• 제목/요약/키워드: detector mount

검색결과 11건 처리시간 0.026초

Detector Mount Design for IGRINS

  • Oh, Jae Sok;Park, Chan;Cha, Sang-Mok;Yuk, In-Soo;Park, Kwijong;Kim, Kang-Min;Chun, Moo-Young;Ko, Kyeongyeon;Oh, Heeyoung;Jeong, Ueejeong;Nah, Jakyoung;Lee, Hanshin;Jaffe, Daniel T.
    • Journal of Astronomy and Space Sciences
    • /
    • 제31권2호
    • /
    • pp.177-186
    • /
    • 2014
  • The Immersion Grating Infrared Spectrometer (IGRINS) is a near-infrared wide-band high-resolution spectrograph jointly developed by the Korea Astronomy and Space Science Institute and the University of Texas at Austin. IGRINS employs three HAWAII-2RG Focal Plane Array (H2RG FPA) detectors. We present the design and fabrication of the detector mount for the H2RG detector. The detector mount consists of a detector housing, an ASIC housing, a Field Flattener Lens (FFL) mount, and a support base frame. The detector and the ASIC housing should be kept at 65 K and the support base frame at 130 K. Therefore they are thermally isolated by the support made of GFRP material. The detector mount is designed so that it has features of fine adjusting the position of the detector surface in the optical axis and of fine adjusting yaw and pitch angles in order to utilize as an optical system alignment compensator. We optimized the structural stability and thermal characteristics of the mount design using computer-aided 3D modeling and finite element analysis. Based on the structural and thermal analysis, the designed detector mount meets an optical stability tolerance and system thermal requirements. Actual detector mount fabricated based on the design has been installed into the IGRINS cryostat and successfully passed a vacuum test and a cold test.

Mechanical design of mounts for IGRINS focal plane array

  • Oh, Jae Sok;Park, Chan;Cha, Sang-Mok;Yuk, In-Soo;Park, Kwijong;Kim, Kang-Min;Chun, Moo-Young;Ko, Kyeongyeon;Oh, Heeyoung;Jeong, Ueejeong;Nah, Jakyuong;Lee, Hanshin;Pavel, Michael;Jaffe, Daniel T.
    • 천문학회보
    • /
    • 제39권1호
    • /
    • pp.53.2-53.2
    • /
    • 2014
  • IGRINS, the Immersion GRating INfrared Spectrometer, is a near-infrared wide-band high-resolution spectrograph jointly developed by the Korea Astronomy and Space Science Institute and the University of Texas at Austin. IGRINS employs three HAWAII-2RG focal plane array (FPA) detectors. The mechanical mounts for these detectors serves a critical function in the overall instrument design: Optically, they permit the only positional compensation in the otherwise "build to print" design. Thermally, they permit setting and control of the detector operating temperature independently of the cryostat bench. We present the design and fabrication of the mechanical mount as a single module. The detector mount includes the array housing, a housing for the SIDECAR ASIC, a field flattener lens holder, and a support base. The detector and ASIC housing will be kept at 65 K and the support base at 130 K. G10 supports thermally isolate the detector and ASIC housing from the support base. The field flattening lens holder attaches directly to the FPA array housing and holds the lens with a six-point kinematic mount. Fine adjustment features permit changes in axial position and in yaw and pitch angles. We optimized the structural stability and thermal characteristics of the mount design using computer-aided 3D modeling and finite element analysis. Based on the computer simulation, the designed detector mount meets the optical and thermal requirements very well.

  • PDF

우주전파관측용 음향광학 전파분광기의 제작 (Manufacture of an Acousto-Optical Spectrometer for Radio Astronomical Observations)

