• Title/Summary/Keyword: diagnostic radiology

Search Result 2,235, Processing Time 0.028 seconds

The Application of Wedge Type Compensation Filter for Uniform Density on the Endoscopic Retrograde Pancreatography (내시경적 역행성 췌관 조영상의 균등한 농도를 위한 적절한 쐐기형 필터의 적용)

  • Son, Soon-Yong;Lee, Hee-Jeong;Lee, Won-Hong;Cho, Cheong-Chan;Ryu, Meung-Sun;Jung, Hong-Ryang
    • Journal of radiological science and technology
    • /
    • v.24 no.1
    • /
    • pp.5-9
    • /
    • 2001
  • Over-density of pancreatic duct tail part on the endoscopic retrograde pancreatogram results from patient's position and inserted air during the study. The aim of this paper is to decide the filter angle to obtain an uniform density. Endoscopic retrograde pancreatography was performed to 234 patients, and angled wedge filter was used differently. They are $10^{\circ}$ (47), $20^{\circ}$ (45), $30^{\circ}$ (50), and $40^{\circ}$ (50). We also did not use wedge filter to 42 patients. We decided reliance degree in 95%. The statistical difference was p<0.05. The patients' sex rate was 1.8 : 1 between 18 and 87 years old(average age 58 years). Their body girth was 18.71 cm on the average. Of total 234 patients, difference of right and left average density was 0.01 by $30^{\circ}$ wedge filter, -0.08 $40^{\circ}$ wedge filter and 0.27 non-wedge filter. These average values of difference density were very significant statistically, and standard deviation also was close to regular distribution. In conclusion, there is a usefulness of angled wedge filter for increasing diagnostic value of pancreatic duct tall part on the endoscopic retrograde pancreatogram.

  • PDF

Comparison of Core Needle Biopsy and Repeat Fine-Needle Aspiration in Avoiding Diagnostic Surgery for Thyroid Nodules Initially Diagnosed as Atypia/Follicular Lesion of Undetermined Significance

  • Leehi Joo;Dong Gyu Na;Ji-hoon Kim;Hyobin Seo
    • Korean Journal of Radiology
    • /
    • v.23 no.2
    • /
    • pp.280-288
    • /
    • 2022
  • Objective: To compare core needle biopsy (CNB) and repeat fine-needle aspiration (rFNA) to reduce the rate of diagnostic surgery and prevent unnecessary surgery in nodules initially diagnosed as atypia/follicular lesions of undetermined significance (AUS/FLUS). Materials and Methods: This study included 231 consecutive patients (150 female and 81 male; mean age ± standard deviation, 51.9 ± 11.7 years) with 235 thyroid nodules (≥ 1 cm) initially diagnosed as AUS/FLUS, who later underwent both rFNA and CNB. The nodules that required diagnostic surgery after the biopsy were defined using three different scenarios according to the rFNA and CNB results: criterion 1, surgery for low-risk indeterminate (categories I and III); criterion 2, surgery for high-risk indeterminate (categories IV and V); and criterion 3, surgery for all indeterminate nodules (categories I, III, IV, and V). We compared the expected rates of diagnostic surgery between CNB and rFNA in all 235 nodules using the three surgical criteria. In addition, the expected rates of unnecessary surgery (i.e., surgery for benign pathology) were compared in a subgroup of 182 nodules with available final diagnoses. Results: CNB showed significantly lower rates of nondiagnostic, AUS/FLUS, and suspicious for malignancy diagnoses (p ≤ 0.016) and higher rates of follicular neoplasm or suspicious for a follicular neoplasm (p < 0.001) and malignant diagnoses (p = 0.031). CNB showed a significantly lower expected rate of diagnostic surgery than rFNA for criterion 1 (29.8% vs. 48.1%, p < 0.001) and criterion 3 (46.4% vs. 55.3%, p = 0.029), and a significantly higher rate for criterion 2 (16.6% vs. 7.2%, p = 0.001). CNB showed a significantly lower expected rate of unnecessary surgery than rFNA for criterion 1 (18.7% vs. 29.7%, p = 0.024). Conclusion: CNB was superior to rFNA in reducing the rates of potential diagnostic surgery and unnecessary surgery for nodules initially diagnosed as AUS/FLUS in a scenario where nodules with low-risk indeterminate results (categories I and III) would undergo surgery.

