• Title/Summary/Keyword: diagnostic key

Search Result 387, Processing Time 0.02 seconds

Research Progress of CXCR4-Targeting Radioligands for Oncologic Imaging

  • Yanzhi Wang;Feng Gao
    • Korean Journal of Radiology
    • /
    • v.24 no.9
    • /
    • pp.871-889
    • /
    • 2023
  • C-X-C motif chemokine receptor 4 (CXCR4) plays a key role in various physiological functions, such as immune processes and disease development, and can influence angiogenesis, proliferation, and distant metastasis in tumors. Recently, several radioligands, including peptides, small molecules, and nanoclusters, have been developed to target CXCR4 for diagnostic purposes, thereby providing new diagnostic strategies based on CXCR4. Herein, we focus on the recent research progress of CXCR4-targeting radioligands for tumor diagnosis. We discuss their application in the diagnosis of hematological tumors, such as lymphomas, multiple myelomas, chronic lymphocytic leukemias, and myeloproliferative tumors, as well as nonhematological tumors, including tumors of the esophagus, breast, and central nervous system. Additionally, we explored the theranostic applications of CXCR4-targeting radioligands in tumors. Targeting CXCR4 using nuclear medicine shows promise as a method for tumor diagnosis, and further research is warranted to enhance its clinical applicability.

Comparison of Pre-Operation Diagnosis of Thyroid Cancer with Fine Needle Aspiration and Core-needle Biopsy: a Meta-analysis

  • Li, Lei;Chen, Bao-Ding;Zhu, Hai-Feng;Wu, Shu;Wei, Da;Zhang, Jian-Quan;Yu, Li
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.17
    • /
    • pp.7187-7193
    • /
    • 2014
  • Background: The aim of this meta-analysis was to compare sensitivities and specificities of fine needle aspiration (FNA) and core needle biopsy (CNB) in the diagnosis of thyroid cancer. Materials and Methods: Articles were screened in Medline, the Cochrane Library, EMBASE and Google Scholar, and subsequently included and excluded based on the patient/problem-intervention-comparison-outcome (PICO) principle. Primary outcome was defined in terms of diagnostic values (sensitivity and specificity) of FNA and CNB for thyroid cancer. Secondary outcome was defined as the accuracy of diagnosis. Compiled FNA and CNB results from the final studies selected as appropriate for meta-analysis were compared with cases for which final pathology diagnoses were available. Statistical analyses were performed for FNA and CNB for all of the selected studies together, and for individual studies using the leave-one-out approach. Results: Article selection and screening yielded five studies for meta-analysis, two of which were prospective and the other three retrospective, for a total of 1,264 patients. Pooled diagnostic sensitivities of FNA and CNB methods were 0.68 and 0.83, respectively, with specificities of 0.93 and 0.94. The areas under the summary ROC curves were 0.905 (${\pm}0.030$) for FNA and 0.745 (${\pm}0.095$) for CNB, with no significant difference between the two. No one study had greater influence than any other on the pooled estimates for diagnostic sensitivity and specificity. Conclusions: FNA and CNB do not differ significantly in sensitivity and specificity for diagnosis of thyroid cancer.

Diagnostic Value of Fluorescence in Situ Hybridization Assay in Malignant Mesothelioma: A Meta-analysis

  • Wan, Chun;Shen, Yong-Chun;Liu, Meng-Qi;Yang, Ting;Wang, Tao;Chen, Lei;Yi, Qun;Wen, Fu-Qiang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.9
    • /
    • pp.4745-4749
    • /
    • 2012
  • The diagnosis of malignant mesothelioma (MM) remains a clinical challenge and the fluorescence in situ hybridization (FISH) assay has been reported to be one promising tool. The present meta-analysis aimed to establish the overall diagnostic accuracy of FISH for diagnosing MM. After a systematic review of English language studies, the sensitivity, specificity and other measures of accuracy of FISH in the diagnosis of MM were pooled using random-effects models. Summary receiver operating characteristic curves were applied to summarize overall test performance. Nine studies met our inclusion criteria, the pooled sensitivity and specificity for FISH for diagnosing MM being 0.72 (95% CI 0.67-0.76) and 1.00 (95% CI 0.98-1.00), respectively. The positive likelihood ratio was 34.5 (95% CI 14.5-82.10), the negative likelihood ratio was 0.24 (95% CI 0.16-0.36), and the diagnostic odds ratio was 204.9 (95% CI 76.8-546.6), the area under the curve being 0.99. Our data suggest that the FISH assay is likely to be a useful diagnostic tool for confirming MM. However, considering the limited studies and patients included, further large scale studies are needed to confirm these findings.

