방사선치료계획 정도관리 방법에 따른 신뢰도 평가 (Reliability estimation about quality assurance method of radiotherapy planning)

  • 김정호;김가중;유세종;김기진
    • 대한안전경영과학회지
    • /
    • 제17권1호
    • /
    • pp.119-124
    • /
    • 2015
  • According as radiation therapy technique develops, standardization of radiation therapy has been complicated by the plan QA(Quality Assurance). However, plan QA tools are two type, OADT (opposite accumulation dose tool) and 3DADT (3 dimensional accumulation dose tool). OADT is not applied to evaluation of beam path. Therefore tolerance error of beam path will establish measurement value at OADT. Plan is six beam path, five irradiation field at each beam path. And beam path error is 0 degree, 0.2 degree, 0.4 degree, 0.6 degree, 0.6 degree, 0.8 degree. Plan QA accomplishes at OADT, 3DADT. The more path error increases, the more plan QA error increases. Tolerance error of OADT path is 0.357 using tolerance error of conventional plan QA. Henceforth plan QA using OADT will include beam path error. In addition, It will increase reliability through precise and various plan technique.

판독용 모니터 정도관리 항목 및 시행기준안 개발 연구 (A Study on Quality Assurance(QA) Guideline for Diagnostic Monitor)

  • 손기경;성동욱;정해조;정재호;강희두;신진호;이순근;김용환
    • 대한디지털의료영상학회논문지
    • /
    • 제9권1호
    • /
    • pp.53-65
    • /
    • 2007
  • PACS has been run at the Kyung Hee University Medical Center(KHMC) since 2001, and the installation and operation of PACS have contributed to automation and quantification of KHMC's medical environment During these five years our greatest concern is how to make our own guiding principle of diagnostic monitor QA which is adapted to international standards. In accordance with the terms of 'KHMC QA Guideline', 'AAPM TG18', 'SMPTE RP133', 'DICOM Part14', 'DIN V 6868-57', 'JESRA X-0093', 'JIS Z4752-2-5' and 'KCARE', concern about quality assurance of medical images are on the increase. With the investigation of acceptance testing and quality control of international standards for medical display devices, and data collection and analysis for recommended guideline, it is reported that acceptance testing(quality control), including geometrical distortion, display reflection, luminance response, luminance uniformity, display resolution, display noise, veiling glare and color chromaticity being adequate and effective to domestic hospital environments for medical display devices and assessment methods according to each performance. Accordingly, KHMC classified the checkpoint items by period, at the time of monitor setting, monthly, quarterly, half-yearly and annually. Periodic classification of checkpoint items for monitor QA makes a good guideline for image QA/QC and useful guideline for persistent good quality of monitor.

  • PDF

동물병원의 방사선발생장치 정도관리에 대한 연구 (Quality Control of Diagnostic X-ray Units for Animal Hospital)

  • 김상우;이지훈;박예슬;임재동;성열훈
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2010년도 춘계학술대회
    • /
    • pp.231-237
    • /
    • 2010
  • The purpose of this study was to investigate the actual conditions of radiation safety supervision in animal clinics using quality assurance (QA) and quality control (QC) of diagnostic X-ray units. The surveys for QA/QC, equipment condition, and safety supervision were carried out in 18 animal clinics randomly. The QA/QC included reproducibility of dose exposure, kVp, mAs, collimator accuracy test, collimator luminance test, X-ray view box luminance test, grounding system equipment test and external leakage current test. As a result, 44.44% of reproducibility of dose exposure was proper, 81. 25% of kVp test was good, and 100% of mAs test was appropriate. Also, 66.66% of collimator accuracy test was proper, 61.11% of collimator luminance test was good, 53.13% of X-ray view box luminance test was suitable. In addition, only 5.55% of grounding system equipment and ground resistance was proper, 63.64% of external leakage current test was appropriate in grounding system equipment test.

