• Title/Summary/Keyword: deviation of distance

Search Result 446, Processing Time 0.023 seconds

Estimation of Monthly Precipitation in North Korea Using PRISM and Digital Elevation Model (PRISM과 상세 지형정보에 근거한 북한지역 강수량 분포 추정)

  • Kim, Dae-Jun;Yun, Jin-I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.13 no.1
    • /
    • pp.35-40
    • /
    • 2011
  • While high-definition precipitation maps with a 270 m spatial resolution are available for South Korea, there is little information on geospatial availability of precipitation water for the famine - plagued North Korea. The restricted data access and sparse observations prohibit application of the widely used PRISM (Parameter-elevation Regressions on Independent Slopes Model) to North Korea for fine-resolution mapping of precipitation. A hybrid method which complements the PRISM grid with a sub-grid scale elevation function is suggested to estimate precipitation for remote areas with little data such as North Korea. The fine scale elevation - precipitation regressions for four sloping aspects were derived from 546 observation points in South Korea. A 'virtual' elevation surface at a 270 m grid spacing was generated by inverse distance weighed averaging of the station elevations of 78 KMA (Korea Meteorological Administration) synoptic stations. A 'real' elevation surface made up from both 78 synoptic and 468 automated weather stations (AWS) was also generated and subtracted from the virtual surface to get elevation difference at each point. The same procedure was done for monthly precipitation to get the precipitation difference at each point. A regression analysis was applied to derive the aspect - specific coefficient of precipitation change with a unit increase in elevation. The elevation difference between 'virtual' and 'real' surface was calculated for each 270m grid points across North Korea and the regression coefficients were applied to obtain the precipitation corrections for the PRISM grid. The correction terms are now added to the PRISM generated low resolution (~2.4 km) precipitation map to produce the 270 m high resolution map compatible with those available for South Korea. According to the final product, the spatial average precipitation for entire territory of North Korea is 1,196 mm for a climatological normal year (1971-2000) with standard deviation of 298 mm.

Applicability Evaluation of Multi Beam Echo Sounder for Inland Water (다중빔 음향측심기의 내수면 적용성 평가)

  • Jung, Jin Woo;Cho, Kwang Hee;Hong, Seung Seo
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.36 no.6
    • /
    • pp.629-639
    • /
    • 2018
  • In this study, the application of the single beam echosounder and multi beam echosounder was analyzed for the Youngsan river, from the Juksanbo to the Juksan bridge, length of 840m, width 230m and area $0.16km^2$. A single beam echosounder and a multi beam echosounder are mounted on an USV (Unmanned Surface Vessel), and each data is acquired. Then, TIN (Triangular Irregular Network) is created and the grid depth of 10m intervals is extracted. The grid depth of the single beam echo sounder and the grid depth of the multi beam echo sounder were overlapped to compare the two data. As a result of analysis using 5,024 data, the mean depth difference was 0.0319m and the standard deviation was 2.4095m. The river bed shape was similar to each other. If the multi-beam echo sounder is regarded as the standard, the volume difference of the stream is $161,882m^3$. With a multi-beam echo sounder installed, the operating distance increased by approximately 55% to 4595.85m, and the operating time increased by approximately 59% to approximately 47%.

Numerical Analysis of Electrical Resistance Variation according to Geometry of Underground Structure (지하매설물의 기하학적 특성에 따른 전기저항 변화에 대한 수치 해석 연구)

  • Kim, Tae Young;Ryu, Hee Hwan;Chong, Song-Hun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.44 no.1
    • /
    • pp.49-62
    • /
    • 2024
  • Reckless development of the underground by rapid urbanization causes inspection delay on replacement of existing structure and installation new facilities. However, frequent accidents occur due to deviation in construction design planned by inaccurate location information of underground structure. Meanwhile, the electrical resistivity survey, knowns as non-destructive method, is based on the difference in the electric potential of electrodes to measure the electrical resistance of ground. This method is significantly advanced with multi-electrode and deep learning for analyzing strata. However, there is no study to quantitatively assess change in electrical resistance according to geometric conditions of structures. This study evaluates changes in electrical resistance through geometric parameters of electrodes and structure. Firstly, electrical resistance numerical module is developed using generalized mesh occurring minimal errors between theoretical and numerical resistance values. Then, changes in resistances are quantitatively compared on geometric parameters including burial depth, diameter of structure, and distance electrode and structure under steady current condition. The results show that higher electrical resistance is measured for shallow depth, larger size, and proximity to the electrode. Additionally, electric potential and current density distributions are analyzed to discuss the measured electrical resistance around the terminal electrode and structure.

