Development of Rating System for Highway Bridges (도로교 내하급수 판정시스템 개발)

  • Cho, Hyo Nam;Chang, Dong Il;Lee, Hee Hyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.11 no.4
    • /
    • pp.9-15
    • /
    • 1991
  • This study is directed for the development of rational rating models for realistic safety assessment and the computer rating system for highway bridges. For this purpose, the conventional rating system is considerably improved in appropriate way, and a rational rating system based on the reliabilty method is proposed to estimate safety of deteriorated bridges by using only the visual inspection data or the statistical data available. In addition. the rating system which can assess the realistic allowable passing tonnage of military vehicles in case of the military operations is also presented. From this study, it is known that the presented rating system and the computer program BRS(Bridge Rating System) provide an effective tool which can handle the degree of deterioration and various uncertainities of the bridge systematically. so it can be used widely for assessment of safety and load carrying capacity of existing deteriorated or damaged bridges.

  • PDF

Mechanical and Electrical Properties of Aluminum Wires of ACSR Conductors due to Forest Fire (산불에 노출된 강심알루미늄연선 송전선 알루미늄 선재의 기계적 및 전기적 특성 거동)

  • Lee, Won-Kyo;Lee, Jung-Won;Kim, Byung-Geol
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.9
    • /
    • pp.730-735
    • /
    • 2010
  • Forest fire can cause a serious damage to overhead conductors. Therefore, detailed investigation on the changes of mechanical and electrical properties of damaged conductors should be carried out to understand the effect of forest fires on conductors. This is of critical importance in maintaining transmission line safely. This paper examines the changes of mechanical and electrical properties of flame exposed conductor. Tensile strength (TS) decreased according to increase of forest fire temperature and conductivity changed according to forest fire temperature. Specimens were aluminum conductors of aluminium conductor steel reinforced (ACSR) 410, 240, 480 $mm^2$. In this paper, the electrical and mechanical characteristics of forest fires exposed overhead conductors depending on the diameter of aluminum conductors are presented. It was possible to estimate the degree of deterioration caused by forest fires. The detailed results are given in the paper.

Longest Follow up after Closed Mitral Commisurotomy in Korea: case report (승모판 교련절개술을 받은 한국최초의 승모판협착증 [증례 보고])

  • 유회성
    • Journal of Chest Surgery
    • /
    • v.12 no.4
    • /
    • pp.361-364
    • /
    • 1979
  • The first Mitral Commissurotomy was performed for tight mitral stenosis on March 1957. The patient was at that time 22-year-old male, student. The longest follow 9p for 22 years and 8 months has been obtained. During the follow up period, late deterioration due to restenosis developed 4 years after initial good result and reoperation was succeeded by transventricular Mitral Valvotomy with Tubb`s ilator on April 1964. The possible cause of restenosis was attributed to recurrent rheumatic activity. After more than 13 years long-good life following 2nd operation, Endocarditis such as episode of high fever & chill intermittently followed by mild fever and night sweat, I t. tibial artery embolization and rupture of aortic cusp. At present, patient complained of no subjective symptom, enjoying ordinary life {NYHA II]. Blood pressure has been 110/50-60 mmHg, trivial diastolic murmur at apex and moderate degree of mechanical murmur on diastole at Erb`s rea. Neither signs of RVH for mitral stenosis nor sign of LVH. ST-T change for aortic regurgitation appeared yet during last 2 yrs. The patient`s are for prevention of Rheumatic activity and development of endocarditis is important for obtaining the better long-term result.

