• Title/Summary/Keyword: dew point temperature

Search Result 133, Processing Time 0.024 seconds

Performance Test of Low Temperature Regeneration Polymeric Desiccant Rotor (고분자 제습로터의 저온재생 성능시험)

  • Lee, Jin-Kyo;Lee, Dae-Young;Oh, Myung-Do
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.629-632
    • /
    • 2009
  • The polymeric desiccant rotor is made from the super absorbent polymer by ion modification. The moisture sorption capacity of the super desiccant polymer(SDP) is 4 to 5 times larger than those of common desiccant meterials such as silica gel or zeolite. It is also known that SDP can be regenerated even at the relatively low temperature. To fabricate the desiccant rotor, firstly the SDP was laminated by coating the SDP on polyethylene sheet. Then corrugated and rolled up into a rotor. The diameter, the depth, the dimensions of the corrugated channel, etc. were pre-determined from numerical simulation on the heat and mass transfer in the desiccant rotor. The dehumidification performance was tested in a climate chamber. The relevant tests were carried out at the process air inlet temperature of $32^{\circ}C$, the regeneration air inlet temperature of $60^{\circ}C$ and the inlet dew-point temperature of both the process air and the regeneration air of $18.5^{\circ}C$, when the rotation period is long, the moisture sorption is not effective. In the desiccant rotor developed in this study, the optimum rotation period is found about 350s at the regeneration temperature of $60^{\circ}C$. It was found from further experiments that the optimum rotation tends to decreases as the regeneration temperature increases. Meanwhile, the outlet temperature of the process air deceases monotonically as the rotation period increases.

  • PDF

Thermal Resistance and Condensation in the Light-frame Timber Wall Structures with Various Composition of Insulation Layers

  • Jang, Sang Sik;Lee, Hyoung Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.47 no.4
    • /
    • pp.533-542
    • /
    • 2019
  • As energy costs increase, more people has become interested on energy efficiency and savings in residential buildings. The two main subjects related to energy in residential buildings are insulation and condensation. There are two approaches to prevent condensation; increasing air tightness and maintaining the temperature inside of the wall structure over the dew point, which is in turn related to insulation. Even though the Korean government has highlighted the importance of energy efficiency for residential housings, and in spite of the customers' demands, the timber construction industry is still using conventional light-frame construction without even trying to improve energy efficiency. In this study, various types and combinations of wall structures were tested under cold outdoor and warm indoor temperatures to analyse the temperature gradients and to determine the possible sites of condensation in the wall structures. In addition to the experimental tests, three theoretical models were developed and their estimations of temperature change through the wall structure were compared with the actual measurements to evaluate accuracy of the models. The results of the three models agree relatively well with the experimental values, indicating that they can be used to estimate temperature changes in wall structures. The theoretical analysis of different insulation layers' combinations show that condensation may occur within the mid-layer in the conventional light-frame wall structures for any combination of inner-, mid-, and outer-layers of insulation. Therefore, it can be concluded that the addition of an inner and outer insulation layer or increasing the thickness of insulation may not be adequate to prevent condensation in the wall structure without preventing penetration of warm moist air into the wall structure.

The Generation of Typical Meteorological Year for Research of the Solar Energy on the Korean Peninsula (한반도 태양에너지 연구를 위한 일사량 자료의 TMY 구축)

  • Jee, Joon-Bum;Lee, Seung-Woo;Choi, Young-Jean;Lee, Kyu-Tae
    • New & Renewable Energy
    • /
    • v.8 no.2
    • /
    • pp.14-23
    • /
    • 2012
  • The TMY (Typical Meteorological Year) for the solar energy study is generated using observation data with 22 solar sites from KMA (Korea Meteorological Administration) during 11 years (2000-2010). The meteorological data for calculation the TMY are used solar radiation, temperature, dew point temperature, wind speed and humidity data. And the TMY is calculated to apply the FS (Finkelstein and Schafer) statistics and RMSE (Root Mean Squared Error) methods. FS statistics performed with each point and each variable and then selected top five candidate TMM months with statistical analysis and normalization. Finally TMY is generated to select the highest TMM score with evaluation the average errors for the 22 whole points. The TMY data is represented average state and long time variations with 22 sites and meteorological data. When TMY validated with the 11-year daily solar radiation data, the correlation coefficient was about 0.40 and the highest value is 0.57 in April and the lowest value is 0.23 in May. Mean monthly solar radiation of TMY is 411.72 MJ which is 4 MJ higher than original data. Average correlation coefficient is 0.71, the lowest correlation is 0.43 in May and the highest correlation is 0.90 in January. Accumulated annual solar radiation by TMY have higher value in south coast and southwestern region and have relatively low in middle regions. And also, differences between TMY and 11-year mean of is distributed lower 100 MJ in Kyeongbuk, higher 200 MJ in Jeju and higher 125 MJ in Jeonbuk and Jeonnam, respectively.