Role of Contrast-Enhanced Ultrasound as a Second-Line Diagnostic Modality in Noninvasive Diagnostic Algorithms for Hepatocellular Carcinoma

  • Hyo-Jin Kang;Jeong Min Lee;Jeong Hee Yoon;Joon Koo Han
    • Korean Journal of Radiology
    • /
    • v.22 no.3
    • /
    • pp.354-365
    • /
    • 2021
  • Objective: To investigate the diagnostic performance of contrast-enhanced ultrasound (CEUS) and its role as a second-line imaging modality after gadoxetate-enhanced MRI (Gd-EOB-MRI) in the diagnosis of hepatocellular carcinoma (HCC) among at risk observations. Materials and Methods: We prospectively enrolled participants at risk of HCC with treatment-naïve solid hepatic observations (≥ 1 cm) of Liver Imaging Reporting and Data System (LR)-3/4/5/M during surveillance and performed Gd-EOB-MRI. A total of one hundred and three participants with 103 hepatic observations (mean size, 28.2 ± 24.5 mm; HCCs [n = 79], non-HCC malignancies [n = 15], benign [n = 9]; diagnosed by pathology [n = 57], or noninvasive method [n = 46]) were included in this study. The participants underwent CEUS with sulfur hexafluoride. Arterial phase hyperenhancement (APHE) and washout on Gd-EOB-MRI and CEUS were evaluated. The distinctive washout in CEUS was defined as mild washout 60 seconds after contrast injection. The diagnostic ability of Gd-EOB-MRI and of CEUS as a second-line modality for HCC were determined according to the European Association for the Study of the Liver (EASL) and the Korean Liver Cancer Association and National Cancer Center (KLCA-NCC) guidelines. The diagnostic abilities of both imaging modalities were compared using the McNemar's test. Results: The sensitivity of CEUS (60.8%) was lower than that of Gd-EOB-MRI (72.2%, p = 0.06 by EASL; 86.1%, p < 0.01 by KLCA-NCC); however, the specificity was 100%. By performing CEUS on the inconclusive observations in Gd-EOB-MRI, HCCs without APHE (n = 10) or washout (n = 12) on Gd-EOB-MRI further presented APHE (80.0%, 8/10) or distinctive washout (66.7%, 8/12) on CEUS, and more HCCs were diagnosed than with Gd-EOB-MRI alone (sensitivity: 72.2% vs. 83.5% by EASL, p < 0.01; 86.1% vs. 91.1% by KCLA-NCC, p = 0.04). There were no false-positive cases for HCC on CEUS. Conclusion: The addition of CEUS to Gd-EOB-MRI as a second-line diagnostic modality increases the frequency of HCC diagnosis without changing the specificities.

Automated Breast Ultrasound System for Breast Cancer Evaluation: Diagnostic Performance of the Two-View Scan Technique in Women with Small Breasts

  • Bo Ra Kwon;Jung Min Chang;Soo Yeon Kim;Su Hyun Lee;Soo-Yeon Kim;So Min Lee;Nariya Cho;Woo Kyung Moon
    • Korean Journal of Radiology
    • /
    • v.21 no.1
    • /
    • pp.25-32
    • /
    • 2020
  • Objective: To comparatively evaluate the scan coverage and diagnostic performance of the two-view scan technique (2-VST) of the automated breast ultrasound system (ABUS) versus the conventional three-view scan technique (3-VST) in women with small breasts. Materials and Methods: Between March 2016 and May 2017, 136 asymptomatic women with small breasts (bra cup size A) suitable for 2-VST were enrolled. Subsequently, 272 breasts were subjected to bilateral whole-breast ultrasound examinations using ABUS and the hand-held ultrasound system (HHUS). During ABUS image acquisition, one breast was scanned with 2-VST, while the other breast was scanned with 3-VST. In each breast, the breast coverage and visibility of the HHUS detected lesions on ABUS were assessed. The sensitivity and specificity of ABUS were compared between 2-VST and 3-VST. Results: Among 136 breasts, eight cases of breast cancer were detected by 2-VST, and 10 cases of breast cancer were detected by 3-VST. The breast coverage was satisfactory in 94.1% and 91.9% of cases under 2-VST and 3-VST, respectively (p = 0.318). All HHUS-detected lesions were visible on the ABUS images regardless of the scan technique. The sensitivities and specificities were similar between 2-VST and 3-VST (100% [8/8] vs. 100% [10/10], and 97.7% [125/128] vs. 95.2% [120/126], respectively), with no significant difference (p > 0.05). Conclusion: 2-VST of ABUS achieved comparable scan coverage and diagnostic performance to that of conventional 3-VST in women with small breasts.