  • PDF

결핵 적정성 평가에 따른 국내 결핵 진료서비스 질 관리 현황 (Change in Quality of Tuberculosis (TB) Care since National Quality Assessment Program of TB Healthcare Service)

  • 장성자;황미진;이충훈;이현주;심태선;김동숙
    • 한국의료질향상학회지
    • /
    • 제27권2호
    • /
    • pp.73-82
    • /
    • 2021
  • Purpose: This study aims to examine the quality of tuberculosis (TB) care after the 1st to 3rd national quality assessment (QA) program for TB healthcare service in Korea was conducted. Methods: We analyzed Health Insurance Review & Assessment Service (HIRA) claims data of new TB patients during the period of January to June from 2018-2020. The new TB patients were defined as TB patients reported to Korea Centers for Disease Control and Prevention Agency (KCDA). The unit of analysis was the patient. Chi-square tests were used to analyze the differences in indicator value according to the types of medical facilities. The QA indicators of TB care were divided into 3 areas consisting of the following 7 quality indicators: 4 indicators of diagnosis test (the rate of acid-fast bacilli smear, the rate of acid-fast bacilli culture, the rate of Mycobacterium tuberculosis-polymerase chain reaction, drug susceptibility test), 1 compliance of treatment guideline, and 2 indicators of care management of TB patients (encounter rate, day of therapy). Results: The QA program for TB care was conducted among 8,246 patients from 534 facilities in 2020. The value of the 7 quality indicators was shown to increase as a result of the QA program. The indicators of the diagnostic test were all higher than 95%, with the exception of the drug susceptibility test which was 84.8%. Both indicators for care management of TB patients were 88.5%. Conclusion: The quality of TB care has been improving with the implementation of the QA program. In order to continue to improve the quality of TB care, it will be necessary to disclose the results of the QA program in medical facilities in the future.

임상가를 위한 특집 4 - CBCT 검사법의 정도관리 및 선량 (Radiation Doses and Quality Assurance in Cone Beam CT(CBCT))

  • 최용석;김규태;황의환
    • 대한치과의사협회지
    • /
    • 제52권3호
    • /
    • pp.153-163
    • /
    • 2014
  • 3-dimensional information for anatomic stucture plays a role as integral part in clinical aspect of dental practice. CBCT(cone beam computed tomography) has been accepted as useful diagnostic tool offering Volume data and images for evaluating teeth and jaws in lower radiation dose than conventional CT. CBCT equipment is essential for the quality assurance of it to ensure continued satisfactory performance and result of adequate images. Dental practitioner and oral and maxillofacial radiologist should have a responsibility and critical thinking to deliver this technology to patients in a responsible way, so that diaganostic value is maximised and radiation doses kept as low as resonably achievable. CBCT imaging modality should be used only after a review of the patient's health and imaging history and the completion of a thorough clinical examination. Clinical guidelines are systematically developed statements to assist practitioner and patient decisions about appropriate health care for specific clinical circumstances Dental practitioners should prescribe CBCT imaging only when they expect that the diagnostic yield will benefit patient care, enhance patient safety or improve clinical outcomes significantly. Knowledge of patient dose is essential for clinicians who are making the decision regarding the justification of the exposure. There are some limitation in the measurement of patient dose in CBCT for the approval and adaptation of conventinal methodolgy in CT. It is also important to ensure that doses are optimised and in line with any national and international guidelines. The higher radiation doses of CBCT compared with conventional radiography, mean that high standards must be maintained. The Quality Assurance(QA) programme should entail surveys and checks that are performed according to a regular timetable. QA programme should be maintained by staff to ensure adherence to the programme and to raise its importance among staff.

혈관협착팬텀의 제작 및 파워도플러의 영상 평가 (Manufacture of Flow Phantom with Stenosis and Imaging Evaluation of Power Doppler)

