• Title/Summary/Keyword: development of sensitivity

Search Result 2,375, Processing Time 0.031 seconds

Development of a Method for Analyzing the Nicotine Content in Synthetic Flavoring Substances as Unauthorized E-cigarette Liquid by Using HPLC (전자담배 액상 충진제와 유사한 합성착향료 중 니코틴의 HPLC 분석법 개발)

  • Kim, Jae-Young;Lee, Sang-Mok;Chang, Moon-Ik;Cho, Yoon-Jae;Lee, Han-Jin;Chae, Young-Sik;Rhee, Gyu-Sik
    • Korean Journal of Food Science and Technology
    • /
    • v.45 no.6
    • /
    • pp.693-699
    • /
    • 2013
  • A simple, sensitive, and specific method for quantifying the nicotine content of synthetic favoring substances (SFS) was developed using high performance liquid chromatography (HPLC) with a photo-diode array detector (PDA). Nicotine was extracted from SFS samples by using an acid-base liquid-liquid extraction method with dichloromethane and distilled water. The nicotine content was quantified by HPLC/PDA (261.9 nm) with a $C_{18}$ column under a gradient of 10% acetonitrile with 20 mM ammonium formate (ammonia solution adjusted to pH 8.7) to 100% acetonitrile. The calibration curve, analyzed from concentration standards between 0.1 to 2 mg/L, presented linearity with a correlation coefficient ($r^2$)>0.9999. The limit of quantitation (LOQ) of nicotine in SFS was 0.4 mg/kg, and the average recoveries ranged from 76.4% to 96.3%. The repeatability of measurements, expressed as the coefficient of variation (CV%), ranged from 1.74 to 5.12%. This newly developed method for nicotine quantification in SFS can be considered an analytical method with an acceptable level of sensitivity and repeatability.

Real-time Nutrient Monitoring of Hydroponic Solutions Using an Ion-selective Electrode-based Embedded System (ISE 기반의 임베디드 시스템을 이용한 실시간 수경재배 양액 모니터링)

  • Han, Hee-Jo;Kim, Hak-Jin;Jung, Dae-Hyun;Cho, Woo-Jae;Cho, Yeong-Yeol;Lee, Gong-In
    • Journal of Bio-Environment Control
    • /
    • v.29 no.2
    • /
    • pp.141-152
    • /
    • 2020
  • The rapid on-site measurement of hydroponic nutrients allows for the more efficient use of crop fertilizers. This paper reports on the development of an embedded on-site system consisting of multiple ion-selective electrodes (ISEs) for the real-time measurement of the concentrations of macronutrients in hydroponic solutions. The system included a combination of PVC ISEs for the detection of NO3, K, and Ca ions, a cobalt-electrode for the detection of H2PO4, a double-junction reference electrode, a solution container, and a sampling system consisting of pumps and valves. An Arduino Due board was used to collect data and to control the volume of the sample. Prior to the measurement of each sample, a two-point normalization method was employed to adjust the sensitivity followed by an offset to minimize potential drift that might occur during continuous measurement. The predictive capabilities of the NO3 and K ISEs based on PVC membranes were satisfactory, producing results that were in close agreement with the results of standard analyzers (R2 = 0.99). Though the Ca ISE fabricated with Ca ionophore II underestimated the Ca concentration by an average of 55%, the strong linear relationship (R2 > 0.84) makes it possible for the embedded system to be used in hydroponic NO3, K, and Ca sensing. The cobalt-rod-based phosphate electrodes exhibited a relatively high error of 24.7±9.26% in the phosphate concentration range of 45 to 155 mg/L compared to standard methods due to inconsistent signal readings between replicates, illustrating the need for further research on the signal conditioning of cobalt electrodes to improve their predictive ability in hydroponic P sensing.

