• Title/Summary/Keyword: deterioration method

Search Result 1,262, Processing Time 0.038 seconds

Deterioration Evaluation of Railway Line Segments for Budget Distribution (예산배분을 위한 철도선로구간의 노후도 평가)

  • Kim, Seong-Ho;Choi, Chan-Yong;Na, Hee-Seung
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1802-1809
    • /
    • 2011
  • A distribution method of limited budget for rail line facility improvement is to use investment priorities of rail line segments based on their deterioration. In this paper we present an evaluation method of rail line segment deterioration which can be used to distribute limited budget. Rail line facilities include rail track, crossing, road bed, bridge, tunnel. These facilities deterioration and line shape can affect line segment deterioration. Deterioration evaluation method we present is a weighted sum of each component deterioration scores. The component weight can be obtained from experts using analytic hierarchy process.

  • PDF

Evaluation Method of Deterioration Grade for Remodeling Old Educational Facilities(III) - Synthetic Judgment Method of Deterioration Grade of Finished Materials - (교육시설(敎育施設)의 리모델링을 위한 구성재료(構成材料)의 노후화(老朽化) 판정기준(判定基準) 작성(作成)(III) - 주요(主要) 마감재료(材料)의 노후도(老朽度) 종합판정방법(綜合判定方法) 제시(提示) -)

  • Seo, Chee-Ho;Choi, Min-Kwon;Choi, Soo-Kyung;Oh, Se-Chul;Kwon, Yong-Kyun
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.11 no.1
    • /
    • pp.15-23
    • /
    • 2004
  • Deterioration of the educational facilities built before 1985 is a serious situation. The purpose of this study is to present the efficient remodeling method of old educational facilities. This paper, part III, presents the systemic and synthetic judgment method of deterioration grade of finished materials. Evaluation of the deterioration is carried out in every eight classrooms or building elements divided by the use. And classrooms are divided by several parts for example floor, wall and ceiling etc.. The whole deterioration of the building judges the result of every part collectively.

Evaluation Method of Deterioration Grade for Remodeling Old Educational Facilities(II) - Synthetic Judgment Method of Deterioration Grade of Structural Components - (교육시설(敎育施設)의 리모델링을 위한 구성재료(構成材料)의 노후화(老朽化) 판정기준(判定基準) 작성(作成)(II) - 주요(主要) 구성부재(構造部材)의 노후도(老朽度) 종합판정방법(綜合判定方法) 제시(提示) -)

  • Seo, Chee-Ho;Choi, Min-Kwon;Choi, Soo-Kyung;Oh, Se-Chul
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.10 no.5
    • /
    • pp.15-22
    • /
    • 2003
  • Deterioration of the educational facilities built before 1985 is a serious situation. The purpose of this study is to present the efficient remodeling method of old educational facilities. This paper, part II, presents the systemic and synthetic judgment method of deterioration grade of structural components. Deterioration grade of the whole structural components are judged by synthetic evaluation score which is the total of the score of ten evaluation items. And we added the importance coefficient of the viewpoint of four performance to each evaluation item.

A Study on the Short-Term Deterioration Test Method of MgO in AC PDP (AC PDP 보호막 MgO의 단시간 열화시험방법에 관한 연구)

  • 김윤기;허정은;김영기;이호준;박정후
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.12
    • /
    • pp.578-583
    • /
    • 2002
  • For ac PDP, the lifetime should be guaranted over, 30000 hours. The lifetime is correlated with the deterioration characteristics for the weakest element in ac PDP. However, the short-term deterioration test method of the at PDP has not well developed. In this paper, a short term deterioration test method of a given element in the ac PDP is proposed. By this method, MgO deterioration characteristics are investigated. The deterioration rate is decreased with MgO thickness but it was almost saturated over 5000$\AA$.

Behavior of Seepage and Seismic for the Deterioration Reservoir Using Numerical Analysis (수치해석에 의한 노후저수지의 침투 및 동적거동)

  • Park, Sung-Yong;Chang, Suk-Hyun;Lim, Hyun-Taek;Kim, Jung-Meyon;Kim, Yong-Seong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.58 no.3
    • /
    • pp.81-90
    • /
    • 2016
  • It is significant to redevelop the deterioration reservoir through raising for countermeasure to climate change and Earthquake improvement of reservoir. This study aims to investigate the behavior of deterioration reservoir with poor-fabricated core subjected to raising water level and earthquake using numerical analysis. From the analysis results, water level raising and earthquakes induce crack and subsidences at the crown and the front side of deterioration reservoir. For the reinforcement of the deterioration reservoir is required appropriate measures method and raised method suitable, drainage and slope protection method judged to be necessary.

