• 제목/요약/키워드: deterioration point

검색결과 229건 처리시간 0.03초

Effects of Bottom Inflow Area on Pool Boiling Heat Transfer in a Vertical Annulus (하부 유로단면적이 수직 환상공간 내부 풀비등열전달에 미치는 영향)

  • Kang, Myeong-Gie;Yoo, Joo-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제31권7호
    • /
    • pp.604-610
    • /
    • 2007
  • To investigate effects of the inflow area on pool boiling heat transfer in a vertical annulus, the inflow area at its bottom has been changed from 0 to $1060.3mm^2$. For the test, a heated tube of 34 mm diameter and water at atmospheric pressure have been used. To elucidate effects of the inflow area on heat transfer results of the annulus are compared to the data of a single unrestricted tube. The change in the inflow area at the bottom of the annulus results in much variation in heat transfer coefficients. When the inflow area is $113.1mm^2$ the deterioration point of heat transfer coefficients gets moved up to the higher heat fluxes because of the convective flow at the bottom regions.

A Study on the Unique point about the Tracking at Electrical fire spot (화재현장에서 분석 절차에 따른 전기화재 조사기법 개발)

  • Kim, Dong-Ook;Lee, Ki-Yeon;Gil, Hyung-Jun;Kim, Hyang-Kon;Chung, Young-Sik
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.2130-2131
    • /
    • 2011
  • Electric fire breaks out by various causes such as electric short, overload(over current), leakage current, poor contact, static electricity, insulation deterioration, partial disconnection and etc. In this paper, we studied analysis technique for scientific and systematic judgment for distinction of electricity fire existence and nonexistence, and described about electricity fire cause analysis process for collecting physical evidences. We handled external form analysis, Substance extension analysis, X-ray transmission analysis, cross-section analysis, thermal analysis, chemical structure analysis, surface structure analysis, component analysis, electrical properties analysis, and circuit analysis by analysis technique for electricity fire cause judgment. We expect that analysis technic elevation and correct cause of fire analysis of scene of a fire investigators and analysts through this paper which see help.

  • PDF

Water Absorption Sensor of Generator Stator Bar Insulation using Cross Capacitance (크로스 커패시턴스를 이용한 발전기 고정자 권선 절연물 흡습 측정 센서)

  • Bae, Yong-Chae;Kim, Hee-Soo;Lee, Doo-Young;Lee, Wook-Ryun;Lee, Rae-Deok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • 제60권10호
    • /
    • pp.1972-1977
    • /
    • 2011
  • The mechanical integrity of generator stator windings is one of the critical point because the electric power is generated and conducted to power system through these windings. To cool down the heat emitted from generator winding during its operation, a majority of generators use de-mineralized water characterized by high cooling efficiency. Contrary to such the excellent cooling efficiency, however, the damaged bar insulations attributed to the absorption of cooling water in the generator stator winding lead to highly time- and cost consuming efforts as well as to service deterioration due to unexpected forced outage of generator. It is described that the new design of water absorption sensor using cross capacitance for generator in power plant in order to increase the reliability of water absorption diagnostics for generator stator bar insulation.

Cohesive modeling of dynamic fracture in reinforced concrete

  • Yu, Rena C.;Zhang, Xiaoxin;Ruiz, Gonzalo
    • Computers and Concrete
    • /
    • 제5권4호
    • /
    • pp.389-400
    • /
    • 2008
  • In this work we simulate explicitly the dynamic fracture propagation in reinforced concrete beams. In particular, adopting cohesive theories of fracture with the direct simulation of fracture and fragmentation, we represent the concrete matrix, the steel re-bars and the interface between the two materials explicitly. Therefore the crack nucleation within the concrete matrix, through and along the re-bars, the deterioration of the concrete-steel interface are modeled explicitly. The numerical simulations are validated against experiments of three-point-bend beams loaded dynamically under various strain rates. By extracting the crack-tip positions and the crack mouth opening displacement history, a two-stage crack propagation, marked by the attainment of the peak load, is observed. The first stage corresponds to the stable crack advance, the second one, the unstable collapse of the beam.

