• Title/Summary/Keyword: detection module

Search Result 696, Processing Time 0.023 seconds

Detection of Plastic Greenhouses by Using Deep Learning Model for Aerial Orthoimages (딥러닝 모델을 이용한 항공정사영상의 비닐하우스 탐지)

  • Byunghyun Yoon;Seonkyeong Seong;Jaewan Choi
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.2
    • /
    • pp.183-192
    • /
    • 2023
  • The remotely sensed data, such as satellite imagery and aerial photos, can be used to extract and detect some objects in the image through image interpretation and processing techniques. Significantly, the possibility for utilizing digital map updating and land monitoring has been increased through automatic object detection since spatial resolution of remotely sensed data has improved and technologies about deep learning have been developed. In this paper, we tried to extract plastic greenhouses into aerial orthophotos by using fully convolutional densely connected convolutional network (FC-DenseNet), one of the representative deep learning models for semantic segmentation. Then, a quantitative analysis of extraction results had performed. Using the farm map of the Ministry of Agriculture, Food and Rural Affairsin Korea, training data was generated by labeling plastic greenhouses into Damyang and Miryang areas. And then, FC-DenseNet was trained through a training dataset. To apply the deep learning model in the remotely sensed imagery, instance norm, which can maintain the spectral characteristics of bands, was used as normalization. In addition, optimal weights for each band were determined by adding attention modules in the deep learning model. In the experiments, it was found that a deep learning model can extract plastic greenhouses. These results can be applied to digital map updating of Farm-map and landcover maps.

Performance Evaluation of MF Membrane Filtration Pilot System Associated with Pre Coagulation-Sedimentation with Iron-Based Coagulant and Chlorination Treatment (철염계 응집제를 사용한 전응집침전, 전염소처리와 PVDF 재질의 정밀여과 막을 조합한 막 여과 정수처리시스템 평가에 관한 연구)

  • Lee, Sanghyup;Jang, Nakyong;Yoshimasa, Watanabe;Choi, Yongsu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.5
    • /
    • pp.588-597
    • /
    • 2004
  • In this research, we investigated the variation of transmembrane pressure and permeate water quality with pre coagulation and sedimentation with iron based coagulant and chlorination of feed water for PVDF (polyvinylidene fluoride) based MF membrane filtration. NaCIO was fed to the membrane module with dosage of 0.5mg/L and maintained during filtration. To observe the effect of raw water, three types of raw and processed waters, including river surface water, coagulated water and coagulated-settled water, were applied. In case of river surface water, the transmembrane pressure increased drastically in 500 hours of operation. On the contrary, no significant increase in transmembrane pressure was observed for 1,200 hours of operation for coagulated water and coagulated-settled waters. The turbidity of permeate was lower than a detection limit of equipment for all raw waters. The removal efficiency of humic substances of coagulated water and coagulated-settled water was approximate ten times of that of surface river water. And, the removal efficiency of TOC and DOC was approximate two times of that of surface river water. From the results of plant operation, stable operation was maintained at $0.9m^3/m^2{\cdot}day$ filtration flux through the combination of pre-coagulation and pre-chlorination. However, the water quality of permeate was the best when pre-coagulation-sedimentation process was combined with pre-chlorination.

A Development of Ultrasonic Based Distance Meter Through Detachment of Receiving and Transmitting Capacitive Ultrasonic Transducer (송.수신 분리형 초음파 거리 측정기 개발)

  • Kim Jung-Hoon;Chong Jong-Wha
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.3 s.309
    • /
    • pp.41-50
    • /
    • 2006
  • This paper presents a novel ultrasonic sensor system to overcome limited distance detection range that can be measured only more than 30cm by single ultrasonic transducer. This is accomplished by separation of receiving capacitive ultrasonic transducer from transmitting capacitive ultrasonic transducer. And hardwares and software of the system are described in detail. The system makes very close range as well as long range detect by wireless precisely. Frequency of trigger pulse is 10Hz, but it is very low frequency for transmitting data in wireless module. Therefore, for triggering between receiver and transmitter, an algorithm for mixing and distinguishing trigger pulse from carrier pulse by software is proposed. The system is designed by common microprocessor 8051. The performance of the proposed method has been assessed through two types. The first, transmitting and receiving transducer are put on both sides. And then, distance of two point is measured as far as 0mm. Secondly, transmitting transducer send out ultrasonic pulse and measure the time of flight(TOF) until a first echo from an object detected by the detached receiving transducer. The distance between the detached transducers and a reflecting object is measured as far as 7cm. Images of measured ultrasonic waves and TOF for two methods presented to prove effectiveness of results.

