• 제목/요약/키워드: device physics

검색결과 721건 처리시간 0.025초

Properties of Photovoltaic Cell using ZnPc/C60 Double Layer Devices

  • Lee, Ho-Sik;Seo, Dae-Shik;Lee, Won-Jae;Jang, Kyung-Uk;Kim, Tae-Wan;Lee, Sung-Il
    • Transactions on Electrical and Electronic Materials
    • /
    • 제6권3호
    • /
    • pp.124-127
    • /
    • 2005
  • It has been a long time since organic solar cells were expected as a low-cost energy-conversion device. Although practical use of them has not been achieved, technological progress continues. Morphology of the materials, organic/inorganic interface, metal cathodes, molecular packing and structural properties of the donor and acceptor layers are essential for photovoltaic response. We have fabricated solar cell devices based on zinc-phthalocyanine(ZnPc) as donor(D) and fullerene$(C_60)$ as electron acceptor(A) with doped charge transport layers, and BCP and $Alq_3$ as an exciton blocking layer(EBL). We have measured the photovoltaic characteristics of the solar cell devices using the Xe lamp as a light source. We were use of $Alq_3$ layer leads to external power conversion efficiency was $2.65\%$ at illumination intensity $100\;mW/cm^2$. Also we confirmed the optimum thickness ratio of the DA hetero-junction is about 1:2.

Fabrication and Characterization of a Wrist Wearable Cuffless Pulsimeter by Using the Hall Effect Device

  • Lee, Sang-Suk;Choi, Jong-Gu;Son, Il-Ho;Kim, Keun-Ho;Nam, Dong-Hyun;Hong, You-Sik;Lee, Woo-Beom;Hwang, Do-Guwn;Rhee, Jang-Roh
    • Journal of Magnetics
    • /
    • 제16권4호
    • /
    • pp.449-452
    • /
    • 2011
  • A wrist wearable cuffless pulsimeter with a portable and small size apparatus using Hall effect is fabricated. The analysis of the pulse wave measured by the testing product of pulsimeter is done to measure the pulse rate and blood pressure. The blood pressure obtained by the puslimeter is compared with the practical values measured by electronic or mercury liquid blood pressure meters. The detail analysis of a pulse wave measured by a wrist wearable cuffless pulsimeter detecting the changes of the magnetic field can be used to develop a new diagnostic algorithm of blood pressure applying for oriental medical apparatus.

All-fiber RGB Laser Light Source of Head-up Display System for Automobile Application

  • Lee, Jonggwan;Kim, Kyungwon;Son, Seong-Jin;Kim, Bok Hyeon;Yu, Nan Ei
    • Current Optics and Photonics
    • /
    • 제4권3호
    • /
    • pp.221-228
    • /
    • 2020
  • We developed an all-fiber RGB laser light source module for application in an automobile head-up display. It is based on laser diodes and an optical fiber combiner that substantially enhances the flexibility of configuration and stability against harsh working conditions for automobiles. We coupled 13 laser diodes with optical fibers and merged them into a single output with a beam combiner device. Red (R), green (G), and blue (B) laser sources were employed to produce primary colors that were mixed into a white light output. An optical output power of approximately 1.5 W was achieved, and the color balance of the output lights was assessed based on the CIE 1931 color space. The optical output power was shown to be stable for over 160 h within an optical fluctuation of less than 0.27%.

Baffle design and test for wide-field off-axis telescopes

  • 김상혁;박수종;장성혁;김권희;양순철;;허명상;임명신
    • 천문학회보
    • /
    • 제38권1호
    • /
    • pp.72.2-72.2
    • /
    • 2013
  • An off-axis telescope has several advantages in optical performance comparing with a conventional on-axis telescope. However, in general, an off-axis telescope has a narrow field of view due to the linear astigmatism caused by the asymmetric structure. It was shown in the previous work that the linear astigmatism can be eliminated by properly configuring parameters in a confocal off-axis reflector system. Furthermore, the third order aberrations of a confocal off-axis telescope can be minimized by optimizing the shape of the mirrors. Despite many advantages, the confocal off-axis telescopes have been evaded because of difficulties of off-axis mirror fabrication, alignment process and unaccustomed off-axis baffle design. The baffle for the off-axis telescope should be designed considering that the effects of stray lights are different because of the asymmetry of off-axis system. In this poster, the design, manufacturing, and test for the baffle and housing of an off-axis telescope are presented.

