• 제목/요약/키워드: device performance

검색결과 5,958건 처리시간 0.028초

고집광 태양광 모듈용 냉각 장치의 열성능에 대한 수치 해석적 연구 (Numerical Investigation on the Thermal Performance of a Cooling Device for a CPV Module)

  • 도규형;김태훈;한용식
    • 한국태양에너지학회 논문집
    • /
    • 제35권1호
    • /
    • pp.1-8
    • /
    • 2015
  • In the present study, the effects of the heat spreader thickness and the heat sink size on the thermal performance of a cooling device for a concentrating photovoltaic (CPV) module were numerically investigated. Numerical simulation was conducted by using the simulation tool ICEPAK, commercial software based on the finite volume method. Numerical results were validated by comparing the existing experimental data. The thermal performance of a cooling device, which consisted of a heat spreader and a natural convective heat sink, was evaluated with varying the heat spreader thickness and the heat sink size. The geometric configuration of the natural convective heat sink, such as the fin height, the fin spacing, and the fin thickness, was optimized by using the existing correlation. The numerical results showed that the thermal performance of the cooling device increased as the heat spreader thickness or the heat sink size increased. Also, it was found that the spreading thermal resistance plays an important role in the thermal performance of the cooling device which has the localized heat source.

Performance Analysis of a Mixed-Flow Pump for Waterjet Propulsion

  • Ahn Jong-Woo;Kim Ki-Sup;Park Young-Ha;Kim Kyung-Youl;Oh Hyoung-Woo
    • Journal of Ship and Ocean Technology
    • /
    • 제9권2호
    • /
    • pp.11-20
    • /
    • 2005
  • A mixed-flow pump is largely applied for waterjet propulsion in high-speed vessels because of excellent cavitation performance. For the present study, we analyze the performance of mixed-flow pump, which is composed of impeller and stator. The test device for a mixed-flow pump was installed in the test section in the KRISO cavitation tunnel. The performance tests of two mixed-flow pumps were carried out with the test device at various flow rates using various nozzles. The test results agree fairly well with the predicted results by commercial CFD code. The test device is available for verification of impeller performance together with CFD analysis

단말 간 직접 통신을 위한 효율적인 동기 프리앰블 설계 및 성능비교 (Design and Performance Comparison of Synchronization Preambles for Device-to-Device Communications)

  • 김종훈;성기영;정영호
    • 한국위성정보통신학회논문지
    • /
    • 제12권1호
    • /
    • pp.125-131
    • /
    • 2017
  • 본 논문에서는 이동통신, 무인기 통신, 차량 간 통신 등에 이용될 수 있는 효율적인 단말 간 직접통신 (D2D: device-to-device)을 위한 동기 프리앰블 (preamble) 구조를 제안하고 성능을 비교한다. 단말 간 직접 통신을 위해서는 향상된 주파수 및 시간 동기 요구 성능을 만족 시킬 수 있어야 하며, 본 논문에서는 이를 위한 프리앰블 구조를 제안한다. 주파수 영역에서 하나 걸러 하나씩의 부반송파에는 신호를 전송하지 않는 대신, 나머지 부반송파에서는 심볼 당 에너지를 2배로 전송하는 제안하는 구조가 기존 LTE D2D 프리앰블 구조에 비해 주파수 옵셋 추정 성능은 유지하면서도 시간 옵셋 추정 성능을 크게 향상시킴을 확인하였다.