The Study of Genetic Diversity and Population Structure of the Korean Fleshy Shrimp, Fenneropenaeus chinensis, Using Newly Developed Microsatellite Markers (새로 개발한 미세위성체 마커를 이용한 한국 대하의 유전다양성 및 집단구조)

  • Shin, Eun-Ha;Kong, Hee Jeong;Nam, Bo-Hye;Kim, Young-Ok;Kim, Bong-Seok;Kim, Dong-Gyun;An, Cheul Min;Jung, Hyungtaek;Kim, Woo-Jin
    • Journal of Life Science
    • /
    • v.25 no.12
    • /
    • pp.1347-1353
    • /
    • 2015
  • The fleshy shrimp, Fenneropenaeus chinensis, is the family of Penaeidae and one of the most economically important marine culture species in Korea. However, its genetic characteristics have never been studied. In this study, a total of 240 wild F. chinensis individuals were collected from four locations as follows: Narodo (NRD, n = 60), Beopseongpo (BSP, n = 60), Chaesukpo (CSP, n = 60), and Cheonsuman (CSM, n = 60). Genetic variability and the relationships among four wild F. chinensis populations were analyzed using 13 newly developed microsatellite loci. Relatively high levels of genetic variability (mean allelic richness = 16.87; mean heterozygosity = 0.845) were found among localities. Among the 52 population loci, 13 showed significant deviation from the Hardy–Weinberg equilibrium. Neighbor-joining, principal coordinate, and molecular variance analyses revealed the presence of three subpopulations (NRD, CSM, BSP and CSP), which was consistent with clustering based on genetic distance. The mean observed heterozygosity values of the NRD, CSM, BSP, and CSP populations were 0.724, 0.821, 0.814, and 0.785 over all loci, respectively. These genetic variability and differentiation results of the four wild populations can be applied for future genetic improvement using selective breeding and to design suitable management guidelines for Korean F. chinensis culture.

A numerical study of the effects of the ventilation velocity on the thermal characteristics in underground utility tunnel (지하공동구 터널내 풍속 변화에 따른 열특성에 관한 수치 해석적 연구)

  • Yoo, Ji-Oh;Kim, Jin-Su;Ra, Kwang-Hoon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.1
    • /
    • pp.29-39
    • /
    • 2017
  • In this research, thermal design data such as heat transfer coefficient on the wall surface required for ventilation system design which is to prevent the temperature rise in the underground utility tunnel that three sides are adjoined with the ground was investigated in numerical analalysis. The numerical model has been devised including the tunnel lining of the underground utility tunnel in order to take account for the heat transfer in the tunnel walls. The air temperature in the tunnel, wall temperature, and the heating value through the wall based on heating value(117~468 kW/km) of the power cable installed in the tunnel and the wind speed in the tunnel(0.5~4.0 m/s) were calculated by CFD simulation. In addition, the wall heat transfer coefficient was computed from the results analysis, and the limit distance used to keep the air temperature in the tunnel stable was examined through the research. The convective heat transfer coefficient at the wall surface shows unstable pattern at the inlet area. However, it converges to a constant value beyond approximately 100 meter. The tunnel wall heat transfer coefficient is $3.1{\sim}9.16W/m^2^{\circ}C$ depending on the wind speed, and following is the dimensionless number:$Nu=1.081Re^{0.4927}({\mu}/{\mu}_w)^{0.14}$. This study has suggested the prediction model of temperature in the tunnel based on the thermal resistance analysis technique, and it is appraised that deviation can be used in the range of 3% estimation.

Spatial Interpolation of Hourly Air Temperature over Sloping Surfaces Based on a Solar Irradiance Correction (일사 수광량 보정에 의한 산악지대 매시기온의 공간내삽)

