• Title/Summary/Keyword: detect

Search Result 14,595, Processing Time 0.033 seconds

Model - Based Sensor Fault Detection and Isolation for a Fuel Cell in an Automotive Application (모델 기반 연료전지 스택 온도 센서 고장 감지 및 판별)

  • Han, Jaeyoung;Kim, Younghyeon;Yu, Sangseok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.11
    • /
    • pp.735-742
    • /
    • 2017
  • In this study, an effective model-based sensor fault detection methodology that can detect and isolate PEM temperature sensors fault is introduced. In fuel cell vehicle operation process, the stack temperature affects durability of a fuel cell. Thus, it is important for fault algorithm to detect the fault signals. The major objective of sensor fault detection is to guarantee the healthy operations of the fuel cell system and to prevent the stack from high temperature and low temperature. For the residual implementation, parity equation based on the state space is used to detect the sensors fault as stack temperature and coolant inlet temperature, and residual is compared with the healthy temperature signals. Then the residuals are evaluated by various fault scenarios that detect the presence of the sensor fault. In the result, the designed in this study fault algorithm can detect the fault signal.

A Study on the Detection of Fallen Workers in Shipyard Using Deep Learning (딥러닝을 이용한 조선소에서 쓰러진 작업자의 검출에 관한 연구)

  • Park, Kyung-Min;Kim, Seon-Deok;Bae, Cherl-O
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.6
    • /
    • pp.601-605
    • /
    • 2020
  • In large ships with complex structures, it is difficult to locate workers. In particular, it is not easy to detect when a worker falls down, making it difficult to respond quickly. Thus, research is being conducted to detect fallen workers using a camera or by attaching a device to the body. Existing image-based fall detection systems have been designed to detect a person's body parts; hence, it is difficult to detect them in various ships and postures. In this study, the entire fall area was extracted and deep learning was used to detect the fallen shipworker based on the image. The data necessary for learning were obtained by recording falling states at the shipyard. The amount of learning data was augmented by flipping, resizing, and rotating the image. Performance evaluation was conducted with precision, reproducibility, accuracy, and a low error rate. The larger the amount of data, the better the precision. In the future, reinforcing various data is expected to improve the effectiveness of camera-based fall detection models, and thus improve safety.

Experimental Study for DNA Fingerprint from Teeth of Charred Body (소사체 치아에서의 유전자지문 분석을 위한 실험적 연구)

  • Jong-Hoon Choi
    • Journal of Oral Medicine and Pain
    • /
    • v.21 no.2
    • /
    • pp.351-367
    • /
    • 1996
  • In the field Of individual identification in forensic Science, if the body is charred, it is sometimes impossible to identify the morphologic changes and charred tissue such as blood, muscle and bone can not be identified by forensic microbiologic method such as DNA typing. So the author used the characteristics of teeth which is relatively firm compare to other organs and stable to external environment such as heat and also possess cells needed for the DNA typing. The author conducted the experiment on teeth to detect DNA related to individual identification regarding to temperature in which other charredorgans can not be detected. The experiment was done on 64 extracted third molars consisted of unheated ones, and heated teeth to $100^{\circ}C$, $150^{\circ}C$, $200^{\circ}C$ for 45 min, 90 min, and 120 min respectively and to $250^{\circ}C$ for 45 min. DNA was extracted from each tooth and amplified fragment length polymorphism procedure(AMP-FLPs) using polymerase chain reaction(PCR) was applied and observed for the matching DNA in HumTH01 and HumCD4 locus and the followings Are the results : 1. It was able to detect matching DNA in HumTH01 and HumCD4 locus in every teeth which no heating has been done. 2. It was able to detect matching DNA in HumTH01 and HumCD4 locus in every teeth heated to $100^{\circ}C$ for 45, 90 and 120 min. 3. It was able to detect matching DNA in HumTH01 and HumCD4 locus in teeth heated to $l00^{\circ}C$, $200^{\circ}C$ for 45, 90, 120 min. 4. It was impossible to detect matching DNA in HumTH01 and HumCD4 locus in teeth heated to $250^{\circ}C$. So, it is possible to extract DNA from teeth that otherwise can not be extracted from other organs in the charred body and it can be concluded that teeth are highly reliable and applicatable as forensic odontology for individual identification.