  • PDF

고출력 마그네트론 구동용 3.6 MW, $4\;{\mu}s$, 200 pps 펄스 모듈레이터 개발 (Development of a 3.6 MW, $4\;{\mu}s$, 200 pps Pulse Modulator for a High Power Magnetron)

  • 장성덕;권세진;배영순;오종석;조무현;남궁원;손윤규
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권3호
    • /
    • pp.120-126
    • /
    • 2005
  • The Korean Superconducting Tokamak Advanced Research (KSTAR) tokamak device is being constructed to perform long-pulse, high-beta, advanced tokamak fusion physics experiments. The long-pulse operation requires the non-inductive current drive system such as the Lower-Hybrid Current Drive (LHCD) system. The LHCD system drives the non-inductive plasma current by means of C-band RF with 2-MW CW power and 5-GHz frequency. For the LHCD test experiments, an RF test system is developed. It is composed of a 5-GHz, 1.5-MW pulsed magnetron and a compact pulse modulator with $4\;{\mu}s$ of pulse width. The pulse modulator provides the maximum output voltage of 45 kV and the maximum current of 90 A. It is composed of 7 stages of Pulse Forming Network (PFN), a thyratron tube (E2V, CX1191D), and a pulse transformer with 1:4 step-up ratio. In this paper, the detailed design and the performance test of the pulse modulator are presented.

Improvement of Maskless Photolithography of Bio Pattern with Single Crystalline Silicon Micromirror Array

  • Jang, Yun-Ho;Lee, Kook-Nyung;Park, Jae-Hyoung;Shin, Dong-Sik;Lee, Yoon-Sik;Kim, Yong-Kweon
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권2호
    • /
    • pp.274-279
    • /
    • 2007
  • This study focuses on the enhancement of maskless photolithography as well as the peptide synthesis application with single crystalline silicon micromirrors. A single crystalline silicon micromirror array has been designed and fabricated in order to improve its application to the peptide synthesis. A micromirror rotates about ${\pm}\;9^{\circ}$ at the pull-in voltage, which can range from 90.7 V to 115.1 V. A $210\;{\mu}m-by-210\;{\mu}m$ micromirror device with $270\;{\mu}m$ mirror pitch meets the requirements of an adequately precise separation for peptide synthesis. Synthetic 16 by 16 peptide array corresponds to the same number of micromirrors. The large size of peptide pattern and the separation facilitate biochip experiments using fluorescence assay. The peptide pattern has been synthesized on the GPTS-PEG200 surface with BSA-blocking and thereupon the background was acetylated to reject non-specific bindings. Hence, an averaged slope at the pattern edge has been distinguishably improved in comparison to patterning results from an aluminum micromirror.

Radon and thoron concentrations inside ancient Egyptian tombs at Saqqara region: Time-resolved and seasonal variation measurements

  • Salama, E.;Ehab, M.;Ruhm, W.
    • Nuclear Engineering and Technology
    • /
    • 제50권6호
    • /
    • pp.950-956
    • /
    • 2018
  • For complete assessment of inhalation doses of radon and its progeny inside the three main ancient Egyptian tombs in Saqqara, seasonal radon concentrations have been measured by using a new electronic device that allows for measurement of real-time-resolved radon concentrations. Measurements were complemented by very fast measurements of thoron concentrations, which turned out to be low. Based on these measurements, annual residence time inside these tombs and the newest International Commission on Radiological Protection-recommended radon dose conversion coefficients or seasonal effective doses were calculated. The results indicate that workers receive highest annual effective doses of up to 140 mSv, which exceeds the annual limit of 20 mSv, whereas lower values up to 15 mSv are received by guides. In contrast, much lower doses were obtained for one-time visitors of the investigated tombs. The obtained results are somewhat different but still consistent with those previously obtained by means of fixed passive dose meters at some of the investigated places. This indicates that reasonable estimates of the effective dose of radon can be also obtained from short-term radon measurements carried out only twice a year (summer and winter season). Increasing the ventilation, minimizing the working times, etc., are highly recommended to reduce the annual effective dose.