  • 정유란;윤진일
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.4 no.2
    • /
    • pp.95-102
    • /
    • 2002
  • Spatial interpolation has become a common procedure in converting temperature forecasts and observations at irregular points for use in regional scale ecosystem modeling and the model based decision support systems for resource management. Neglection of terrain effects in most spatial interpolations for short term temperatures may cause erroneous results in mountainous regions, where the observation network hardly covers full features of the complicated terrain. A spatial interpolation model for daytime hourly temperature was formulated based on error analysis of unsampled site with respect to the site topography. The model has a solar irradiance correction scheme in addition to the common backbone of the lapse rate - corrected inverse distance weighting. The solar irradiance scheme calculates the direct, diffuse and reflected components of shortwave radiation over any surfaces based on the sun-slope geometry and compares the sum with that over a reference surface. The deviation from the reference radiation is used to calculate the temperature correction term by an empirical conversion formula between the solar energy and the air temperature on any sloped surfaces at an hourly time scale, which can be prepared seasonally for each land cover type. When this model was applied to a 14 km by 22 km mountainous region at a 10 m horizontal resolution, the estimated hourly temperature surfaces showed a better agreement with the observed distribution than those by a conventional method.

Investigation of Conserved Genes in Microorganism (미생물의 보존적 유전자 탐색)

  • Lee Dong-Geun;Lee Jae-Hwa;Lee Sang-Hyeon;Ha Bae-Jin;Shim Doo-Hee;Park Eun-Kyung;Kim Jin-Wook;Li Hua-Yue;Nam Chun-Suk;Kim Nam Young;Lee Eo-Jin;Back Jin-Wook;Ha Jong-Myung
    • Journal of Life Science
    • /
    • v.15 no.2 s.69
    • /
    • pp.261-266
    • /
    • 2005
  • To figure out conserved genes in 66 microbial species and measuring the degree of conservation, analyses based on COG (Clusters of Orthologous Groups of proteins) algorithm were applied. Sixty-six microbial genomes, including three eukaryotes, hold 63 conserved orthologs in common. The majority $(82.5\%)$ of the conserved genes was related to translation, meaning the importance of protein in living creatures. Ribosomal protein S12 (COG0048) and L14 (COG0093) were more conserved genes than others from the distance value analysis. Phylogenetically related microbes grouped in genome analysis by average and standard deviation of 63 conserved genes. The 63 conserved genes, found in this research, would be useful in basic research and applied ones such as antibiotic development.

Rotary Veneer Peeling of Some Softwoods and Its Veneer Drying (수종(數種)의 침엽수재(針葉樹材)의 로타리 단판(單板) 절삭(切削)과 건조(乾燥))

  • Jung, Hee-Suk;Lee, Nam-Ho;Yeo, Hwan-Myeong;Lee, June-Ho;Yoo, Tae-Kyung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.34-47
    • /
    • 1996
  • Veneers of two nominal thicknesses, 1.5 and 2.5mm, were rotary peeled from Japanese larch (Larix leptolepis). Dahurian larch (Larix gmelinei) and Radiata pine (Pinus radiata) bolts unheated and heated in the water vat temperature of $66^{\circ}C$ by rising a final temperature at 10cm core of $60^{\circ}C$ to remain core diameter of 11.4cm. 1.5 and 2.5mm thick veneer cut from the heated Japanese larch were significantly thinner than those of the unheated bolt and 2.5mm thick veneer cut from the heated Dahurian larch were significantly thicker than that of the unheated bolt. 1.5mm thick Dahurian larch veneer and 1.5 and 2.5mm thick Radiata pine veneers showed insignificant difference between the unheated and heated bolts, respectively. Check distance on the loose side of 1.5mm thick veneer cut from the heated Radiata pine was significantly wider than that of the unheated bolt. However check distances on the loose side of 1.5 and 2.5mm thick Japanese larch and Dahurian larch veneers and 2.5mm thick Radiata pine veneers showed insignificant difference between the unheated and heated bolts. Also the depth of check on the loose side of three species showed insignificantly difference between the unheated and heated bolts. Arithmatic mean deviation($R_a$) and maximum height($R_{max}$) of the profile on the loose side of dried veneer by preheating the bolt compared with unheated bolts were different among apecies and between veneer thickness. The preheating treatment slightly affected qualities of these thin veneers such as 1.5 and 2.5mm. The yield of 2.5mm thick veneer from the heated radiata pine was significantly higher than that of the unheated bolt. However the yield of 2.5mm thick veneer for other two species and 1.5mm thick veneer for three species showed insignificant difference between the unheated and heated bolts. The yield of 2.5mm thick veneer for three species were higher than those of 1.5mm thick veneer. The average yields of green veneer of Japanese larch. Dahurian larch and Radiata pine were 57.1, 55.1 and 54.0 percent, respectively. Variables such as initial MC. drying time and veneer thickness had strong effect for Japanese larch veneer, less effect for Radiata pine veneer and nuch less effect on final MC for Dahurian larch veneer in jet drying. Correlation between the current MC and the drying time of Dahurian larch with low variation of initial MC was higher than those of Japanese larch and Radiata pine veneer with high variation of initial MC in high temperature drying. Thickness shrinkages of 2.5mm thick veneer for Japanese larch and Radiata pine were higher than those of 1.5mm thick veneers, but shrinkages of Dahurian larch veneer were similar between two nominal veneer thicknesses.