  • 박희영;배종림;김정구
    • 한국음향학회지
    • /
    • 제28권8호
    • /
    • pp.732-739
    • /
    • 2009
  • 혈관협착의 혈류 정보와 초음파 진단장비의 품질보증을 위한 혈관협착 팬텀을 자동 주입기를 이용하여 제작하였다. 혈관협착의 진단에 효율성이 높은 파워 도플러를 이용하여 제작된 혈관 협착 팬텀의 유용성을 조사하고, 초음파 영상 파라메타에 따른 혈관협착의 정도를 확인하였다. 혈관 협착 팬텀은 직경이 각각 8mm와 2.4mm인 실리콘 튜브로 혈관협착이 70%가 되도록 제작하였으며, 인체 조직과 유사한 음향 특성을 가지고 있는 젤라틴을 이용하여 실리콘 튜브를 감싸 주었다. 평면형 탐촉자를 이용하여 측정하였을 때 정상 혈관의 직경은 대체적으로 감소되어 측정 되었으며, 협착 혈관의 직경은 증가되어 측정되었다. 이득이 60% 이상, PRF가 3000Hz 이상, 필터가 max와 같은 급격한 변화를 제외하고는 각각의 파라메타에 크게 영향을 받지 않았으며, 각도에는 영향을 받지 않는 것으로 나타났다. 또한 곡면형 탐촉자를 이용할 경우 이득, PRF, 필터, 각도등에 영향을 받는 것으로 나타났다. 본 연구에서 제작된 자동주입기를 이용한 혈관 협착 팬텀은 혈관 협착 진단의 품질보증에 유용하게 이용될 수 있을 것으로 기대된다.

전자장비 고장진단 질의응답을 위한 인과관계 정의 및 추출 (Definition and Extraction of Causal Relations for Question-Answering on Fault-Diagnosis of Electronic Devices)

  • 이신목;신지애
    • 한국정보과학회논문지:소프트웨어및응용
    • /
    • 제35권5호
    • /
    • pp.335-346
    • /
    • 2008
  • 온톨로지의 인과관계는 특정 응용을 위한 추론에서 중요한 역할을 하므로, 인과관계는 응용에서 쓰이는 추론의 형태에 근거하여 정의되어야 한다. 본 논문에서는, 전자장비의 고장진단 질의응답을 위한 온톨로지에서의 인과관계를 정의하고 추출하는 모델을 제시한다. 질의응답의 패턴을 분석하여 인과범주를 정의하고, 질의응답에서 나타나는 개념들 사이의 관계들 중 인과범주에 속하는 경우를 인과관계로 정의한다. 인과관계 인스턴스는 응용분야의 정의문으로부터 어휘 패턴을 이용하여 추출되고 시소러스 정보를 이용하여 점진적으로 확장된다. 분야 전문가들의 평가 결과, 본 모델은 관계분류에 있어서 92.3%의 평균 정확률과 추출 단계의 인과관계 인식에 있어서 80.7%의 정확률을 보인다.

조직등가팬텀을 이용한 임상초음파 영상의 질에 관한 연구 - 제주도 내 병원을 중심으로 - (A Study on the Quality of Image of Ultrasound Using the Tissue-mimicking Phantom - in some hospitals jeju province)

  • 양정화;이경성
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제29권2호
    • /
    • pp.63-69
    • /
    • 2006
  • 초음파 영상의 질은 진단에 많은 영향을 끼친다. 양질의 영상이 항상 일정하게 유지되기 위해서는 QA(Quality Assurance) 프로그램을 가지고 주기적인 관리가 이루어져야 할 것이다. 본 논문은 임상에서의 QA 상황을 파악하는 첫 번째 단계로 실제 병원의 초음파 영상의 질을 살펴보고자 하였다. 이를 위해 인간의 생체등가물질로 된 팬텀을 이용하여 정상 환자를 스캔할 때와 같은 기준 값에서 가상의 낭포 및 고반사 신호의 구조물들이 몇 개가 보이는지 convex probe와 linear probe를 측정하여 비교하였다. convex probe에서는 정상 간과 비슷한 0.5 dB에서 vertical group, cystic masses, high contrast masses에서는 대부분 잘 보였으며 지방간과 비슷한 조건인 0.7 dB에서는 vertical group이 중간레벨에서, cystic masses와 high contrast masses에서는 대체로 모두 잘 보였다. linear probe에서의 vertical group은 0.5 dB에서 중간레벨만 잘 보였고 cystic masses와 high contrast masses는 두 개에서 네 개 보이는 것들이 고루 분포되었으나 하나도 보이는 않는 경우가 11건수나 되었다. 0.7 dB에서는 vertical group이 6개 이하가 보이는 것이 대부분 이었고 cystic masses와 high contrast masses에서도 두개에서 네 개 보이는 것들이 고루 분포되었고 하나도 보이는 않는 경우도 40건 있었다. 이로서 지방간과 같은 조건하에서는 linear probe의 영상의 질이 대체로 좋지 않으므로 기준 설정 및 물리적인 조건들을 검사 시에 잘 조정하거나 probe의 교체가 필요하다고 판단된다. 많은 병원에서 초음파 장비를 잘 관리하고 있다고 하지만, 영상의 질은 아직도 미흡한 것을 알 수 있다. 초음파 장비의 설치에서부터 영상의 질을 평가하고 지속적이고 정기적인 관리와 평가가 이루어질 수 있는 프로그램이 필요하겠다.