Effects of Elevated Air Temperature on Yield and Yield Components of Rice (온도 상승 조건이 벼의 수량 및 수량구성요소에 미치는 영향)

  • Lee, Kyu-Jong;Nguyen, Duc-Nhuan;Choi, Doug-Hwan;Ban, Ho-Young;Lee, Byun-Woo
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.17 no.2
    • /
    • pp.156-164
    • /
    • 2015
  • High temperature stress would affect rice production in the future as heat wave is expected to occur frequently under climate change conditions. The objective of this study was to obtain rudimentary information to assess the impact of heat stress on rice yield and its yield component in Korea. Two rice cultivars "Hwaseongbyeo" (Japonica) and "Dasanbyeo" (Tongil-type) were grown at different nitrogen fertilization levels in two seasons. These cultivars were grown in 1/5000a Wagner pot placed within four plastic houses where temperature was controlled at ambient, ambient$+1.5^{\circ}C$, ambient$+3^{\circ}C$ and ambient$+5^{\circ}C$ throughout the rice growing season in Suwon ($37^{\circ}16^{\prime}N$, $128^{\circ}59^{\prime}E$), Korea. The degree of temperature change affected grain yield whereas the level of nitrogen had little impact on grain yield. The number of panicle per pot and spikelet per panicle were not significantly different among temperature treatments in both cultivars tested. In contrast, 1000-grain weight and ripened grain ratio were decreased significantly under the treatments raising the air temperature to the level of $5.0^{\circ}C$ and $1.5^{\circ}C$ above the ambient air temperature in Dasanbyeo and Hwaseongbyeo, respectively. Reduction of 1000-grain weight and ripened grain ratio under the temperature treatments of $3.0^{\circ}C$ and $5.0^{\circ}C$ above the ambient air temperature resulted in significantly less grain yield for Dasanbyeo and Hwaseongbyeo, respectively. The greater sensitivity of grain yield to temperature increase in Dasanbyeo was attributable to the sharp decrease of 1000-grain weight and ripened grain ratio with the temperature rise above $23^{\circ}C$ during ripening period. On the other hand, Hwaseongbyeo had little variation of them in the temperature range of $23-27^{\circ}C$. These results suggested that grain yield would decrease under future climate conditions due to grain weight decreased by shorter grain filling period as well as the ripened grain ratio reduced by spikelet sterility and early abortion of rice kernel development. Thus, it would be essential to use cultivars tolerant to heat stress for climate change adaptation, which merits further studies for developing varieties that have traits to avoid spikelet sterility and early abortion of rice kernel, e.g., early morning flowering, under heat wave.

The Design and Fabrication of Conversion Layer for Application of Direct-Detection Type Flat Panel Detector (직접 검출형 평판 검출기 적용을 위한 변환층 설계 및 제작)

  • Noh, Si-Cheol;Kang, Sang-Sik;Jung, Bong-Jae;Choi, Il-Hong;Cho, Chang-Hoon;Heo, Ye-Ji;Yoon, Ju-Seon;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.1
    • /
    • pp.73-77
    • /
    • 2012
  • Recently, Interest to the photoconductor, which is used to flat form X-ray detector such as a-Se, $HgI_2$, PbO, CdTe, $PbI_2$ etc. is increasing. In this study, the film layer by using the photoconductive material with particle sedimentation was fabricated and evaluated. The quantization efficiency of the continuous X-ray with the 70 kVp energy bandwidth was analyzed by using the Monte Carlo simulation. With the results, the thickness of film with 64 % quantization efficiency was 180 ${\mu}m$ which is similar to the efficiency of 500 ${\mu}m$ a-Se film. And $HIg_2$ film has the high quantization efficiency of 74 % on 240 ${\mu}m$ thickness. The electrical characteristics of the 239 ${\mu}m$ $Hgl_2$ films produced by particle sedimentation were shown as very low dark current(under 10 $pA/mm^2$), and high sensitivity(19.8 mC/mR-sec) with 1 $V/{\mu}m$ input voltage. The SNR, which is influence to the contrast of X-ray image, was shown highly as 3,125 in low driving voltage on 0.8 $V/{\mu}m$. With the results of this study, the development of the low-cost, high-performance image detector with film could be possible by replacing the film produced by particle sedimentation instead to a-Se detector.

