• Title/Summary/Keyword: deviation analysis

Search Result 3,574, Processing Time 0.033 seconds

The Characteristic Analysis of Content Areas and Behavioral Areas Based on the Deviation of NAEA Achievement Level-Based Correct-Answer Rate (국가수준 학업성취도 평가의 성취수준별 정답률 편차에 따른 내용 영역과 행동 영역 특성 분석)

  • Huh, Nan;Yang, Seong Hyun
    • Communications of Mathematical Education
    • /
    • v.32 no.3
    • /
    • pp.435-453
    • /
    • 2018
  • The results analysis of National Assessment of Educational Achievement(NAEA) can provide various implications for teaching and learning in the school field. In this study we analyzed the deviation of NAEA achievement level-based correct-answer rate and the distribution of the responses percentages for three years from 2015 to 2017 focused on multiple-choice items. First we calculated the deviation of correct-answer rate between advanced level and proficient level and between proficient level and basic level, and then we selected the items whose deviation of correct-answer rate is more than the third quartile. We explored what the content areas, behavior areas and achievement standards of each item are and what the achievement standards and characteristics of these questions are. Based on the results of the analysis, we intended to derive implications for appropriate teaching-learning methods at each achievement-level.

Obstructive Sleep Apnea Analysis Based on Heart Rate Variability (폐쇄성 수면 무호흡 검출을 위한 심박동변이율 분석)

  • Ye, Soo-Young;Kim, Jung-Guk;Kim, Dong-Hyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.7
    • /
    • pp.605-608
    • /
    • 2011
  • In this study, OSA (the obstructive sleep apnea) periods were detected in patients with OSA during sleep because of the treatment was different according to the frequency and symptoms of obstructive sleep apnea. ANS (autonomic nervous activity) was changed by obstructive sleep apnea periods so we intended to detect the periods to care the obstructive sleep apnea patients. RR intervals, SDNN (standard deviation of normal to normal) and RMSSD (root mean square standard deviation) were calculated in time domain analysis and LF (low frequency), HF (high frequency), NHF (normalized high frequency), NLF (normalized low frequency) were calculated in frequency domain analysis of HRV (heart rate variability) with obstructive sleep apnea patients. In this paper, SDNN (standard deviation of normal to normal) of time domain analysis were decreased in the obstructive sleep apnea periods. And NLF and LF/HF ratio were increased and NHF (normalized high frequency) was decreased in the frequency domain analysis. The parameters can be used to treat obstructive sleep apnea patients by detecting the obstructive sleep apnea periods such as CPAP (continuous positive airway pressure).

OPTIMIZATION OF THE PARAMETERS OF FEEDWATER CONTROL SYSTEM FOR OPR1000 NUCLEAR POWER PLANTS

  • Kim, Ung-Soo;Song, In-Ho;Sohn, Jong-Joo;Kim, Eun-Kee
    • Nuclear Engineering and Technology
    • /
    • v.42 no.4
    • /
    • pp.460-467
    • /
    • 2010
  • In this study, the parameters of the feedwater control system (FWCS) of the OPR1000 type nuclear power plant (NPP) are optimized by response surface methodology (RSM) in order to acquire better level control performance from the FWCS. The objective of the optimization is to minimize the steam generator (SG) water level deviation from the reference level during transients. The objective functions for this optimization are relationships between the SG level deviation and the parameters of the FWCS. However, in this case of FWCS parameter optimization, the objective functions are not available in the form of analytic equations and the responses (the SG level at plant transients) to inputs (FWCS parameters) can be evaluated by computer simulations only. Classical optimization methods cannot be used because the objective function value cannot be calculated directely. Therefore, the simulation optimization methodology is used and the RSM is adopted as the simulation optimization algorithm. Objective functions are evaluated with several typical transients in NPPs using a system simulation computer code that has been utilized for the system performance analysis of actual NPPs. The results show that the optimized parameters have better SG level control performance. The degree of the SG level deviation from the reference level during transients is minimized and consequently the control performance of the FWCS is remarkably improved.