CT and MRI for Repaired Complex Adult Congenital Heart Diseases

  • Suvipaporn Siripornpitak;Hyun Woo Goo
    • Korean Journal of Radiology
    • /
    • v.22 no.3
    • /
    • pp.308-323
    • /
    • 2021
  • An increasing number of adult congenital heart disease (ACHD) patients continue to require life-long diagnostic imaging surveillance using cardiac CT and MRI. These patients typically exhibit a large spectrum of unique anatomical and functional changes resulting from either single- or multi-stage palliation and surgical correction. Radiologists involved in the diagnostic task of monitoring treatment effects and detecting potential complications should be familiar with common cardiac CT and MRI findings observed in patients with repaired complex ACHD. This review article highlights the contemporary role of CT and MRI in three commonly encountered repaired ACHD: repaired tetralogy of Fallot, transposition of the great arteries after arterial switch operation, and functional single ventricle after Fontan operation.

A Study on the Radiation Safety and the Vocational Consciousness of the Diagnostic Radiotechnologists (3) 진단방사선사의 방사선안전관리 및 직업의식에 관한 조사)

  • Lee Kang Woo;Kim Kyung Bae;Kim Jae Kwon
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.25 no.1
    • /
    • pp.177-191
    • /
    • 1999
  • We conducted a survey into the radiation safety and their vocational consciousness in May in 1998. The population consisted of 273 diagnostic radiotechnologists who have worked in medical institutions in Chonbuk province. The results was as follows; 1. In

  • PDF

Development and Validation of Generalized Linear Regression Models to Predict Vessel Enhancement on Coronary CT Angiography

  • Masuda, Takanori;Nakaura, Takeshi;Funama, Yoshinori;Sato, Tomoyasu;Higaki, Toru;Kiguchi, Masao;Matsumoto, Yoriaki;Yamashita, Yukari;Imada, Naoyuki;Awai, Kazuo
    • Korean Journal of Radiology
    • /
    • v.19 no.6
    • /
    • pp.1021-1030
    • /
    • 2018
  • Objective: We evaluated the effect of various patient characteristics and time-density curve (TDC)-factors on the test bolus-affected vessel enhancement on coronary computed tomography angiography (CCTA). We also assessed the value of generalized linear regression models (GLMs) for predicting enhancement on CCTA. Materials and Methods: We performed univariate and multivariate regression analysis to evaluate the effect of patient characteristics and to compare contrast enhancement per gram of iodine on test bolus (${\Delta}HUTEST$) and CCTA (${\Delta}HUCCTA$). We developed GLMs to predict ${\Delta}HUCCTA$. GLMs including independent variables were validated with 6-fold cross-validation using the correlation coefficient and Bland-Altman analysis. Results: In multivariate analysis, only total body weight (TBW) and ${\Delta}HUTEST$ maintained their independent predictive value (p < 0.001). In validation analysis, the highest correlation coefficient between ${\Delta}HUCCTA$ and the prediction values was seen in the GLM (r = 0.75), followed by TDC (r = 0.69) and TBW (r = 0.62). The lowest Bland-Altman limit of agreement was observed with GLM-3 (mean difference, $-0.0{\pm}5.1$ Hounsfield units/grams of iodine [HU/gI]; 95% confidence interval [CI], -10.1, 10.1), followed by ${\Delta}HUCCTA$ ($-0.0{\pm}5.9HU/gI$; 95% CI, -11.9, 11.9) and TBW ($1.1{\pm}6.2HU/gI$; 95% CI, -11.2, 13.4). Conclusion: We demonstrated that the patient's TBW and ${\Delta}HUTEST$ significantly affected contrast enhancement on CCTA images and that the combined use of clinical information and test bolus results is useful for predicting aortic enhancement.

Percutaneous Sacroplasty for Painful Sacral Metastases Involving Multiple Sacral Vertebral Bodies: Initial Experience with an Interpedicular Approach

  • Qing-Hua Tian;He-Fei Liu;Tao Wang;Ying-Sheng Cheng;Chun-Gen Wu
    • Korean Journal of Radiology
    • /
    • v.20 no.6
    • /
    • pp.939-946
    • /
    • 2019
  • Objective: To report our initial experience of percutaneous sacroplasty (PSP) with an interpedicular approach for treating painful sacral metastases involving multiple sacral vertebral bodies. Materials and Methods: This study prospectively enrolled 10 consecutive patients (six men and four women; mean age, 56.3 ± 13.8 years) who underwent PSP for painful sacral metastases involving multiple sacral vertebral bodies from March 2017 to September 2018. Visual analogue scale (VAS) scores, Oswestry disability index (ODI) values, and the number of opioids prescribed to the patients were assessed before and after PSP. The procedure duration, length of hospitalization, and complications were also recorded. Results: Mean VAS and ODI declined significantly from 6.90 ± 1.20 and 74.40 ± 5.48 before the procedure to 2.70 ± 1.34 and 29.60 ± 14.57 after the procedure, respectively (p < 0.01). The median number of opioids prescribed per patient decreased from 2 (interquartile range [IQR] 1-3) pre-procedure to 1 (IQR 0-3) post-procedure (p < 0.01). Nine of the 10 patients showed no or decreased opioid usage, and only 1 patient showed unchanged usage. The mean procedure duration was 48.5 ± 3.0 minutes. The average length of hospitalization was 4.7 ± 1.7 days. Extraosseous cement leakage occurred in three cases without causing any clinical complications. Conclusion: PSP with an interpedicular approach is a safe and effective treatment in patients with painful sacral metastases involving multiple sacral vertebral bodies and can relieve pain and improve mobility.

