• 제목/요약/키워드: diagnosis architecture

검색결과 214건 처리시간 0.026초

SAE J1939 프로토콜기반 Gateway 제어모듈 개발에 관한 연구 (The Study of Gateway Control Module Using SAE J1939 Protocol)

  • 고영진;김도영
    • 한국자동차공학회논문집
    • /
    • 제21권1호
    • /
    • pp.128-136
    • /
    • 2013
  • This study presents the development of Gateway Control Module using SAE J1939 protocol for the commercial vehicles. Presently, the load rate of CAN bus is increased by the single network composition and addition of new ECUs for development of intelligent vehicles. Because the embedded system of the integrated network control function has the errors of the CAN bus caused by the increase of ECU, it is needed for development of commercial vehicles. Also, this study presents the development of smart functions that can diagnosis CAN bus errors, fault diagnosis of ECU and basic function that arbitrates CAN bus between ECUs of commercial vehicle. GCM was designed for 4channel separation about Gateway function as solution of load rate decrease and smart functions. HILS(Hardware in the loop simulation)system that can achieve simulation about CAN Messages of all systems on vehicle was applied to evaluate performance and verification of all functions and performance. The load rate on CAN bus was decreased at using functions what was delivery, block and process of GCM. Through this, it was enabled to organize systematic architecture for gateway.

Operational Availability Improvement through Online Monitoring and Advice For Emergency Diesel Generator

  • Lee, Jong-Beom;Kim, han-Gon;Kim, Byong-Sub;M. Golay;C.W. Kang;Y. Sui
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1998년도 춘계학술발표회논문집(1)
    • /
    • pp.264-270
    • /
    • 1998
  • This research broadens the prime concern of nuclear power plant operations from safe performance to both economic and safe performance. First emergency diesel generator is identified as one of main contributors for the lost plant availability through the review of plants forced outage records. The framework of an integrated architecture for performing modern on-line condition for operational availability improvement is configured in this work. For the development of the comprehensive sensor networks for complex target systems, an integrated methodology incorporating a structural hierarchy, a functional hierarchy, and a fault-system matrix is formulated. The second part of our research is development of intelligent diagnosis and maintenance advisory system, which employs Bayesian Belief networks (BBNs) as a high level reasoning tool incorporating inherent uncertainty use in probabilistic inference. Our prototype diagnosis algorithms are represented explicitly through topological symbols and links between them in a causal direction. As new evidence from sensor network development is entered into the model especially, our advisory of system provides operational advice concerning both availability and safety, so that the operator is able to determine the likely modes, diagnose the system state, locate root causes, and take the most advantageous action. Thereby, this advice improves operational availability

  • PDF

EEG 분석과 분류시스템 (EEG Analysis and Classification System)

  • 정대영;김민수;서희돈
    • 융합신호처리학회논문지
    • /
    • 제5권4호
    • /
    • pp.263-270
    • /
    • 2004
  • 최근 웨이블릿 변환은 많은 분야에서 다양하게 적용된다. 본 논문에서 tasks뇌파의 중요한 몇가지 특성파 검출을 위한 다비치 웨이블릿은 뇌파분석에 필요하다. 우리가 제안한 시스템은 다른 방법보다는 특성파 검출에 높은 성능을 가졌다. 본 연구의 뉴럴시스템의 구조는 하나의 은닉층과 3계층 피드포워드층은 오류 BP 학습알고리즘을 적용하였다. 4명의 피험자에게 알고리즘을 적용하여 92% 분류율을 보였다. 제안된 시스템은 웨이블릿과 신경망으로 tasks 뇌파의 보다 정확하게 분석함을 보였다. 모의실험결과 tasks 뇌파는 의사의 노동력을 줄일수 있고 정량적 해석이 가능함을 보였다.

