• Title/Summary/Keyword: detector combination

Search Result 118, Processing Time 0.024 seconds

Exploitation of Dual-polarimetric Index of Sentinel-1 SAR Data in Vessel Detection Utilizing Machine Learning (이중 편파 Sentinel-1 SAR 영상의 편파 지표를 활용한 인공지능 기반 선박 탐지)

  • Song, Juyoung;Kim, Duk-jin;Kim, Junwoo;Li, Chenglei
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.5_2
    • /
    • pp.737-746
    • /
    • 2022
  • Utilizing weather independent SAR images along with machine learning based object detector is effective in robust vessel monitoring. While conventional SAR images often applied amplitude data from Single Look Complex, exploitation of polarimetric parameters acquired from multiple polarimetric SAR images was yet to be implemented to vessel detection utilizing machine learning. Hence, this study used four polarimetric parameters (H, p1, DoP, DPRVI) retrieved from eigen-decomposition and two backscattering coefficients (γ0, VV, γ0, VH) from radiometric calibration; six bands in total were respectively exploited from 52 Sentinel-1 SAR images, accompanied by vessel training data extracted from AIS information which corresponds to acquisition time span of the SAR image. Evaluating different cases of combination, the use of polarimetric indexes along with amplitude values derived enhanced vessel detection performances than that of utilizing amplitude values exclusively.

Commissionning of Dynamic Wedge Field Using Conventional Dosimetric Tools (선량 중첩 방식을 이용한 동적 배기 조사면의 특성 연구)

  • Yi Byong Yong;Nha Sang Kyun;Choi Eun Kyung;Kim Jong Hoon;Chang Hyesook;Kim Mi Hwa
    • Radiation Oncology Journal
    • /
    • v.15 no.1
    • /
    • pp.71-78
    • /
    • 1997
  • Purpose : To collect beam data for dynamic wedge fields using conventional measurement tools without the multi-detector system, such as the linear diode detectors or ionization chambers. Materials and Methods : The accelerator CL 2100 C/D has two photon energies of 6MV and 15MV with dynamic wedge an91es of 15o, 30o, 45o and 60o. Wedge transmission factors, percentage depth doses(PDD's) and dose Profiles were measured. The measurements for wedge transmission factors are performed for field sizes ranging from $4\times4cm^2\;to\;20\times20cm^2$ in 1-2cm steps. Various rectangular field sizes are also measured for each photon energy of 6MV and 15MV, with the combination of each dynamic wedge angle of 15o 30o. 45o and 60o. These factors are compared to the calculated wedge factors using STT(Segmented Treatment Table) value. PDD's are measured with the film and the chamber in water Phantom for fixed square field. Converting parameters for film data to chamber data could be obtained from this procedure. The PDD's for dynamic wedged fields could be obtained from film dosimetry by using the converting parameters without using ionization chamber. Dose profiles are obtained from interpolation and STT weighted superposition of data through selected asymmetric static field measurement using ionization chamber. Results : The measured values of wedge transmission factors show good agreement to the calculated values The wedge factors of rectangular fields for constant V-field were equal to those of square fields The differences between open fields' PDDs and those from dynamic fields are insignificant. Dose profiles from superposition method showed acceptable range of accuracy(maximum 2% error) when we compare to those from film dosimetry. Conclusion : The results from this superposition method showed that commissionning of dynamic wedge could be done with conventional dosimetric tools such as Point detector system and film dosimetry winthin maximum 2% error range of accuracy.

