• Title/Summary/Keyword: deviation of distance

Search Result 439, Processing Time 0.033 seconds

NASAL ASYMMETRY AFTER PRIMARY OPERATIONS IN PATIENTS WITH UNILATERAL CLEFT LIP (일차 토순 수술후의 코입부위의 심미적 평가 제1보 코의 비대칭성)

  • Min, Byong-Il
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.16 no.4
    • /
    • pp.390-395
    • /
    • 1994
  • The author evaluated the nasal asymmetry after primary operations in the patients with unilateral cleft lip using full face photographs. The results are as follows : 1. Nasal deviation angle is average 2.98+3.01 degree(ranged from 0 to 10 degree), significantly different from control group(p<0.05). 2. Nasal deviation angle is average 5.1% when inter-medial canthal distance is 100%, significantly different from control group(p<0.05). 3. Difference in nostril size between cleft and noncleft side is 2.1% when inter-medial canthal distance is 100%, significantly different from control group(p<0.05). 4. Nasal attractiveness analysis shows higher points in difference in nostril size, nasal deviation, nasal form in that order. 5. Nasal asymmetry after primary operations in the patients with unilateral cleft lip using full face photographs is related with Nasal deviation angle, Nasal deviation distance and Difference in nostril size between cleft and noncleft side.

  • PDF

Effects of inter-implant distance on the accuracy of intraoral scanner: An in vitro study

  • Thanasrisuebwong, Prakan;Kulchotirat, Tharathip;Anunmana, Chuchai
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.2
    • /
    • pp.107-116
    • /
    • 2021
  • PURPOSE. Several studies focused on the accuracy of intra-oral scanners in implant dentistry, but the data of inter-implant distances were not widely mentioned. Therefore, this study aimed to evaluate the effect of distance between two implants on the surface distortion of scanned models generated by intra-oral scanners. MATERIALS AND METHODS. Three models with the distances between two fixed scan bodies of 7, 14, and 21 mm were fabricated and scanned with a highly precise D900L dental laboratory scanner as reference models. Fifteen scans were performed with TRIOS3 and CEREC Omnicam intra-oral scanners. Trueness, precision, and angle deviation of the test models were analyzed (α=.05). RESULTS. There was a significant difference among inter-implant distances in both intraoral scanners (P<.001). The error of trueness and precision increased with the increasing inter-implant length, while the angle deviation did not show the same trend. A significant difference in the angle deviation was found among the inter-implant distance. The greatest angle deviation was reported in the 14-mm group of both scanners (P<.05). In contrast, the lowest angle deviation in the 21-mm group of the TR scanner and the 7-mm of the CR scanner was reported (P<.001). CONCLUSION. The inter-implant distance affected the accuracy of intra-oral scanner. The error of trueness and precision increased along with the increasing distance between two implants. However, the distortions were not clinically significant. Regarding angle deviation, the clinically significant angle deviation may be possible when using intra-oral scanners in the partially edentulous arch.

Estimation of Allowable Path-deviation Time in Free-space Optical Communication Links Using Various Aircraft Trajectories

  • Kim, Chul Han
    • Current Optics and Photonics
    • /
    • v.3 no.3
    • /
    • pp.210-214
    • /
    • 2019
  • The allowable path-deviation time of aircraft in a free-space optical communication system has been estimated from various trajectories, using different values of aircraft speeds and turn rates. We assumed the existence of a link between the aircraft and a ground base station. First, the transmitter beam's divergence angle was calculated through two different approaches, one based on a simple optical-link equation, and the other based on an attenuation coefficient. From the calculations, the discrepancy between the two approaches was negligible when the link distance was approximately 110 km, and was under 5% when the link distance ranged from 80 to 140 km. Subsequently, the allowable path-deviation time of the aircraft within the tracking-error tolerance of the system was estimated, using different aircraft speeds, turn rates, and link distances. The results indicated that the allowable path-deviation time was primarily determined by the aircraft's speed and turn rate. For example, the allowable path-deviation time was estimated to be ~3.5 s for an aircraft speed of 166.68 km/h, a turn rate of $90^{\circ}/min$, and a link distance of 100 km. Furthermore, for a constant aircraft speed and turn rate, the path-deviation time was observed to be almost unchanged when the link distance ranged from 80 to 140 km.

