• Title/Summary/Keyword: detectable distance

Search Result 38, Processing Time 0.027 seconds

Analysis and Simulation of SF6 Tracer Experiments for Tracking the Pollutant Transport (오염물질 이동 추적을 위한 SF6 추적자 실험 분석과 모사 연구)

  • 김영성;조성호
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.5
    • /
    • pp.397-410
    • /
    • 1998
  • Tracer experiments were performed 4 times in December 1992 on the relatively flat terrain and nearby building area adjacent to the Taedok Science Town in Korea. Each experiment was continued for relatively short period of 1 or 2 hours with intermittent release of SF6 up to 2.07g/s at 10m height. Movement of tracer plume was tracked by a continuous tracer analyzer installed on an air monitoring van. Simulation with INPUFF was carried out to analyze and predict experiments. Measured profiles of tracer plume were narrow and sharp while predicted profiles by INPUFF were broad and slowly varied. Tracer plumes were detected at a short distance of 0.5 to 2.2 km mainly due to intermittent release and high value of lower detectable limit. Various experimental conditions were tested by INPUFF simulation in order to find desirable conditions. Higher wind speed and less variable wind direction could yield longer distance of plume tracking only when the lower detectable limit was sufficiently low. Distance of plume tracking was long and did not much depend on the lower detectable limit in stable atmospheric conditions.

  • PDF

Improvement of Processing Speed of the Doppler Filter in a Low Power Radar (저 출력 레이더의 도플러필터의 처리속도 개선)

  • Park, Jeong-Ho;Jeong, Hong
    • Proceedings of the IEEK Conference
    • /
    • 2001.06d
    • /
    • pp.167-170
    • /
    • 2001
  • A low power pulse Doppler radar should integrate a large number of data to provide a required maximum detectable distance. Doppler filter needs a window that has good out-of-bard rejection level to maintain high dynamic range. From these facts, we can apply decimation and presumming to increase the speed of Doppler processing. This Paper investigates the efficiencies of several decimation methods and the loss of presumming. And I propose a method to increase processing speed but to maintain the maximum detectable distance.

  • PDF

Impact of aperture-thickness on the real-time imaging characteristics of coded-aperture gamma cameras

  • Park, Seoryeong;Boo, Jiwhan;Hammig, Mark;Jeong, Manhee
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1266-1276
    • /
    • 2021
  • The mask parameters of a coded aperture are critical design features when optimizing the performance of a gamma-ray camera. In this paper, experiments and Monte Carlo simulations were performed to derive the minimum detectable activity (MDA) when one seeks a real-time imaging capability. First, the impact of the thickness of the modified uniformly redundant array (MURA) mask on the image quality is quantified, and the imaging of point, line, and surface radiation sources is demonstrated using both cross-correlation (CC) and maximum likelihood expectation maximization (MLEM) methods. Second, the minimum detectable activity is also derived for real-time imaging by altering the factors used in the image quality assessment, consisting of the peak-to-noise ratio (PSNR), the normalized mean square error (NMSE), the spatial resolution (full width at half maximum; FWHM), and the structural similarity (SSIM), all evaluated as a function of energy and mask thickness. Sufficiently sharp images were reconstructed when the mask thickness was approximately 2 cm for a source energy between 30 keV and 1.5 MeV and the minimum detectable activity for real-time imaging was 23.7 MBq at 1 m distance for a 1 s collection time.

Portable Infrared Laser Transmitter Based on a Beam Shaper Enabling a Highly Uniform Detectable Beam Width

  • Yue, Wenjing;Kim, Haeng-Jung;Lee, Sang-Shin
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.6
    • /
    • pp.486-490
    • /
    • 2013
  • A portable infrared laser transmitter delivering a highly uniform detectable beam was demonstrated. It incorporates a flexible beam shaper, comprising a perforated diffuser sheet in conjunction with a pinhole. The beam shaper plays the prominent role of flexibly tailoring the incoming light via both scattering and diffraction, in order to equalize the effective beam width over a long distance. The intensity profile of a generated beam was practically observed, demonstrating that a substantially uniform beam of 70-cm width was achieved for a given threshold detection level, with an average deviation of 6% over a range of 600 m.

Low Loss Frequency Doubler for RFID (RFID용 저손질 주파수 체배기)

  • Kim, JIn-Su;Hwang, Hee-Yong
    • Journal of Industrial Technology
    • /
    • v.28 no.A
    • /
    • pp.177-184
    • /
    • 2008
  • A low loss frequency doubler operated on low power for the RFID harmonic tags is presented. Using the excellent nonlinear characteristics of the Schottky barrier diode and proper matching networks between the diode and ports, the low conversion loss of the harmonic tag is accomplished. This doubler could be used to increase the detectable distance of the conventional RFID system adopted harmonic tags.