Development of Prevotella nigrescens ATCC $33563^T$-Specific PCR Primers (Prevotella nigrescens ATCC $33563^T$ 균주-특이 중합효소연쇄반응 프라이머 개발)

  • Song, Soo-Keun;Yoo, So-Young;Kim, Mi-Kwang;Kim, Hwa-Sook;Lim, Sun-A;Kim, Do-Kyung;Park, Jae-Yoon;Kook, Joong-Ki
    • Korean Journal of Microbiology
    • /
    • v.44 no.3
    • /
    • pp.212-220
    • /
    • 2008
  • A Pn10 DNA probe was introduced as a Prevotella nigrescens ATCC $33563^T$-specific DNA probe. In that study, the specificity of the Pn10 was tested with only type or reference strains of 5 oral bacterial species. The purpose of this study is to evaluate the specificity of the Pn10 using the wild type strains of P. nigrescens and is to develop the P. nigrescens ATCC $33563^T$-specific PCR primers based on the nucleotide sequence of the Pn10. The specificity of the Pn10 DNA probe was determined by Southern blot analysis. The nucleotide sequence of Pn10 DNA probes was determined by chain termination method. The PCR primers were designed based on the nucleotide sequence of cloned DNA fragment. The data showed that Pn10 DNA probe were hybridized with the genomic DNAs from P. nigrescens ATCC $33563^T$ and KB6. The Pn10 homologous region, KB6-Pn10, of P. nigrescens KB6 was cloned by PCR and sequenced. The Pn10 and KB6-Pn10 DNA fragments were consisted of 1,875 bp and 1,873 bp, respectively. The percent identity of the two was 98.8% and the divergence of them was 0.6%. The two primer sets (Pn10-F-AC/ Pn10-R-AC and Pn10-F-A/ Pn10-R-A), designed base on the nucleotide sequences of Pn10 DNA probe, were specific to the P. nigrescens ATCC $33563^T$. The two PCR primer sets could detect as little as 4 pg of genomic DNA of P. nigrescens ATCC $33563^T$. These results indicate that the two PCR primer sets have proven useful for the identification of P. nigrescens ATCC $33563^T$, especially with regard to the maintenance of the strain.

Development of Analytical Method for Ergot Alkaloids in Foods Using Liquid Chromatoraphy-Tandem Mass Spectrometry (LC-MS/MS를 이용한 식품 중 맥각 알칼로이드 시험법 개발)

  • Chun, So Young;Chong, Euna;Lee, Bomnae;Kwon, Jin-Wook;Park, Hye Young;Kim, Sheenhee;Gang, Giljin
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.2
    • /
    • pp.158-169
    • /
    • 2019
  • Ergot alkaloids are mycotoxin produced by fungi of the Claviceps genus, mainly by Claviceps purpurea in EU. Recently obtained informations indicates necessity for control the ergot in imported grains. Recent occurrence data of ergot alkaloids from EU countries indicate the necessities of management and control these toxins from the imported grains like rye, wheat, oat etc. The aim of this study is to optimize the liquid chromatography-tandem mass spectrometry method for determination of ergot alkaloids (ergometrine, ergosine, ergotamine, ergocornine, ergocryptine, ergocristine and their epimers (-inines) from grain and grain-based food. The test method was optimized by extracting the sample with acetonitrile containing 2 mM ammonium carbonate, purification with Mycosep cartridge, and instrumental analysis by LC-MS/MS using Syncronis C18 column. The standard calibration curves showed linearity with correlation coefficents; $R^2$ >0.99. Mean recoveries ranged from 72.0 to 111.3% at three different fortified levels (20, 50, and $100{\mu}g/kg$). The correlation coefficient expressed as precision was within the range of 1.9-12.9%. The limit or quantifications (LOQ) ranged from 0.012 to $0.058{\mu}g/kg$. The developed analytical method met the criteria of AOAC Int. and CAC validation parameters like accuracy and sensitivity. As a result, it was confirmed that the test method developed in this study is suitable for the simultaneous analysis of six species of ergot alkaloid from grains and grain products.