Three-dimensional computed tomography evaluation of craniofacial characteristics according to lateral deviation of chin

  • CHOI, Hyo-Won;KIM, Bola;KIM, Jae-Young;HUH, Jong-Ki;PARK, Kwang-Ho
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.57.1-57.8
    • /
    • 2019
  • Background: The relationship between the lateral deviation of chin and the upper and middle facial third asymmetry is still controversial. The purpose of this study is to evaluate the correlation of upper and middle facial third asymmetry with lateral deviation of chin using 3-dimensional computed tomography. The study was conducted on patients who underwent orthognathic surgery from January 2016 to August 2017. A total of 40 patients were included in this retrospective study. A spiral scanner was used to obtain the 3-dimensional computed tomography scans. The landmarks were assigned on the reconstructed 3-dimensional images, and their locations were verified on the axial, midsagittal, and coronal slices. The Pearson correlation analysis was performed to evaluate the correlation between chin deviation and difference between the measurements of distances in paired craniofacial structures. Statistical analysis was performed at a significance level of 5%. Results: In mandible, the degree of chin deviation was correlated with the mandibular length and mandibular body length. Mandibular length and mandibular body length are shorter on the deviated-chin side compared to that on the non-deviated side (mandibular length, r = -0.897, p value < 0.001; mandibular body length, r = -0.318, p value = 0.045). In the upper and middle facial thirds, the degree of chin deviation was correlated with the vertical asymmetry of the glenoid fossa and zygonion. Glenoid fossa and zygonion are superior on the deviated-chin side than on the non-deviated side (glenoid fossa, r = 0.317, p value = 0.046; zygonion, r = 0.357, p value = 0.024). Conclusion: Lateral deviation of chin is correlated with upper and middle facial third asymmetry as well as lower facial third asymmetry. As a result, treatment planning in patients with chin deviation should involve a careful evaluation of the asymmetry of the upper and middle facial thirds to ensure complete patient satisfaction.

Analysis on the Effect of Material and Forming Conditions on the Cup Earing by Taguchi Method (실험계획법을 이용한 컵 귀발생의 영향인자 해석)

  • 정기조
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1999.03b
    • /
    • pp.30.1-33
    • /
    • 1999
  • Finite element simulation with experimental analysis of Taguchi's orthogonal array was carried out to know the effects of material and forming parameters on the cup earing and skewness. It was revealed that the planar anisotropy was the most influencing factor in the cup ear formation whereas blank holding force and material properties such as strength and thickness deviation at the coil edge had a relatively high effect on the cup skewness.

  • PDF

Analysis of Kinematics and Tooth Profile in Harmonic Drive (주속식 감속기의 운동학 및 치형해석)

  • 전완주
    • Tribology and Lubricants
    • /
    • v.4 no.2
    • /
    • pp.60-67
    • /
    • 1988
  • Conventional theory of gear mechanism can't be applied to analyze the harmonic drive due to specific movement of the teeth. This paper deals with an analysis of kinematics and geometry of the tooth engagement of a harmonic drive comprising circular spline, flexspline and wave generator. A theoretical new tooth profile of the flexspline in meshing internal rigid gear with involute profile is obtained. Characteristics of harmonic drive reducer are shown according to parameters such as deviation coefficient, deviation distance, addendum modification coefficient. As an example, the design of harmonic drive with 1:80 reduction ratio is presented.

A Study on Verification of Shoe Last Grading System Based on Foot Measuring Data (발계측 자료에 기초한 신골 할출 시스템의 검증에 관한 연구)

