• Title/Summary/Keyword: device development

Search Result 5,578, Processing Time 0.033 seconds

Development of the Portable Weighing Scale Automatic Device for Disabled Wheelchair Users (휠체어 탑승 장애인을 위한 이동형 체중측정 자동화 장치 개발)

  • Jang, Kyung-Bae;Lee, Kyeong-Wan;Koo, Do-Hoon
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.8 no.1
    • /
    • pp.61-67
    • /
    • 2013
  • Wheelchair users have a difficulty in managing their weight because there is lack of measure systems and even though the users have the system, it costs too much. Thus, purpose of this study is for developing the portable weight scale automatic device to help wheelchair users by monitoring their weight on the wheelchairs in real time. Portable weight scale automatic device composed by four strain gauges, and the device was connected with mobile phone so that wheelchair users were able to check their weight in real time. In order to evaluate the device performance, 10 normal subjects and 10 disabled subjects participated in this study. The subjects' truth weight and measured weight by the device are compared. The weigh difference within normal subjects was $0.75{\pm}0.80kg$, and the weigh difference within disabled subjects was $1.02{\pm}0.74kg$. Difference between the truth weigh and the measured weigh were not statistically different. The reason for this error occurred is inaccuracy of the loadcell installation and calibration. If this problems get solved, the measured indicator is expected to help wheelchair users to manage their weight.

Development of Micro-Ceramic Heater for Medical Application (의료용 소형 세라믹스 히터 소자의 개발)

  • Lee, Seung-Min;Lee, Kwang-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.4
    • /
    • pp.219-229
    • /
    • 2022
  • In this study, we propose a miniaturized micro-ceramic heater device. After screen-printing a silver paste between pre-sintered two aluminum oxide plates to integrate a heating circuit, the device was fabricated through a low-temperature sintering process. In order to configure the optimal heating circuit integration condition, the output current evaluation and heating test were performed according to the number of screen prints of the silver paste at various voltages. A silver paste-based heating circuit printed with a line width of 200 ㎛ and a thickness of 60 ㎛ was successfully integrated on a pre-sintered alumina substrate through a low-temperature sintering process. In the case of the 5 times printed device, the thermal response showed a response rate of 18.19 ℃/sec. To demonstrate feasibility of the proposed device in the medical field, such as bio-tissue suturing and hemostasis, a voltage was applied to pig tissue in the device to test tissue change due to heat generated from the device. These results show the possibility that the proposed small ceramic heater could be used in the medical field based on its excellent temperature response.

Feasibility Study of the Development of Guiderail-type Window Cleaning Equipment (가이드레일형 유리창 청소 장치 개발의 타당성 분석)

  • Kim, Kyoon-tai;Jun, Young-Hun;Shin, Eun-Young
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.85-86
    • /
    • 2016
  • Recently, needs for the window cleaning for 2~5 stories in a building has been increased but existing window cleaning work by workers is not easy to clean the windows. Therefore a demand for development of alternative techniques have been raised. The purpose of this study is to analyze feasibility of development of the guide rail-type cleaning device for cleaning window for the lower stories. For this, we analyze the status of the job, such as risk, limitations of by workers and examine the potential producer needs through interviewing field experts of the cleaning work. Futhermore, we define the required features of the window cleaning device and proposed the validity of the relised device development of the function.

  • PDF

Development of connection device for underground low voltage cable of manhole and handhole (맨홀용 및 핸드홀용 지중 저압케이블 접속장치 개발)

  • Lee, K.J.;Lee, E.J.;Joo, J.M.;Yu, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1056-1058
    • /
    • 2005
  • It shows a tendency to increase rapidly underground of the city due to the build up of the large residential districts with industrial development, so there is required the development of the connection device for underground low voltage cable with high quality & convenient for use with consideration for installation condition of the underground. Hence, We will have the development of the connection device for underground low voltage cable, which is made waterproof perfectly under the flood of the underground for the long time, is convenient for use in spite of narrow area such as manhole or handhole, and can be able to prevent the release by the vibration.

  • PDF

On the Untact ICT based New Concept Storage Device Design by Interworking SysML and CAD Data to Improve the Development Efficiency

  • Kim, Myung Sung;Park, Jae Min;Kim, Young Min
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.14 no.3
    • /
    • pp.258-269
    • /
    • 2022
  • In these days, innovative functions are required to unmanned parcel delivery lockers. As non-face-to-face transactions become the center due to the recent COVID-19 pandemic, many problem occurs in society such as theft crimes and lack of loading space. Therefore, New concept storage device is developed in korea. It has the functions that minimizes empty spaces by using the internal transport device to enable efficient space loading and refrigerate goods such as foods. In order to systematically approach the system design of the unmanned parcel delivery lockers which is the new function is applied, We applied model-based system engineering to improve the development efficiency and use a system modeling language to express the system. We conducted interworking research of CAD data including system modeling and design data. it is expected that this method will increase the effective development efficiency such as maintenance traceability and reduction of development period and cost.

