prone position, so it is considered that it will be helpful in diagnostic decision.

Association Between Low Muscle Mass and Non-alcoholic Fatty Liver Disease Diagnosed Using Ultrasonography, Magnetic Resonance Imaging Derived Proton Density Fat Fraction, and Comprehensive NAFLD Score in Korea

  • Lee, Hun Ju;Chang, Jae Seung;Ahn, Jhii Hyun;Kim, Moon Young;Park, Kyu-Sang;Ahn, Yeon-Soon;Koh, Sang Baek
    • Journal of Preventive Medicine and Public Health
    • /
    • v.54 no.6
    • /
    • pp.412-421
    • /
    • 2021
  • Objectives: Non-alcoholic fatty liver disease (NAFLD) is an increasingly prevalent metabolic disease. Muscle is known to influence NAFLD development. Therefore, this study aimed to determine the relationships among low muscle mass, NAFLD, and hepatic fibrosis using various definitions of low muscle mass and NAFLD diagnostic methods, including magnetic resonance imaging-based proton density fat fraction (MRI-PDFF). Methods: This cross-sectional study included 320 participants (107 males, 213 females) from the Korean Genome and Epidemiology Study on Atherosclerosis Risk of Rural Areas in the Korean General Population cohort. Muscle mass was assessed using whole-body dual-energy X-ray absorptiometry and adjusted for the height squared, body weight, and body mass index (BMI). NAFLD was diagnosed using ultrasonography (US), MRI-PDFF, and the comprehensive NAFLD score (CNS). Hepatic fibrosis was assessed using magnetic resonance elastography. Multivariable logistic and linear regression analyses were performed to determine the aforementioned associations. Results: According to US, 183 participants (57.2%) had NAFLD. Muscle mass adjusted for body weight was associated with NAFLD diagnosed using US (odds ratio [OR], 3.00; 95% confidence interval [CI], 1.70 to 5.31), MRI-PDFF (OR, 2.00; 95% CI, 1.13 to 3.53), and CNS (OR, 3.39; 95% CI, 1.73 to 6.65) and hepatic fibrosis (males: β=-0.070, p<0.01; females: β=-0.037, p<0.04). Muscle mass adjusted for BMI was associated with NAFLD diagnosed by US (OR, 1.71; 95% CI, 1.02 to 2.86) and CNS (OR, 1.95; 95% CI, 1.04 to 3.65), whereas muscle mass adjusted for height was not associated with NAFLD. Conclusions: Low muscle mass was associated with NAFLD and liver fibrosis; therefore, maintaining sufficient muscle mass is important to prevent NAFLD. A prospective study and additional consideration of muscle quality are needed to strengthen the findings regarding this association.

Fe3O4 magnetic nanoparticles provide a novel alternative strategy for Staphylococcus aureus bone infection

  • Youliang, Ren;Jin, Yang;Jinghui, Zhang;Xiao, Yang;Lei, Shi;Dajing, Guo;Yuanyi, Zheng;Haitao, Ran;Zhongliang, Deng;Lei, Chu
    • Advances in nano research
    • /
    • v.13 no.6
    • /
    • pp.575-585
    • /
    • 2022
  • Due to its biofilm formation and colonization of the osteocyte-lacuno canalicular network (OLCN), Staphylococcus aureus (S.aureus) implant-associated bone infection (SIABI) is difficult to cure thoroughly, and may occur recurrently subsequently after a long period dormant. It is essential to explore an alternative therapeutic strategy that can eradicate the pathogens in the infected foci. To address this, the polymethylmethacrylate (PMMA) bone cement and Fe3O4 nanoparticles compound cylinder were developed as implants based on their size and mechanical properties for the alternative magnetic field (AMF) induced thermal ablation, The PMMA mixed with optimized 2% Fe3O4 nanoparticles showed an excellent antibacterial efficacy in vitro. It was evaluated by the CFU, CT scan and histopathological staining on a rabbit 1-stage transtibial screw model. The results showed that on week 7, the CFU of infected soft tissue and implants, and the white blood cells (WBCs) of the PMMA+2% Fe3O4+AMF group decreased significantly from their controls (p<0.05). PMMA+2% Fe3O4+AMF group did not observe bone resorption, periosteal reaction, and infectious reactive bone formation by CT images. Further histopathological H&E and Gram Staining confirmed there was no obvious inflammatory cell infiltration, neither pathogens residue nor noticeably burn damage around the infected screw channel in the PMMA+2% Fe3O4+AMF group. Further investigation of nanoparticle distributions in bone marrow medullary and vital organs of heart, liver, spleen, lung, and kidney. There were no significantly extra Fe3O4 nanoparticles were observed in the medullary cavity and all vital organs either. In the current study, PMMA+2% Fe3O4+AMF shows promising therapeutic potential for SIABI by providing excellent mechanical support, and promising efficacy of eradicating the residual pathogenic bacteria in bone infected lesions.

