• Title/Summary/Keyword: deterioration test

Search Result 922, Processing Time 0.037 seconds

Deterioration and Residual Life of Grease for Sealed Ball Bearing (밀봉형 볼베어링용 그리이스의 노화와 잔류수명)

  • 최인혁;김정길;김지현;손성구
    • Tribology and Lubricants
    • /
    • v.18 no.4
    • /
    • pp.273-278
    • /
    • 2002
  • Grease deterioration of mineral oil type grease was investigated using sealed deep groove ball bearings (6203) and bearing life test rig. The bearing test was performed under 3,000 rpm and 245 N radial load at 120。C. Grease taken ken tested bearings was checked in using certain evaluation methods, for example, oxidation induction time (OIT), FT-IR peak intensity, leakage .ate, bleeding .ate, total acid number. (TAN) and bearing noise increase. Within these test conditions, OIT, TAN, bleeding rate were changed gradually in accordance with bearing operating time and showed useful indices for deterioration of grease.

Study on Long-term Deterioration Properties of Porcelain Insulators with Aluminous System (알루미나계 자기애자의 장기 피로특성에 관한 연구)

  • Han, Se-Won;Cho, Han-Goo;Lee, Dong-Il;Cho, In-Hyuk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.562-563
    • /
    • 2005
  • In case of aged porcelain, the failure in basic performance tests happened in cool-heat tests. Based on this characteristic, we studied the method predicting failure phenomena through more severe accelerated cool-heat ageing and accelerating thermal mechanical performance tests. Test results indicated that the thermal stress by temperature gradient was more severe parameter than thermal stress by quenching cycles within a category of standard or accelerating methods. And there is no the deterioration of statistic strength, but the deterioration of strength according to accelerating tests is serious.

  • PDF

Patterns of Resistographs for Evaluating Deteriorated Structural Wood Members

  • LEE, Jun Jae;KIM, Kwang Chul;BAE, Mun Sung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.31 no.6
    • /
    • pp.45-54
    • /
    • 2003
  • The density and strength of wood is affected by degradations and defects, such as voids and knots. Old wooden structures such as traditional cultural properties have been deteriorated by these types of defects. They were evaluated by a visual observation that is difficult to evaluate the inner deterioration in structures. In this study, three nondestructive testing techniques were investigated to detect the wooden structural members. Ultrasonic stress wave tests, drilling resistance tests and visual inspections were used to examine the structural wood members. Patterns of Resistograph using by drilling resistance tests could indicate the features of internal wood such as voids, knots, decay, fungi, and so on. The technique just like as ultrasonic stress wave tests, however, difficult to detect exactly area where small amounts of internal deterioration in logs are. In spite of results of ultrasonic stress wave test, the internal deterioration of wooden structural members could be evaluated by the relationship between ultrasonic stress wave tests and drilling resistance tests.

Analysis of Deterioration Characteristics for Connection Factor according to Connection Method of Grounding System (접지시스템의 접속방식에 따른 접속요소의 열화특성 분석)

  • Gil, Hyoung-Jun;Kim, Hyang-Kon;Kim, Dong-Ook;Kim, Dong-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2126-2127
    • /
    • 2011
  • This paper describes the analysis of deterioration characteristics for connection factor according to connection method of grounding system. The connection method of grounding system is specified in IEC standard. In order to analyze the deterioration characteristics for connection factor, deterioration test was carried out when the connection factor was buried in salt water and underground. The test connection factors were C-type sleeve, clamp, and exothermic welding. As a consequence, most of the connection factor was corroded, and the electrical resistance decreased after deterioration. The analytical results can be used to establish the safety of grounding system.