Evaluation of the Biodurability of Polyurethane-Covered Stent Using a Flow Phantom

  • Dong Hyun Kim;Sung-Gwon Kang;Jung Ryul Choi;Ju Nam Byun;Young Chul Kim;Young Moo Ahn
    • Korean Journal of Radiology
    • /
    • v.2 no.2
    • /
    • pp.75-79
    • /
    • 2001
  • Objective: To evaluate the biodurability of the covering material in retrievable metallic stents covered with polycarbonate polyurethane. Materials and Methods: Using a peristaltic pump at a constant rate of 1ml/min, bile was recirculated from a reservoir through a long tube containing four stents. Each of these was removed from the system every two weeks and a radial tensile strength test and scanning electron microscopy (SEM) were performed. Each stent, removed at 2, 4, 6 and 8 weeks, was compared with a control stent not exposed to bile juice. Results: Gross examination showed that stents were intact at 2 weeks, but at 4, 6 and 8 weeks cracks were observed. The size of these increased gradually in accordance with the duration of exposure, and at 8 weeks several large holes in the polyurethane membrane were evident. With regard to radial tensile strength, extension and peak load at break were 84.47% and 10.030 N/mm, 54.90% and 6.769 N/mm, 16.55% and 2.452 N/mm, 11.21% and 1.373 N/mm at 0, 2, 4 and 6 weeks, respectively. Scanning electron microscopy at 2 weeks revealed intermittent pitting and cracking, and examination at 4, 6 and 8 weeks showed that the size of these defects was gradually increasing. Conclusion: When the polyurethane membrane was exposed to bile, biodegradation was first observed at week two and increased gradually according to the duration of exposure.

  • PDF

Comparative Performance of Susceptibility Map-Weighted MRI According to the Acquisition Planes in the Diagnosis of Neurodegenerative Parkinsonism

  • Suiji Lee;Chong Hyun Suh;Sungyang Jo;Sun Ju Chung;Hwon Heo;Woo Hyun Shim;Jongho Lee;Ho Sung Kim;Sang Joon Kim;Eung Yeop Kim
    • Korean Journal of Radiology
    • /
    • v.25 no.3
    • /
    • pp.267-276
    • /
    • 2024
  • Objective: To evaluate the diagnostic performance of susceptibility map-weighted imaging (SMwI) taken in different acquisition planes for discriminating patients with neurodegenerative parkinsonism from those without. Materials and Methods: This retrospective, observational, single-institution study enrolled consecutive patients who visited movement disorder clinics and underwent brain MRI and 18F-FP-CIT PET between September 2021 and December 2021. SMwI images were acquired in both the oblique (perpendicular to the midbrain) and the anterior commissure-posterior commissure (AC-PC) planes. Hyperintensity in the substantia nigra was determined by two neuroradiologists. 18F-FP-CIT PET was used as the reference standard. Inter-rater agreement was assessed using Cohen;s kappa coefficient. The diagnostic performance of SMwI in the two planes was analyzed separately for the right and left substantia nigra. Multivariable logistic regression analysis with generalized estimating equations was applied to compare the diagnostic performance of the two planes. Results: In total, 194 patients were included, of whom 105 and 103 had positive results on 18F-FP-CIT PET in the left and right substantia nigra, respectively. Good inter-rater agreement in the oblique (κ = 0.772/0.658 for left/right) and AC-PC planes (0.730/0.741 for left/right) was confirmed. The pooled sensitivities for two readers were 86.4% (178/206, left) and 83.3% (175/210, right) in the oblique plane and 87.4% (180/206, left) and 87.6% (184/210, right) in the AC-PC plane. The pooled specificities for two readers were 83.5% (152/182, left) and 82.0% (146/178, right) in the oblique plane, and 83.5% (152/182, left) and 86.0% (153/178, right) in the AC-PC plane. There were no significant differences in the diagnostic performance between the two planes (P > 0.05). Conclusion: There are no significant difference in the diagnostic performance of SMwI performed in the oblique and AC-PC plane in discriminating patients with parkinsonism from those without. This finding affirms that each institution may choose the imaging plane for SMwI according to their clinical settings.