  • PDF

IEC61850 기반 디지털 변전시스템에서의 eCMD 융합화구조 적용에 관한 연구 (A study on the application of the IEC61850 based eCMD convergence structure in Digital Substation)

  • 이동철;김희수;배을록;민병운
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 전기설비
    • /
    • pp.19-22
    • /
    • 2006
  • The CMD(Condition Monitoring & Diagnosis) System is used to monitor and analyze the PD(Partial Discharge), Arc, Temperature, Pressure, Gas in Oil and so on for reliability and availability of the substation. Although this system comes into the spotlight as the forecast and management of the failure and fault, there are some problems. For example, the unified standard was not defined, and the effective management of the layed communication network does not performed, limitation of physical space, etc. To resolve above problems, this paper suggests the IEC61850 compatible eCMD system architecture for monitoring and analyzing the CMD factor in substations. The suggested eCMD system consists of CMD-LU(Condition Monitoring & Diagnosis-Local Unit), IED(Intelligent Electronic Device), and engineering centers. The IEC61850 is the international standard that defines communication networks and system in substation.

  • PDF

Estimation of Compressive Strength of Reinforced Concrete Structure Using Impact Testing Method and Rebound Hardness Method

  • Hong, Seonguk;Kim, Seunghun;Lee, Yongtaeg;Jeong, Jaewon;Lee, Changyong;Park, Chanwoo
    • Architectural research
    • /
    • 제20권4호
    • /
    • pp.137-145
    • /
    • 2018
  • The nondestructive test is widely used in the field of diagnosis and maintenance to evaluate the degree of damaging of structures caused by aging, and the demand for this test method is expected to continue increasing. However, there is a lack of standards related to the nondestructive test, and South Korea is relying heavily on developed nations for original technologies related to diagnosis. It is an urgent task to establish a nondestructive test method appropriate for the circumstance of South Korea. The purpose of this study is to compare and analyze estimated error of compressive strength in single-story structures comprised of vertical and horizontal reinforced concrete members using the impact testing method and rebound hardness method, which are nondestructive test methods, and to review on-site applicability of these methods. Based on compressive strength of the structures estimated, overall mean error was 21.2% for the impact testing method and 15.6% for the rebound hardness method. The necessity of a reliable diagnostic method based on compound nondestructive test methods to increase accuracy of estimation was confirmed.

Minimum thickness of flat plates considering construction load effect

  • Hwang, Hyeon-Jong;Ma, Gao;Kim, Chang-Soo
    • Structural Engineering and Mechanics
    • /
    • 제69권1호
    • /
    • pp.1-10
    • /
    • 2019
  • In the construction of flat plate slabs, which are widely used for tall buildings but have relatively low flexural stiffness, serviceability problems such as excessive deflections and cracks are of great concern. To prevent excessive deflections at service load levels, current design codes require the minimum slab thickness, but the requirement could be unconservative because it is independent on loading and elastic modulus of concrete, both of which have significant effects on slab deflections. In the present study, to investigate the effects of the construction load of shored slabs, reduced flexural stiffness and moment distribution of early-age slabs, and creep and shrinkage of concrete on immediate and time-dependent deflections, numerical analysis was performed using the previously developed numerical models. A parametric study was performed for various design and construction conditions of practical ranges, and a new minimum permissible thickness of flat plate slabs was proposed satisfying the serviceability requirement for deflection. The proposed minimum slab thickness was compared with current design code provisions and numerical analysis results, and it agreed well with the numerical analysis results.

The role of cone-beam computed tomography in the radiographic evaluation of obstructive sleep apnea: A review article

  • Marco Isaac;Dina Mohamed ElBeshlawy;Ahmed ElSobki;Dina Fahim Ahmed;Sarah Mohammed Kenawy
    • Imaging Science in Dentistry
    • /
    • 제53권4호
    • /
    • pp.283-289
    • /
    • 2023
  • The apnea-hypopnea index is widely regarded as a measure of the severity of obstructive sleep apnea (OSA), a condition characterized by recurrent episodes of apnea or hypopnea during sleep that induce airway collapse. OSA is a catastrophic problem due to the wide range of health issues it can cause, including cardiovascular disease and memory loss. This review was conducted to clarify the roles of various imaging modalities, particularly cone-beam computed tomography (CBCT), in the diagnosis of and preoperative planning for OSA. Unfortunately, 2-dimensional imaging techniques yield insufficient data for a comprehensive diagnosis, given the complex anatomy of the airway. Three-dimensional (3D) imaging is favored as it more accurately represents the patient's airway structure. Although computed tomography and magnetic resonance imaging can depict the actual 3D airway architecture, their use is limited by factors such as high radiation dose and noise associated with the scans. This review indicates that CBCT is a low-radiation imaging technique that can be used to incidentally identify patients with OSA, thereby facilitating early referral and ultimately enhancing the accuracy of surgical outcome predictions.

