• Title/Summary/Keyword: deterioration degree

Search Result 308, Processing Time 0.032 seconds

Deterioration Mechanism of Paper According to Sizing and Beating (II) -Influences of Beating- (사이징과 고해에 따른 종이의 열화기구(제2보) -고해의 영향-)

  • 김봉용
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.31 no.2
    • /
    • pp.58-63
    • /
    • 1999
  • Three kinds of papers were prepared from different beating degree of pulps. Physical and optical properties were examined to elucidate the deterioration mechanism of paper according to beating degrees. Changes of double folds, elongation, water retention value, DP, K/S value and visible, UV region light absorption spectra of those papers treated by UV light were studied. Double folds and brightness were decreased more rapidly by UV treatment with increasing of beating degree. The light absorption rates of pulps in visible and UV region were also increased with change of beating level. The formation of new hydrogen bonds and higher light absorption rate of pulps according to beating induced to absorb and interact with much UV light. These phenomena maybe brought about to accelerate paper deteriortion by UV treatment both optical and physical properties.

  • PDF

Safety Assessment and Capacity Rating of Existing P.C, Bridges based on Reliability Methods (신뢰성 방법에 기초한 기설 P.C교의 안전도 및 내하력 평가)

  • 조효남;김민영;서종원
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1990.10a
    • /
    • pp.45-50
    • /
    • 1990
  • This study develops practical models and methods for the assessment of safety and capacity rating of existing P.C. girder bridges based on the reliability methods. One of the main objectives of the study is to propose a practical but realistic limit state model for safety assessment and LRFR rating criteria, which explicitly incorporates the degree of deterioration and damage as well as actual condition of P.C. girder bridges in terms of the damage factor and the response ratio. The damage factor proposed in the paper is defined as the ratio of the current estimated stiffness to the intact base-line stiffness of a member. Based on the observation and the results of applications to existing bridges, it may be concluded that the proposed methods for the assessment and capacity rating models, which explicitly account for the uncertainties and effects of degree of deterioration or damage, provide more realistic and consistent safety-assessment and capacity rating.

  • PDF

Prediction of Heat and Water Distribution in Concrete due to Changes in Temperature and Humidity (온도와 습도의 변화에 따른 콘크리트 내부의 열, 수분 분포 예측)

  • Park, Dong-Cheon;Lee, Jun-Hae
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.31-32
    • /
    • 2020
  • Concrete changes its internal moisture distribution depending on the external environment, and changes in the condition of the material's interior over time affect the performance of the concrete. These effects are closely related to the long-term behavior and durability of concrete, and the degree of deterioration varies from climate to climate in each region. In this study, we use actual climate data from each region with distinct climates. A multi-physical analysis based on the method was conducted to predict the difference and degree of deterioration rate by climate.

  • PDF

A Study on the Deterioration Diagnosis of 600V Shielded Twisted Pair Control/Measurement Cable using Resonance Frequency (케이블 공진을 이용한 600V 제어/계측용 꼬임쌍선 차폐 케이블의 열화상태 진단에 대한 연구)

  • Shin, JaeYoung;Kim, KwangHo;Nah, WanSoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.12
    • /
    • pp.1768-1775
    • /
    • 2015
  • Recent major domestic facilities, such as nuclear power plants, many control cables are installed and are degraded by long-term use, but research on deterioration diagnosis is lacking. In the event of a fault in the cable due to deterioration can be developed into a major accident such as the main plant is stopped, so the deterioration diagnostic techniques of high reliability for the cable is required. In this paper, proposes a methodology using a cable resonance that can effectively diagnose the deterioration of the cable. Prior to the test, we developed a setup for stable measuring the characteristics of the cable and it verified the suitable of the measurement set-up in terms of interactivity and reliability, also measured S-parameters applying verified measurement set-up to the cables that deterioration degree is different. Then, we had amplified the difference in resonance frequency between the healthy state and the deteriorated state using connection in a series of measured S-parameters. In a result from the method, we have verified that the more deteriorate the cables is, the more decrease the resonance frequency is. Measured results are justified by inducing the resonance frequency calculation of the cable from the S- parameters represented by the hyperbolic function formula. VNA(Vector Network Analyzer) for S-parameter measurements used in this study is Agilent E5061B and shielded twisted-pair cables was used for deterioration diagnostic test.

Analysis of Physical Characteristics and Deterioration Type of Trail in National Parks (국립공원 탐방로의 물리적 특성 및 훼손유형 분석 - 6개 국립공원을 대상으로 -)

  • Jeong, Won-Ok;Ma, Ho-Seop;Kang, Won-Seok
    • Journal of agriculture & life science
    • /
    • v.46 no.1
    • /
    • pp.17-27
    • /
    • 2012
  • The purpose of this study is to analyze the trail deterioration condition and to obtain the information for the desirable maintenance and restoration of trail in national parks. The results obtained from this study were summarized as follows; The physical characteristics of trail were surveyed at the total 778 point for 204.5 km in length. As a result, the average degree of trail was $14.6^{\circ}$, average trail width was 1.5m and average bared trail width was 1.1 m. Major deterioration types of trail were trail deepen (37%), root exposed, widen, diverged, rock exposed and slope erosion in order of frequency. Deterioration class of trail were that non-deterioration was 165.34 km (80.9%), heavy class was 9.08 km, middle class was 12.69 km and light class was 17.39 km and the deterioration rate was 19.1%.