  • 임인성;최재현;오승엽
    • 한국전자파학회논문지
    • /
    • 제8권1호
    • /
    • pp.1-12
    • /
    • 1997
  • 우주전파신호 분석을 위한 음향광학 전파분광기를 제작하였다 이 시스템은 우주로부터 수신된 미약한 전파신 호를 분석하는 신호처리 장치로 레이저 공진기 광학계. 광편향소자와 CCD로 구성된다. 이 시스템은 전파 시호를 분석하는 기존의 필터뱅크, 자기상관 분광기와는 달리 레이저와 광학계를 사용하여 빔을 유도하고 전파신호를 광편향소자에 의해 초음파로 변환하여 레이저빔을 회절시키는 새로운 방식의 전파 분광기이다. 광원으로는 He-Ne 레이저를 사용하였으며, 1 GHz에서 2 GHz까지의 대역폭을 갖는 광대역 GaP 광편향소자를 사용였다 . 또한 광신호 검출을 위해 2,048 채널의 CCD를 제작하였다 본 연구에서는 음향광학효과에 대한 이론적 배을 설명하고 레이저 공진기를 이용한 광학계의 설계, 광학마운트의 제작, CCD Driver, 인터페이스 제작과 이를 이용한 전파 신호의 측정에 대해 논의하였다. 전파선호의 측정결과 0차광이 1차광을 간섭시켜 2,048채널 중 I,000채널의 대역폭을 갖는 분팡가 성능을 갖게 되었다.

  • PDF

방사선 분포 모니터링 시스템 (Radiation level distribution monitoring system)

  • 최영수;박순용;이종민
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.828-831
    • /
    • 1996
  • Radiation monitoring system is needed at nuclear power plant and nuclear facility. Manual survey techniques are commonly used, but they are time consuming and somewhat inaccurate. Automatic radiation surveys are very important because it provides significant savings in men-rem and wages. Unmanned, remote automatic radiation measurement system should be small and light-weighted in order to mount on robotic system. The system we have developed consists of detection parts, signal processing part, interface, and software part. Position information is provided by using of a collimator. The measurement process is achieved by the scanning of detector and image processing techniques are used to display radiation levels. We designed collimators, detectors, signal processing circuit, and constructed prototype system. The goal of this system is the mapping of camera image and radiation level distribution.

  • PDF

Monte Carlo 방법을 이용한 바나듐 자발 중성자계측기 초기 민감도 계산 (Calculation of Initial Sensitivity for Vanadium Self-Powered Neutron Detector (SPND) using Monte Carlo Method)

  • 차균호;박영우
    • 센서학회지
    • /
    • 제25권3호
    • /
    • pp.229-234
    • /
    • 2016
  • Self-powered neutron detector (SPND) is being widely used to monitor the reactor core of the nuclear power plants. The SPND contains a neutron-sensitive metallic emitter surrounded by a ceramic insulator. Currently, the vanadium (V) SPND has been being developed to be used in OPR1000 nuclear power plants. Some Monte Carlo simulations were accomplished to calculate the initial sensitivity of vanadium emitter material and alumina insulator with a cylindrical geometry. An MCNP code was used to simulate some factors (neutron self-shielding factor and beta escape probability from the emitter) and space charge effect of an insulator necessary to calculate the sensitivity of vanadium detector. The simulation results were compared with some theoretical and experimental values. The method presented here can be used to analyze the optimum design of the vanadium SPND and contribute to the development of TMI (Top-mount In-core Instrumentation) which might be used in the SMART and SMR.

중적외선 감지용 초점면 배열 HgCdTe의 신호 취득 회로 설계 및 열영상 구현 (ROIC Design of HgCdTe FPA for MWIR detection and Implementation of Thermal Image)

  • 김병혁;이희철;김충기
    • 전자공학회논문지SC
    • /
    • 제37권3호
    • /
    • pp.63-71
    • /
    • 2000
  • 모든 물체에서 방출되는 적외선을 감지하여 영상신호로 만들어 주는 적외선 감지 칩은 보편적으로 적외선감지 소자와 신호 취득 회로가 각기 다른 칩으로 제작되어 하이브리드 본딩 기법을 통해 만들어 진다. 본 논문에서는 신호 취득 회로의 설계 과정과 시뮬레이션 결과를 보여 주며, 실제 제작 결과, 6V의 인가 전압에서 설계 사양에 만족하는 동작 특성을 보임을 확인하였다. 제작된 신호 취득 회로를 이용하여 적외선 감지칩을 제작하고 이를 자체 제작한 열영상 시스템에 장착하여 열영상을 구현해 보았다. 얻어진 열영상은 고온과 상온의 물체에 대해서 인식이 가능한 수준이었으며, 열영상 시스템의 잡음 특성을 좀 더 개선할 경우 더나은 열영상을 얻을 수 있으리라 기대한다.