지상 레이저스캐너를 이용한 고건축물의 3차원 모델링 (3 Dimensional Modelling of a Old Architecture Using a Terrrestrial Laser Scanner)

  • 이진덕;도철호;한승희
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2007년도 추계 종합학술대회 논문집
    • /
    • pp.30-34
    • /
    • 2007
  • 레이저는 단시간에 높은 정밀도로 다량의 측정을 행할 수 있는 장점을 지니며, 이의 구체적인 실현이 지상 LiDAR라고도 불리는 지상레이저 스캐너이다. 본 논문에서는 Z-F 레이저시스템을 사용하여 대상물의 3차원 레이저 측정, Point 데이터의 생성, Registration & Merging, Polygon 데이터의 생성, Surface 데이터 생성의 과정을 거쳐 수행된 고건축물의 3차원 모델링 결과에 대하여 기술한다. 문화재의 보존 및 복원을 위한 자료 기록 및 측정에 있어서 지상 레이저스캐너를 사용한 고건축물의 데이터베이스 구축기술은 문화유산의 복원 및 관련분야에 커다란 영향력으로 자리매김할 수 있을 것으로 사료된다.

  • PDF

MFC 센서를 이용한 응력 확대 계수 측정에 관한 연구 (A Study of Stress Intensity Factors using Micro Fiber Composite Sensors)

  • 오동진;김명현
    • Journal of Welding and Joining
    • /
    • 제29권3호
    • /
    • pp.76-81
    • /
    • 2011
  • Recently, the structural failures due to fatigue occur frequently with the increase of size of ships and offshore structures. In this respect, the assessment of fatigue life and the residual strength are very important. Currently, the smart materials technology has demonstrated a variety of possibilities for a diagnosis of structural strength and structural health condition for large structures. The benefits and feature of the MFC sensor are more flexible, durable and reliable than conventional smart material. In this study, Micro Fiber Composite (MFC) sensor for the measurement of stress intensity factor (SIF) of two dimensional cracks induced in a structure is developed. Two MFC sensors are placed in the vicinity of the crack tip close to each other with the crack tip in between them. The SIFs of Mode I($K_I$) as well as of Mode II($K_{II}$) based on the piezoelectric constitutive law and fracture mechanics are calculated. In this study, the SIF values measured by MFC sensors are compared with the theoretical results and measured value.

종합병원 외래진료부의 공간구성과 규모계획에 관한 조사연구 - 최근 계획된 500병상 이상 규모의 종합병원을 중심으로 - (A Study on the Spatial Organization of Outpatient Department in General Hospital - Focused on the Latest Planned General Hospital of Scale more than 500 Beds -)

  • 손재원;이특구
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제13권2호
    • /
    • pp.53-60
    • /
    • 2007
  • Various changes in medical environments including growing elderly population, chronic diseases, deepening competition among hospitals since opening to foreign medical service, economic strategy for improvement of profit system have caused hospitals to be specialized. In this backgrounds, the purpose of this study is to receive basic data for architectural planning on the spatial organization of outpatient department in general hospital. The results of this study were as follows; First, major changes of outpatient department in general hospital are composed of 'co-work in medical examination and treatment', 'decentralization of diagnosis and treatment(D/T)' and 'patient-oriented medical service'. Changes by co-work system include appearance of medical offices for co-work, activation of specialized clinics, grouping of E/T section for outpatient and various types of specialized centers. Second, the grouping of E/T sections means the modification of E/T system and organization in general hospitals, and a new spatial organization will be needed. Third, the types of specialized centers are getting varied. they are classified into several types including disease-resource, social stratum-resource, human organ-resource, health-resource, rehabilitation-resource, alternative medical center and so on.

  • PDF