• Title/Summary/Keyword: device degradation

Search Result 474, Processing Time 0.029 seconds

A study on the RF receiving system design and on the performance improvement for PCS mobile station (개인휴대통신을 위한 이동국 RF 수신시스템의 설계 및 성능개선에 관한 연구)

  • 오정일;천종훈
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.34C no.11
    • /
    • pp.66-75
    • /
    • 1997
  • We derive the system design parameters to implement the receiving system for the PCS mobile station to satisfy the J-sTD-018 which is the PCS mobile station(MS) minimum performance. Also we analyze the system performance and intermodulation spurious due to the values of a device cause the system performance degradation, is proposed. The simulation shows the receiver's maximum system noise figure to satisfy the receiver selectivity is approximately 11 dB. While the MS noise figure is 10dB with system margin 1 dB, the minimum selectivity is -71 dB at 1.25MHz frequency offset from the carrier frequency. And the input 3rd order intercept point of the MS class I and the MS class II~V is -9.5 dBm and -14dBm respectively. When the interference power level at the receiver is small, the receiver has better performance as we increase the gain of the LNA. However, when the interference level at the receiver is large, the receiver performance is heavily affected by the spurious as we increase the gain of the LNA. Thus, we proved the effectiveness of the LNA On/Off switching technique as to reduce the effect of the spurious.

  • PDF

Development of Test Method for Flat Panel Display Life Time Prediction during Atmospheric Particle Exposure (평판디스플레이의 대기중 분진농도에 따른 수명예측 시험방법 개발)

  • Yoo, Dong-Hyun;Lee, Gun-Ho;Choi, Jung-Uk;Ahn, Kang-Ho
    • Journal of the Semiconductor & Display Technology
    • /
    • v.12 no.4
    • /
    • pp.45-48
    • /
    • 2013
  • The electronic device, such as flat panel display (FPD), is very important in our life as a means of communication between humans. Liquid crystal display (LCD), which is categorized as a flat panel display, has been used in many display products, especially in TV industry. An LED TV is composed of several electrical components, such as liquid critical module (LCM), analog to digital convertor (AD), power supplier, and inverter board. These modules are very vulnerable to particulate contamination, and causing malfunction or visibility degradation. In this study, we developed a test method for prediction of LCM's lifetime. The test system consists of carbon particle generation flame, dilution system, test chamber, and particle concentration monitoring instrument. Since the carbon particles are the most abundant in the atmosphere and easily absorb light, soot particles are used as a challenging material for this test. The concentration of generated soot particles is set around 4,000,000 #/cc, which is 400 times higher than that of usual atmospheric particles. Through this experiment, we deduced the relationship between the dust concentration and life time of the test specimen.

Device and Circuit Performance Issues with Deeply Scaled High-K MOS Transistors

  • Rao, V. Ramgopal;Mohapatra, Nihar R.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.4 no.1
    • /
    • pp.52-62
    • /
    • 2004
  • In this paper we look at the effect of Fringe-Enhanced-Barrier-lowering (FEBL) for high-K dielectric MOSFETs and the dependence of FEBL on various technological parameters (spacer dielectrics, overlap length, dielectric stack, S/D junction depth and dielectric thickness). We show that FEBL needs to be contained in order to maintain the performance advantage with scaled high-K dielectric MOSFETs. The degradation in high-K dielectric MOSFETs is also identified as due to the additional coupling between the drain-to-source that occurs through the gate insulator, when the gate dielectric constant is significantly higher than the silicon dielectric constant. The technology parameters required to minimize the coupling through the high-K dielectric are identified. It is also shown that gate dielectric stack with a low-K material as bottom layer (very thin $SiO_2$ or oxy-nitride) will be helpful in minimizing FEBL. The circuit performance issues with high-K MOS transistors are also analyzed in this paper. An optimum range of values for the dielectric constant has been identified from the delay and the energy dissipation point of view. The dependence of the optimum K for different technology generations has been discussed. Circuit models for the parasitic capacitances in high-K transistors, by incorporating the fringing effects, have been presented.