  • PDF

Model-Based Simulation Analysis of Wicking Behavior in Hygroscopic Cotton Fabric

  • Hong, Cheol-Jae;Kim, Byung-Jick
    • Journal of Fashion Business
    • /
    • v.20 no.6
    • /
    • pp.66-78
    • /
    • 2016
  • Hygroscopic knitted cotton fabric was found to spontaneously absorb water showing a significantly wide concentration gradient in the absorption direction. A semi-empirical diffusion model was introduced to describe how the wicking behavior compared to the classical capillary model (Washburn's equation), which has been widely used in the textiles industry. The capillary sorption curve and the permeability coefficient, which are key variables for the model equations, were measured using an electronic balance. The concentration profile as a function of the wicking distance and the elapsed time was derived, based on the diffusion model. From the concentration profile, the wicking distance detectable by the human eye or a digital camera with the aid of an image-analysis system, could be described realistically as a function of the time. The classical capillary model could be modified by introducing the tortuous correction factor to match the diffusion model. Wicking models and data-processing techniques in the work could provide useful tools for objectively evaluating the textile's wicking performances.

A Study on the quantitative measurement methods of MRTD and prediction of detection distance for Infrared surveillance equipments in military (군용 열영상장비 최소분해가능온도차의 정량적 측정 방법 및 탐지거리 예측에 관한 연구)

  • Jung, Yeong-Tak;Lim, Jae-Seong;Lee, Ji-Hyeok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.5
    • /
    • pp.557-564
    • /
    • 2017
  • The purpose of the thermal imaging observation device mounted on the K's tank in the Republic of Korea military is to convert infrared rays into visual information to provide information about the environment under conditions of restricted visibility. Among the various performance indicators of thermal observation devices, such as the view, magnification, resolution, MTF, NETD, and Minimum Resolvable Temperature Difference (MRTD), the MRTD is the most important, because it can indicate both the spatial frequency and temperature resolvable. However, the standard method of measuring the MRTD in NATO contains many subjective factors. As the measurement result can vary depending on subjective factors such as the human eye, metal condition and measurement conditions, the MRTD obtained is not stable. In this study, these qualitative MRTD measurement systems are converted into quantitative indicators based on a gray scale using imaging processing. By converting the average of the gray scale differences of the black and white images into the MRTD, the mean values can be used to determine whether the performance requirements required by the defense specification are met. The (mean) value can also be used to discriminate between detection, recognition and identification and the detectable distance of the thermal equipment can be analyzed under various environmental conditions, such as altostratus, heavy rain and fog.

Development of X-ray PIV Technique and its Application to Blood Flow (X-ray PIV 기법의 개발과 혈액 유동에의 적용연구)

  • Kim, Guk Bae;Lee, Sang Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.11 s.242
    • /
    • pp.1182-1188
    • /
    • 2005
  • An x-ray PIV (Particle Image Velocimetry) technique was developed to measure quantitative information on flows inside opaque conduits and on opaque-fluid flows. At first, the developed x-ray PIV technique was applied to flow in an opaque Teflon tube. To acquire x-ray images suitable for PIV velocity field measurements, refraction-based edge enhancement mechanism was employed using detectable tracer particles. The optimal distance between with the sample and detector was experimentally determined. The resulting amassed velocity field data were in reasonable agreement with the theoretical prediction. The x-ray PIV technique was also applied to blood flow in a microchannel. The flow pattern of blood was visualifed by enhancing the diffraction/interference -bas ed characteristic s of blood cells on synchrotron x-rays without any contrast agent or tracer particles. That is, the flow-pattern image of blood was achieved by optimizing the sample (blood) to detector distance and the sample thickness. Quantitative velocity field information was obtained by applying PIV algorithm to the enhanced x-ray flow images. The measured velocity field data show a typical flow structure of flow in a macro-scale channel.

Fabrication and Characteristics of the Hall Sensor Using Differential Detection Method (차동검출방식을 이용한 홀 센서의 제작 및 특성)

  • Jeong, W.C.;Nam, T.C.
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.4
    • /
    • pp.225-233
    • /
    • 1998
  • The principle, design, and application of a gear-tooth sensor for the rough environmental conditions such as high temperatures of up to $150^{\circ}C$ are studied. The rotation of a tooth wheel is detected by a couple of Hall elements manufactured on the SIMOX wafer by a methode of differential detection using bipolar silicon technology. The product sensitivity of the Hall element is about 510 V/AT over a wide temperature range of $-40^{\circ}C{\sim}150^{\circ}C$. The differential Hall sensor makes the maximum possible distance between sensor and tooth wheel wider than that when single Hall element is used over a wide temperature range, and the maximum detectable distance is 4.5mm at driving current of 4mA.

  • PDF

Adaptive planar vision marker composed of LED arrays for sensing under low visibility

  • Kim, Kyukwang;Hyun, Jieum;Myung, Hyun
    • Advances in robotics research
    • /
    • v.2 no.2
    • /
    • pp.141-149
    • /
    • 2018
  • In image processing and robotic applications, two-dimensional (2D) black and white patterned planar markers are widely used. However, these markers are not detectable in low visibility environment and they are not changeable. This research proposes an active and adaptive marker node, which displays 2D marker patterns using light emitting diode (LED) arrays for easier recognition in the foggy or turbid underwater environments. Because each node is made to blink at a different frequency, active LED marker nodes were distinguishable from each other from a long distance without increasing the size of the marker. We expect that the proposed system can be used in various harsh conditions where the conventional marker systems are not applicable because of low visibility issues. The proposed system is still compatible with the conventional marker as the displayed patterns are identical.