Diagnostic Significance of Combined Detection of Epstein-Barr Virus Antibodies, VCA/IgA, EA/IgA, Rta/IgG and EBNA1/IgA for Nasopharyngeal Carcinoma

  • Cai, Yong-Lin;Li, Jun;Lu, Ai-Ying;Zheng, Yu-Ming;Zhong, Wei-Ming;Wang, Wei;Gao, Jian-Quan;Zeng, Hong;Cheng, Ji-Ru;Tang, Min-Zhong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.5
    • /
    • pp.2001-2006
    • /
    • 2014
  • The objective of this study was to investigate the diagnostic significance of EBV antibody combined detection for nasopharyngeal carcinoma (NPC) in a high incidence region of southern China. Two hundred and eleven untreated NPC patients, 203 non-NPC ENT patients, and 210 healthy controls were recruited for the study. The titers of VCA/IgA and EA/IgA were assessed by immunoenzyme assay, and the levels of Rta/IgG and EBNA1/IgA were determined by enzyme-linked immunosorbent assay. The levels of VCA/IgA, EA/IgA, Rta/IgG and EBNA1/IgA demonstrated no association with gender or age (p>0.05). The receiver operating characteristic curve and the area under the curve were used to evaluate the diagnostic value. The sensitivity of VCA/IgA (98.1%) and the specificity of EA/IgA (98.5%) were the highest. When a logistic regression model was used to combine the results from multiple antibodies to increase the accuracy, the combination of VCA/IgA+Rta/IgG, whose area under the curve was 0.99, had the highest diagnostic efficiency, and its sensitivity, specificity and Youden index were 94.8%, 98.0% and 0.93 respectively. The data suggest that the combination of VCA/IgA+Rta/IgG may be most suitable for NPC serodiagnosis.

Detection of Acute Toxoplasmosis in Pigs Using Loop-Mediated Isothermal Amplification and Quantitative PCR

  • Wang, Yanhua;Wang, Guangxiang;Zhang, Delin;Yin, Hong;Wang, Meng
    • Parasites, Hosts and Diseases
    • /
    • v.51 no.5
    • /
    • pp.573-577
    • /
    • 2013
  • A loop-mediated isothermal amplification (LAMP) assay allows rapid diagnosis of Toxoplasma gondii infection. In the present study, the LAMP assay was evaluated using blood from both naturally and experimentally infected pigs. The sensitivity of the LAMP assay was compared with that of Q-PCR. Both assays detected T. gondii in the blood of experimentally infected pigs, with 100% agreement. In infected blood samples, the parasite was detected as early as 2 days post-infection and reached a peak in 3-5 days. In 216 field serum samples, the detection rates of LAMP and Q-PCR assays were 6.9% and 7.8%, respectively. This result indicates that the sensitivity of the LAMP assay was slightly lower than that of the Q-PCR assay. However, the LAMP may be an attractive diagnostic method in conditions where sophisticated and expensive equipment is unavailable. This assay could be a powerful supplement to current diagnostic methods.

A rapid and quantitative fluorescent microsphere immunochromatographic strip test for detection of antibodies to porcine reproductive and respiratory syndrome virus

  • Wei, Yanqiu;Yang, Baozhi;Li, Yunlong;Duan, Yongcheng;Tian, Deyu;He, Baoxiang;Chen, Chuangfu;Liu, Wenjun;Yang, Limin
    • Journal of Veterinary Science
    • /
    • v.21 no.4
    • /
    • pp.68.1-68.8
    • /
    • 2020
  • A fluorescent microsphere-based immunochromatographic strip test (FICT) was developed for the rapid, sensitive, and quantitative detection of porcine reproductive and respiratory syndrome virus (PRRSV) antibodies at the pen-side. The assay was based on the formation of a sandwich immune-complex (anti-pig IgG-PRRSV antibodies-NSP7/N), which was validated by a comparison with IDEXX-ELISA using 3325 clinical specimens. The diagnostic specificity, sensitivity, and accuracy of FICT were 97.28, 93.41, and 94.95%, respectively. FICT showed a good correlation with the virus neutralization assay. Overall, a promising pen-side diagnostic tool was developed for the rapid and quantitative detection of PRRSV antibodies within 15 min.

MRI in the Diagnosis of Endometriosis and Related Diseases

  • Aki Kido;Yuki Himoto;Yusaku Moribata;Yasuhisa Kurata;Yuji Nakamoto
    • Korean Journal of Radiology
    • /
    • v.23 no.4
    • /
    • pp.426-445
    • /
    • 2022
  • Endometriosis, a common chronic inflammatory disease in female of reproductive age, is closely related to patient symptoms and fertility. Because of its high contrast resolution and objectivity, MRI can contribute to the early and accurate diagnosis of ovarian endometriotic cysts and deeply infiltrating endometriosis without the need for any invasive procedure or radiation exposure. The ovaries, which are the most frequent site of endometriosis, can be afflicted by multiple related conditions and diseases. For the diagnosis of deeply infiltrating endometriosis and secondary adhesions among pelvic organs, fibrosis around the ectopic endometrial gland is usually found as a T2 hypointense lesion. This review summarizes the MRI findings obtained for ovarian endometriotic cysts and their physiologically and pathologically related conditions. This article also includes the key imaging findings of deeply infiltrating endometriosis.

