• Title/Summary/Keyword: detection kit

Search Result 307, Processing Time 0.03 seconds

Effective Application of CF11 Cellulose for Detection of Apple scar skin viroid in Apple

  • Chung, Bong-Nam;Cho, In-Sook;Cho, Jeom-Deog
    • The Plant Pathology Journal
    • /
    • v.25 no.3
    • /
    • pp.291-293
    • /
    • 2009
  • The low virus titer in woody plant tissues and the presence of inhibitor compounds such as polyphenols, tannins and polysaccharides are common difficulties that compromise purification of plant viroids from their woody hosts. A simple, reliable method of RNA isolation using CF11 cellulose column on a microcentrifuge tube scale for detecting Apple scar skin viroid (ASSVd) in apple was developed. Total RNA extracted from leaf, woody bark and the fruit skin was used for reverse transcription. RT-PCR products could be detected from RNA prepared from dormant woody bark, fruit skin and fresh leaves with both the CF11 cellulose column method and NucliSens extractor in February, August and November. Meanwhile, with the RNeasy kit RT-PCR, products were detected only in leaves and not from bark or fruit skin. The PCR product, about 330 base pairs, was analyzed by agarose gel electrophoresis. The CF11 cellulose column method was effective for detecting ASSVd. The method enabled the processing of a large numbers of samples of dormant woody bark, leaf and fruit skin of apple.

Comparison between indirect immunofluorescent antibody (IFA) test and enzyme-linked immunosorbent assay (ELISA) for the detection of antibody to porcine reproductive and respiratory syndrome virus(PRRSV) (돼지 생식기호흡기증후군 바이러스항체 검색에 있어 간접형광항체법(IFA) 과 효소면역법(ELISA)의 진단효율 비교)

  • Park, Choi-kyu;Lyoo, Young-soo;Lee, Chang-hee;Jung, Jong-wook
    • Korean Journal of Veterinary Research
    • /
    • v.38 no.2
    • /
    • pp.314-318
    • /
    • 1998
  • An establishment of effective control measures to PRRSV infection in swine industry depends on a sensitive and specific diagnosis to detect either viral antigen and/or antibodies to PRRSV. Several diagnostic methods are available to detect antibodies against PRRSV, including IPMA, IFA and ELISA tests have been successfully developed. Sensitivity of the indirect immunofluorescent assay in MA-104 cells using Korean field isolate PL96-1 was superior to that of VR-2332 and field isolate PL96-2. Sensitivity and specificity of the IFA test with PL96-1 were comparable to those of commercial ELISA test kit but ELISA test was more sensitive for the detection of declining antibodies to PRRSV in finishing pigs. In this study we concluded that IFA and ELISA test could be utilized to detect antibodies to PRRSV and the results generated from these two tests were comparable and there were no significant difference between these two tests.

  • PDF

Development of Web-cam Game using Hand and Face Skin Color (손과 얼굴의 피부색을 이용한 웹캠 게임 개발)

  • Oh, Chi-Min;Aurrahman, Dhi;Islam, Md. Zahidul;Kim, Hyung-Gwan;Lee, Chil-Woo
    • 한국HCI학회:학술대회논문집
    • /
    • 2008.02b
    • /
    • pp.60-63
    • /
    • 2008
  • The sony Eytoy is developed on Playstation 2 using webcam for detecting human. A user see his appearance in television and become real gamer in the game. It is very different interface compared with ordinary video game which uses joystick. Although Eyetoy already was made for commercial products but the interface method still is interesting and can be added with many techniques like gesture recognition. In this paper, we have developed game interface with image processing for human hand and face detection and with game graphic module. And we realize one example game for busting balloons and demonstrated the game interface abilities. We will open this project for other developers and will be developed very much.

  • PDF

Comparative Studies on Detecting Methods of Fecal Indicators (Coliforms) in Surface Water (지표수에서의 분변오염지표세균 (대장균군) 검출방법의 비교연구)

  • Park, Ji-Eun;Kim, Sun-Duck;Cho, Ju-Rae;Kim, Sang-Hyun;Lee, Hae-Jin;Lee, Young-Ok
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.6
    • /
    • pp.1052-1059
    • /
    • 2006
  • For monitoring the fecal pollution at Nak-Dong River, one of the eutrophicated rivers, the differences between total coliforms (TC) and fecal coliforms (FC) using both of membrane filtration (MF)/MPN method, and also fecal streptococcus (FS) by MF-method was investigated. To evaluate the correlation between TC, FC, and FS statistical analyses were performed by using Minitab. And a part of the presumptive TC/FC and background colonies was purified and identified using API 20E kit (Biomeriux). As results, most (89%) of presumptive FC by MF was identified as Escherichia coli while only 14% (MPN) and 11% (MF) of TC were identified as E. coli. Furthermore, FC by MF was correlated significantly with other fecal indicators (TC/FS by MF and FC by MPN), while TC by MPN was not correlated with any other indicators. Thus, the detection of FC by MF-method may be the most reasonable for monitoring the fecal pollution.