  • PDF

NON-DESTRUCTIVE DETECTION FOR FOREIGN MATERIALS IN FOOD AND AGRICULTURAL PRODUCTS USING X-RAY SYSTEM

  • Morita, Kazuo;Tanaka, Shun'ichirou;Ogawa, Yukiharu
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.334-343
    • /
    • 1996
  • Quality evaluation for food and agricultural products have always been one of the most elusive problems associated with the handling , processing and marketing in a food plant production. In order to detect physical foreign materials in food and agricultural products, non-destructive techniques have been developed for many years. Application of X-ray system to detect physical foreign materials in food and agricultural products could be considered to be a high potential method. Especially , it is impossible to detect internal physical foreign materials by visual inspections. In this study, it was tried to be applied for two different X-ray devices. Soft X-ray system with CdTe sensor and X-ray CT scanner were evaluated for advantage of the detection of non-meltallic foreign materials in food and agricultural products . Though the soft X-ray is not a high energy radiation, it is possible to detect small different density in a material. The CdTe sensor has a high resolution for t e soft X-ray energy region. The density characteristics of foods and foreign material were expressed region. The density characteristics of foods and foreign materials were expressed as a soft X-ray energy spectrum. The energy spectrum was analyzed by a personal computer with a multi-channel analyzer. X-ray CT scanner can provide visual image and analyze by three dimensional information inside food and agricultural products. The X-ray CT scanner using as a medical equipment was used to detect a foreign material. The density characteristics of food and foreign materials in food were tried to be detected by the threshold value on the basis of the CT numbers. The soft X-ray absorption characteristics for acrylin plates and distilled water were obtained and could be found the possibility of detecting a small physical foreign materials such as a plastic wrapping film , a stone and grasshopper in food and agricultural products.

  • PDF

Comparison of Motion Sensor Systems for Gait Phase Detection (보행주기 검출용 모션 센서 시스템의 비교)

  • Park, Sun-Woo;Sohn, Ryang-Hee;Ryu, Ki-Hong;Kim, Young-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.2
    • /
    • pp.145-152
    • /
    • 2010
  • Gait phase detection is important for evaluating the recovery of gait ability in patients with paralysis, and for determining the stimulation timing in FES walking. In this study, three different motion sensors(tilt sensor, gyrosensor and accelerometer) were used to detect gait events(heel strike, HS; toe off, TO) and they were compared one another to determine the most applicable sensor for gait phase detection. Motion sensors were attached on the shank and heel of subjects. Gait phases determined by the characteristics of each sensor's signal were compared with those from FVA. Gait phase detections using three different motion sensors were valid, since they all have reliabilities more than 95%, when compared with FVA. HS and TO were determined by both FVA and motion sensor signals, and the accuracy of detecting HS and TO with motion sensors were assessed by the time differences between FVA and motion sensors. Results show of that the tilt sensor and the gyrosensor could detect gait phase more accurately in normal subjects. Vertical acceleration from the accelerometer could detect HS most accurately in hemiplegic patient group A. The gyrosensor could detect HS and TO most accurately in hemiplegic patient group A and B. Valid error ranges of HS and TO were determined by 3.9 % and 13.6 % in normal subjects, respectively. The detection of TO from all sensor signals was valid in both patient group A and B. However, the vertical acceleration detected HS validly in patient group A and the gyrosensor detected HS validly in patient group B. We could determine the most applicable motion sensors to detect gait phases in hemiplegic patients. However, since hemiplegic patients have much different gait patterns one another, further experimental studies using various simple motion sensors would be required to determine gait events in pathologic gaits.