  • PDF

Volatile Flavor Compounds Identified from the Sauces Made with Waste of Shrimp, Crab and Lobster (새우, 게 및 바다가재의 부산물로 만든 소스의 휘발성 향기 성분)

  • Lee, Kyeoung-Im;Cho, Ji-Eun;Ahn, Hung-Ki
    • Culinary science and hospitality research
    • /
    • v.13 no.1 s.32
    • /
    • pp.119-128
    • /
    • 2007
  • Volatile flavor compounds of sauces made from shrimps, crabs or lobsters were analyzed by the combination of canister system, gas chromatography(GC) and mass selective detector(MSD). Of 72 total volatile compounds from 4 kinds of sauces, 45 compounds were identified from shrimp sauce(SS). Ten alkanes, 5 ketones, 3 aldehydes were obtained from SS. Especially, 3-methyl-2-butanone, 2-pentanamine, isobutane, 3-methyl-2-butanol, carbon disulfide and dimethyl sulfide were predominant compounds in SS. In crab sauce(CS), there were 18 compounds identified, including 4 alcohols, 4 alkanes, 3 aldehydes, 2 ketones, acid and amine. 2-Methoxy ethanol, trimethyloxirane and 3-buten-1-ol were special volatile compounds in CC. Volatile compounds from lobster head sauce(LHS) or lobster shell sauce(LSS) were 16 or 18 kinds respectively. The major volatile compounds of LHS were formic acid, 1-propanethiol, $\beta$-pinene and allyl sulfide, and those of LSS were acids, pentane, 3-methyl-1-butanol and 2,4-dimethyl-3-pentanone. It was thought that the volatile compounds identified from sauces as well as shrimps, crabs or lobsters might come from wine, onions, bay leaves or celery used as minor ingredients.

  • PDF

Dose Measurements using Phantoms for Tube Voltage, Tube Current, Slice Thickness in MDCT (MDCT의 관전압, 관전류, 슬라이스 두께 변화에 따른 팬텀의 선량 분포 측정)

  • Lee, Chang-Lae;Jeon, Seong-Su;Nam, So-Ra;Cho, Hyo-Min;Jung, Ji-Young;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.139-143
    • /
    • 2007
  • The purpose of this study was to measure and evaluate radiation dose for MDCT parameters. Patient dose for various combination of MDCT parameters were experimentally measured, using MDCT (GE light speed plus 4 slice, USA), model 2026C electrometer (RADICAL 2026C, USA), standard Polymethylmethacrylate (PMMA) head and body CT dosimetry phantoms. In clinical situations, for a typical abdominal scan performed with MDCT at 120 kVp, 180 mAs, 20 mm collimation, and a pitch of 0.75 $CTDI_w,\;CTDI_{vol}$ were measured as 20.2 mGy, 26.9 mGy, respectively. When scan length is assumed as 271.3 mm, DLP and measured effective dose of the abdominal would be calculated as $729.1\;mGy{\cdot}cm$, 10.9 mSv, respectively.

  • PDF

Simultaneous Identification/Determination System for Sildenafil, Homosildenafil, Vardenafil and Tadalafil as Adulterants in Foods (식품중 불법함유된 발기부전치료제 성분 검출을 위한 동시분석법 연구)

  • Jang, Jae-Hee;Park, Kun-Sang;Park, Hye-Kyung;Koo, Yong-Eui;Choi, Youn-Ju;Hwang, In-Kyung;Kim, Dai-Byung
    • Journal of Food Hygiene and Safety
    • /
    • v.18 no.4
    • /
    • pp.195-201
    • /
    • 2003
  • An easily available, simultaneous identification/determination procedure for sildenafil, homosildenafil, tadalafil, vardenafil in adulterated health related foods was established by using a combination of three different analytical methods; thin layer chromatography(TLC), liquied chromatography-mass spectrometry (LC/MS) and high-performance liquied chromatography (HPLC)/photo-diode-array detector. The sample solution for TLC was applied to silica gel 60 $F_{254}$ plates with ethylacetate/acetonitrile/25%ammonia (90:10:5) as a developing solvent. Spots were located under UV radiation at 254 nm and dragendolfs reagent. Mass spectra of the compounds by LC/MS were investigated with electrospray ionization (ESI) interface, under positive ion mode. The HPLC analysis was performed on a column of capcell pack $C_{18}$ (UG120, 4.6${\times}$250mm I.D. 5 ${\mu}$m)with 0.1% sodium 1-hexansulfonate (in 0.1% phosphoric acid)/acetnitrile (73:27) as a mobile phase, and effluent was minitored with a photo-diode-applied to commercial foods, Sildenafil content was inthe range of 0.4mg/g~360.9 mg/g from 7 out of 35 samples. Homosildenafil content was in the range of 2.2 mg/g~336.0 mg/g from 7 out of 35 samples. Tadalafil content was 429.3 mg/g, 9.6 mg/500 mg from 2 out of 35 samples. The procedure described here is available for the screening of sildenafil, homosildenafil, tadalafil, vardenafil.