A Quinoline carboxamide based Fluorescent Probe's Efficient Recognition of Aluminium Ion and its Application for Real Time Monitoring

  • Manivannan, Ramalingam;Ryu, Jiwon;Son, Young-A
    • Textile Coloration and Finishing
    • /
    • v.32 no.4
    • /
    • pp.185-192
    • /
    • 2020
  • A novel binding site for metal ion made by designing molecule with tetrazolo quinoline with hydrazine carboxamide (TQC) and the designed molecule successfully synthesized. The probe works by selectively detecting Al3+ ion via both fluorimetric and colorimetric approach. The probe's effectiveness towards aluminium ion detection is highly sensitive and selective with no substantial interference with other competing ions. The added Al3+ ion to TQC fetched a rapid change of visual color to yellow from colorless, also the response of fluorescence turn-on. The fluorescence turn-on and color change visibly by the probe TQC with Al3+ ion credited to the ICT phenomenon (intramolecular charge-transfer transition). The likely interaction of the probe with aluminium ion has also been there predicted from ESI-MS spectral analysis results. The usefulness of the probe confirmed by practical utility by making a test kit to monitor Al3+ ion in water which showed a naked eye detection by notable color change.

Non-contact Heart Rate Monitoring using IR-UWB Radar and Lomb-Scargle Periodogram (IR-UWB 레이더와 Lomb-Scargle Periodogram을 이용한 비접촉 심박 탐지)

  • Byun, Sang-Seon
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.17 no.1
    • /
    • pp.25-32
    • /
    • 2022
  • IR-UWB radar has been regarded as the most promising technology for non-contact respiration and heartbeat monitoring because of its ability of detecting slight motion even in submillimeter range. Measuring heart rate is most challenging since the chest movement by heartbeat is quite subtle and easily interfered with by a random body motion or background noise. Additionally, periodic sampling can be limited by the performance of computer that handles the radar signals. In this paper, we deploy Lomb-Scargle periodogram method that estimates heart rate even with irregularly sampled data and uneven signal amplitude. Lomb-Scargle periodogram is known as a method for finding periodicity in irregularly-sampled and noisy data set. We also implement a motion detection scheme in order to make the heart rate estimation pause when a random motion is detected. Our scheme is implemented using Novelda's X4M03 radar development kit and its corresponding drivers and Python packages. Experimental results show that the estimation with Lomb-Scargle periodogram yield more accurate heart rate than the method of measuring peak-to-peak distance.

Comparison of Upgraded Methods for Detecting Pathogenic Escherichia coli in Foods Using Centrifugation or Filtration

  • Choi, Yukyung;Lee, Heeyoung;Lee, Soomin;Kim, Sejeong;Lee, Jeeyeon;Ha, Jimyeong;Oh, Hyemin;Yoon, Yohan
    • Food Science of Animal Resources
    • /
    • v.37 no.6
    • /
    • pp.799-803
    • /
    • 2017
  • In the present study, centrifugation and filtration pretreatments were evaluated to decrease sample preparation time and to improve the sensitivity and specificity of multiplex polymerase chain reaction (PCR) for the detection of low levels of pathogenic Escherichia coli in various foods. Pathogenic E. coli (E. coli NCCP11142, E. coli NCCP14037, E. coli NCCP 14038, E. coli NCCP14039, and E. coli NCCP15661) was inoculated into pork, beef, and baby leafy vegetables at 1, 2, and 3 Log CFU/g. The samples were shaken 30 times (control), then centrifuged or filtered. DNA extracts from the samples were subjected to PCR using the $Powerchek^{TM}$ Diarrheal E. coli 8-plex Detection Kit. In the pork samples, no E. coli was detected in the control samples, while E. coli were detected in 100% of 3-Log CFU/g inoculated and centrifuged samples, and in 100% of 2 and 3-Log CFU/g inoculated, and filtered samples. In the beef samples, all control samples appeared to be E. coli-negative, while E. coli was detected in 50-75% of centrifuged samples, regardless of inoculated level, and in 100% of 2 and 3-Log CFU/g inoculated, and filtered samples. In baby leafy vegetables, E. coli were not detected in 25-50% of the control samples, while E. coli were detected in 0-25% of the centrifuged samples, and 75-100% of the filtered samples, depending on the inoculum amount. In conclusion, filtration pretreatment can be used to minimize sample preparation time, and improve the sensitivity and specificity of rapid detection of pathogenic E. coli in various foods.