Track-Before-Detect Algorithm for Multiple Target Detection (다수 표적 탐지를 위한 Track-Before-Detect 알고리듬 연구)

  • Won, Dae-Yeon;Shim, Sang-Wook;Kim, Keum-Seong;Tahk, Min-Jea;Seong, Kie-Jeong;Kim, Eung-Tai
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.9
    • /
    • pp.848-857
    • /
    • 2011
  • Vision-based collision avoidance system for air traffic management requires a excellent multiple target detection algorithm under low signal-to-noise ratio (SNR) levels. The track-before-detect (TBD) approaches have significant applications such as detection of small and dim targets from an image sequence. In this paper, two detection algorithms with the TBD approaches are proposed to satisfy the multiple target detection requirements. The first algorithm, based on a dynamic programming approach, is designed to classify multiple targets by using a k-means clustering algorithm. In the second approach, a hidden Markov model (HMM) is slightly modified for detecting multiple targets sequentially. Both of the proposed approaches are used in numerical simulations with variations in target appearance properties to provide satisfactory performance as multiple target detection methods.

Emergency Detection System using PDA based on Self-response Algorithm

  • Jeon, Ah-Young;Park, Jun-Mo;Jeon, Gye-Rok;Ye, Soo-Young;Kim, Jae-Hyung
    • Transactions on Electrical and Electronic Materials
    • /
    • v.8 no.6
    • /
    • pp.293-298
    • /
    • 2007
  • The aged are faced with increasing risk for falls. The aged have more fragile bones than others. When falls occur, it is important to detect this emergency state because such events often lead to more serious illness or even death. A implementation of PDA system, for detection of emergency situation, was developed using 3-axis accelerometer in this paper as follows. The signals were acquired from the 3-axis accelerometer, and then transmitted to the PDA through a Bluetooth module. This system can classify human activity, and also detect an emergency state like falls. When the fall occurs, the system generates the alarm on the PDA. If a subject does not respond to the alarm, the system determines whether the current situation is an emergency state or not, and then sends some information to the emergency center in the case of an urgent situation. Three different studies were conducted on 12 experimental subjects, with results indicating a good accuracy. The first study was performed to detect the posture change of human daily activity. The second study was performed to detect the correct direction of fall. The third study was conducted to check the classification of the daily physical activity. Each test lasted at least 1 min. in the third study. The output of the acceleration signal was compared and evaluated by changing various postures after attaching a 3-axis accelerometer module on the chest. The newly developed system has some important features such as portability, convenience and low cost. One of the main advantages of this system is that it is available at home healthcare environment. Another important feature lies in its low cost of manufacture. The implemented system can detect the fall accurately, so it will be widely used in emergency situations.

Three Predictive Tests Using Mice for the Identification of Contact Sensitizer

  • Jung-Hyun Shin;Min
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.22 no.2
    • /
    • pp.201-210
    • /
    • 1996
  • Predictive tests for the identification of contact sensitizing chemicals have been developed. We measured the sensitization potential with three predictive tests, the in vitro and the in vivo Local Lymph Node Assay(LLNA), ELISA to detect interferon-gamma(IFN-${\gamma}$) from supernatant and flow cytometry to detect change of cell surface proteins, using draining lymph nodes of mice. BALB/c mice were exposed to various chemicals or vehicles on the ears daily for 3 consecutive days in all experiments. With some exceptions of propyl paraben, neomycin sulfate, the in vivo LLNA was able to detect the sensitizing capacity of test chemicals and was more sensitive than the in vitro LLNA for chemicals used in the present study. In another experiment, contact sensitivity was assessed by the ELISA to detect IFN-Υ from the supernatants of the cultured LNCs after sensitization with chemicals. There was a good correlation between the LLNA and the IFN-Υ production for test chemicals. We also examined the change of cell surface proteins on LNCs after sensitization by flow cytometry for some cell adhesion molecules(ICAM-1, E-cadherine, B7 molecule), T cell markers(CD3, CD4, CD8, T$\alpha$$\beta$,T${\gamma}$$\delta$) and B cell markers(LR1, CD45R, I-Ad). The number of ICAM-1 positive cells and B cells in LNCs were increased after sensitization with DNCB, TNCB, isoeugenol and 25%, 50% cinnamic aldehyde compared with that of vehicle as a control. In conclusion, the in vivo LLNA could provide more sensitive screening test for moderate to strong sensitizers and some weak sensitizers including cosmetic raw materials than the in vitro LLNA. The production of IFN-Υ by allergen-activated LNCs might be a values indicators without radioisotopes for the identification of contact allergens. Detection of allergens by testing the increase of ICAM-1 positive cells and B cells in LNCs by flow cytometry might be used as a test method to detect allergens.

