• Title/Summary/Keyword: deterioration rate

Search Result 667, Processing Time 0.029 seconds

Effect of Systematic Educational Program for the Application of National Institutes of Health Stroke Scale (NIHSS) as a Neurologic Assessment Tool in Stroke Patients (뇌졸중의 신경학적 사정 도구인 NIHSS 적용을 위한 체계적인 간호사 교육 프로그램의 효과)

  • Han, Jung Hee;Lee, Gee Eun;An, Young Hee;Yoo, Sung Hee
    • Journal of Korean Clinical Nursing Research
    • /
    • v.19 no.1
    • /
    • pp.57-68
    • /
    • 2013
  • Purpose: In assessing patients' neurological status following a stroke it is very important to have a valid tool for early detection of neurological deterioration. NIHSS is considered the best tool to reflect neurological status in patients with ischemic stroke. An education program on use of NIHSS was planned for nurses caring for these patients and the effects of the program were evaluated. Methods: The NIHSS education program (NEP) which includes online and video lectures, and practical education was provided to the nurses from April to July, 2010. To examine the effect of NEP, nursing records of patients with ischemic stroke who were admitted to a stroke center were analyzed. Two groups, a historical control group (n=100) and the study group (n=115) were included. Results: Nursing records for neurologic symptoms for each patient increased (41.0% versus 100.0%, p<.001), and especially, visual disturbance, facial palsy. limb paralysis and ataxia, language disturbance, dysarthria, and neglect symptoms significantly increased (all p<.001). Nurse notification to the doctor of patients with neurological changes increased (21.0% versus 39.1%, p=.004), and nurses' neurological deterioration detection rates also increased (37.5% versus 84.6%, p=.009). Conclusion: NEP improved the quality of nursing records for neurological assessment and the detection rate of neurological deterioration.

Study on Mutual Relation between the Level of Deterioration Influenced by the Changes of Chemical and Physical Properties and the Change of Dielectric Constant for Engine Oil - Gasoline Engine Oil (엔진오일의 화학적 및 물리적 변화에 의한 퇴화정도와 유전상수 변화에 관한 상호관계 연구 - 가솔린엔진오일)

  • Chun, Sang-Myung
    • Tribology and Lubricants
    • /
    • v.22 no.5
    • /
    • pp.260-268
    • /
    • 2006
  • The dielectric constants of used gasoline engine oils were obtained at a few temperatures and a frequency. Through analyzing the characteristics of dielectric constant, the related correlation between the changes in dielectric constants of oil and the degree of oil deterioration is going to be found. The dielectric constant was calculated using cross capacitances measured by a sensor tube. As results of the measurement of the fresh engine oil's dielectric constant, it was found that the value of dielectric constant was set down below $60^{\circ}C$ regardless changing frequency. Further, above 6 kHz, the dielectric constant was set down even if temperature was above $100^{\circ}C$ Therefore, for the measurement of used oils, it was selected the frequency of 6 kHz,,and the temperature of $80^{\circ}C$ preventing a certain ionic-conduction effects on the measured dielectric constant and the evaporation of a certain fluid mixed with engine oil. Specially, the effects of the mixing fluid like coolant, water and fuel on the fresh engine oil's dielectric constant were studied. It was found that the oil mixed with coolant showed the highest value, next water, and the lowest fuel. As results of the measurement of the used engine oil's dielectric constant, it was found that the possible changed rate of the used engine oil's dielectric constant based on the warning limit for engine oil in service was below 4% for gasoline engine oil.