Examination of GC-TD sensitivity for reduced sulfur compounds in relation to temporal stability and reproducibility (환원 황화합물의 열탈착 분석기법에 대한 감도의 경시변화 및 재현성에 대한 연구)

  • Hong, One-Feel;Kim, Ki-Hyun
    • Analytical Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.24-35
    • /
    • 2010
  • To learn more about the calibration properties of reduced sulfur compounds (RSCs) by the combination of gas chromatography(GC)-pulsed flame photometric detector (PFPD) and thermal desorption method, a series of calibration experiments were conducted on the basis of both internal and external calibration approaches. For these experiments, gaseous standards of 4 RSCs ($H_2S$, $CH_3SH$, DMS, and DMDS) were prepared at two different concentration levels of both low (10, 20, 50,and 100 ppb) and high ranges (100, 200, 500, and 1000 ppb) along with $CS_2$ as an internal standard. First, the external calibration results were compared between fixed standard volume (FSV) and fixed standard concentration (FSC) method. Secondly, FSV-based calibration results were compared between external and internal calibration results. As FSV method suffers from sensitivity variations less significantly than FSC, the former is recommended to maintain the consistency in GC-TD sensitivity for RSC analysis. In addition, when the calibration data were examined in terms of RSE between external and internal calibration data, the results were not consistent enough to show improvements in internal method. Hence, diverse efforts are desirable to optimize the reproducibility in terms of GC-TD sensitivity for RSC analysis.

A Combined Hough Transform based Edge Detection and Region Growing Method for Region Extraction (영역 추출을 위한 Hough 변환 기반 에지 검출과 영역 확장을 통합한 방법)

  • N.T.B., Nguyen;Kim, Yong-Kwon;Chung, Chin-Wan;Lee, Seok-Lyong;Kim, Deok-Hwan
    • Journal of KIISE:Databases
    • /
    • v.36 no.4
    • /
    • pp.263-279
    • /
    • 2009
  • Shape features in a content-based image retrieval (CBIR) system are divided into two classes: contour-based and region-based. Contour-based shape features are simple but they are not as efficient as region-based shape features. Most systems using the region-based shape feature have to extract the region firs t. The prior works on region-based systems still have shortcomings. They are complex to implement, particularly with respect to region extraction, and do not sufficiently use the spatial relationship between regions in the distance model In this paper, a region extraction method that is the combination of an edge-based method and a region growing method is proposed to accurately extract regions inside an object. Edges inside an object are accurately detected based on the Canny edge detector and the Hough transform. And the modified Integrated Region Matching (IRM) scheme which includes the adjacency relationship of regions is also proposed. It is used to compute the distance between images for the similarity search using shape features. The experimental results show the effectiveness of our region extraction method as well as the modified IRM. In comparison with other works, it is shown that the new region extraction method outperforms others.

Establishment of the Monoenergetic Fluorescent X-ray Radiation Fields (교정용 단일에너지 형광 X-선장의 제작)

