• 제목/요약/키워드: design sources

검색결과 1,842건 처리시간 0.027초

제약회사의 판촉전략이 의약품 처방에 미치는 영향 (The Effects of Promotion Activities of Pharmaceutical Companies on Physicians' Prescription)

  • 박상준
    • 경영과학
    • /
    • 제28권2호
    • /
    • pp.93-103
    • /
    • 2011
  • This paper has aimed to identify marketing variables which affect physicians' prescription of drug. Based on a literature review this paper derives the three factors (indirect commercial source, direct commercial source, academic information source) of information sources that physicians rely on for medicines, the three factors (research supporting activity, marketing supporting activity, medicine information supporting activity) of promotion activities physicians prefer, and the four factors (indirect quality of medicine, direct quality of medicine, experience of using medicine, price and design of medicine) of prescription criteria physicians use. Then it investigates using canonical correlation analysis whether or not physicians' prescriptions are affected by the information sources, the promotion activities, and the type of physicians. From the canonical correlation analysis this paper derives the meaningful three canonical functions of prescription for drugs. The first function explains the prescription which is insensitive to marketing activities, the second function does the prescription which is sensitive to them, and the final function does the prescription which is not affected by them.

대형 Community 건물의 연료전지 구동 복합열원 하이브리드 히트펌프 시스템 성능에 관한 해석적 연구 (Study on the Performance of Fuel Cell Driven Compound Source Heat Pump System to a Large Community Building)

  • 정동화;변재기;최영돈;조성환
    • 신재생에너지
    • /
    • 제4권3호
    • /
    • pp.23-35
    • /
    • 2008
  • In the present study, performances of fuel cell driven compound source hybrid heat pump system applied to a large community building are simulated. Among several renewable energy sources, ground, river, sea, and waste water sources are chosen as available alternative energies. The performance and energy cost are varied with the hybrid heat pump sources. The system design and operation process appropriate for the surrounding circumstance guarantee the high benefit of the heat pump system applied to a large community building. Th system is driven by fuel cell system instead of the late-night electricity due to the advantages of the low energy cost and waste heat with high temperature.

  • PDF

A comparing on the use of Centrifugal Turbine and Tesla Turbine in an application of Organic Rankine Cycle

  • Thawichsri, Kosart;nilnont, Wanich
    • International Journal of Advanced Culture Technology
    • /
    • 제3권2호
    • /
    • pp.58-66
    • /
    • 2015
  • This paper aims to compare the use of Centrifugal Turbine and Tesla Turbine in an application of Organic Rankine Cycle (ORC) Machine using Isopentane as working fluid expanding. The working fluid has boiling point below boiling water and works in low-temperature sources between $80-120^{\circ}C$ which can be produced from waste heat, solar-thermal energy and geothermal energy etc. The experiment on ORC machine reveals that the suitability of high pressure pump for working fluid has result on the efficiency of work. In addition, Thermodynamics theory on P-h diagram also presented the effect of heat sources' temperature and flow rate on any work. Thus, the study and design on ORC machine has to concern mainly on pressure pump, flow rate and optimized temperature. Result experiment and calculate ORC Machine using centrifugal Turbine efficiency better than Tesla turbine 30% but Tesla Turbine is cheaper and easily structure. Further study on the machine can be developed throughout the county due to its low cost and efficiency.

한국형 고속전철(KHST) 실내소음 설계기준을 위한 주요 소음원의 허용소음도 (The allowable sound levels of major noise sources for the indoor-noise requirements of KHST)

  • 조국래;이우식
    • 한국철도학회논문집
    • /
    • 제4권1호
    • /
    • pp.9-15
    • /
    • 2001
  • It is required that the indoor-noise level of KHST (Korean High Speed Train) should be lower than 66 dB(A) at 300 km/h. In this study, the indoor-noise level of KHST has been predicted to determine the maximum allowable sound power levels of major noise sources. It is found that the indoor-noise requirements for KHST can be met by increasing the transmission losses of the floor and side-wall structures as well as by lowering the sound power levels of the major noise sources.