A Study on Performance Characteristics of a Dehumidifier with Multi-layer Type Heat Exchangers Varying Frontal Air Velocity (다층형 열교환기를 이용한 제습기의 전면 풍속 변화에 따른 성능 특성에 관한 연구)

  • Ku, Hak-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.7
    • /
    • pp.2323-2327
    • /
    • 2010
  • The experimental apparatus consists of dehumidifier with multi-layer type heat exchangers to remove the moisture from automatic equipments, semiconductors, and manufacturing processes under the low temperature environment, and chemical production lines which are likely to take moisture. The major components of this system are four evaporators with different fin pitch, two compressors, two condensers and an expansion valve. In this study, the performance characteristics of dehumidifier is analyzed by the variations of frontal air velocity in the first heat exchanger(evaporator). The cooling capacity of each heat exchanger is acquired by the enthalpy calculating from measuring point of temperature and relative humidity of the first heat exchanger from 1.0m/s to 4.0m/s with increasing interval 0.5m/s, and the front air velocity. As a result, it is found that cooling capacity of the first heat exchanger showed the best cooling capacity when its frontal air velocity is 2.0 m/s.

Atmospheric Characteristics of Fog Incidents at the Nakdong River : Case Study in Gangjeong-Goryeong Weir (낙동강 유역 안개 발생시 기상 특성: 강정고령보 사례를 중심으로)

  • Park, Jun Sang;Lim, Yun-Kyu;Kim, Kyu Rang;Cho, Changbum;Jang, Jun Yeong;Kang, Misun;Kim, Baek-Jo
    • Journal of Environmental Science International
    • /
    • v.24 no.5
    • /
    • pp.657-670
    • /
    • 2015
  • Visibility and Automatic Weather System(AWS) data near Nakdong river were analyzed to characterize fog formation during 2012-2013. The temperature was lower than its nearby city - Daegu, whereas the humidity was higher than the city. 157 fog events were observed in total during the 2 year period. About 65% of the events occurred in fall (September, October, and November) followed by winter, summer, and spring. 94 early morning fog events of longer than 30 minutes occurred when south westerly wind speed was lower than 2 m/s. During these events, the water temperature was highest followed by soil surface and air temperatures due to the advection of cold and humid air from nearby hill. The observed fog events were categorized using a fog-type classification algorithm, which used surface cooling, wind speed threshold, rate of change of air temperature and dew point temperature. As a result, frontal fog observed 6 times, radiation 4, advection 13, and evaporation 66. The evaporation fog in the study area lasted longer than other reports. It is due to the interactions of cold air drainage flow and warm surface in addition to the evaporation from the water surface. In particular, more than 60% of the evaporation fog events were accompanied with cold air flows over the wet and warm surface. Therefore, it is needed for the identification of the inland fog mechanism to evaluate the impacts of nearby topography and land cover as well as water body.

Relationship between Abundances of Kaloula borealis and Meteorological Factors based on Habitat Features (서식지 특성에 따른 맹꽁이 개체수와 기상요인과의 관계 분석)

  • Rho, Paikho
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.19 no.3
    • /
    • pp.103-119
    • /
    • 2016
  • This study aims to assess habitat feature on the large-scale spawning ground of the Boreal Digging Frog Kaloula borealis in Daemyung retarding basin of Daegu, and to analyze the relationships between species abundance and meteorological factors for each habitat. Fifty-seven(57) pitfalls were installed to collect species abundance of 4 survey regions, and high-resolution satellite image, soil sampling equipment, digital topographic map, and GPS were used to develop habitat features such as terrain, soil, vegetation, human disturbance. The analysis shows that the frog is most abundant in sloped region with densely herbaceous cover in southern part of the retarding basin. In the breeding season, lowland regions, where Phragmites communis and P. japonica dominant wetlands and temporary ponds distributed, are heavily concentrated by the species for spawning and foraging. Located in between legally protected Dalsung wetands and lowland regions of the retarding basin, riverine natural levee is ecologically important area as core habitat for Kaloula borealis, and high number of individuals were detected both breeding and non-breeding seasons. Temperate- and pressure-related meteorological elements are selected as statistically significant variables in species abundance of non-breeding season in lowland and highland regions. However, in sloped regions, only a few variables are statistically significant during non-breeding season. Moreover, breeding activities in sloped regions are statistically significant with minimum temperature, grass minimum temperature, dew point temperature, and vapor pressure. Significant meteorological factors with habitat features are effectively applied to establish species conservation strategy of the retarding basin and to construct for avoiding massive road-kills on neighboring roads of the study sites, particularly post-breeding movements from spawning to burrowing areas.