Study on Mutual Relation between the Level of Deterioration Influenced by the Changes of Chemical and Physical Properties and the Change of Dielectric Constant for Engine Oil - Diesel Engine Oil (엔진오일의 화학적 및 물리적 변화에 의한 퇴화정도와 유전상수 변화에 관한 상호관계 연구 - 디젤엔진오일)

  • Chun, Sang-Myung
    • Tribology and Lubricants
    • /
    • v.22 no.5
    • /
    • pp.290-300
    • /
    • 2006
  • The dielectric constants of used diesel engine oils were obtained at a few temperatures and a frequency. Through analyzing the characteristics of dielectric constant, the related correlation between the changes in dielectric constants of oil and the degree of oil deterioration is going to be found. The dielectric constant was calculated using cross capacitances measured by a sensor tube. As results of the measurement of the fresh engine oil's dielectric constant, it was found that the value of dielectric constant was set down below $60^{\circ}C$ regardless changing frequency. Further, above 6 kHz, the dielectric constant was set down even if temperature was above $100^{\circ}C$. Therefore, for the measurement of used oils, it was selected the frequency of 6 kHz, and the temperature of $80^{\circ}C$ preventing a certain ionic-conduction effects on the measured dielectric constant and the evaporation of a certain fluid mixed with engine oil. Specially, the effects of the mixing fluid like coolant, water and fuel on the fresh engine oil's dielectric constant were studied. It was found that the oil mixed with coolant showed the highest value, next water, and the lowest fuel. As results of the measurement of the used engine oil's dielectric constant, it was found that the possible changed rate of the used engine oil's dielectric constant based on the warning limit for engine oil in service was below 10% for diesel engine oil.

Experimental Study on the Strength Improvement and the Long Term Durability of Shotcrete mixed Micro-Silica Fume (실리카 흄을 혼입한 숏크리트의 강도증진과 장기내구특성에 관한 실험적 연구)

  • Ma, Sang-Joon;Kim, Dong-Min;Jang, Phil-Sung;Choi, Jae-Seok
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.8 no.2
    • /
    • pp.165-182
    • /
    • 2006
  • In this study, field test was performed to investigate the strength-improvement effect of shotcrete mixed Micro-silica fume and shotcrete quality was estimated by EFNARC standard. Deterioration test combined the Freezing-thawing and Carbonation was also performed in order to investigate a long-term durability of high-strength shotcrete. As a result of test, the compressive strength of shotcrete using Micro-silica fume was 45.2~55.8MPa and flexible strength was 5.01~6.66MPa, so a promotion ratio of strength was 37~79%, 17~61% respectively. And the strength-improvement effect of strength by silica fume addition ratio of 7.5~10% for cement mass was more superior to the others. Due to relative dynamic modulus, mass decrease rate and carbonation progress of shotcrete mixed Micro-silica fume, it was especially realized that Micro-silica fume reduced deterioration caused by steel fiber and improved a long-term durability of shotcrete.

  • PDF

An Analysis on the Correlation between Crack Condition and Safety Grades in Masonry Buildings (조적조 건축물의 균열양태 및 등급판정과의 상관성에 관한 연구)

  • Kwon, Ki-Hyuk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.3
    • /
    • pp.101-110
    • /
    • 2005
  • In Seoul, structural deterioration is severe in the private masonry buildings which have been built since 1906s. But most of these structures remain without any repair works. As a result, the rate of deterioration is getting faster and these dangerous structures may cause hazardous circumstances to the adjacent structures and neighborhood. The purpose of this study is to investigate the actual conditions of wall cracks among the defect types which occur in private masonry buildings and to analyze the correlation between safety grades and wall cracks for offering the fundamental data. Using these date we can establish basic criteria for safety grades of structures and improve the quality of masonry buildings. The result of this study indicate that there are high correlations between safety grades and the width of crack but much less so with the length. Furthermore, with regard to crack patterns, vertical cracks much more negatively effected the safety grades.