  • PDF

Analysis of Elastic Wave Based Leakage Detection Technology Using Accelerometers (가속도계를 이용한 탄성파 기반 누수탐지 기술 분석)

  • Choi, Kwangmook;Lee, Hohyun;Shin, Gangwook;Hong, Sungtaek
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.9
    • /
    • pp.1231-1240
    • /
    • 2020
  • Water pipes are laid on the ground, making it impossible to visually detect leaks due to aging of pipes, and technology to detect leaks in pipes is mainly used to detect leaks in pipes by detecting leaks. In this paper, two accelerometers were attached to both ends of the constant water piping to calculate the time difference between the acquired data to detect leakage points. The leak test of piping was performed by installing valves at 4.3m, 8.6m, and 12.9m points on piping 17.2m, and changing the development rate of valves to 30% and 70%. Leakage can be detected for pressure drop in piping, which is 30% and 70% open valve. It is very important to detect leakage in the early stage, and it is judged that detection of the initial leak point from the algorithm applied in this paper will be possible.

Sanghuangporus sanghuang extract inhibits the proliferation and invasion of lung cancer cells in vitro and in vivo

  • Weike Wang;Jiling Song;Na Lu;Jing Yan;Guanping Chen
    • Nutrition Research and Practice
    • /
    • v.17 no.6
    • /
    • pp.1070-1083
    • /
    • 2023
  • BACKGROUND/OBJECTIVES: Sanghuangporus sanghuang (SS) has various medicinal effects, including anti-inflammation and anticancer activities. Despite the extensive research on SS, its molecular mechanisms of action on lung cancer are unclear. This study examined the impact of an SS alcohol extract (SAE) on lung cancer using in vitro and in vivo models. MATERIALS/METHODS: Different concentrations of SAE were used to culture lung cancer cells (A549 and H1650). A cell counting kit-8 assay was used to detect the survival ability of A549 and H1650 cells. A scratch assay and transwell cell invasion assay were used to detect the migration rate and invasive ability of SAE. Western blot analysis was used to detect the expression of B-cell lymphoma-2 (Bcl-2), Bcl2-associated X (Bax), cyclin D1, cyclin-dependent kinases 4 (CDK4), signal transducer and activator of transcription 3 (STAT3), and phosphorylated STAT3 (p-STAT3). Lung cancer xenograft mice were used to detect the inhibiting ability of SAE in vivo. Hematoxylin and eosin staining and immunohistochemistry were used to detect the effect of SAE on the structural changes to the tumor and the expression of Bcl-2, Bax, cyclin D1, CDK4, STAT3, and p-STAT3 in lung cancer xenograft mice. RESULTS: SAE could inhibit lung cancer proliferation significantly in vitro and in vivo without cytotoxicity. SAE suppressed the viability, migration, and invasion of lung cancer cells in a dose and time-dependent manner. The SAE treatment significantly decreased the proapoptotic Bcl-2/Bax ratio and the expression of pro-proliferative proteins Cyclin D1 and CDK4 in vitro and in vivo. Furthermore, SAE also inhibited STAT3 expression. CONCLUSIONS: SAE reduced the cell viability and suppressed cell migration and invasion in human lung cancer cells. Moreover, SAE also exhibited anti-proliferation effects in vivo. Therefore, SAE may have benefits in cancer therapy.