Development of a Small Gamma Camera Using NaI(T1)-Position Sensitive Photomultiplier Tube for Breast Imaging (NaI (T1) 섬광결정과 위치민감형 광전자증배관을 이용한 유방암 진단용 소형 감마카메라 개발)

  • Kim, Jong-Ho;Choi, Yong;Kwon, Hong-Seong;Kim, Hee-Joung;Kim, Sang-Eun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Moon-Hae;Joo, Koan-Sik;Kim, Byuug-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.365-373
    • /
    • 1998
  • Purpose: The conventional gamma camera is not ideal for scintimammography because of its large detector size (${\sim}500mm$ in width) causing high cost and low image quality. We are developing a small gamma camera dedicated for breast imaging. Materials and Methods: The small gamma camera system consists of a NaI (T1) crystal ($60 mm{\times}60 mm{\times}6 mm$) coupled with a Hamamatsu R3941 Position Sensitive Photomultiplier Tube (PSPMT), a resister chain circuit, preamplifiers, nuclear instrument modules, an analog to digital converter and a personal computer for control and display. The PSPMT was read out using a standard resistive charge division which multiplexes the 34 cross wire anode channels into 4 signals ($X^+,\;X^-,\;Y^+,\;Y^-$). Those signals were individually amplified by four preamplifiers and then, shaped and amplified by amplifiers. The signals were discriminated ana digitized via triggering signal and used to localize the position of an event by applying the Anger logic. Results: The intrinsic sensitivity of the system was approximately 8,000 counts/sec/${\mu}Ci$. High quality flood and hole mask images were obtained. Breast phantom containing $2{\sim}7 mm$ diameter spheres was successfully imaged with a parallel hole collimator The image displayed accurate size and activity distribution over the imaging field of view Conclusion: We have succesfully developed a small gamma camera using NaI(T1)-PSPMT and nuclear Instrument modules. The small gamma camera developed in this study might improve the diagnostic accuracy of scintimammography by optimally imaging the breast.

  • PDF

Development and Evaluation of Silicon Passive Layer Dosimeter Based Lead-Monoxide for Measuring Skin Dose (피부선량 측정을 위한 Lead-Monoxide 기반의 Silicon Passive layer PbO 선량계 개발 및 평가)

  • Yang, Seung-Woo;Han, Moo-Jae;Jung, Jae-Hoon;Bae, Sang-Il;Moon, Young-Min;Park, Sung-Kwang;Kim, Jin-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.781-788
    • /
    • 2021
  • Due to the high sensitivity to radiation, excessive exposure needs to be prevented by accurately measuring the dose irradiated to the skin during radiation therapy. Although clinical trials use dosimeters such as film, OSLD, TLD, glass dosimeter, etc. to measure skin dose, these dosimeters have difficulty in accurate dosimetry on skin curves. In this study, to solve these problems, we developed a skin dosimeter that can be attached according to human flexion and evaluated its response characteristics. For the manufacture of the dosimeter, lead oxide (PbO) with high atomic number (ZPb: 82, ZO: 8) and density (9.53 g/cm3) and silicon binders that can bend according to human flexion were used. In the case of a dosimeter made of PbO material, the performance degradation has been prevented by using parylene and others due to the presence of degradation due to oxidation, but the previously used parylene is affected by bending, so a new form of passive layer was produced and applied to the skin dosimeter. The characteristic evaluation of the skin dosimeter was evaluated by analyzing SEM, reproducibility, and linearity. Through SEM analysis, bending was evaluated, reproducibility and linearity at 6 MeV energy were evaluated, and applicability was assessed with a skin dosimeter. As a result of observing the dosimeter surface through SEM analysis, the parylene passive layer PbO dosimeter with the positive layer raised to the parylene produced cracks on the surface when bent. On the other hand, no crack was observed in the silicon passive layer PbO dosimeter, which was raised to silicon passive layer. In the reproducibility measurement results, the RSD of the silicon passive layer PbO dosimeter was 1.47% which satisfied the evaluation criteria RSD 1.5% and the linearity evaluation results showed the R2 value of 0.9990, which satisfied the evaluation criteria R2 9990. The silicon passive layer PbO dosimeter was evaluated to be applicable to skin dosimeters by demonstrating high signal stability, precision, and accuracy in reproducibility and linearity, without cracking due to bending.