  • PDF

영상의학 검사 판독용 모니터 정도관리 Guiding Instrument 제작과 유용성 고찰 (A Study on Production and Its Usefulness of AAPM TG18 Guiding Instrument for Diagnostic Monitor QC)

  • 손기경;성동욱;정재호;강희두;류경남
    • 대한디지털의료영상학회논문지
    • /
    • 제10권1호
    • /
    • pp.21-28
    • /
    • 2008
  • Diagnostic display monitor QA according to AAPM TG18 is usually performed by PACS administrator, product manager and reading doctor, and for acceptance testing and periodic quality control evaluation, a combination of visual and quantitative tests can be used, as outlined in sections 5 and 6 of 'assessment of display performance for medical imaging systems'. Although many display tests can be performed visually, a more objective and quantitative evaluation of display performance requires special test tools. The required instruments vary in their complexity and cost, depending on the context of the evaluation(research, acceptance testing, or quality control) and how thorough the evaluation needs to be. Objective and reliable assessment of many display characteristics can be performed with relatively inexpensive equipment, So, we made 'AAPM TG18 guiding instrument' to ues variable purpose of the evaluation of 'geometrical distortions(quantitative"', 'veiling glare(visual)' and 'sensor calibration'. The spatial measurements for the quantitative evaluation of geometric distortions, and the measurement of the veling-glare ring response function which provides information regarding the spatial extent of the luminance spread, can be performed using the TG18 guiding instrument can be used to sensor calibration to standardize the basic rate of 0% luminance when periodic calibration.

  • PDF

진단용 방사선 발생장치의 수시 정도관리 항목 및 기준에 관한 기초 연구 (A Base Study on the Constancy Quality Control Test and Clause of Diagnosis Radiation Equipment)

  • 허예지;김교태;노시철;남상희;박지군
    • 한국방사선학회논문지
    • /
    • 제8권3호
    • /
    • pp.105-110
    • /
    • 2014
  • 국내 진단용 방사선 발생장치는 3년 주기로 시행되는 정기적인 정도관리 검사에 앞서 일별, 주별, 월별, 분기 반기별로 시행하는 수시 정도 관리에 대한 항목 및 규정이 명확하게 지정되어 있지 않다. 미국과 유럽 등의 선진국에서는 정도 관리 항목에 대해 검사를 수행하는 검사자를 구분하여 국가 기관에 보고하도록 되어 있으므로 체계적인 검사 수행과 더불어 검토가 가능하다. 그러므로 의료 장비의 현대화가 이루어지는 시점에서 국외의 주기별 정도관리 시스템을 국내 진단용 방사선 발생 장치에 적합하도록 도입하여 정도관리 항목과 기준의 재정립이 반드시 필요하다. 이에 본 논문에서는 진단용 방사선 발생장치 중 가장 빈번히 사용되고 있는 일반 X선 촬영 장치의 3년 정기점검 사이에 주기적인 수시 정도 관리 검사 항목과 방법 및 기준 수립을 위해 미국, 캐나다 등의 국외 문헌 조사 및 국제 전자 기술 위원회(International Electro-technical Commission, IEC)의 규정 항목과 비교하였다. 이를 바탕으로 국내 수시 정도관리 항목 신설 시 필요한 검사 항목 및 기준 설정을 위한 기초 자료로 제시하고자 하였다.