Efficiency and accuracy of artificial intelligence in the radiographic detection of periodontal bone loss: A systematic review

  • Asmhan Tariq;Fatmah Bin Nakhi;Fatema Salah;Gabass Eltayeb;Ghada Jassem Abdulla;Noor Najim;Salma Ahmed Khedr;Sara Elkerdasy;Natheer Al-Rawi;Sausan Alkawas;Marwan Mohammed;Shishir Ram Shetty
    • Imaging Science in Dentistry
    • /
    • v.53 no.3
    • /
    • pp.193-198
    • /
    • 2023
  • Purpose: Artificial intelligence (AI) is poised to play a major role in medical diagnostics. Periodontal disease is one of the most common oral diseases. The early diagnosis of periodontal disease is essential for effective treatment and a favorable prognosis. This study aimed to assess the effectiveness of AI in diagnosing periodontal bone loss through radiographic analysis. Materials and Methods: A literature search involving 5 databases (PubMed, ScienceDirect, Scopus, Health and Medical Collection, Dentistry and Oral Sciences) was carried out. A specific combination of keywords was used to obtain the articles. The PRISMA guidelines were used to filter eligible articles. The study design, sample size, type of AI software, and the results of each eligible study were analyzed. The CASP diagnostic study checklist was used to evaluate the evidence strength score. Results: Seven articles were eligible for review according to the PRISMA guidelines. Out of the 7 eligible studies, 4 had strong CASP evidence strength scores (7-8/9). The remaining studies had intermediate CASP evidence strength scores (3.5-6.5/9). The highest area under the curve among the reported studies was 94%, the highest F1 score was 91%, and the highest specificity and sensitivity were 98.1% and 94%, respectively. Conclusion: AI-based detection of periodontal bone loss using radiographs is an efficient method. However, more clinical studies need to be conducted before this method is introduced into routine dental practice.

Visualization and Localization of Fusion Image Using VRML for Three-dimensional Modeling of Epileptic Seizure Focus (VRML을 이용한 융합 영상에서 간질환자 발작 진원지의 3차원적 가시화와 위치 측정 구현)

  • 이상호;김동현;유선국;정해조;윤미진;손혜경;강원석;이종두;김희중
    • Progress in Medical Physics
    • /
    • v.14 no.1
    • /
    • pp.34-42
    • /
    • 2003
  • In medical imaging, three-dimensional (3D) display using Virtual Reality Modeling Language (VRML) as a portable file format can give intuitive information more efficiently on the World Wide Web (WWW). The web-based 3D visualization of functional images combined with anatomical images has not studied much in systematic ways. The goal of this study was to achieve a simultaneous observation of 3D anatomic and functional models with planar images on the WWW, providing their locational information in 3D space with a measuring implement using VRML. MRI and ictal-interictal SPECT images were obtained from one epileptic patient. Subtraction ictal SPECT co-registered to MRI (SISCOM) was performed to improve identification of a seizure focus. SISCOM image volumes were held by thresholds above one standard deviation (1-SD) and two standard deviations (2-SD). SISCOM foci and boundaries of gray matter, white matter, and cerebrospinal fluid (CSF) in the MRI volume were segmented and rendered to VRML polygonal surfaces by marching cube algorithm. Line profiles of x and y-axis that represent real lengths on an image were acquired and their maximum lengths were the same as 211.67 mm. The real size vs. the rendered VRML surface size was approximately the ratio of 1 to 605.9. A VRML measuring tool was made and merged with previous VRML surfaces. User interface tools were embedded with Java Script routines to display MRI planar images as cross sections of 3D surface models and to set transparencies of 3D surface models. When transparencies of 3D surface models were properly controlled, a fused display of the brain geometry with 3D distributions of focal activated regions provided intuitively spatial correlations among three 3D surface models. The epileptic seizure focus was in the right temporal lobe of the brain. The real position of the seizure focus could be verified by the VRML measuring tool and the anatomy corresponding to the seizure focus could be confirmed by MRI planar images crossing 3D surface models. The VRML application developed in this study may have several advantages. Firstly, 3D fused display and control of anatomic and functional image were achieved on the m. Secondly, the vector analysis of a 3D surface model was defined by the VRML measuring tool based on the real size. Finally, the anatomy corresponding to the seizure focus was intuitively detected by correlations with MRI images. Our web based visualization of 3-D fusion image and its localization will be a help to online research and education in diagnostic radiology, therapeutic radiology, and surgery applications.