Diagnostic Availability of Estrogen Receptor Alpha mRNA on Cervical Cancer Tissue (자궁경부암 조직에서 에스트로겐 수용체 알파 mRNA의 진단적 유용성)

  • Kim, Geehyuk;Yu, Kwangmin;Kim, Jungho;Kim, Seoyong;Park, Sunyoung;Ahn, Sungwoo;Lee, Ji-Young;Kim, Sunghyun;Park, Ho-Hyun;Lee, Dongsup
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.50 no.4
    • /
    • pp.449-456
    • /
    • 2018
  • Cervical cancer is the fourth most frequently diagnosed cancer in women worldwide. In lower Human Development Index countries, it has the second highest incidence and mortality among cancer in women. Therefore, better diagnosis and treatment systems are needed. Among them, estrogen receptor alpha ($ER-{\alpha}$) mRNA expression has been analyzed with RT-qPCR since several studies reported that $ER-{\alpha}$ is necessary in the maturation of the uterus and is related to cervical cancer. In this study, $ER-{\alpha}$ quantitative analysis was performed on various lesions and normal tissue samples. Based on the receiver operating characteristic (ROC) curve, its sensitivity and specificity were 85% and 75%, respectively, showing higher or similar results to those of conventional HPV tests. In addition, its expression level was analyzed with clinical information. With regression analysis, the R square value between the $ER-{\alpha}$ mRNA expression level and menopause status was 0.5041, indicating a strong correlation. This study was performed as part of a pilot study and suggests that $ER-{\alpha}$ is related to carcinogenesis. Future studies will examine other hormones and menopausal factors with a larger sample size.

A Study on Moltmann's Creationism and the Ecological Integrity of Christian Education (몰트만의 창조론과 기독교교육의 생태학적 통전성 고찰)

  • Lee, Hyangsoon
    • Journal of Christian Education in Korea
    • /
    • v.70
    • /
    • pp.107-140
    • /
    • 2022
  • This study is a review of the role of Christian education in the face of ecological crisis and the task of its recovery from the perspective of Moltmann's creation theory. Mankind has achieved epoch-making industrial development through several industrial revolutions. However, as a result, the ecosystem has suffered severe physical aches and has reached the point of revealing anomalies. In the face of such destruction and suffering of the ecosystem, Christian education needs to approach the ecological sensitivity toward the natural world more holistically and present a practical alternative. Moltmann reminds us that today's growing exploitation of nature by humans stems from a human-centered ecological consciousness that the world belongs to humans. At the same time, it suggests a transition to a God-centered ecological world consciousness. 'A community of creation', 'the fellowship of the Triune God', and 'eschatological new creation through the Sabbath' are key concepts that integrate God-centered ecological world consciousness. Based on Moltmann's creation theory, this article examines the ecological sensibility that Christian education should pursue from the point of view of the sacramental creative community, and reviews the role and practical alternatives of Christian education. Through this, it was derived that the world, including humans, is not owned by humans, but is a sacramental community that is built together toward the end as a part of nature and reveals the glory of God. In addition, it was suggested that Christian education need to be recognized as a suffering subject which mediates humanity and the nature of the mutual fellowship of reconciliation. in the fellowship of God. Sabbath keeping education, which celebrates God's creation and aims for the completion of the eschatological creation, will become a practical area for Christian education to practice for the restoration of the collapsed ecosystem. Moltmann's creation theory is significant in that it provides a meaningful Christian educational insight to restore the ecological environment as well as interest in the ecological environment that has been overlooked or ignored by Christian education.