Fused Polypeptide with DEF Induces Apoptosis of Lung Adenocarcinoma Cells

  • Liang, Ai-Ling;Zhang, Ting-Ting;Zhou, Ning;Huang, Di-Nan;Liu, Xin-Guang;Liu, Yong-Jun;Tu, Zhi-Guang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.12
    • /
    • pp.7339-7344
    • /
    • 2013
  • To analyze the effects of a new unknown peptide DEF on the growth of tumor cells, a fused polypeptide TAT-DV1-DEF was designed and synthesized. The lung adenocarcinoma cell line GLC-82 treated with TAT-DV1-DEF was analyzed with a cell counting kit 8, and the location of polypeptides in cells was observed under laser confocal microscopy. The efficiency of polypeptide transfection and changes in nuclear morphology were analyzed by flow cytometry and fluorescence microscopy, respectively. Finally, the mechanism of tumor cell growth inhibition was evaluated by Western blotting. We found that TAT-DV1-DEF could significantly inhibit the growth of the lung adenocarcinoma cell line GLC-82, but not the normal human embryonic kidney cell line HEK-293. Polypeptides were found to be mostly localized in the cytoplasm and some mitochondria. The efficiency of polypeptide transfection in the two cell types was approximately 99%. Apoptotic nuclei were observed under fluorescence microscopy upon treatment with polypeptides and DAPI staining. Western blot analyses indicated that the polypeptide inhibition of tumor cell growth was apoptosis dependent. In the present study, we demonstrated that fused polypeptides could induce apoptosis of the lung adenocarcinoma cell line GLC-82, indicating that the new unknown peptide DEF has antitumor effects.

Evaluation of functional suitable digital complete denture system based on 3D printing technology

  • Deng, Kehui;Chen, Hu;Wang, Yong;Zhou, Yongsheng;Sun, Yuchun
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.6
    • /
    • pp.361-372
    • /
    • 2021
  • PURPOSE. To improve the clinical effects of complete denture use and simplify its clinical application, a digital complete denture restoration workflow (Functional Suitable Digital Complete Denture System, FSD) was proposed and preliminary clinical evaluation was done. MATERIALS AND METHODS. Forty edentulous patients were enrolled, of which half were treated by a prosthodontic chief physician, and the others were treated by a postgraduate student. Based on the primary impression and jaw relation obtained at the first visit, diagnostic denture was designed and printed to create a definitive impression, jaw relation, and esthetic confirmation at the second visit. A redesigned complete denture was printed as a mold to fabricate final denture that was delivered at the third visit. To evaluate accuracy of impression made by diagnostic denture, the final denture was used as a tray to make impression, and 3D comparison was used to analyze their difference. To evaluate the clinical effect of FSD, visual analogue scores (VAS) were determined by both dentists and patients. RESULTS. Two visits were reduced before denture delivery. The RMS values of 3D comparison between the impression made via diagnostic dentures and the final dentures were 0.165 ± 0.033 mm in the upper jaw and 0.139 ± 0.031 mm in the lower jaw. VAS ratings were between 8.5 and 9.6 in the chief physician group, while 7.7 and 9.5 in the student group; there was no statistical difference between the two groups. CONCLUSION. FSD can simplify the complete denture restoration process and reduce the number of visits. The accuracy of impressions made by diagnostic dentures was acceptable in clinic. The VASs of both dentists and patients were satisfied.

An Open Circuit Fault Diagnostic Technique in IGBTs for AC to DC Converters Applied in Microgrid Applications

  • Khomfoi, Surin;Sae-Kok, Warachart;Ngamroo, Issarachai
    • Journal of Power Electronics
    • /
    • v.11 no.6
    • /
    • pp.801-810
    • /
    • 2011
  • An open circuit fault diagnostic method in IGBTs for the ac to dc converters used in microgrid applications is developed in this paper. An ac to dc converter is a key technology for microgrids in order to interface both distributed generation (DG) and renewable energy resources (RES). Also, highly reliable ac to dc converters are necessary to keep converters in continuous operation as long as possible during power switch fault conditions. Therefore, the proposed fault diagnostic method is developed to reduce the fault detection time and to avoid any other fault alarms because continuous operation is desired. The proposed diagnostic method is a combination of the absolute normalized dc current technique and the false alarm suppression algorithm to overcome the long fault detection time and fault alarm problems. The simulation and experimental results show that the developed fault diagnostic method can perform fault detection within about one cycle. The results illustrate that the reliability of an ac to dc converter interfaced with a microgrid can be improved by using the proposed fault diagnostic method.