Ranging the Distance Between Wireless Sensor Nodes Using the Deviation Correction Method of Received Signal Strength (수신신호세기의 편차 보정법을 이용한 무선센서노드 간의 거리 추정)

  • Lee, Jin-Young;Kim, Jung-Gyu
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.7 no.2
    • /
    • pp.71-78
    • /
    • 2012
  • Based on the Zigbee-based wireless sensor network, I suggest the way to reduce errors between the short distance, improving the accuracy of the presumed distance by revising the deviation of RSSI(Received Signal Strength Indication) values is to estimate the distance using only the RF signal power without the additional hardware. In general, the graph measured by RSSI values shows the proximity values which are ideally reduced in proportion to the distance under the free outdoor space in which LOS(Line-Of-Sight) is guaranteed. However, if the result of the received RSSI values are each substituted to the formula, it can produce a larger margin of error and less accurate measurement since it is based upon the premise that this free space is not affected by reflected waves or obstacles caused by the ground and electronic jamming engendered by the environment. Therefore, the purpose of this study is to reduce the margin of errors between the distances and to measure the proximity values with the ideal type of graph by suggesting the way to revise the received RSSI values in the light of these reflected waves or obstacles and the electronic jamming. In conclusion, this study proves that errors are reduced by comparing the proposed deviation correction method to the revised RSSI value.

Study on Distance Measurement of Beacon Using Extended Kalman Filter (확장 칼만 필터를 이용한 비콘의 거리 측정에 관한 연구)

  • Jang, Gyuho
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.18 no.3
    • /
    • pp.1-7
    • /
    • 2022
  • In this study, inaccurate RSSI values of beacons are corrected using extended Kalman filter. For the experiment, the beacon was manufactured using Arduino Uno board and HM-10 Bluetooth module. RSSI values according to the distance between beacon and the viewer were measured at intervals of 1m, 1.5m, 2m, 2.5m, 3m, 3.5m, 4m, 4.5m, and 5m. To remove the irregular signal pattern of the beacon, the extended Kalman filter was applied to obtain the average and standard deviation of the actual distance and the measured distance, and it was confirmed that more than 76.6% of the irregular signal pattern was removed after using the extended Kalman filter.In addition, through the smartphone app, it was confirmed that the distance accuracy between the beacon and the measurer was less than the actual distance and the measured distance within 2m, and the standard deviation was small.

An Accuracy Analysis of the 3D Automatic Body Measuring Machine (3차원 자동체형계측기 정밀도 검사)

  • Jeon, Soo-Hyung;Kwon, Suk-Dong;Park, Se-Jung;Kim, Jung-Yang;Song, Jung-Hoon;Kim, Hyun-Jin;Kim, Jong-Won
    • Journal of Sasang Constitutional Medicine
    • /
    • v.20 no.1
    • /
    • pp.42-47
    • /
    • 2008
  • 1. Objectives The Body Shape and Feature is one of the important standard for classification of Sasang Constitutions. In order to evaluate one's Body Shape and Feature objectively we have been developing the Body Measuring Machine. Now we develop the 3D Automatic Body Measuring Machine(3D-ABMM). So we make an analysis of the 3D-ABMM's Accuracy. 2. Methods By using the 3D-ABMM and Vivid 9i(3D laser scanner, Konica Minolta) we have a surface scan of the three objects which are the upper body of the female and male Manikin and a male model. We overlap each scan data using the RapidForm2006 (3D scan data solution, INUS Technology) and calculate the average distance and standard deviation between the same point of each scan data. 3. Results and Conclusions In the female Manikin, the average distance is 0.84mm and the standard deviation is 1.16mm and the maximum distance is 10.68mm. In the male Manikin, the average distance is 1.12mm and the standard deviation is 1.19mm and the maximum distance is 12.00mm. In the male model, the average distance is 3.26mm and the standard deviation is 2.59mm and the maximum distance is 12.75mm. From the results, 3D-ABMM has good accuracy for scanning body and will be a usable hardware of the 3D Automatic Body Analysis Machine.