연료전지 냉각용 헬리컬 인서트디바이스 이중관열교환기의 열전달 성능 향상에 관한 연구 (A Study on the Improvement of Efficiency of Heat Transfer of Double Pipe Heat Exchanger with Helical Insert Device on Cooling of a Fuel Cell)

  • 조동현
    • 수산해양교육연구
    • /
    • 제27권6호
    • /
    • pp.1872-1879
    • /
    • 2015
  • The present study was conducted on the improvement of the heat transfer performance of double pipe heat exchangers with helical insert device. Double pipe heat exchangers with helical insert device were studied for improvement of the heat transfer performance of double pipe heat exchangers with helical insert device and plain double pipe heat exchangers were also studied to comparatively analyze heat transfer performance. Experimental results were derived on changes in the Reynold's numbers of the cooling water flowing in helical and plain double pipe heat exchangers and changes in the heat flux of the air. Thereafter, to verify the reliability of the experimental results, the theoretical total energy and the experimental total energy were comparatively analyzed and the following results were derived. The thermal energy of the calorie lost by the hot air and that of the calorie obtained by the cooling water were well balanced. The experiments of plain double pipe heat exchangers and double pipe heat exchangers with helical insert device were conducted under normal conditions and the theoretical overall heat transfer coefficient value and the experimental overall heat transfer coefficient value coincided well with each other. In both plain double pipe heat exchangers and double pipe heat exchangers with helical insert device, heat transfer rates increased as the cooling water flow velocity increased. Under the same experimental conditions, the heat transfer performance of double pipe heat exchangers with helical insert device was shown to be higher by approximately 1.5 times than that of plain double pipe heat exchangers.

기술 및 개인적 특성이 헬스케어 웨어러블 디바이스 수용의도에 미치는 영향에 관한 연구 (An Empirical Study on Acceptance Intention Towards Healthcare Wearable Device)

  • 이상일;유왕진;박현선;김상현
    • 한국정보시스템학회지:정보시스템연구
    • /
    • 제25권2호
    • /
    • pp.27-50
    • /
    • 2016
  • Purpose The purpose of this study is to examine the effect of the acceptance intention towards healthcare wearable device in Korea. Specifically, this study attempted to identify the relationships among the acceptance intention towards healthcare wearable device, technical characteristics and user's personal characteristic based on UTAUT(Unified Theory of Acceptance and Use of Technology) model. Design/methodology/approach For this purpose of research, we conducted against consumers who use the wearable devices and we collected data from 219 wearable device users. The analyses were conducted using SPSS and AMOS19.0 which is powerful structural equation modeling (SEM) software. Findings The main findings are as followed; First, functional diversity, wearability, trend sensitivity and health perception are significantly related to performance expectancy, while visual aesthetic and enjoyment are not significantly related. Second, performance expectancy and effort expectancy are significantly related to acceptance intention towards healthcare wearable device. Third, effort expectancy is significantly related to performance expectancy.

Performance Evaluation of SSD-Index Maintenance Schemes in IR Applications

  • Jin, Du-Seok;Jung, Hoe-Kyung
    • Journal of information and communication convergence engineering
    • /
    • 제8권4호
    • /
    • pp.377-382
    • /
    • 2010
  • With the advent of flash memory based new storage device (SSD), there is considerable interest within the computer industry in using flash memory based storage devices for many different types of application. The dynamic index structure of large text collections has been a primary issue in the Information Retrieval Applications among them. Previous studies have proven the three approaches to be effective: In- Place, merge-based index structure and a combination of both. The above-mentioned strategies have been researched with the traditional storage device (HDD) which has a constraint on how keep the contiguity of dynamic data. However, in case of the new storage device, we don' have any constraint contiguity problems due to its low access latency time. But, although the new storage device has superiority such as low access latency and improved I/O throughput speeds, it is still not well suited for traditional dynamic index structures because of the poor random write throughput in practical systems. Therefore, using the experimental performance evaluation of various index maintenance schemes on the new storage device, we propose an efficient index structure for new storage device that improves significantly the index maintenance speed without degradation of query performance.