Measurement Methods of Latent Heat for PCM with Low Melting Temperature in Closed Tube

  • Hong Hiki;Kang Chaedong;Peck Jong Hyeon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권4호
    • /
    • pp.206-213
    • /
    • 2004
  • Cycle test for developed phase change material (PCM) is necessary in order to assess the variation of latent heat, which decreases with time by deterioration. T-history method and measurement using heat-flux meter are appropriate for the cycle test in a tube filled with PCM because they do not need an extraction of sample in measuring heat of fusion. In the present study, these methods were applied to a PCM having a melting point below a room temperature, different to the past studies for PCMs melting above a room temperature. As a result of experiment using pure water as specimen, we can obtained rea-sonable values for heat of fusion.

Development of Wasteless Mold for rubber molding Part (고무 성형제품의 Wasteless 금형 개발에 대한 연구)

  • Choi N.J.;Huh Y.M.;Kang S.S.;Park S.B.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 한국소성가공학회 2004년도 춘계학술대회 논문집
    • /
    • pp.101-104
    • /
    • 2004
  • The application of rubber produt is a quite extensive field and has several problems in point of mass-production. The inhibitive factors at the general rubber mold are occurrence of flash, loss of raw material by curing for sprue and runner, environmental pollution by scrap junked after extraction of product and the unavailable mold structure for automation. The existence of flash at the rubber mold requires extra-process for removing or finishing it. As the reason, we can't help avoiding deterioration of quality and rising of cost. Hence we promptly need to research fur the efficient structure of mold and the preventive transforming technique of the flash without any loss of raw material in advance. This monograph is a study for Wasteless rubber mold that give us a solution for several problems happened at the general rubber mold.

  • PDF

Application of Acoustic Emission Technique for Crack Source Location Search in Plain Concrete (무근 콘크리트에서 균열 발생원 탐사를 위한 AE 기법의 적용)

  • 한상훈;이웅종;조홍동;김동규
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.793-798
    • /
    • 1999
  • This study was conducted to evaluate structural integrity and crack source location of plain concrete beams using acoustic emission. Three point bending tests were carried out plain concrete specimen under cyclic loadings. The variable is W/C of concrete. From the tests it was shown that a breakdown of the kaiser effect and high AE activities during unloading could be effective indices to estimate the level of deterioration in plain concrete structures. The time and location and propagation of crack could be easily determined by monitoring AE, which concludes that AE technique can be a very useful tool to evaluate structural integrity of concrete plain beams.

  • PDF

Pressure Distributions of a Screw-type Centrifugal Pump Operating in Air-Water Two-Phase Flow (기액 이상류시의 스크류식 원심펌프의 압력분포)

  • Kim, You-Taek;Choi, Min-Seon;Lee, Young-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • 제4권3호
    • /
    • pp.39-45
    • /
    • 2001
  • It is reported recently that the pump head deterioration near the best efficiency point, from single-phase flow to the choke due to air entrainment became less in a screw-type centrifugal pump than in a general centrifugal pump. Moreover, at a narrow tip clearance, the pump head became partially higher in two-phase flow than that in single-phase flow. However, the internal pressure fluctuations on this pump due to air entrainment have not been studied yet. For that reason, we have examined the influences of void fraction, flow coefficient and impeller tip clearance on pressure fluctuations in the casing. The void fraction became larger, the influence of tip clearance on pressure distribution became less.

  • PDF

Studies on the establishing a lawn of Zoysia Japonica Steud with the seeds. Part I.Investigation of the physiological maturity of seeds. (한국잔디(Zoysia Japonica Steud)의 실생번식법 확립에 관한 연구 I. 종자의 생리적 성숙기 조사)

  • 전우방
    • Asian Journal of Turfgrass Science
    • /
    • 제3권2호
    • /
    • pp.65-72
    • /
    • 1989
  • Tes ratablish a liawn Zoysia' Japonica Steud. with seeds. a experiment was conducted for the invrati ignt ic in oil seed's physic sit ogical maturity. The rt.sultt an' Summarized as follows: 1. The point of maximum weight off 1000 seeds and 100 seedling, germination speed and germination percentage were reached at 30 day. after anthesis. it would be considered as physiological maturity of Zoysia japonica seed. 2. The seeds moistures contents at physiological maturity was decreased in 18%. 3. Germination vigor deteriorated prior to viability. 4. The seeds were capable of germination in 3:4% at 10 days after anthesis. 5. Field deterioration of seeds occurer from 40 (lays after anthesis to 60 days and sprouted seedilng vigor was very poor.

  • PDF