Evaluation of In Vitro Release Profiles of Fentanyl-Loaded PLGA Oligomer Microspheres

  • Gilson Khang;Seo, Sun-Ah;Park, Hak-Soo;John M. Rhee;Lee, Hai-Bang
    • Macromolecular Research
    • /
    • v.10 no.5
    • /
    • pp.246-252
    • /
    • 2002
  • In order to the development of the delivery device of long-acting local anesthetics for postoperative analgesia and control of chronic pain of cancer patient, fentnyl-loaded poly (L-lactide-co-glycolido) (PLGA, molecular weight, 5,000 g/mole; 50 : 50 mole ratio by lactide to glycolide) microspheres (FMS) were studied. FMS were prepared by an emulsion solvent-evaporation method. The influence of several preparation parameters such as initial drug loading, PLGA concentration, emulsifier concentration, oil phase volume, and fabrication temperature has been investigated on the fentanyl release profiles. Generally, the drug showed the biphasic release patterns, with an initial diffusion followed by a lag period before the onset of the degradation phase, but there was no lag time in our system. Fentanyl was slowly released from FMS over 10 days in vitro with a quasi-zero order property. The release rate increased with increasing drug loading as well as decreasing polymer concentration with relatively small initial burst effect. From the results, FMS may be a good formulation to deliver the anesthetic for the treatment of chronic pain.

A new method for monitoring an OLED panel for lighting by sensing the wave-guided light

  • Han, Jun-Han;Moon, Jaehyun;Shin, Jin-Wook;Joo, Chul Woong;Cho, Doo-Hee;Hwang, Joohyun;Huh, Jin Woo;Chu, Hye Yong;Lee, Jeong-Ik
    • Journal of Information Display
    • /
    • v.13 no.3
    • /
    • pp.119-123
    • /
    • 2012
  • In this work, we report on a new monitoring method for an organic light-emitting diode (OLED) panel for lighting by optical sensing of the wave-guided light in the substrate. Using microlens array films, the wave-guided light was extracted into the edge or back side of the panel to be monitored by a photodiode. The luminance of the extracted light was measured as linearly proportional to the front light. Thus, by converting the extracted light into photo voltage, monitoring the luminance change occurring in the OLED is possible. Based on the results and concepts, we have proposed a photodiode-equipped driving circuit which can generate compensated driving current for uniform luminance of OLED panels.

The Improved Power Supply for APD and Efficiently Designed Cylindric Micro-lens for a Wireless Optical Transmission System (무선 광 전송용 APD 전력 공급기와 원통형 레이저형상 보정용 마이크로 렌즈 기술)

  • KIM, MAN HO
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.11
    • /
    • pp.654-659
    • /
    • 2005
  • An improved power supply for APD(Avalanche Photo Diode) with a received optical power monitoring circuit allows the received optical power increase temporary without of the degradation of the electrical signal. For the cost reduction and simple fabrication, an improved power supply has been proposed that it was designed for driving a APD as a receiving device of a wireless optical transmission system. It was demonstrated that it was possible to improve a dynamic range by compensating the temperature coefficient of the APD up to 1.0 V/$^{\circ}C$ through the power supply. Also, for an efficient transmission at the receiver end, a simple structure of a single cylindrical micro-lens configuration was used in conjunction with the laser diode to partially compensate a laser beam ellipticity. For this purpose, an astigmatism introduced by the micro-lens is utilized for the additional compensation of the beam ellipticity at the receiver end. In this paper, it is demonstrated that an efficient beam shaping is realized by using the proposed configuration consisting of the single lens attached to the laser diode.