The Design & Analysis of Pulse Separation Device with Thermal Barrier Type for Dual Pulse Rocket Motor (이중펄스 로켓모타의 격막형 펄스분리장치 설계 및 성능평가)

  • Kim, Jinyong;Kwon, Taeha;Lee, Wonbok;Cho, Wonman;Lee, Bangeop;Jung, Gyoodong;Rhee, Youngwoo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.93-99
    • /
    • 2015
  • The dual pulse rocket motor(DPRM) distributes the propellant energy effectively via pulse separation device(PSD) to improve the range and terminal velocity of the missile. There are two types of PSD such as bulk head type and thermal barrier type. A subscale thermal barrier type DPRM was designed, manufactured, and tested. The results showed good understanding of the characteristics of the PSD and will be applied to the design of the full scale DPRM.

On-site Evaluation of Rainwater Harvesting Device for Securing Irrigation Water in Small Fields (소규모 밭 관개용수 확보를 위한 소류천 빗물 집수장치의 현장 평가)

  • Choi, Yonghun;Kim, Youngjin;Kim, Minyoung;Jeon, Jonggil
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.60 no.1
    • /
    • pp.31-36
    • /
    • 2018
  • A rainwater harvesting device was developed for runoff flow harvesting in a small stream or channel and its performance was evaluated in small fields. The rainwater harvesting device has slits on its side of cylindrical volume in 15 cm diameter and 70 cm length, which is designed to increase its water flow harvesting capacity. The maximum collectable water quantity was about 0.0022 ton/sec (130 L/min). Rainwater harvesting device were installed in two locations (P1, P2). P1 is a point for rainfall runoff flow harvesting. P2 is a point for ordinary flow harvesting. During this study, total rainfall depth was 334.5 mm. Runoff of 1,722 ton and 7,984 ton occurred in P1 and P2, and 273 ton and 125 ton were collected by this rainwater harvesting device. Harvesting efficiency was calculated as 15.85 % and 1.57 % in P1 and P2. Clogging of screen filter media in the cylinder due to soil and suspended solids has lowered the harvesting efficiency. However, it was possible to harvest 30 ton/month of rainwater harvesting and it is expected that it will help to solve short-term water shortage.

Mechanical Properties of TiN and DLC coated Rod for Pedicle Screw System (TiN 및 DLC 코팅된 척추용 나사못 시스템 Rod의 기계적 특성 분석)

  • Kang, Kwan-Su;Jung, Tae-Gon;Yang, Jae-Woong;Woo, Su-Heon;Park, Tea-Hyun;Jeong, Yong-Hoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.50 no.3
    • /
    • pp.183-191
    • /
    • 2017
  • In this study, surface morphology and mechanical property of TiN and DLC coated pedicle screw have been investigated by field-emission scanning electron microscopy, energy dispersive X-ray spectroscopy, X-ray diffraction, vickers hardness test, axial gripping, and axial torsional gripping capacity test. From the EDS and XRD results, the composition and crystal structure of TiN and DLC coated surface were verified. The hardness value was increased by TIN and DLC coating, and the DLC coating surface has the highest value. The gripping capacity also showed higher value for TiN and DLC coated specimen than that of non-coated (Ti alloy) surface. The surface morphology of gripping tested specimen showed rougher scratched surface from Ti alloy than TiN and DLC coated layer.

Flexible Microelectronics; High-Resolution Active-Matrix Electrophoretic Displays

  • Miyazaki, Atsushi;Kawai, Hideyuki;Miyasaka, Mitsutoshi;Nebashi, Satoshi;Shimoda, Tatsuya;McCreary, Michael
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.575-579
    • /
    • 2005
  • A beautiful, flexible active-matrix electrophoretic display (AM-EPD) device is reported. The flexible AM-EPD device has a $40.0{\times}30.0\;mm^2$ display area, measures about 0.27 mm in thickness, weighs about 0.45 g and possesses only 20 external connections. The flexible AM-EPD device displays clear black-and-white images with 5 gray-scales on $160{\times}120$ pixels. The display is free from residual image problems, because we use an area-gray-scale method on $320{\times}240$ EPD elements, each of which is driven with binary signals. Each pixel consists of 4 EPD elements. In addition, since the response time of the electrophoretic material is as long as approximately 400 ms and since the display possesses a large number of EPD elements, we have developed a special driving method suitable for changing EPD images comfortably. A complete image is formed on the AM-EPD device, consisting of a reset frame and several, typically 6, image frames.

  • PDF

Development and Verification of Wireless Check-up System of POD for Captive Flight Test (탑재비행시험용 POD 무선 점검 시스템 개발 및 검증)

  • Ko, Myoungjun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.24 no.2
    • /
    • pp.204-210
    • /
    • 2021
  • In this paper, we studied a method of wirelessly checking up the POD for captive flight tests which is performed during the development of guided weapons systems. The wireless power transfer module, the power distribution device, and the battery pack were designed to wirelessly power the captive flight test POD, and the communication device was designed to enable wireless communication between the POD and the check-up device. The communication device was designed to enable WiFi, IR communication, and laser diode communication, so that various communication methods could be tested. Through the performance test, it was confirmed that power was stably supplied to the captive flight test POD, and the wireless communication performance was verified by measuring the delay time and error rate. As a result, by using our system the POD check-up for the captive flight test was performed wirelessly and the data of the captive equipment could be obtained effectively.