  • PDF

Performance Evaluation of Repair Methods for RC structures by Accelerating Test in Combined Deterioration Chamber and Long-Term Field Exposure Test (복합열화촉진실험 및 장기현장폭로실험에 의한 RC구조물 보수공법의 보수성능평가)

  • Kwon Young-Jin;Kim Jae-Hwan;Han Byung-Chan;Jang Seung-Yup
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.4 s.35
    • /
    • pp.349-356
    • /
    • 2006
  • At present, the selecting system and analytic estimation criterion on repair materials and methods of the deteriorated RC structures have not yet been set up in domestic. Under these circumstances, deterioration such as shrinkage crack, corrosion of rebar has been often occurred after repair, and this finally results in too frequent repairs. In this study, three types of repair methods were experimentally investigated by the accelerating test in a combined deterioration chamber and long-term field exposure test. Three types of repair methods applied in this study belong to a group of polymer cement mortar, which is commonly used in repair works. According to the results of this study, durability of repair mortar layers and corrosion properties of recovered rebar could be investigated in short period by the accelerating test in a combined deterioration chamber, which can simulate the condition of repeated high-and-low temperature and repeated dry-and-wet environment, spraying chloride solution and emitting $CO_2$ gas. After 36 month long-term filed exposure test in the coastal area, harmful macro-cracks are observed in the polymer cement mortar layer of some repair methods. These crack are considered to result from drying shrinkage of polymer cement mortar. Also, after 36 month exposure, amount of corrosion area and weight loss of rebar are found to be different according to the types of repair methods.

Analysis of Test Results for Small Dipstick-Gage-Type Engine-Oil-Deterioration-Detection Sensor (딥스틱게이지형 소형 엔진오일열화감지센서의 시험결과 분석)

  • Chun, Sang Myung
    • Tribology and Lubricants
    • /
    • v.30 no.3
    • /
    • pp.156-167
    • /
    • 2014
  • This paper presents the test results of small dipstick-gage-type engine-oil-deterioration-detection sensor. The measured sensor signal characteristics for the capacitance and temperature are analyzed. The engine oil deterioration condition correlates with the electrical property of the dielectric constant that comprised with physical properties such as TAN (Total Acid Number), TBN (Total Base Number) and viscosity. Several problems encontered during the test of the sensor system are improved. The results of vehicle tests show that the capacitance signal is stable after the engine stops. Therefore, the sensor should start measuring the parameters for monitoring the engine oil condition after the engine stops. The engine is considered to be in a stopped state if the difference between the maximum and minimum values of the oil capacitance measured every 1 min is below 0.02 pF. The key test results in this paper will help in the development of an engine oil change warning algorithm.

A Compound Deterioration Assessment of Concrete Subjected In Freezing-Thawing and Chloride Attack (동결융해와 염해의 복합작용을 받는 콘크리트의 내구성능 저하 평가)

  • 고경택;김도겸;김성욱;조명석;송영철
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.4
    • /
    • pp.397-405
    • /
    • 2001
  • In clod weather regions, a strong seasonal wind brings sea salts to the land. In addition to it, recently, the spreading amount of deicing salts has increased numerously for purpose of removing snow and ice. Thus the salts environment around concrete structures becomes so severe that various damages of concrete due to applied salts will be brought up. Much of countries such as America, Europe etc. is carried out study for effects of deicing salts on concrete. However, there are not test methods for deterioration of concrete subjected to both freezing-thawing and chloride in Korea. In this study, we carried out test for the compound deterioration subjected to both freezing-thawing and chloride attack, to investigate the effects of sodium chloride on the deterioration of concrete. The test was performed to investigate the effects of cement type, strength and air content on the scaling deterioration of concrete. As a result, the scaling deterioration was accelerated in the presence of salts. And the resistance to scaling was strongly influenced by the type of cement, the strength and air content of concrete.