  • Kim, Jang-Lyul;Kim, Bong-Hwan;Chang, Si-Young;Lee, Jae-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.1
    • /
    • pp.33-47
    • /
    • 1998
  • Using a combination of an X-ray generator Installed in radiation calibration laboratory of Korea Atomic Energy Research Institute (KAERI) and a series of 8 radiators and filters described in ISO-4037, monoenergetic fluorescent X-rays from 8.6 keV to 75 keV were produced. This fluorescent X-rays generated by primary X-rays from radiator were discriminated $K_{\beta}$ lines with the aid of filter material and the only $K_{\alpha}$ X-rays were analyzed with the high purity Ge detector and portable MCA. The air kerma rates were measured with the 35 co ionization chamber and compared with the calculational results, and the beam uniformity and the scattered effects of radiation fields were also measured. The beam purities were more than 90 % for the energy range of 8.6 keV to 75 keV and the air kerma rates were from 1.91 mGy/h (radiator : Au, filter : W) to 54.2 mGy (radiator : Mo, filter : Zr) at 43 cm from center of the radiator. The effective area of beam at the measurement point of air kerma rates was 12 cm ${\times}$ 12 cm and the influence of scattered radiation was less than 3 %. The fluorescent X-rays established in this study could be used for the determination of energy response of the radiation measurement devices and the personal dosemeters in low photon energy regions.

  • PDF

Effects of Field Configuration Shielding Area and Changing of Density and Sensitivity on Tube Current and Image Quality in Automatic Exposure Control System (자동노출제어장치의 채광창 차폐정도와 농도, 감도의 변화가 관전류량과 영상품질에 미치는 영향)

  • Jeong, Min-Gyu;Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.635-642
    • /
    • 2020
  • The purpose of this study was to analysis the effects of shielding area of field configuration with changing of sensitivity and density on tube current (milliampere-seconds, mAs) and image quality in automatic exposure control (AEC) system. The equipment used a digital radiography device (Digital Diagnost, Philips, Netherlands), which has a integral type with an X-ray tube and an indirect digital detector. The AEC system conditions were consisted of 9 setting environments, that mode changing of the sensitivity (S200, S400, S800) and the density (+2.5, 0, -2.5). The tube current evaluated automatically exposed mAs under 81 combination conditions crossed by AEC conditions in fixed at 40 kVp. The image quality evaluated the radiographic images that selected valid images by visual assessment the radiographic images of the self-produced conical pyramid phantom and then measured their signal to noise ratio (SNR). As a result, the maximum tube current was 60.0 mAs that automatically exposed conditions were the 100% of shielding area and the sensitivity of S200 and the density of +2.5. The minimum tube current was 0.9 mAs with non-shielding area and the sensitivity of S800 and the density of -2.5. When the shielded area 0% with the sensitivity of S200 and the density of +2.5, the maximum SNR was the highest as 25.2. But when the shielded area 25% with the sensitivity of S800 and the density of -2.5, the minimum SNR was the lowest as 4.7.

Multirate Multicarrier DS/CDMA with 2-Domain Spreading (2차원 확산을 사용하는 다중전송률 MC-DS/CDMA 시스템)

  • Kim, Nam-Sun
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.16 no.4
    • /
    • pp.27-35
    • /
    • 2011
  • Multicarrier-Direct Sequence/Code Division Multiple Access(MC-DS/ CDMA) which is a combination of Orthogonal Frequency Division Multiplexing(OFDM) and DS/CDMA has been of significant interest as a means to take such advantages as bandwidth efficiency, high bit rate and robustness against multipath fading. In this paper we study a reduced-complexity multiuser detection aided multirate MC-DS/CDMA with time(T)-domain and frequency(F)-domain spreading. The one- dimensional orthogonal variable spreading factor(1D OVSF) code extracted from 2D OVSF code are used as a spreading code in T/F-domain. The proposed system will use code grouping interference cancellation(CGIC) receiver to reduce Multiuser Interference(MUI). The CGIC receiver uses code grouping by the correlation properties of 1D OVSF code and dose not requires the code information and activity of other user. The multiuser detector with CGIC receiver will be analyzed in Time- and Frequency-domain separately(jointly). The system performance is analytically derived in Additive White Gaussian Noise(AWGN) channel and we also compare the system performance between proposed system and T/F spreaded single(multi) rate multiuser MC-DS/CDMA system. In the computer simulation results, the proposed receiver of demonstrated huge performance improvement over conventional matched filter receiver.