Two-Phase Magnet in the Co/Co2MnSn System

  • Kim, Tae-Wan;Yim, Hye-In;Lee, Hyun-Yong;Lee, Kyoung-Il
    • Journal of Magnetics
    • /
    • 제16권1호
    • /
    • pp.10-14
    • /
    • 2011
  • This study reports on Co/$Co_2$MnSn two-phase magnets. The Co/$Co_2$MnSn two-phase magnet has Co precipitates in a $Co_2MnSn$ Heusler alloy matrix, in which the two phases are exchange-coupled at the phase boundary. The as-casted Co/$Co_2$MnSn system, which has Co-Mn solid solution precipitates in a $Co_2$MnSn Heusler alloy matrix, showed that the Co solid solution precipitates are crystallographically coherent and there is exchange coupling at the phase boundary. To form pure Co precipitates by removal of Mn solute atoms in Co-Mn solid solution, annealing was carried out 48 hours at $870^{\circ}C$. After annealing, the low $T_c$ and low magnetization phase of the Co-Mn solid solution became a high $T_c$ and high magnetization phase of hexagonal Co.

Stiffness Comparison of Tissue Phantoms using Optical Coherence Elastography without a Load Cell

  • Chae, Yu-Gyeong;Park, Eun-Kee;Jeon, Min Yong;Jeon, Byeong-Hwan;Ahn, Yeh-Chan
    • Current Optics and Photonics
    • /
    • 제1권1호
    • /
    • pp.17-22
    • /
    • 2017
  • Mechanical property of tissue is closely related to diseases such as breast cancer, prostate cancer, cirrhosis of the liver, and atherosclerosis. Therefore measurement of tissue mechanical property is important for a better diagnosis. Ultrasound elastography has been developed as a diagnostic modality for a number of diseases that maps mechanical property of tissue. Optical coherence elastography (OCE) has a higher spatial resolution than ultrasound elastography. OCE, therefore, could be a great help for early diagnosis. In this study, we made tissue phantoms and measured their compressive moduli with a rheometer measuring the response to applied force. Uniaxial strain of the tissue phantom was also measured with OCE by using cross-correlation of speckles and compared with the results from the rheometer. In order to compare stiffness of tissue phantoms by OCE, the applied force should be measured in addition to the strain. We, however, did not use a load cell that directly measures the applied force for each sample. Instead, we utilized one silicone film (called as reference phantom) for all OCE measurements that indirectly indicated the amount of the applied force by deformation. Therefore, all measurements were based on displacement, which was natural and effective for image-based elastography such as OCE.

All-In-One Observing Software for Small Telescope

  • Han, Jimin;Pak, Soojong;Ji, Tae-Geun;Lee, Hye-In;Byeon, Seoyeon;Ahn, Hojae;Im, Myungshin
    • 천문학회보
    • /
    • 제43권2호
    • /
    • pp.57.2-57.2
    • /
    • 2018
  • In astronomical observation, sequential device control and real-time data processing are important to maximize observing efficiency. We have developed series of automatic observing software (KAOS, KHU Automatic Observing Software), e.g. KAOS30 for the 30 inch telescope in the McDonald Observatory and KAOS76 for the 76 cm telescope in the KHAO. The series consist of four packages: the DAP (Data Acquisition Package) for CCD Camera control, the TCP (Telescope Control Package) for telescope control, the AFP (Auto Focus Package) for focusing, and the SMP (Script Mode Package) for automation of sequences. In this poster, we introduce KAOS10 which is being developed for controlling a small telescope such as aperture size of 10 cm. The hardware components are the QHY8pro CCD, the QHY5-II CMOS, the iOptron CEM 25 mount, and the Stellarvue SV102ED telescope. The devices are controlled on ASCOM Platform. In addition to the previous packages (DAP, SMP, TCP), KAOS10 has QLP (Quick Look Package) and astrometry function in the TCP. QHY8pro CCD has RGB Bayer matrix and the QLP transforms RGB images into BVR images in real-time. The TCP includes astrometry function which adjusts the telescope position by comparing the image with a star catalog. In the future, We expect KAOS10 be used on the research of transient objects such as a variable star.

  • PDF