Study on the Contractile Force of the Isolated Hearts from Ginseng Components Treated Rats (흰쥐 심장의 수축력에 미치는 인삼성분의 효과)

  • 김낙두;김봉기;이혜선
    • YAKHAK HOEJI
    • /
    • v.26 no.4
    • /
    • pp.239-251
    • /
    • 1982
  • The rate of deterioration of contractile force of isolated hearts from control and panax ginseng treated rats was determined and response of contractile force of the hearts from ginseng treated rats to several autonomic and other drugs was investigated. Rats weighing 150-250g were administrered orally with ginseng ethanol extract (100mg/kg) and total ginseng saponin (50mg/kg/day) for a week. Ginsenoside Rb$_{1}$ (5mg/kg/day) and ginsenoside Re (5mg/kg/day) were administered respectively for a week. The isolated hearts from rats were perfused with Krebs-Henseleit solution by using Langendorff perfusion apparatus. The control group was only able to maintain approximately 75.5% of their initial strength after 60 min of perfusion, whereas ginseng ethanol extract, total ginseng saponin treated hearts were able to sustain nearly their initial strength even after 60 min. Ginsenoside Rol treated hearts also sustained 93% of their initial strength, but there was no significant difference in the deterioration percentage of the contractile force of ginsenoside Re treated hearts. Experiments were conducted to study the response to perfusion of ginseng treated animal heart with epinephrine, isoproterenol, propranolol, and phenobarbital. The isolated hearts were perfused with Krebs-Henseleit solution containing epinephrine (10$^{-6}$ M), isoproterenol ($10^{-7}$M), propranolol ($10^{-6}$M) and phenobarbital (7{\times}10^{-3}M$) respectively. The maximum inotropic effect of epinephrine and isoproterenol was observed after 2~3 minutes of drug perfusion. Effect of epinephrine on ginseng ethanol extract and total ginseng saponin treated hearts was reduced compared with control. On the other hand, this phenomenon was not observed in ginsenoside Re treated rats but on ginsenoside $Rb_{1}$ treated rats. The positive inotropic effect of isoproterenol was reduced in the hearts from ginseng treated rats compared with control heart, Propranolol or phenobaribital decreased the contractile force in the control rats. The depressant effect of propranolol and phenobarbitat on ginseng treated rat hearts was less than those of control rat hearts. The result suggest that ginseng ethanol extract , ind total ginseng saponin and ginsenoside $Rb_{1}$ may protect the deterioration of contractile force of the heart and may attenuate the response to several drugs on hearts.

  • PDF

A Study on Improvement of Inspection Activity Based upon Condition Analysis of Expressway Bridges (고속도로 교량의 상태 분석에 근거한 점검 활동 개선에 관한 연구)

  • Jeon, Jun Chang;Lee, Il Keun;Park, Chang Ho;Lee, Hee Hyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.1
    • /
    • pp.19-28
    • /
    • 2017
  • In this paper, detailed safety inspection reports on the 915 expressway bridges which had been published from 1996 to 2010 are collected and condition of these bridges are analyzed. Damages are categorized into 'damage by defect', 'damage by physical force', and 'damage by deterioration' and the concept of damage possession rate is introduced to investigate the occurrence time and the characteristics of damages. Based on the top 10 damage patterns of expressway bridges and the deterioration characteristics of heavy snow and freezing cold area, reasonable improvement direction of inspection activity is suggested. From this study, it is known that improvement of inspection regularization during construction or at completion stage of bridges is needed. Since the deterioration progress of the heavy snow and freezing cold area is faster than that of general area, environmental characteristics should be considered in inspection activity. The results of present study can be widely used for improvement of inspection activity of expressway bridges.

The Changes of Capsaicinoids and AST A Color Value of Red Pepper Powder Packed with Different Packaging Materials (포장재를 달리한 고춧가루의 저장조건에 따른 capsaicinoids와 색상 함량 변화)