  • PDF

Comparison of Horizontal and Vertical Noise Power Spectrum in Measurements by Using Various Electronic Portal Imaging Devices in Radiation Therapy (방사선치료 시 전자포털 영상장치를 이용한 잡음전력스펙트럼 수평 및 수직 측정비교)

  • Kim, Ki-Won;Choi, Kwan-Woo;Jeong, Hoi-Woun;Jang, Seo-Goo;Kwon, Kyung-Tae;Son, Soon-Yong;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.171-176
    • /
    • 2016
  • The quality assurance (QA) is very important for diagnostic field and radiation therapy field to evaluate the characteristic of devices. The purpose of this study was to compare different NPS methodologies results which are measuring NPS with regard to horizontal and vertical directions by using megavoltage X-ray energies. The NPS evaluation methods were applied to the International Electro-technical Commission standard (IEC 62220-1). The electronic portal imaging devices (EPID) devices such as Siemens BEAMVIEW$^{PLUS}$, Elekta iViewGT and Varian Clinac$^R$ iX aS1000 were used. NPS data were expressed by corresponding each frequency about average of noise value corresponding the each frequency, and NPS were evaluated quantitatively by totaling up the noise values of average frequency which are on horizontal and vertical directions. In NPS results for Elekta iViewGT, NPS of horizontal and vertical by using 4 methods were indicated the difference of 3~5% between horizontal and vertical direction. In the results of Siemens BEAMVIEW$^{PLUS}$ and Varian Clinac$^R$ iX aS1000, the NPS of horizontal and vertical direction were indicated the difference of 15% when averaging the whole values. This study were evaluated the NPS of each devices by totaling up the noise values of average frequency which are on horizontal and vertical directions suggesting the quantitative evaluation method using the data.

Usefulness of Bronchoscopy for the Diagnosis of Nontuberculous Mycobacterial Pulmonary Disease (비결핵 항산균 폐질환의 진단에서 기관지내시경술의 유용성)

  • Jeon, Kyeongman;Koh, Won-Jung;Kwon, O Jung;Kang, Eun Hae;Suh, Gee Young;Chung, Man Pyo;Kim, Hojoong;Kim, Tae Sung;Lee, Kyung Soo;Lee, Nam Yong;Han, Joungho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.57 no.3
    • /
    • pp.242-249
    • /
    • 2004
  • Background : Because of the low sensitivity of sputum smear and culture, diagnosis of nontuberculous mycobacterium (NTM) pulmonary disease, especially in patients with bronchiectasis, is often difficult. We investigated the usefulness of bronchoscopy for the diagnosis of NTM pulmonary disease including M. avium complex (MAC) and M. abscessus in patients with bronchiectasis and multiple pulmonary nodules on chest computed tomography (CT). Methods : We reviewed 48 cases of patients who were performed bronchoscopic bronchoalveolar lavage (BAL) and transbronchial lung biopsy (TBLB) under suspect of NTM pulmonary disease based on CT findings of bronchiectasis and multiple nodules from April 2002 to June 2003. Results : Twenty five of the 48 patients (54%; 12 MAC, 14 M. abscessus) were diagnosed as NTM pulmonary disease on the basis of the American Thoracic Society diagnostic criteria for NTM pulmonary disease. Sixteen of the 21 patients (76%; 5 MAC, 11 M. abscessus) with 3 or more positive sputum cultures of NTM were confirmed tissue invasion by TBLB. Five of the 24 patients (21%; 4 MAC, 1 M. abscessus) who could not be diagnosed with sputum cultures were diagnosed by bronchoscopic BAL and TBLB. Conclusion : Bronchoscopy is helpful for the diagnosis of NTM pulmonary disease and confirmation of tissue invasion by NTM, not only MAC but also M. abscessus, in patients with bronchiectasis and multiple nodules on chest CT scan.

The Role and Significance of Biomarker for Plasma G-CSF in Patients with Primary Lung Cancer (원발성 폐암에서 혈장 과립구 자극인자의 암표지자로서의 역할과 의의)