A Study on the Deterioration Prediction Method of Concrete Structures Subjected to Cyclic Freezing and Thawing (동결융해 작용을 받는 콘크리트 구조물의 내구성능 저하 예측 방법에 관한 연구)

  • Koh, Kyung-Taeg;Kim, Do-Gyeum;Cho, Myung-Sung;Son, Young-Chul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.1
    • /
    • pp.131-140
    • /
    • 2001
  • In general, the deterioration induced by the freezing and thawing cyclic in concrete structures often leads to the reduction in concrete durability by the cracking or surface spalling. If it can prediction of concrete deterioration subjected to cyclic freezing and thawing, we can rationally do the design of mix proportion in view of concrete durability and the maintenance management of concrete structures. Therefore in this study a prediction method of deterioration for concrete structures subjected to the irregular freezing and thawing is proposed from the results of accelerated laboratory freezing and thawing test using the constant temperature condition and the in-situ weathering data. Furthermore, to accurately predict the concrete deterioration, a method of modification for the effect of hydration increasing during rapid freezing and thawing test is investigated.

  • PDF

Deterioration Evaluation of Railway Line Segments Using Analytic Hierarchy Process (AHP를 활용한 철도선로구간 노후도 평가)

  • Kim, Seong-Ho
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.6
    • /
    • pp.569-574
    • /
    • 2011
  • An effective approach to distributing budget to railway line facility improvement is to use investment priorities of railway line segments based on their deterioration. In this paper we present an evaluation method of railway line segment deterioration which can be used to distribute limited budget. Railway line facilities include rail track, railroad switch, subgrade, bridge, tunnel. These facilities and line shape can affect line segment deterioration. Deterioration evaluation method we present is a weighted sum of each component deterioration scores. The component weight can be obtained from experts using analytic hierarchy process.

Making Method of Deterioration Map and Evaluation Techniques of Surface and Three-dimensional Deterioration Rate for Stone Cultural Heritage (석조문화유산의 손상지도 제작방법과 표면 및 3차원 손상율 평가기법)

  • Jo, Young-Hoon;Lee, Chan-Hee
    • Journal of Conservation Science
    • /
    • v.27 no.3
    • /
    • pp.251-260
    • /
    • 2011
  • This study focus on the suggestion of standard legend, the process system on making method of deterioration map, the development of crack index (CI), and the evaluation techniques of surface and 3D deterioration rate for stone cultural heritage. The standard legends of deterioration forms were made using a common graphic program after crack, blistering, scaling, break-out, granular disintegration, and perforation were subdivided. The deterioration map improved accuracy and reliability on deterioration range using 3D digital restoration and high resolution photograph mapping technique. Also, quantitative deterioration evaluation of stone cultural heritage was carried out developing the crack index, and the 3D deterioration rate of a break-out part was calculated by virtual restoration modeling. As a quantitative deterioration evaluation of Magoksa Temple stone pagoda based on the results described above, the north face showed high deterioration rate of bursting crack (1.70), hair crack (1.34), scaling (20.2%) and break out (13.0%), and the 3D deterioration rate of first roof stone was 6.7%.

Research on Assessment Method of Deterioration Condition for Power Transformer Using Sweep Frequency Response Analyzer (주파수응답분석기를 이용한 전력용 변압기 열화상태 평가방법 연구)

  • Gil, Hyoung-Jun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.8
    • /
    • pp.30-35
    • /
    • 2013
  • This paper describes the assessment method of deterioration condition for a power transformer using SFRA. Frequency Response Analysis(FRA) is a method to evaluate the mechanical and geometrical integrity of the core and windings within a power transformer by measuring the electrical transfer functions over a wide frequency range. SFRA is sweep frequency response analyzer for power transformer winding diagnosis. The FRA is a comparative method, that evaluates the transformer condition by comparing the obtained set of FRA results to reference results on the same, or a similar, unit. FRA techniques were widely used and much more sensitive than the traditional and internationally accepted method of impedance measurements, but that work was required on standardization and interpretation. In order to analyze the deterioration condition for power transformer, overvoltage test and mechanical distortion test were carried out. The deterioration condition for power transformer was evaluated by SFRA. It is intended to present the elemental technology of assessment method for power transformer using SFRA.

Analysis of Deterioration Characteristics for Connection Factor according to Connection Method of Grounding System (접지시스템의 접속방식에 따른 접속요소의 열화특성 분석)

  • Gil, Hyoung-Jun;Kim, Hyang-Kon;Kim, Dong-Ook;Kim, Dong-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2126-2127
    • /
    • 2011
  • This paper describes the analysis of deterioration characteristics for connection factor according to connection method of grounding system. The connection method of grounding system is specified in IEC standard. In order to analyze the deterioration characteristics for connection factor, deterioration test was carried out when the connection factor was buried in salt water and underground. The test connection factors were C-type sleeve, clamp, and exothermic welding. As a consequence, most of the connection factor was corroded, and the electrical resistance decreased after deterioration. The analytical results can be used to establish the safety of grounding system.

  • PDF