A Study on the Direction of Residential Environment Improvement through the Residents Survey in Long-term Public Rental Housing (장기공공임대주택 주민의식조사를 통한 주거환경개선방향 설정연구)

  • Lee, Ji-Eun;Yoon, Young-Ho;Kim, Yu-Jeong
    • Land and Housing Review
    • /
    • v.4 no.1
    • /
    • pp.65-75
    • /
    • 2013
  • The residential environment of old and deteriorated public rental housing has been improved for preventing house deterioration through the facility improvement projects during the recent three years. The purpose of this study is to check the effect of applied facility improvement projects through a survey to residents on the significance degree of improving the residential environment and the satisfaction degree of current residential environment. Moreover, this study aims to draw out the direction of the residential environment improvement. At first, for this purpose, a survey to the residents of old and deteriorated public rental housing in the country was conducted. In addition, the mean value analysis on the satisfaction degree and significance degree was done, and the factor analysis was conducted for the distinction between types of items. As a result, 29 items of residential public space for residential environment improvement were divided into six factors and 28 items for generation of each units were divided into four factors. The mean value of the satisfaction degree and significance degree was compared. In conclusion, the design direction of environment improvement projects in the future was suggested with the result of the survey.

Assessment of Impact Rating Class and Deterioration Type on the Trails in Mt. Namsan District, Gyeongju National Park (경주국립공원 남산 지구의 탐방로 훼손 유형 및 환경피해도 평가)

  • Heo, Sang-Hyun;You, Ju-Han
    • Journal of Environmental Science International
    • /
    • v.24 no.11
    • /
    • pp.1431-1442
    • /
    • 2015
  • This study was carried out to systematically maintain and manage the trails by assessing the physical characteristics, the types of deterioration and impact rating class of trails located in Mt. Nam District of the Gyeongju National Park. The major trails followed 6 routes including Sambulsa-Geumobong(A), Yongjangsaji-Geumobong(B), Yongjanggol-Yiyoungjae-Gowibong(C), Cheonusa-Gowibong(D), Sangseojang-Forest road(E) and Tongiljeon-Forest road(F). The routes length of A was 2.2 km, 2.7 km of B, 3.4 km of C, 1.3 km of D, 2.0 km of E and 1.0 km of F. In the physical characteristics, A was the widest and F was the narrowest in the width and bared width of trail. In depth of erosion, B was the deepest and E was the shallowest. D was the steepest and E was the gentlest in the slope. In the results of analysing the types of deterioration, A were 13 types, 11 types of B, C and D, 10 types of E and 6 types of F. The times of appearance of deterioration types in A were 86 times, 75 times of B, 105 times of C, 48 times of D, 47 times of E and 13 times of F. In case of the impact rating class, trail erosion was II degree, I degree of trail expansion, root exposure, trail divergence and rock exposure.

Application of Judgement Criteria to Measure Deterioration and to Judge Insulation Resistance in High-Power Live XLPE Cables (고전력 활선 XLPE 케이블의 열화를 측정하기 위한 판정기준의 적용 및 절연상태 판정)

  • Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.2
    • /
    • pp.239-244
    • /
    • 2017
  • The demand for electric power is increasing every year. All facilities operating at power stations and all facilities used in transmitting high volumes of electric power are therefore expected to operate with a high degree of reliability. 6.6 kV XLPE 100 SQ 1C cables are used to deliver high levels of generated electric power. Depending on the method of manufacture, installation environment, and usage conditions, the deterioration processes of power cables start from the instant of operation. Cable junctions may break down in three years from the start of operation due to manufacturing or construction defects. We have invented the first device in Korea to monitor the status of live cables and installed these at Korea Western Power Co., Ltd.. We have set the criteria to determine deterioration status and specified the degree of deterioration at which one should replace the cables. In this paper, we present the effect of insulation layer and sheath on the insulation resistance status in cables.

Deterioration Mechanism of Paper according to Sizing and Beating(I)-Influences of Sizing- (사이징과 고해에 따른 종이의 열화기구(제1보)- 사이징의 영향 -)

  • 김봉용
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.30 no.2
    • /
    • pp.24-29
    • /
    • 1998
  • This study was carried out in order to elucidate the deterioration mechanism of paper according to various sizing chemicals. No additive paper and four kinds of papers containing rosin-alum, alum only, alkylketene dimer(AKD)-cation polymer and cation polymer only were treated by UV light to study changes of water-resistant, optical and mechanical properties from the view points of natural deterioration of paper. Since rosin chemicals have UV absorption at the relatively long wavelength region, rosins are degraded to form hydrophilic groups such as carboxylic acid from their double bonds by UV treatments. These phenomena caused the decreasing of sizing degree and wetting time in case of rosin-sized paper, while the UV treatments brought about the slight increase of wetting time in rosin-free papers such as no additive, alum and kymene only paper owing to the auto-sizing effect. Optical properties were primarily influenced by sizing chemicals. Rosin-sized paper showed lower brightness after UV and near UV treatment because of its UV instability.

  • PDF