  • 이선미;박재복;김선아;황인경
    • Korean journal of food and cookery science
    • /
    • v.19 no.4
    • /
    • pp.439-446
    • /
    • 2003
  • This study was performed to investigate the change in the chemical components of red pepper powder using different packaging materials and various storage conditions. Red pepper powders with 11 and 15% initial moisture content were packed with five different materials and stored at different temperatures (0, 20, and 30 C) for a one year period. Over the storage period, each combination was periodically sampled, and examined for composition changes. The five packaging materials were: linear low density polyethylene(LLDPE), nylon/LLDPE(Ny/LLDPE), saran coated ethylene vinyl acetate copolymer/linear low density polyethylene(B650), nylon/Tie/nylon/ethylene-vinyl alcohol copolymer/nylon/Tie/LLDPE(RDX-2787) and oriented polypropylene/alumimum/LLDPE(OPP/Al/LLDPE), and the three storage conditions were (28.3${\pm}$1.0)$^{\circ}C$ with (15.5${\pm}$2.8)% relative humidity, (18.6${\pm}$0.5)$^{\circ}C$ with (46.6${\pm}$4.9)% RH, and (0${\pm}$2)$^{\circ}C$ with (80${\pm}$10)% RH, respectively. The moisture contents of all samples changed according to the relative storage humidity, except those of the samples packed with OPP/Al/LLDPE, which remained constant throughout the storage period. The capsaicinoids content of the red pepper powder did not change significantly for 6 months, but gradually decreased after that until about 85% of the original amount remained at the final stage of storage. The ASTA color values of all samples decreased gradually throughout the storage period. The higher the storage temperature, the more severe the deterioration. The color deterioration seemed greatly related to the existence of oxygen, as the deterioration was especially severe in the samples packed with LLDPE and B650, where the oxygen transmission rate were highest among the five packaging materials.

A Case Report on Posterior Circulation Cerebral Infarction with Early Neurological Deterioration in an Elderly Patient with Chronic Kidney Disease (고령의 만성콩팥병 환자에서 발생한 초기 신경학적 악화가 동반된 후방순환뇌경색 치험 1례)

  • Kim, Jun-seok;Lee, Yoo-na;An, Yu-min;Baek, Kyung-min
    • The Journal of Internal Korean Medicine
    • /
    • v.42 no.5
    • /
    • pp.727-737
    • /
    • 2021
  • Objectives: This study investigated the effect of Korean medicine on an elderly patient with posterior circulation cerebral infarction, chronic kidney disease (CKD), and early neurological deterioration (END). Methods: The patient, who already had CKD, was treated with Korean medicine, comprising herbal medicine, acupuncture, moxa, and cupping combined with Western medicine (antiplatelet, diabetes) and physical therapy. A manual muscle test (MMT) and a modified Barthel index (MBI) were used to observe the treatment effects, and blood tests were performed to check estimated glomerular filtration rate (eGFR), creatinine and blood urea nitrogen (BUN), which represent renal function. Results: After the treatment, MMT, MBI, and renal function scores had increased. Conclusions: This study suggests that Korean medicine can effectively treat posterior circulation cerebral infarction with END in CKD, but further studies should be conducted.

The Optimized Standards and Criteria for Installing Switches on Distribution Feeder (국내 배편계통의 최적 개폐기 설치 기준)

  • Jo, Nam-Hun;Ha, Bok-Nam;Lee, Heung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.5
    • /
    • pp.238-246
    • /
    • 2002
  • Utilities are trying to install the equipment of high quality to avoid deterioration of supply reliability. In addition, many sectionalizing switches which can decrease the total outage value for a fault are installed for the same reason. Therefore, utilities are interested in stun dards and criteria for installing switches to optimize the total cost on distribution systems. The affect of sectionalizing switches installed on distribution feeder is gradually decreased because the failure rate on distribution feeder is decreased. Also the automation for distribution systems is widely applied for the efficient operation. Therefore, the renewal for installation standards of sectionalizing switches Is required to reflect the current operation situation. The variable data is used to consider the KEPCO's real situation of distribution feeder as follows; the feeder capacity, connecting rate, feeder length, failure rate of distribution feeder, the failure rate of switches, perception time of feeder fault, the restoration time for a faulted section, the transfer time to other feeders, and the switching time. In this study, We propose equations which can determine the number of sectionalizing switches for minimizing the outage and switch installation cost.