Deterioration Test of IGBT Devices in Motor Driver (전동기 구동용 IGBT 소자의 열화 진단)

  • Ahn, Jong-Kon;Park, Soon-Myung;Kim, Tae-Gi;Kang, Ju-Hee
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.400-405
    • /
    • 2008
  • Motor is energy converting system to generate mechanical force from electrical power and there are various typed motors in home, office, factory, vehicles, aircraft, shipping, etc. Recently in compliance with performance and reliability and the applications of variable speed motors with invert driver are expanded. Almost high power inverter have IGBT and IGBT's fault cause motor system fault. If we can calculate and foresee troubles of IGBT, we can protect accident caused by motor system fault. In this paper, the deterioration test method of IGBT devices is proposed and the test results of proposed method are shown by evaluated equipment. The basic concept of proposed method is current-voltage characteristic curve test between drain and source of IGBT in open state. The applied voltage type is ramp and it is confirmed that the current-voltage curvet pattern of IGBT in open state represents IGBT's deterioration state.

  • PDF

Evaluation of Deterioration of Epoxy Primer for Steel Bridge Coating using Image Processing and Electrochemical Impedance Spectroscopy (화상처리 기법과 전기화학적 임피던스 분광법을 이용한 강교 도장용 에폭시 하도 도료의 열화 평가)

  • Lee, Chan Young;Lee, Sang Hun;Park, Jin Hwan
    • Corrosion Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.53-61
    • /
    • 2009
  • In this study, both evaluations by visual imaging for exterior view of coating and by EIS were executed for epoxy primer coated specimens deteriorated by accelerated test, and comparison and analysis were carried out for 2 evaluation methods. In the comparison between total damaged area ratio acquired by image processing method and deterioration point, higher deterioration points were appeared for rusted specimens than for non-rusted specimens. It is attributed that deterioration point per unit area ratio given for rust is higher than for peeling. In the comparison between total damaged area ratio and EIS result, impedance of coating was largely decreased as about TEX>$10^4{\Omega}{\cdot}cm^2$ or less when rust area ratio is more than about 0.1%, and blistering area ratio is more than about 3%. Charge transfer resistance ($R_{ct}$) and double layer capacitance ($C_{dl}$) values were appeared for all specimens except 2 ones, which shows that water is accumulated and steel substrate is corroded at coated film-steel interface. In the comparison between deterioration point and EIS result, more than 10 points as deterioration point were given for specimens of below $10^6{\Omega}{\cdot}cm^2$ of impedance at low frequency. For specimens deteriorated by NORSOK cyclic test, impedance was lowest of all, though deterioration point was not high. It is thought to be attributed that coating system and accelerated deterioration condition of cyclic tested specimens were different from those of main specimens. From the result, it is thought that coating resistance can be relatively more decreased than deterioration degree estimated from exterior view under more severe corrosion environment or in the present of more complex deterioration factors.

State of Visual Acuity Test and Factors Related to Vision Deterioration of Preschoolers (미취학 아동의 시력검진 실태와 시력저하 관련요인)

  • Lee, Sunghwa;Lee, Haejung
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.12
    • /
    • pp.132-142
    • /
    • 2016
  • The study aimed to examine the state of visual acuity tests in preschoolers and determine the factors affecting the deterioration of their vision. A total of 172 pair, child aged 5-7 years and either one of their parents, were recruited from childcare centers or kindergarten between August 2015 and January 2016. Questionnaires were administered to the parents, and the children's visual acuities were measured. Using forward selection in logistics regression analysis, factors affecting vision deterioration were elucidated. Of 172 children, 128 (74.4%) had undergone a visual acuity test previously and 77 (44.8%) showed a deterioration in their vision. Children who had undergone their first visual acuity test after the age of 7 years (OR=7.425, CI=2.844- 19.385) and showed more abnormal eye symptoms, such as squinting or tilting the head to see or falling down frequently (OR=3.084, CI=1.202-7.914) and whose age was younger (OR=10.335, CI=3.252-32.848), were more likely to develop deterioration of vision. Children who had a posture such that they looked up at the computer monitor from below (OR=.075, CI=.022-.255), were less likely to show deterioration of vision. It can be inferred that early visual acuity tests is essential to detect deteriorated vision of preschoolers. Therefore, it is necessary to educate parents, personnels in day care center, and health clinics about the importance of early visual acuity tests and close observation of specific behaviors related to vision deterioration. Development of precautionary intervention program of vision deterioration in preschoolers and examination of its effects are needed.