  • Park, Hae-Soo
    • Journal of the Ergonomics Society of Korea
    • /
    • v.26 no.1
    • /
    • pp.71-77
    • /
    • 2007
  • Shoe's size and shape are determined by the last that takes shape of foot because last is the mold of shoe in development and manufacturing process. Then adaptation between foot and shoe is dependent on the last. In mass shoe production, model size is developed in the first place, other sized lasts are made through the grading process based on model size. The most important factor in grading system is grading deviation that must be same amount induced from foot measuring database. At present, most of the last manufacturing companies in korea using 260mm as a standard foot model size. When length grading deviation is 5mm, the ball girth grading deviation is 3.7mm and the ball width grading deviation is 1.2mm. I verified existing grading system by comparing grading results with foot measuring data. Also, I proposed reasonable grading deviation and application method of grading system. From the analysis of foot measuring database, reasonable grading deviations are 1.22mm in ball width and 0.84mm in ankle height in case of length grading deviation is 5mm. I confirmed that the current grading system is very accurate. When we grade last from 230mm to 290mm by current grading system based on model size 260mm, there is grading error over 1mm in the front outside area of foot. This error level of 1mm is no problem in normal walking shoe's last, but it induces adaptation problems in sports and special purposed shoe's last. Therefore using of three standard model size is recommended in grading men's last for reducing grading deviation error under the level of 1mm. It is specifically described as 235mm in 225-245mm, 260mm in 250-270mm, 285mm in 275-295mm. According to the above recommended grading system, it is enough to measure only three foot sizes in case of foot measuring project for men's last development.

Three-dimensional analysis of the outcome of different scanning strategies in virtual interocclusal registration

  • Jiansong, Mei;Liya, Ma;Jiarui, Chao;Fei, Liu;Jiefei, Shen
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.6
    • /
    • pp.369-378
    • /
    • 2022
  • PURPOSE. The purpose of this in vitro study was to assess whether scanning strategies of virtual interocclusal record (VIR) affect the accuracy of VIR during intraoral scanning. MATERIALS AND METHODS. Five pairs of reference cubes were added to the digital upper and lower dentitions of a volunteer, which were printed into resin casts. Subsequently, the resin casts were articulated in the maximal intercuspal position in a mechanical articulator and scanned with an industrial computed tomography system, of which the VIR was served as a reference VIR. The investigated VIR of the upper and lower jaws of the resin master cast were recorded with an intraoral scanner according to 9 designed scanning strategies. Then, the deviation between the investigated VIRs and reference VIR were analyzed, which were measured by the deviation of the distances of six selected reference points on the upper reference cubes in each digital cast to the XY-plane between the investigated VIRs and reference VIR. RESULTS. For the deviation in the right posterior dentitions, RP group (only scanning of right posterior dentitions) showed the smallest deviation. Besides, BP group (scanning of bilateral posterior dentitions) showed the smallest deviation in the left posterior dentitions. Moreover, LP group (scanning of left posterior dentitions) showed the smallest deviation in the anterior dentitions. For the deviation of full dental arches, BP group showed the smallest deviation. CONCLUSION. Different scanning strategies of VIR can influence the accuracy of alignment of virtual dental casts. Appropriate scanning strategies of VIR should be selected for different regions of interest and edentulous situations.

An $\overline{X}$-Control Chart Based on the Gini′s Mean Difference (지니(Gini)의 평균차이에 기초한 $\overline{X}$-관리도)

  • 남호수;강중철
    • Journal of Korean Society for Quality Management
    • /
    • v.29 no.3
    • /
    • pp.79-85
    • /
    • 2001
  • Estimation of the process deviation is an important problem in statistical process control, especially in the control chart, process capability analysis or measurement system analysis. In this paper we suggest the use of the Gini's mean difference for the estimation of the process deviation when we design the control limits in construction of the control charts. The efficiency of the Gini's mean difference was well explained in Nam, Lee and Jung(2000). In this paper we propose an $\overline{X}$ control chart which use the control limits based on the Gini's mean difference. In various classes of distributions, the proposed control chart shows food performance.

  • PDF

On the Estimation of the Process Deviation Based on the Gini's Mean Difference (지니(Gini)의 평균차이를 이용한 공정산포 추정)

  • 남호수;이병근;정현석
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.23 no.58
    • /
    • pp.113-118
    • /
    • 2000
  • Estimation of the process deviation is an important problem in statistical process control, especially in the control chart, process capability analysis or measurement system analysis. In this paper we suggest the use of the Gini's mean difference for the estimation of the c, the measure of the process deviation through a lots of simulations in various types of distributions. The Gini's mean difference uses the differences of all possible pairs of data. This point will improve the efficiency of estimation. In various classes of distributions, the Gini's mean difference shows good performance, in sense of bias of estimates or mean squared errors.

  • PDF