An Interactive Monitoring Application for Secure Experiments of Guidance System for Person with Visual Impairment (시각장애인 보행지원 시스템의 안전한 실험을 위한 대화식 모니터링 어플리케이션)

  • Lee, Jin-Hee;Lee, Eun-Seok;Shin, Byeong-Seok
    • Journal of the HCI Society of Korea
    • /
    • v.8 no.2
    • /
    • pp.1-8
    • /
    • 2013
  • In previous study, we developed a guidance system outdoors for person with visual impairment to be able to walk safely to the destination. The volunteers are exposed to dangerous situations since they are performed to the experiments in the outdoors. In order to solve the problem, we propose an interactive application that monitors the volunteer wearing guidance system and warns remotely the volunteer about dangerous situations. The application is used to remote wireless communication with guidance system through Bluetooth module that is built in a laptop computer, without additional device. Therefore, we can monitor in real time user's location and guided contents to user, and it is possible to check a path to the destination and POI (Point of Interest) coordinate values. As using a proposed monitoring application, it is possible to perform safe experiment with the rapid situation awareness and fast detection of dangerous.

  • PDF

Efficient Kernel Integrity Monitor Design for Commodity Mobile Application Processors

  • Heo, Ingoo;Jang, Daehee;Moon, Hyungon;Cho, Hansu;Lee, Seungwook;Kang, Brent Byunghoon;Paek, Yunheung
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.1
    • /
    • pp.48-59
    • /
    • 2015
  • In recent years, there are increasing threats of rootkits that undermine the integrity of a system by manipulating OS kernel. To cope with the rootkits, in Vigilare, the snoop-based monitoring which snoops the memory traffics of the host system was proposed. Although the previous work shows its detection capability and negligible performance loss, the problem is that the proposed design is not acceptable in recent commodity mobile application processors (APs) which have become de facto the standard computing platforms of smart devices. To mend this problem and adopt the idea of snoop-based monitoring in commercial products, in this paper, we propose a snoop-based monitor design called S-Mon, which is designed for the AP platforms. In designing S-Mon, we especially consider two design constraints in the APs which were not addressed in Vigilare; the unified memory model and the crossbar switch interconnect. Taking into account those, we derive a more realistic architecture for the snoop-based monitoring and a new hardware module, called the region controller, is also proposed. In our experiments on a simulation framework modeling a productionquality device, it is shown that our S-Mon can detect the rootkit attacks while the runtime overhead is also negligible.

Surface Measurement of Microstructures Using Optical Pick-up Based Scanner (광픽업 스캔 장치를 이용한 미소 구조물의 표면 측정)

  • Kim, Jae-Hyun;Park, Jung-Yul;Lee, Seung-Yop
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.1
    • /
    • pp.73-76
    • /
    • 2010
  • The issue of inspection and characterization of microstructures has emerged as a major consideration in design, fabrication, and detection of MEMS devices. However, the conventional measurement techniques, including scanning electron microscopy (SEM) imaging, atomic force microscopy (AFM) scanning, and mechanical surface profiler, require often destructive process or may be difficult to measure with a wafer scale. In this paper, we characterize the surface profiles of microstructures using an optical scanner based on a DVD pick-up module. Scanning images of the microstructures are successfully generated using the intensity of reflected light from different depths of the surface profiles, based on the focus error signal (FES) from photodiodes. It is shown that the proposed optical scanner can be used as an alternative measurement system with high performance and low cost, compared to conventional measurement techniques.

Adaptive Sensing based on Fuzzy System for Ubiquitous Sensor Networks (유비쿼터스 센서네트워크를 위한 퍼지시스템 기반 적응형 센싱)

  • Mateo, Romeo Mark A.;Lee, Jae-Wan
    • Journal of Internet Computing and Services
    • /
    • v.9 no.3
    • /
    • pp.51-58
    • /
    • 2008
  • Wireless sensor networks are used by various application areas to implement smart data processing and ubiquitous system. In the recent research of parking management system based on wireless sensor networks, adaptive sensing and efficient data processing are not considered. The effectiveness of implementing these distributed computing devices affects the performance of the applications in parking management. This paper proposes an adaptive sensing using fuzzy wireless sensor for the ubiquitous networks of parking management system. The fuzzy inference system is encoded in the sensor for efficient car presence detection. Moreover, a rule base adaptive module is proposed which wirelessly transmit the new values to each sensor for adapting the environment of car park area. The result of experiments shows that the fuzzy wireless sensor provides more throughputs and less time delays compared to a normal method of data gathering by wireless sensors.