  • PDF

Dynamic Paralleling Behaviors of High Power Trench and Fieldstop IGBTs

  • Wu, Yu;Sun, Yaojie;Lin, Yandan
    • Journal of Power Electronics
    • /
    • 제14권4호
    • /
    • pp.788-795
    • /
    • 2014
  • This paper demonstrates the dynamic behaviors of paralleled high power IGBTs using trench and fieldstop technologies. Four IGBTs are paralleled and standard deviation is adopted to represent the imbalance. Experiments are conducted under three different operation conditions and at different temperatures ranging from $-25^{\circ}C$ to $125^{\circ}C$. The experimental results show that operation at very low and very high temperatures usually aggravates the switching behaviors. There is a trade-off between the balance and the losses at low temperatures. These results can help in the design of heat sinks in paralleling applications confronting very low temperatures.

매입형 영구자석 전동기의 열 등가 회로 해석 (Thermal Network Analysis of Interior Permanent Magnet Machine)

  • 임재원;서장호;이상엽;정현교
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집 특별세미나,특별/일반세션
    • /
    • pp.527-532
    • /
    • 2009
  • Recently, Interior Permanent Magnet Machine(IPM) is widely used for traction motor in the high speed train. Due to the high efficiency and high power density of the IPM, it has lots of heat sources such as iron loss and copper loss. These heat sources can cause the demagnetization of permanent magnet, losses in output power and even irreversible defect of the IPM. To prevent the power loss caused by heat sources, the accurate thermal analysis has to be carried out. For the thermal analysis of the IPM, the thermal network is designed for this traction motor. The thermal analysis has executed at rated speed operation. The result of thermal network analysis can be used for the IPM design process.

  • PDF

열원의 대칭 배열에 따른 압출형 히트싱크의 방열성능 연구 (Effects of Symmetrically Arranged Heat Sources on the Heat Release Performance of Extruded-Type Heat Sinks)

  • 구민예;신헌충;이교우
    • 대한기계학회논문집B
    • /
    • 제40권2호
    • /
    • pp.119-126
    • /
    • 2016
  • 본 연구는 실험적인 방법과 열유동 해석 방법을 사용하여 대용량 압출형 히트싱크의 방열성능에 미치는 열원 대칭배열의 영향을 고찰하고, 이를 바탕으로 제조원가가 낮은 고효율의 히트싱크를 제안하고자 한다. 실험결과를 통해서 유사한 유효 유동단면적을 가지는 경우에 히트싱크의 전열면적이 방열성능에 큰 영향을 줌을 확인할 수 있었으며, 히트싱크의 양면 모두를 이용하는 방열이 훨씬 효과적인 방열이 가능함을 알 수 있었다. 또한, 대칭으로 열원을 배치한 경우가 비대칭 배치보다 효율적으로 방열됨을 알 수 있었다. 해석연구의 결과를 통해서는 실험결과와 정성적으로는 유사한 경향을 확인할 수 있었으며, 실험연구에서 확인하지 못한 질량유량별 및 투입열량별 추이, 단면과 양면 사용의 정량적 비교 등이 가능하였다.

히트싱크 베이스의 두께 변화가 방열성능에 미치는 영향 (Effect of the variation of base thickness on the heat release performance of the heat sink)

  • 김정현;이교우
    • 한국산학기술학회논문지
    • /
    • 제15권8호
    • /
    • pp.4749-4755
    • /
    • 2014
  • 본 연구는 고용량 인버터 등의 열 발생 환경에서 히트싱크의 방열성능을 극대화하기 위한 파라미터 연구의 일환으로 히트싱크 베이스 두께 변화에 대한 방열성능 변화를 조사하였다. 베이스 두께가 각각 5, 9.5 및 14 mm인 히트싱크의 방열성능을 히트싱크 베이스의 윗면 중앙 온도, 히트싱크를 통한 방열량 및 열원부의 온도 등의 세 가지 지표의 비교를 통하여 고찰하였다. 실험연구와 전산유체역학 프로그램을 이용한 해석연구를 병행하여 베이스 두께 변화에 따른 각 방열 성능 지표에 변화가 있음을 확인하였다. 베이스의 윗면 중앙 온도와 방열율은 베이스의 두께가 얇을수록 향상되는 효과를 보였고, 베이스 열원부의 온도는 베이스의 두께가 두꺼울수록 낮아지는 경향을 보였다. 성능 지표의 비교 고찰을 통해 연구에 사용된 세 히트싱크 내에서는 베이스의 두께가 9.5 mm인 히트싱크에서 최적점이 나타났다. 따라서 제한적이지만 본 연구결과 내에서는 9.5 mm 두께의 베이스를 가지는 히트싱크가 최적의 방열 성능을 보이는 것으로 판단되었다.