  • PDF

방사선치료 장치 및 관련시설에서의 산란 중성자에 관한 연구 (A Study on the Neutron in Radiation Treatment System and Related Facility)

  • 김대섭;김정만;이희석;임라승;김유현
    • 대한방사선치료학회지
    • /
    • 제17권2호
    • /
    • pp.141-145
    • /
    • 2005
  • 목 적 : 일반적으로 10 MV이상의 광자선에서 산란 중성자를 발생시키는 것으로 알려져 있다. 세관에 설치된 컨테이너 검색장치는 9 MV 이하였음에도 중성자가 누출되었다. 본 연구에서 의료기관에 설치된 방사선 치료기에서 산란 방출되는 중성자의 공간적인 측정을 통해 결과를 분석하고 평가하고자 한다. 대상 및 방법 : 본 연구의 방사선 발생장치는 의료용 선형가속기(linear accelerator, linac: Varian, Clinac 1800, USA)를 사용하였다. 중성자 측정용 검출기는 중성자가 발생하면 기포(bubble)이 생기는 Bubble 검출기(Bubble detector, BDPND type, BTI, Canada)를 사용하였다. 의료용 선형가속기 주변에 Bubble 검출기를 isocenter로부터 30 cm, 50 cm, 120 cm의 각각 3가지 거리별로 isocenter 상하 방향 네 곳에 위치시켜 측정하였다. 주변 구조물의 영향을 살펴보기 위해 Wedge와 Mount를 장착 후 50 cm 거리에서 각각 8방향에서 측정하였다. 광자선원부터 isocenter 까지의 거리(SAD: source-axis-distance)를 100 cm로 기준을 정하고 조사면의 크기(field size)는 $15{\times}15cm^2$로 정하였다. 방사선은 20 MU를 조사하여 Bubble 검출기에 발생한 기포수를 측정하며 mrem값으로 계산하였다. 결 과 : Isocenter부터 거리가 30 cm와 50 cm 떨어진 곳의 각각 8개 측정 지점 중에서는 모두 5번 위치(Gantry 우측 아래지점)에서 측정된 산란중성자의 양이 같은 거리라도 가장 높게 측정되었다. Bubble 검출기가 Isocenter부터 120 cm 떨어진 경우와 wedge를 장착한 경우는 7번 위치(Couch 우측 아래지점), mount 탈착한 경우는 2번 위치(Gantry 왼쪽 윗지점)에서 산란 중성자가 가장 높게 측정되었다. 결 론 : 산란중성자의 측정에서 직선상 같은 거리에 있는 곳이라도, 실제 측정한 결과 값에 따르면 서로 상이한 값을 보였다. 주변 구조물도 산란 중성자에 영향을 미치며, 직선상은 같은 거리라도 각각의 지점에서 다른 값을 보였다. 따라서, 산란중성자의 거리에 따른 영향은 단순히 직선으로의 거리뿐 아니라 방향과 주변 구조물에 대한 영향까지 고려하며 공간적인 측정과 평가가 필요하다.

  • PDF

디지털 유방촬영장비에 관한 공간선량율 평가 (The Evaluation of Space Dose Distribution for Digital Mammography Equipment)