  • PDF

QUANTITATIVE MONITORING OF TISSUE OXYGENATION BY TIME-RESOLVED SPECTROSCOPY

  • Yamashita, Yutaka;Oda, Motoki;Ohmae, Etsuko;Tsuchiya, Yutaka
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.2101-2101
    • /
    • 2001
  • Near-infrared spectroscopy is now being used in clinical diagnosis as a non-invasive monitor of tissue oxygenation state. However, due to lack of the optical pathlength information within tissues, it is still difficult to quantitate the hemoglobin concentration with present CW techniques. Time-resolved spectroscopy (TRS), which measures temporal profiles of emerging light from tissues, enables to estimate the pathlength distribution within tissues by converting time to distance. Consequently, quantitative measurement of tissue oxygenation is possible by analyzing the data with optical diffusion equation 1) or our Microscopic Beer-Lambert law2). Time-Resolved Spectroscopy System : TRS-1O3) Our TRS-10 system consists of a three-wavelength (759, 797, 833 nm) PLP as pulsed light source, a high speed PMT with high sensitivity and three signal-processing circuits for time-resolved measurement (CFD/TAC, A/D converter and histogram memory). Optical pulse train consisting of 759, 797 and 833nm is generated by PLP at 5㎒ repetition rate and irradiated a sample through a single optical fiber. The diffuse-reflected light from the sample is collected by a bundle fiber and then detected by the PMT for single photon measurement. After being amplified by a following fast amplifier, the electrical signals for each wavelength are picked out by CFD/TAC module. Then, a signal processing circuit integrated the TRS data for each wavelength individually. The simultaneous TRS measurement for three wavelengths achieved without any optical or mechanical switch. Experiment and Results Input and detection fibers of TRS-10 were attached at the human forehead with a fiber separation of 3cm. TRS measurements were continuously performed for about 20 minutes including 2 minutes hyper ventilation. It was observed that the total hemoglobin concentration was decreasing during the hyper ventilation and recovered until 2 minutes after hyper ventilation. On the other hand, the deoxy-hemoglobin concentration began to increase after hyper ventilation and had its peak at around 2 minute later, showing 502 drop from 75% to 60% due to inhibition of breathing by performing hyper ventilation. The results showed that this system might be able to quantitate the concentrations of oxy- and deoxy-hemoglobin in the human brain.

  • PDF

Electrical Characteristic of Power MOSFET with Zener Diode for Battery Protection IC

  • Kim, Ju-Yeon;Park, Seung-Uk;Kim, Nam-Soo;Park, Jung-Woong;Lee, Kie-Yong;Lee, Hyung-Gyoo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.1
    • /
    • pp.47-51
    • /
    • 2013
  • A high power MOSFET switch based on a 0.35 ${\mu}m$ CMOS process has been developed for the protection IC of a rechargeable battery. In this process, a vertical double diffused MOS (VDMOS) using 3 ${\mu}m$-thick epi-taxy layer is integrated with a Zener diode. The p-n+Zener diode is fabricated on top of the VDMOS and used to protect the VDMOS from high voltage switching and electrostatic discharge voltage. A fully integrated digital circuit with power devices has also been developed for a rechargeable battery. The experiment indicates that both breakdown voltage and leakage current depend on the doping concentration of the Zener diode. The dependency of the breakdown voltage on doping concentration is in a trade-off relationship with that of the leakage current. The breakdown voltage is obtained to exceed 14 V and the leakage current is controlled under 0.5 ${\mu}A$. The proposed integrated module with the application of the power MOSFET indicates the high performance of the protection IC, where the overcharge delay time and detection voltage are controlled within 1.1 s and 4.2 V, respectively.

The Effect of the Fault Tolerant Capability due to Degradation of the Self-diagnostics Function in the Safety Critical System for Nuclear Power Plants (원자력발전소 안전필수시스템 고장허용능력에 대한 자가진단기능 저하 영향 분석)

  • Hur, Seop;Hwang, In-Koo;Lee, Dong-Young;Choi, Heon-Ho;Kim, Yang-Mo;Lee, Sang-Jeong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.8
    • /
    • pp.1456-1463
    • /
    • 2010
  • The safety critical systems in nuclear power plants should be designed to have a high level of fault tolerant capability because those systems are used for protection or mitigation of the postulated accidents of nuclear reactor. Due to increasing of the system complexity of the digital based system in nuclear fields, the reliability of the digital based systems without an auto-test or a self-diagnostic feature is generally lower than those of analog system. To overcome this problem, additional redundant architectures in each redundant channel and self-diagnostic features are commonly integrated into the digital safety systems. The self diagnostic function is a key factor for increasing fault tolerant capabilities in the digital based safety system. This paper presents an availability and safety evaluation model to analyze the effect to the system's fault tolerant capabilities depending on self-diagnostic features when the loss or erroneous behaviors of self-diagnostic function are expected to occur. The analysis result of the proposed model on the several modules of a safety platform shows that the improvement effect on unavailability of each module has generally become smaller than the result of usage of conventional models and the unavailability itself has changed significantly depending on the characteristics of failures or errors of self-diagnostic function.