  • PDF

A Study on the Economic Repair Pattern of the Building Components in the Apartment Housing (공동주택 구성재의 경제적 수선형태 설정 연구)

  • Lee, Kang-Hee;Chae, Chang-U
    • Journal of the Korean housing association
    • /
    • v.17 no.5
    • /
    • pp.87-95
    • /
    • 2006
  • Building components have been deteriorated by various factors such as location, a building type, a surrounding environment and so on. In addition, each component has a peculiar characteristics, compared with other components in properties of matter an used part. Building components would be required to maintain its function and performance to provide the resident with a decent living condition. It is important to decide the repair time, scope and a required cost in repair plan, considering the each component's characteristics. In this parer, it aimed at providing the economic repair pattern to analyze the relation of the time-elapse and the cumulative repair cost in the apartment housing using 3rd quadratic function. Results of the study are as follows: First, the shape of the function for the economic repair is classified into two type. One is the continuous increase type of the cumulative cost which properly means the iterative repair type after built. The other is that the function has the maximum state at a point which means one-repair after its repair would be delayed to a scheduled time. Second, the iterative repair pattern would include window, roof proof, lighting and water supply pipe. The other repair pattern would include the paintings, heating pipe and sign board.

A Study on Activation methods of Traditional Market in Jinju City -Focused on Joongang and Seobu Market- (진주시 전통시장 개선방안 연구 -중앙시장과 서부시장을 중심으로-)

  • Kang, Seok-Jin
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.17 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • The purpose of this study is to consider activation methods of traditional markets in Jinju city through questionnaire and field survey. Research framework is summarized into two categories: physical environment and operation program. The results are as follows: 1) the gross profit on sales has been decreased continuously and the main causes of that have been recognized as insufficiency of parking lots and convenient facilities and deterioration of environment in spite of facilities modernization project; 2) consumers visited a traditional market because of proper price and reliance on goods, etc. However, they were not satisfied with the physical environment such as parking lots and resting spaces and the operation program such as cultural event and performance. In conclusion it was thought that activation methods of traditional market would be related to the improvement plan in the physical aspect such as parking lots, walkway, convenient and crime prevention facilities and in the operation program aspect such as cultural event, marketing, management consulting, information infrastructure, and delivery system.

The Survey on Residents' Opinion of the Stronghold Diffusion Residential Environment Improvement Plan in San-Jun (산전 지역의 거점 확산형 주거환경개선사업에 대한 주민의견 조사)

  • Kim, Sun-Joong;Jang, Hui-Jin
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.04a
    • /
    • pp.332-337
    • /
    • 2009
  • The stronghold diffusion style method is resident participation style residential environment improvement plan that first of all, the general public constructs base facilities which the temporary occupancy public housings, commonness use facilities, roads, etc. And then with using the public housing of the stronghold sector, the resident oneself improves the house with independence or commonness. As a result induction of the voluntary participation of economic situation and the resident where the improvement will is reflected and introduction of versatile maintenance method through stronghold development with participation of the general public, this study tries to present the residential improvement method of diffusion style. San-Jun was selected in the subject of investigation area in stronghold diffusion style residential environmental improvement plan area. Investigation contents population register quality and quality of present house, the degree which is a house environmental improvement plan, about residential improvement the fact etc. Because unsatisfactorily in compliance with the deterioration and spatial narrow of the house, The above of half is an improvement intention. Hereafter residential improvement, According to the condition which is economic, residential improvement will change. The plan will be able to augment the economic enemy capability of the resident should grope and the residents oneself creates the environment will be able to improve the house. Also with creating, activating a resident organization, through autonomous decision-making process, the residential improvement could be advanced continuously.

  • PDF

Analysis on the Aging Process of ac-Plasma Display Panel

  • Park, Min-Soo;Park, Deok-Hai;Kim, Bo-Hyun;Ryu, Byung-Gil;Kim, Sung-Tae;Seo, Gi-Weon;Kim, Dae-Young;Park, Seung-Tea;Kim, Jong-Bin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.126-129
    • /
    • 2006
  • AC-plasma display panels were examined before and after the aging process to analyze the effect of the aging process. The gas analysis was done to detect the impurity gases out of the MgO film and phosphor by a residual gas analyzer. There were no differences found in the components. The MgO film was analyzed to find out the effect of an ion bombardment due to discharge. The surface roughness of the MgO film was different from regional groups due to the different degree of ion bombardments. XPS analysis showed that the 8 hour aging process was not sufficient to remove $Mg(OH)_2$ and $MgCO_3$ existed on the MgO surface. Photoluminescence measurement showed the small deterioration of blue and green phosphor.