Public Sector Reform and Industrial Relations: the case of Britain (공공부문 개혁과 노사관계: 영국의 최근 사례)

  • Park, Duck Jay
    • Journal of Labour Economics
    • /
    • v.25 no.2
    • /
    • pp.79-107
    • /
    • 2002
  • Britain's public services, especially health service and secondary education are in disarray. The current British government adopted the public-private partnership(PPP) as a major device to bring about public sector reform. In principle, PPPs could be used to outsource all sorts of public services, helping to raise standards by extending choice and competition. Up to now, however, they have been focused mainly on a relatively limited range of ancillary services related to new buildings and their subsequent operation. The unions, especially the unions covering the public sector employees are antagonistic to the PPPs. The unions have been opposing privatizing or resecting of any part of the public services, as these apt to lead insecurity of employment and degradation of working conditions of their members. Most of the union leaders consider that PPPs are 'privatization by stealth'. Even in Britain, which has a long history of trade union movements, to persuade the unions to co-operate to the reform policy has been extremely difficult. To succeed in public sector reform, the government, be it Korean or British, needs strong leadership, consistency in policies between various departments, and persuasive ability to overcome the opposition from the vested-interest group.

  • PDF

Micro-vibration Isolation Performance of X-band Antenna using Blade Gear (블레이드 기어를 적용한 X-밴드 안테나 미소진동 절연성능)

  • Jeon, Su-Hyeon;Kwon, Seong-Cheol;Kim, Tae-Hong;Kim, Yong-Hoon;Oh, Hyun-Ung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.893-899
    • /
    • 2014
  • X-band antenna has been widely used to effectively transmit the high resolution image data from the observation satellite to the ground station. To achieve above mission, X-band antenna is mainly composed of the 2-axis gimbal system using stepping motors and gears. However, the micro-vibration induced by the stepping motor actuation and the imperfect gear teeth alignment during this on-orbit operation is the main source of image quality degradation. In this paper, X-band antenna combined with a blade gear for micro-vibration isolation was suggested and investigated. The structural safety of the blade gear with low rotational stiffness was confirmed by structure analysis based on the derived torque budget. The isolation performance of the X-band antenna with the blade gear was verified through micro-vibration measurement test using the dedicated micro-vibration measurement device proposed in this study.

  • PDF

A Study on Optimization of The Concentration of Cutting Oil to be used for Cutting (절삭가공(切削加工)에 사용(使用)되는 절삭유(切削油)의 농도최적화(濃度最適化)에 관(關)한 연구(硏究))

  • Kim, Gue-Tae;Kim, Won-Il
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.16 no.3
    • /
    • pp.95-102
    • /
    • 2013
  • It is indispensable to modern society metal processing since the industrialized rapidly, but it is a metalworking cutting fluid immediately. In addition, this means selecting a emulsion on the basis of quality criteria processing method, the material of the material, cutting depth, cutting speed, Djourou fence Liang, and surface roughness, cutting oil, the shape of the device based on the emulsion, I will be the structure of the tank, filtration equipment also changes. In particular, acting bacteria is now breeding in response to the passage of time due to metal ion degradation due to heat generated hydraulic fluid leakage, humidity tung, during processing, seep from processing material at the time of processing the water-soluble cutting oil for generating the malodor by dropping significantly the performance of the cutting oil to corruption from, sometimes by introducing various additives to suppress spoilage in advance. In this study, we expect the effect of the cost reduction in the extension of fluid replacement cycle through the application of the management apparatus and deep understanding in the management of cutting fluid, the working environment through the understanding and interest of workers in the production site more than anything I try to become useful for the improvement.

Condition Parameter-based On-line Performance Reliability (상태 파라메터 기반의 온라인 성능 신뢰도)

  • Kim, Yon-Soo;Chung, Young-Bae
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.30 no.3
    • /
    • pp.103-108
    • /
    • 2007
  • This paper presents the conceptual framework for estimating and predicting system's susceptibility to failure as function of condition parameter value which is representing the current status of performance measure using on-line performance reliability. The performance of such system depends on one parameter with a probability distribution that degrades with time gracefully. Performance reliability represents the probability that physical performance will remain satisfactory over a finite period of time or usage cycles in the future. An empirical physical performance function is constructed to incorporate explanatory variables (operating and environmental conditions) over a time or usage dimension. This function enables one to model device performance and the associated classical reliability measures simultaneously, in the performance domain and time domain. The conditional performance reliability structure developed represents a tool to predict system performance over time or usage for next usage period. By enabling such a framework, it can bring us more efficient planning and execution in system's operation control as well as maintenance to reduce costs and/or increase profits.