Choosing Optimal STR Markers for Quality Assurance of Distributed Biomaterials in Biobanking

  • Chung, Tae-Hoon;Lee, Hee-Jung;Lee, Mi-Hee;Jeon, Jae-Pil;Kim, Ki-Sang;Han, Bok-Ghee
    • Genomics & Informatics
    • /
    • v.7 no.1
    • /
    • pp.32-37
    • /
    • 2009
  • The quality assurance (QA) is of utmost importance in biobanks when archived biomaterials are distributed to biomedical researchers. For sample authentication and cross-contamination detection, the two fundamental elements of QA, STR genotyping is usually utilized. However, the incorporated number of STR markers is highly redundant for biobanking purposes, resulting in time and cost inefficiency. An index to measure the cross-contamination detection capability of an STR marker, the mixture probability (MP), was developed. MP as well as other forensic parameters for STR markers was validated using STR genotyping data on 2328 normal Koreans with the commercial AmpFlSTR kit. For Koreans, 7 STR marker (D2S1338, FGA, D18S51, D8S1179, D13S317, D21S11, vWA) set was sufficient to provide discrimination power of ${\sim}10^{-10}$ and cross-contamination detection probability of ${sim}1$. Interestingly, similar marker sets were obtained from African Americans, Caucasian Americans, and Hispanic Americans under the same level of discrimination power. Only a small subset of commonly used STR markers is sufficient for QA purposes in biobanks. A procedure for selecting optimal STR markers is outlined using STR genotyping results from normal Korean population.

A Simple, Rapid, and Automatic Centrifugal Microfluidic System for Influenza A H1N1 Viral RNA Purification

  • Park, Byung Hyun;Jung, Jae Hwan;Oh, Seung Jun;Seo, Tae Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.277.1-277.1
    • /
    • 2013
  • Molecular diagnostics consists of three processes, which are a sample pretreatment, a nucleic acid amplification, and an amplicon detection. Among three components, sample pretreatment is an important process in that it can increase the limit of detection by purifying nucleic acid in biological sample from contaminants that may interfere with the downstream genetic analysis such as nucleic acid amplification and detection. To achieve point-of-care virus detection system, the sample pretreatment process needs to be simple, rapid, and automatic. However, the commercial RNA extraction kits such as Rneasy (Qiagen) or MagnaPure (Roche) kit are highly labor-intensive and time-consuming due to numerous manual steps, and so it is not adequate for the on-site sample preparation. Herein, we have developed a rotary microfluidic system to extract and purify the RNA without necessity of external mechanical syringe pumps to allow flow control using microfluidic technology. We designed three reservoirs for sample, washing buffer, and elution buffer which were connected with different dimensional microfluidic channels. By controlling RPM, we could dispense a RNA sample solution, a washing buffer, and an elution buffer successively, so that the RNA was captured in the sol-gel solid phase, purified, and eluted in the downstream. Such a novel rotary sample preparation system eliminates some complicated hardwares and human intervention providing the opportunity to construct a fully integrated genetic analysis microsystem.

  • PDF

Detection of HCV-RNA by Reverse Transcription Polymerase Chain Reaction Using Biotinylated and Radioiodinated Primers (역전사 중합효소 연쇄반응(RT-PCR)에 의한 HCV-RNA의 검출 : Biotin 및 방사성옥소 표지 Primer로 구성된 Kit의 이용)

  • Ryu, Jin-Sook;Moon, Dae-Hyuk;Cheon, Jun-Hong;Chung, Yoon-Young;Park, Hung-Dong;Chung, Young-Hwa;Lee, Young-Sang
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.2
    • /
    • pp.220-226
    • /
    • 1994
  • This study was performed to evaluate the clinical applicability of the reverse transcription polymerase chain reaction (RT-PCR ) kit of HCV-RNA using biotinylated and radioiodinated primers. Study subjects were 118 patients with positive anti-HCV. HCV-RNA in patient's serum was extracted by guanidium thiocyanate method. After first amplification, the product was reamplified by primers labelled with biotin and I-125. The final amplification product was defected by counting the radioactivity after incubation in avidin coated tubes. In 51 samples, the test was repeated for evaluation of reproducibility. This new method was also compared with conventional RT-PCR methods in 34 samples from patients with chronic liver disease. The results were as follows ; 1) HCV-RNA was positive in 85(97%)of 88 patients with chronic liver disease, and in 23 (73%) of 30 patients with normal liver function. 2) In comparison with conventional method, HCV-RNA was detected in 32(94%) of 34 patients with new method, whereas in 27(79%) of the same group with conventional method. 3) Repeated test with new method in 52 samples demonstrated 82% of concordant result. In conclusion, new method with biotinylated and radioiodinated primers was more sensitive than conventional method. However, great care must be taken for quality control because there were considerable interassay variation and possiblity of false positivity and false negativity.

  • PDF