  • PDF

The Electric Field Distribution Characteristic Of Outdoor ECT Using the Preventive Diagnostic Sensor (예방진단센서가 내장된 옥외용 ECT의 전계분포특성)

  • Lee, Han-Joo;Cho, Sung-Hoon;Jung, Eui-Hwan;Yoon, Jae-Hoon;Lim, Kee-Joo;Kang, Sung-Hwa
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.03b
    • /
    • pp.27-27
    • /
    • 2010
  • The exact partial discharge pulse should be measured in order to estimate the discharge source in the solid insulation and diagnose the degree of deterioration. Partial discharges generated in the insulation occur in the internal voids or at the edge of the insulation, have unique characteristics following the type and location. When external voltage is applied, Partial discharges occurred in the restrictively presented voids increase the quantity of electrical charge at the discharge onset voltage. The discharge characteristics have remained constant as space is filled by the impurity such as a compound of gases accompanied with discharge. In this study, How to design the insulation about the problems of the built-in diagnostics in the transformer is discussed by the interpretation of electric field.

  • PDF

Evaluation on Basic Properties of Crushed Sand Mortar in Freezing-Thawing and Sulfate Attack (동결융해와 황산염의 복합작용을 받는 부순모래 모르타르의 기초 특성 평가)

  • Kim, Myeong-Sik;Baek, Dong-Il;Choi, Kang-Seok
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.5
    • /
    • pp.54-60
    • /
    • 2009
  • Exposed to various environments, concrete confronts degradation by a lot of physical and chemical reaction. Though so many experiments and theorizations on the single condition of concrete degradation have been carried out by constant studies, the truth for now is that there are few studies on the compound phenomenon of degradation related with marine environments. Accordingly, this study measured the degree of degradation in the change of external shape, the change of unit weight and compressive strength, ultrasonic velocity test, and the change of length, etc. after exposing the specimen of cement mortar to the environment between 0 cycle and the maximum of 300 cycles under the condition of aquatic curing, freezing and thawing, and compound degradation, using mineral admixture effective for concrete degradation as a binder. The result indicated that the case of adding mineral admixture showed greater resistance than that of using OPC only, and specifically, the specimen with the additive of slag powder and three component system showed very excellent resistance to freezing and thawing, and compound degradation.

Vehicle Instrument Cluster Layout Differentiation for Elderly Drivers

  • Kim, Sang-Hwan
    • Journal of the Ergonomics Society of Korea
    • /
    • v.35 no.5
    • /
    • pp.449-464
    • /
    • 2016
  • Objective: The objective of this study is to identify essential requirements of the instrument cluster's features and layout for elderly drivers through interview and paper prototyping. Background: Recent updates implemented in passenger vehicles require more complex information to be processed by drivers. Concurrently, a large portion of the US population, the baby boomer generation has aged, causing their physical and cognitive abilities to deter. Thus it is crucial that new methods be implemented into vehicle design in order to accommodate for the deterioration of mental and physical abilities. Method: Forty elderly drivers and twenty young drivers participated in this study. The test included three sessions including: 1) location value assessment to identify the priority of areas within the instrument cluster; 2) component value assessment to capture rankings of the degree of importance and frequency of use for possible instrument cluster components; and 3) paper prototyping to collect self-designed cluster with selection of designs for each component and location of features from each participant. Results: Results revealed differences in the area priority of the instrument cluster as well as the shape and location of component features for age and gender groups. Conclusion: The study provided insights on instrument cluster layout guidelines by proving elderly driver's mental model and preferred cluster design configurations to improve driving safety. Application: LCD-based vehicle instrument cluster design, with an adaptable feature configuration for cluster components and layouts.