  • PDF

Analysis of Distance Measurement Accuracy in Aerial and Satellite Image Photogrammetry (항공사진측량과 위성영상측량에서 거리측정 정확도 연구)

  • Kim, Hyung-Moo;Tcha, Dek-Kie;Nam, Guon-Mo;Yang, Chul-Soo
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2010.04a
    • /
    • pp.253-255
    • /
    • 2010
  • Needs to study on distance measurement accuracy in aerial and satellite photogrammetry are rapidly increased. However, conventional studies show some confused definitions between measurement accuracy and measurement precision as well as standard deviation(STDEV) and root mean square error(RMSE or RMSD). So, Finite definitions of measurement accuracy and measurement precision as well as STDEV and RMSD are addressed in this paper. Experiment result show using correct definitions improve the distance measurement accuracy in aerial and satellite photogrammetry rapidly, but not the distance measurement accuracy in aerial and satellite photogrammetry.

  • PDF

A Case of Seismic Crosshole Tomography Applying Borehole Deviation Correction (시추공 편차 보정을 적용한 탄성파시추공토모그래피 사례)

  • Kang, Jong-Seok;Cha, Young-Ho;Jo, Churl-Hyun;Choi, Jong-Ho;Shim, Weon-Hum;Park, Yong-Sung
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.221-224
    • /
    • 2006
  • seismic crosshole tomography works applying borehole deviation correction were performed at a test site to detect a small cavity. Two correction methods were applied. The one is the constant distance correction which adds constant distance to surface borehole distance and the other is the constant angle correction which considers an angle between surface borehole location and bottom borehole location. After applying the corrections, the distortions of the image diminished while its resolution improved. Though the constant angle correction is the most appropriate correction method, the constant distance correction can delineate the small cavity sufficiently.

  • PDF

Computed Tomographic Evaluation of the Nasal Septum Deviation in Clinically Normal Dogs (정상 개에서 컴퓨터단층촬영을 이용한 비중격 변위 평가)

  • Lee, Ki-Ja;Lee, In;Lee, Hee-Chun;Han, Woo-Sok;Choi, Ho-Jung;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.28 no.5
    • /
    • pp.506-509
    • /
    • 2011
  • This study was performed to determine a comprehensive anatomic variation and deviation of the nasal septum in clinically normal dogs by use of computed tomography (CT). The nasal septum was evaluated in 36 shihtzu dogs and 16 beagle dogs. A degree of a septal deviation was evaluated by measuring a maximum angle and a distance of the septal deviation. The angle and distance of the septal deviation were significantly higher in shih-tzu dogs than in beagle dogs. There was no significant relationship between body weight and age and all measurements (angle and distance) in both breed dogs. Results of this study suggest that nasal septum deviation and its defect are observed on CT images of clinically normal dogs, especially in shih-tzu dogs.

Construction of Large Library of Protein Fragments Using Inter Alpha-carbon Distance and Binet-Cauchy Distance (내부 알파탄소간 거리와 비네-코시 거리를 사용한 대규모 단백질 조각 라이브러리 구성)

  • Chi, Sang-mun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.12
    • /
    • pp.3011-3016
    • /
    • 2015
  • Representing protein three-dimensional structure by concatenating a sequence of protein fragments gives an efficient application in analysis, modeling, search, and prediction of protein structures. This paper investigated the effective combination of distance measures, which can exploit large protein structure database, in order to construct a protein fragment library representing native protein structures accurately. Clustering method was used to construct a protein fragment library. Initial clustering stage used inter alpha-carbon distance having low time complexity, and cluster extension stage used the combination of inter alpha-carbon distance, Binet-Cauchy distance, and root mean square deviation. Protein fragment library was constructed by leveraging large protein structure database using the proposed combination of distance measures. This library gives low root mean square deviation in the experiments representing protein structures with protein fragments.