• Title/Summary/Keyword: detailing

Search Result 262, Processing Time 0.024 seconds

Ethyl Silicate Bonded Alumina as a Ceramic Binder

  • N, Korobova;Dea-Wha, Soh
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.103-107
    • /
    • 2002
  • Ethyl silicate was used as organic binder for alumina refractories. In the present work only 15% of the water required for complete hydrolysis of ethyl silicate was initially added. The balance was provided from the atmosphere under controlled conditions of temperature and rh. The purpose of detailing the possible binder problem areas is more to indicate that the binder can have an effect on ceramic operations.

  • PDF

Limited Ductility Seismic Design in Moderate Seismicity Regions (중진지역에서의 한정연성도 내진설계)

  • 김재관
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1998.10a
    • /
    • pp.75-84
    • /
    • 1998
  • Korea is located in either low or moderate seismicity continental region. It is realized that design codes and underlying design concepts of high seismicity region may not be appropriate to low or moderate seismicity region. In this paper, test results on the seismic response of structures without seismic detailing are reexamined and compared with numerical analysis results. The seismic design concept based on limited ductility is proposed as an alternative seismic design approach in moderate seismicity regions.

  • PDF

Interventional Radiology Treatment for Postoperative Chylothorax

  • Jun, Hoyong;Hur, Saebeom
    • Journal of Chest Surgery
    • /
    • v.53 no.4
    • /
    • pp.200-204
    • /
    • 2020
  • Postoperative chylothorax is a rare occurrence after various thoracic surgical procedures, but it poses a substantial risk of morbidity and mortality. Thoracic duct embolization (TDE) is currently deemed the optimal treatment due to its safety and efficacy. This review offers an introduction to interventional options in this setting, detailing the steps of TDE for the edification of those engaged in postoperative care.

Seismic Upgrading of Multi-Span continuous Bridges using Shear Keys (전단키를 이용한 다경간 연속교의 내진성능 향상 방법)

  • 김재관
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.10a
    • /
    • pp.313-318
    • /
    • 1999
  • The seismic performance of multi-span bridge without seismic detailing is found to be insufficient in longitudinal direction. Shear keys and stoppers can be introduced as an alternative to enhance seismic capacity. The capacity curve of bridge with shear keys is obtained considering two extreme contact conditions of shear keys. Its curve is converted into ADRS spectra and compared with demand spectra. It is concluded that seismic performance can be improved effectively by shear keys and its performance can be evaluated graphically on the ADRS specta.

  • PDF

Study on the Application of FRACAS System for Rolling Stock (철도차량 FRACAS System 적용에 관한 연구)

  • Oh, Ji-Eun;Kang, Chan-Yong
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.487-497
    • /
    • 2008
  • This paper addresses the Fault Monitoring System developed by Hyundai-Rotem based on the Mil-HDBK-2155 Failure Reporting, Analysis and Corrective Action System. The purpose of a FRACAS is to provide a documented history of any problems, failures, their associated corrective actions as well as detailing how and why each problem arose or failure occurred during the Warranty Period for Rolling Stock delivered by Hyundai-Rotem. The Fault Monitoring System can assess the reliability, availability and maintainability as well as can predict no. of failure at a time which can input to Life Cycle Cost.

  • PDF

The Spiral - 66 Hudson Blvd Supertall

  • Smilow, Jeffery;Chan, Patrick
    • International Journal of High-Rise Buildings
    • /
    • v.11 no.1
    • /
    • pp.41-50
    • /
    • 2022
  • The Spiral, a supertall tower at the Hudson Yards Zoning District of NYC is an new iconic commercial office tower. The spiraling terraces throughout the height of the building creates unique outdoor spaces at each level for its occupants while introduces structural challenges unlike common office towers. Innovative structural solutions and an integrated connection design and steel detailing delivery process proved to be a key factor in the success of the project.

Seismic Behavior of Nonseismically Detailed Reinforced Concrete Beam-Column Joints (비내진 상세를 가진 RC 보-기둥 접합부의 지진 거동)

  • Woo, Sung-Woo;Lee, Han-Seon
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.6
    • /
    • pp.894-901
    • /
    • 2003
  • The objective of this study is to clarify the seismic capacity and the characteristics in the hysteretic behavior of RC structures with non-seismic detailing. Interior and exterior beam-column subassemblages were selected from a ten-story RC building and six 1/3-scale specimens were constructed with three variables; (1) with and without slab, (2) with and without hoop bars in the joint region, (3) upward and downward direction of anchorage for the bottom bar in beams of exterior beam-column subassemblage. The test results have shown; (1) in case of interior beam-column subassemblage, there is no almost difference between nonseismic and seismic details in the strength and ductility capacity; (2) the Korean practice of anchorage (downward and 25 $d_{b}$ anchorage length) in the exterior joint caused the 10%∼20% reduction of strength and 27% reduction of ductility in comparison with the case of seismic details; and the existence of hoop bars in the joint region shows no effect in shear strain.

Evaluation of Design Method and Shear Transfer Capacity on the Horizontal Interface of PC Composite Beams (PC 합성보의 수평접합면 전단력 전달성능 평가 및 설계법 분석)

  • Moon, Jeong-Ho;Oh, Young-Hun
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.1
    • /
    • pp.81-90
    • /
    • 2013
  • The purpose of this study is to evaluate the horizontal shear strength on the interface between PC and cast-in-place concrete for PC composite beams. Six specimens were tested to examine the structural performance of the horizontal interface with different surface condition and stirrup detailing. Except for SF-291B specimen failed in flexural compression, strengths and deformation capacities of five specimens were determined by horizontal shear failure. Horizontal shear strengths by composite horizontal shear or shear friction in current codes could be used to predict the horizontal shear capacity of the interface for specimens. Also detailing for stirrup by PCI design provision could be used to accomplish the composite action in the interface.

Behavior of Bellow Rectangular RC Piers without Seismic Detailing Subjected to Cyclic Lateral Load (수평 반복하중을 받는 비내진상세 RC 중공구형교각의 거동특성)

  • Kim, Jae-Kwan;Kim, Ick-Hyun;Lim, Hyun-Woo;Lee, Jae-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.2
    • /
    • pp.263-272
    • /
    • 2003
  • Scaled model tests were carried out to investigate a seismic behavior of reinforced concrete piers with hollow-rectangular section that were not detailed for seismic load. Additional lateral reinforcing bars were not provided that might be required for confinement against earthquake load. Two kinds of reinforcement details were considered for the longitudinal reinforcing bars: lap-spliced and continuous. In the lap-spliced model all longitudinal bars were lapped at the same height in a bottom plastic hinge zone. In the other model all longitudinal bars extended continuously throughout the height. The constructed models were subjected to quasi-static cyclic lateral loading in the presence of the constant vertical load. Limited ductile behavior was observed in the test of lap-spliced model and more ductile behavior was observed in the test of a continuous longitudinal reinforcement model.