자동차 기능안전 표준을 반영하는 개선된 FTA 및 위험원 분석 기법 (An Improved Method of FTA and Associated Risk Analysis Reflecting Automotive Functional Safety Standard)

  • 정호전;이재천
    • 한국산학기술학회논문지
    • /
    • 제18권9호
    • /
    • pp.9-17
    • /
    • 2017
  • 자동차 및 철도 등 수송 시스템에서 무인화 운전으로의 진전으로 인해 시스템 운영 시 안전성의 확보는 필수불가결한 요소로 간주되어 왔다. 자동차 안전설계를 뒷받침하기 위해 제정된 기능안전 표준인 ISO 26262에서는 위험원 분석 및 평가 그리고 안전 설계를 수행할 때 시스템 설계 정보를 적절하게 반영함으로써 안전성이 확보되는 자동차 시스템을 구현하기 위한 절차가 제시되어 있다. 이에 따라 위험원 분석에 관해 많은 연구가 이루어졌는데, 주로 이미 운영되고 있는 유사 시스템 사례에 의존하여 설계 정보를 활용하였다. 먼저 물리 구성품 수준에서 설계정보를 추출하고, 이로부터 기능 들을 역추적 한 후에 위험원을 식별하는 방법이 연구되었다. 이러한 방법은 빠르고 쉽게 위험원의 식별이 가능하기는 하지만, 설계 요구사항이 변경되거나 새로운 시스템을 설계할 때에는 설계 정보를 제대로 반영할 수 없어 일부 위험원이 누락될 수 있는 가능성이 있다. 이러한 점을 해결하기 위해서 본 논문에서는 기능안전표준에서 제시하는 안전수명주기 모델의 위험원 분석 단계에서 효과적인 방법을 연구하였다. 구체적으로 시스템 개념 설계를 Top-Down 방식으로 수행하면서 확보한 설계 정보를 위험원 분석에 적절하게 활용하는 방법을 제안하였다. 먼저 시스템 개념 설계를 수행하고, 획득된 기능 설계 결과를 분석하였다. 그러고 나서 기능 분석 결과를 활용하는 기능기반 Fault Tree Analysis 방법을 제시하고 위험원 분석을 수행하였다. 또한 자동차 시스템에서의 안전 설계 사례 연구를 통하여 본 논문에서 제시하는 방법이 대상 시스템의 설계 정보가 체계적으로 반영되어 누락 가능성이 줄어든 위험원 분석이 가능함을 보여 주었다.

AMINO ACID DIGESTIBILITY AS AFFECTED BY VARIOUS FIBER SOURCES AND LEVELS 1. DIFFERENCE BETWEEN ILEAL AND FECAL DIGESTIBILITY OF AMINO ACIDS

  • Nongyao, A.;Han, In K.;Choi, Yun J.;Lee, N.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제3권4호
    • /
    • pp.347-351
    • /
    • 1990
  • A simple cross-over design was used in digestion experiment carried out on finishing pig (70 kg body wt.) fitted with ileal T-cannula, to determine the difference between ileal and fecal digestible values as affected by various fiber sources and levels. The series of semi-purified diets were formulated in an attempt to meet 1, 3, 7 and 9% crude fiber level, with alfalfa meal (AFM), rubber seed meal (RSM), leucaena meal (LM) and cellulose. Both the levels and sources influenced the amino acid digestibilities, as increasing crude fiber level the digestibilities increased. The digestibilities of amino acids at ileal level were higher than at fecal level. The magnitude of response were ranged from 1.76 to 8.41 percentage unit or 4.86 by average. The dry matter digestibilities of the diets reflect the digestibilities of amino acids as accumulation of fiber would increase endogenous losses. It indicates that the digestibilities of amino acids varied irregularly among diets, probably depended on a dietary nutrient and individual fiber fraction contents.