Combination-mode BLE Device Profile for Connection & Non-connection Methods

  • Jiang, Guangqiu;Joe, Inwhee
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2016년도 춘계학술발표대회
    • /
    • pp.897-899
    • /
    • 2016
  • In recent years, BLE technology has received extensive attention and has been applied to all aspects of life. The existing BLE device has two methods, one is the connection method, and the other is a non-connection method. The representative profile of the connection method is the proximity file. The most typical example of Non-connection method BLE device is a beacon. However, they are both independent and have their own shortcomings. Connection method device can provide service for only one user, others can't use. Security performance of Non-connection method BLE device is poor and the device can't be controlled by the user. In this paper, a combination-mode BLE device profile design scheme is presented, which combines with the previous two methods, and solves the defaults. And We define a dual purpose advertising package that can be used in a normal environment as well as in a disaster environment. Finally, a unidirectional Control idea is proposed. Through performance evaluation, we found that the device has strong stability and low power consumption.

Effect of the suction plate shape on metering performance of a vacuum metering device for garlic seeds

  • Kim, Deok-Keun;Choi, Yeong-Soo;Yang, Seung-Hwan
    • 농업과학연구
    • /
    • 제47권4호
    • /
    • pp.829-844
    • /
    • 2020
  • A vacuum metering device for garlic seeds was developed, and its metering performance was tested according to the design factors. Three design factors were as follows: suction surface diameter (Edge), suction surface curvature (Type), and guide height (Guide). The suction surface curvature represents the distance between the center of the grooved suction plate and the bottom of suction plate. The metering rate and multiple metering rate were analyzed as the metering performance of the developed device with two varieties of garlic seeds: Namhae (warm region-adapted garlic) and Uiseong (cold region-adapted garlic). The best metering performance for the Namhae seeds were found with the following conditions: An Edge, Guide and Type of 40, 4, and 35 mm, respectively. In the case of the Uiseong seeds, the best conditions were as follows: An Edge, Guide and Type of 35, 4, and 30 mm, respectively. The guide height was found to be the most influential design factor on the metering performance of the metering rate and multiple rate for both Namhae seeds and Uiseong seeds. Additionally, the interaction between the area of the suction surface and the curvature of the suction surface had some effects on the multiple rate for the Uiseong seeds. It was concluded that the guide height should be 4 mm or higher so that more than 90% of the metering rate could be achieved for the tested garlic seeds with the developed metering device.

스마트 기기의 효율적인 I/O를 위한 플래시 파일 시스템 성능 분석 (Performance Analysis of Flash File System for the Efficient I/O on Smart Device)

  • 정경호;김용환;김상진;정영석;김성수
    • 대한임베디드공학회논문지
    • /
    • 제10권3호
    • /
    • pp.171-178
    • /
    • 2015
  • Recently NAND flash memory has been found to be the primary cause of low performance in the smart device. NAND flash memory is different from each other the execution time of I/O operations that flash file system is required. Therefore, it is necessary to compare and analyze the flash file system I/O performance for the efficient I/O on smart device. In this paper, it was tested and analyzing the I/O performance of the YAFFS2, JFFS2, UBIFS. Experimental results most read I/O performance is good, but the writing I/O performance is not good. For UBIFS, showed a more good I/O performance compared to other flash file system.

복합 슬릿-마찰 감쇠장치가 적용된 철근 콘크리트 특수 모멘트 저항골조의 내진성능 평가 (Seismic Performance Evaluation of Special Reinforced Concrete Moment Resisting Frames With Hybrid Slit-Friction Damper)

  • 이준호;김기철;김진구
    • 한국공간구조학회논문집
    • /
    • 제17권4호
    • /
    • pp.35-42
    • /
    • 2017
  • This study develops a new hybrid passive energy dissipation device for seismic rehabilitation of an existing structure. The device is composed of a friction damper combined with a steel plate with vertical slits as a hysteretic damper. Analytical model is developed for the device, and the capacity of the hybrid device to satisfy a given target performance is determined based on the ASCE/SEI 7-10 process. The effect of the device is verified by nonlinear dynamic analyses using seven earthquake records. The analysis results show that the dissipated inelastic energy is concentrated on the hybrid damper and the maximum interstory drift of the SMRF with damping system satisfies the requirement of the current code.