  • 정홍문;정재은;현혜진;원도연
    • 한국방사선학회논문지
    • /
    • 제9권1호
    • /
    • pp.61-65
    • /
    • 2015
  • 유방촬영장비는 여성의 조기 유방의 병변을 진단하기 위하여 필수적으로 사용되는 장비이다. 계속적인 디지털 유방촬영장치가 보급되어짐에 따라 현재에는 대부분의 의료기관에서 디지털 유방촬영장치를 사용하고 있다. 하지만 이러한 디지털장비인 CR 또는 DR 유방촬영술의 무분별한 사용으로 여성 환자의 평균유효선량이 증가되고 있다. 이번 연구는 여성환자에게 사용되는 디지털 유방촬영장비의 공간선량율을 평가하여 방사선유효선량 과다 피폭으로 인하여 발생할 수 있는 방사선 2차 피해을 인식시키고자 하였으며, 더 나아가 디지털 유방촬영장치에서 발생되는 공간선량율 측정함으로써 환자에게 직접 촬영을 하는 방사선사 안전의식을 인식시키고자 한다. 결론적으로 디지털 유방촬영장비의 공간선량은 촬영장비를 기준으로 수평으로 높은 수치를 나타내었다. 이러한 결과를 고려한다면 디지털 유방촬영장비의 설치시에 수평 방향을 피하여 방사선사의 조작위치를 변경하거나 디지털 유방촬영 장비로부터 수평으로 되는 부위에 납유리차폐의 보완이 이루어져야 할 것이다.

높이 자동제어가 가능한 차량 장착형 지뢰탐지장치에 대한 연구 (A Study on Mine Detection System with Automatic Height Control)

  • 강신천;정호영;정대연;성기열;김도종;김지웅
    • 한국군사과학기술학회지
    • /
    • 제20권4호
    • /
    • pp.558-565
    • /
    • 2017
  • The vehicle-mounted mine detection system with large detection sensor modules can search wide areas with a fast detection speed. To mount the heavy mine detectors on a manned or unmanned vehicle, it is necessary to design the detector driving mechanism and control system based on the considerations driven from the characteristic analysis and the operation requirements of the detection system. Furthermore, while operating the mine detector mounted on a mobile vehicle, it is significant to keep the height from the ground to sensors within a certain distance in order to get a qualified detection performance. As the mine detection sensor, we used ground penetrating radar widely used to geotechnical exploration, mine detection and etc. In this paper, we introduce a driving mechanism through analyzing the characteristics of the vehicle-mounted mine detection system. We also suggest a method to automatically control the distance between the ground and GPR by utilizing the GPR output values, used to detect mines at the same time.

Gamma Camera에 있어 측면 선란선의 영향에 대한 평가 (The Evaluation of Lateral Scatter Ray of Gamma Camera)

  • 김재일;이은별;조성욱;노경운;강건욱
    • 핵의학기술
    • /
    • 제22권1호
    • /
    • pp.46-50
    • /
    • 2018
  • 검출기 외부에 강한 선원은 collimator와 상호 작용으로 산란선이 만들어지게 되는데, 그 산란선이 영상에 얼마나 영향을 주는지 평가하고자 한다. SKY LITE를 사용하여, phantom study의 경우, $^{99m}Tc$ 1.11 GBq를 점선원으로 만들어 검출기 주변을 $10^{\circ}$ 간격으로 돌아가면서 측정하여 각 각도에서의 산란선의 정도를 계수율과 스펙트럼으로 분석을 하였다. Patient study의 경우, 3-phase bone scan을 하는 환자를 대상으로, blood flow와 blood pool 영상을 획득하면서 산란선의 양과 스펙트럼을 분석하였다. 추가로 blood pool 검사 시, 환자의 손위에 납가운을 올려놓고 영상을 획득하였고, 환자의 몸에 납가운을 입히고 영상을 획득하여 각 영상에서의 산란선과 스펙트럼을 비교, 평가하였다. 그 결과, phantom study의 경우, 후방에서는 산란선의 없었지만, 측면부터 전방 $50^{\circ}$ 까지는 산란선이 많이 검출 되었다. patient study의 경우 blood flow 영상과 blood pool 영상에서 환자 몸에서 나온 감마선으로 인해 생긴 산란선이 입사됨을 알 수 있었다. 그리고 납가운은 손 위를 차폐하는것 보다, 환자 몸을 차폐 하는 것이 산란선이 많이 줄었다. 그러므로 외부에 강한 선원이 존재하고, hand blood flow, blood pool 검사처럼 계수 자체가 낮을 검사를 할 경우, 몸에서 나오는 선원 자체를 차폐하는 것이 산란선을 줄이는데 보다 효과가 있으며, 영상에서도 배후 방사선을 줄이는데 효과가 있음을 알 수 있었다.