Development of a Drain-Type Electronic Dehumidifier Using Thermoelectric Element (열전소자를 이용한 배수형 전자제습기 개발)

  • Kang, Deok-Hong;Kim, Seong-Hwan;Kim, Ki-Hong
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3524-3528
    • /
    • 2007
  • In this study, the Peltier effect was applied to eliminate moistures in the air enclosed by a cabinet. We have developed the new electronic dehumidifier which has a new function of automatically evaporating the condensed water inner cabinet into the outside air. To obtain this function, the processes of dehumidification is that it condensed the moistures on the cold side heat sink and drained it into the hot side heat sink by the both gravitational and capillary forces and the droplets on the hot side heat sink surface was evaporated into the air outside the cabinet by the heat conducted through the hot side heat sink surface and the forced heat convection through the fan for cooling hot side heat sink. Compared to existing electronic dehumidifiers, this manufactured one showed a good performance that the electric power consumption for the same dehumidifying quantity was reduced by 50% compared with that of existing ones.

  • PDF

Status of PM10 as an air pollutant and prediction using meteorological indexes in Shiraz, Iran

  • Masoudi, Masoud;Poor, Neda Rajai;Ordibeheshti, Fatemeh
    • Advances in environmental research
    • /
    • v.7 no.2
    • /
    • pp.109-120
    • /
    • 2018
  • In the present study research air quality analyses for $PM_{10}$, were conducted in Shiraz, a city in the south of Iran. The measurements were taken from 2011 through 2012 in two different locations to prepare average data in the city. The averages concentrations were calculated for every 24 hours, each month and each season. Results showed that the highest concentration of $PM_{10}$ occurs generally in the night while the least concentration was found at the afternoon. Monthly concentrations of $PM_{10}$ showed highest value in August, while least value was found in January. The seasonal concentrations showed the least amounts in autumn while the highest amounts in summer. Relations between the air pollutant and some meteorological parameters were calculated statistically using the daily average data. The wind data (velocity, direction), relative humidity, temperature, sunshine periods, evaporation, dew point and rainfall were considered as independent variables. The relationships between concentration of pollutant and meteorological parameters were expressed by multiple linear regression equations for both annual and seasonal conditions SPSS software. RMSE test showed that among different prediction models, stepwise model is the best option.

An Experimental Study on the Optimization of Performance Parameter for Membrane Based Dehumidification and Air Conditioning System (분리막 제습공조 시스템의 성능변수 최적화를 위한 실험적 연구)

  • Jang, Jeachul;Kang, Eun-Chul;Jeong, Siyoung;Park, Seong-Ryong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.2
    • /
    • pp.75-80
    • /
    • 2016
  • There are three types of dehumidification systems : refrigeration dehumidification method, desiccant dehumidification method and hybrid dehumidification method. The first method involves removing moisture by condensation below the dew point, the second method involves absorption by a desiccant material and the last is an integration method. However, the refrigeration dehumidification system consumes too much power and controlling the humidity ratio is difficult. The desiccant dehumidification system uses less power but it has problems of environmental pollution. The hybrid dehumidification system has the disadvantage of a high initial cost. On the other hand, the energy consumption of the membrane based dehumidification system is lower than for the refrigeration dehumidification system. Also, it is an environmentally friendly technology. In this study, the performance parameters are evaluated for the dehumidification system using a hollow fiber membrane. Available area, duct side dry-bulb temperature, sweep gas flux (flow rate) and LMPD (Log Mean Pressure Difference) were used as the performance parameters.

The Artificial Neural Network based Electric Power Demand Forecast using a Season and Weather Informations (계절 및 날씨 정보를 이용한 인공신경망 기반 전력수요 예측 알고리즘 개발)

  • Kim, Meekyeong;Hong, Chuleui
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.1
    • /
    • pp.71-78
    • /
    • 2016
  • This paper proposes the new electric power demand forecast model which is based on an artificial neural network and considers time and weather factors. Time factors are selected by measuring the autocorrelation coefficients of load demand in summer and winter seasons. Weather factors are selected by using Pearson correlation coefficient The important weather factors are temperature and dew point because the correlation coefficients between these factors and load demand are much higher than those of the other factors such as humidities, air pressures and wind speeds. The experimental results show that the proposed model using time and seasonal weather factors improves the load demand forecasts to a great extent.