  • Song, Jung Sub;Kim, So Young;Jo, Hyang Jeong;Lee, Kang Kyoo;Shin, Jeong Hyun;Shin, Seong Nam;Kim, Dong;Park, Seong Hoon;Lee, Young Jin;Ko, Chang Bo;Lee, Mi Kung;Choi, Soon Ho;Jeong, Jong Hoon;Park, Jung Hyun;Kim, Hui Jung;Kim, Hak Ryul;Jeong, Eun Taik;Yang, Sei Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.66 no.6
    • /
    • pp.444-450
    • /
    • 2009
  • Background: Biomarkers for cancer have several potential clinical uses, including the following: early cancer detection, monitoring for recurrence prognostication, and risk stratification. However, no biomarker has been shown to have adequate sensitivity and specificity. Many investigators have tried to validate biomarkers for the early detection and recurrence of lung cancer. To evaluate plasma G-CSF as such a biomarker, protein levels were measured and were found to correlate with the clinicopathological features of primary lung tumors. Methods: Between December 2006 and May 2008, 100 patients with histologically-validated primary lung cancer were enrolled into this study. To serve as controls, 127 healthy volunteers were enrolled into this study. Plasma G-CSF levels were measured in lung cancer patients using the sandwich ELISA system (R & D inc.) prior to treatment. Results: The mean plasma G-CSF levels were 12.2$\pm$0.3 pg/mL and 46.0$\pm$3.8 pg/mL (mean$\pm$SE) in the normal and in the cancer groups, respectively. In addition, plasma G-CSF levels were higher in patients with early lung cancer than in healthy volunteers (p<.001). Plasma G-CSF levels were higher in patients who were under 65 years old or smokers. Within the cancer group, plasma G-CSF levels were higher in patients with non small cell lung cancer than in patients with small cell lung cancer (p<.05). Overall, plasma G-CSF levels were shown to increase dependent upon the type of lung cancer diagnsosed. In the order from highest to lowest, the levels of plasma G-CSF tended to decrease in the following order: large cell carcinoma, squamous cell carcinoma, adenocarcinoma, and bronchioloalveolar carcinoma. Plasma G-CSF levels tended to be higher in patients with advanced TNM stage than in localized TNM stage (I, II

Survery on Business of the Departments of Radiology in Health Centers (보건소(保健所)의 방사선과(放射線科) 업무(業務)에 관한 조사연구(調査硏究))

  • Choi, Jong-Hak;Jeon, Man-Jin;Huh, Joon;Park, Sung-Ock
    • Journal of radiological science and technology
    • /
    • v.8 no.2
    • /
    • pp.21-28
    • /
    • 1985
  • We serveyed the actual condition of business of the departments of radiology of 45 health conters (except 3) in the area of Seoul, Kyungki and Inchon from March, 1984 to November, 1984. The results are summarized as follows : 1. T.O. of the radiologic technologist is three persons in each health center of Seoul area, and one person in each one of Kyungki and Inchon area. P.O. is 2-5 persons in Seoul area, 1-2 persons in Kyungki or Inchon area. 2. The number of all the radiologic technologists employed now is 75 persons, and among all of them, when analized by position class 7th is 54.7%, class 8th 28.0%, class 9th is 13.3%, and class 6th is 2.7%, and by sex, female is 68.0%, male is 32.0%, by educational background, for the most part, junior college graduates come to 73.3%, by age group 60% of them is in their twenties, 16.0% is in their thirties and forties, 8.0% is in their fifties, and by career after certificate 60% have the career of 1-5 years, 13.3% have the one of 6-7 years or mor than 21 years, and 6.7% have the one of 11-15 years of 16-20 years. 3. All the diagnostic x-ray equipment being kept is 62, and among them flxing equipment is 71.0%, portable equipment is 29.0% and by rating of X-ray equipment, maximum tube current 100 mA is 46.8%, maximum KV 100KVP is 72.6%, the most part. 4. Photofluorographic camera and hood are equipped in every health center. While, as to the radiographic cassettes, $14{\times}14"$ cassetts are equipped in every health center, but cassettes of other sizes are in half of them. 5. Bucky's table is equipped in 11.9% health centers, the automatic processor is in 21.4%, the photofluorographic film changer is 9.5%, the grid is 73.8%, the protective apron is in 88.1%, and the protective glove is in 57.1% health centers. 6. The number of the people who got the x-ray examination for one year (by the year 1989) is the most, 1,000-6,000 in direct radiography of the chest, or 15,0001-45,000 in the health centers of Seoul area, 5,000-20,000 in Kyungki and Inchon area in photofluorography of the chest. Moreover, other radiographies are being taken extremely limitedly in all health centers. 7. In processing types of x-ray film, automatic processing is used in 9 health centers (21.4%), manual tank processing is in 30 (71.4%), and manual tray processing in 3 (7.2%). 8. As for collimation of x-ray exposure field, "continual using restricted by a subject size" has the most part, 78.6% "restricted using at every radiography" has 19%, and the case of "never considered" has 2.4% response. 9. As for the dosimeter used for radiation control, film badge (35.7%) and pocket dosimeter (26.2%) are used, and in 38.1% health centers the dosimeter is not equipped at all. Consideration of the previous radiation exposure is being done in only one health center. 10. Reading of radiographs is mainly depended on the radiologists electively (45.2%) or on the genral practitioners(45.2%).

  • PDF