  • PDF

Reproducibility Evaluation of Deep inspiration breath-hold(DIBH) technique by respiration data and heart position analysis during radiation therapy for Left Breast cancer patients (좌측 유방암 환자의 방사선치료 중 환자의 호흡과 심장 위치 분석을 통한 Deep inspiration breath-hold(DIBH) 기법의 재현성 평가)

  • Jo, Jae Young;Bae, Sun Myung;Yoon, In Ha;Lee, Ho Yeon;Kang, Tae Young;Baek, Geum Mun;Bae, Jae Beom
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.297-303
    • /
    • 2014
  • Purpose : The purpose of this study is reproducibility evaluation of deep inspiration breath-hold(DIBH) technique by respiration data and heart position analysis in radiation therapy for Left Breast cancer patients. Materials and Methods : Free breathing(FB) Computed Tomography(CT) images and DIBH CT images of three left breast cancer patients were used to evaluate the heart volume and dose during treatment planing system( Eclipse version 10.0, Varian, USA ). The signal of RPM (Real-time Position Management) Respiratory Gating System (version 1.7.5, Varian, USA) was used to evaluate respiration stability of DIBH during breast radiation therapy. The images for measurement of heart position were acquired by the Electronic portal imaging device(EPID) cine acquisition mode. The distance of heart at the three measuring points(A, B, C) on each image was measured by Offline Review (ARIA 10, Varian, USA). Results : Significant differences were found between the FB and DIBH plans for mean heart dose (6.82 vs. 1.91 Gy), heart $V_{30}$ (68.57 vs. $8.26cm^3$), $V_{20}$ (76.43 vs. $11.34cm^3$). The standard deviation of DIBH signal of each patient was ${\pm}0.07cm$, ${\pm}0.04cm$, ${\pm}0.13cm$, respectively. The Maximum and Minimum heart distance on EPID images were measured as 0.32 cm and 0.00 cm. Conclusion : Consequently, using the DIBH technique with radiation therapy for left breast cancer patients is very useful to establish the treatment plan and to reduce the heart dose. In addition, it is beneficial to using the Cine acquisition mode of EPID for the reproducibility evaluation of DIBH.

IN VITRO EVALUATION OF THE CONSISTENCY OF TWO ELECTRONIC APEX LOCATORS (2종 전자근관장측정기의 일관성에 관한 in vitro 연구)

  • Hwang, Gyu-Young;Roh, Byoung-Duck;Kim, Eui-Sung;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.1
    • /
    • pp.20-27
    • /
    • 2008
  • The purpose of this study was to evaluate the consistency of two electronic apex locators in vitro model. Materials consisted of fifty two extracted premolars and two electronic apex locators; Root ZX (J. Morita, Osaka, Japan) and E-Magic Finder Deluxe (S-Denti. Cheonan, Korea). After access preparation, the teeth were embedded in a saline-mixed alginate model. Canal lengths of each tooth were measured at "0.5" and "Apex" mark of the apex locators, respectively so that each tooth had two measurements from 0.5 and Apex points. The file was fixed at final measurement using a glass ionomer cement. The apical 4 mm from the apex was exposed to measure the distance from the file tip to the major apical foramen of each tooth. Average distances and standard deviations were used to evaluate the consistency. Results showed that all measurements of both Root ZX and E-Magic Finder located the major foramen the range of ${\pm}0.5\;mm$ level. Both apex locators showed better consistency at Apex mark than at 0.5 mark. The average distance of file tip-major foramen was - 0.18 mm at 0.5 mark and - 0.07 mm at Apex mark in Root ZX, - 0.25 mm at 0.5 mark and - 0.02 mm at Apex mark in E-Magic Finder. Standard deviation was 0.21 at 0.5 mark and 0.12 at Apex mark in Root ZX, 0.12 at 0.5 mark and 0.09 at Apex mark in E-Magic Finder.