• Title/Summary/Keyword: derivatization

Search Result 296, Processing Time 0.062 seconds

Chiral Purity Test of Metoprolol Enantiomer After Derivatization with (-)-Menthyl Chloroformate by Reversed-Phase High Performance Liquid Chromatography

  • Kim, Kyeong-Ho;Choi, Pok-Wha;Hong, Seon-Pyo;Kim, Hyun-Ju
    • Archives of Pharmacal Research
    • /
    • v.22 no.6
    • /
    • pp.614-618
    • /
    • 1999
  • A reversed-phase high-performace liquid chromatographic method was developed to determine the optical purity of metoprolol enantiomers. The enantiomers were converted to diastereomeric derivatives using (-)-menthyl chloroformate reagent. Separation of the enantiomers as diastereomers was achieved by reversed-phase HPLC within 30 min using Inertsil C8 column. This method allowed determination of 0.05% of either enantiomer in the presence of its stereoisomer and method validation showed adequate linearity over the required range. Owing to the reaction condition during the derivatization with (-)-menthyl chloroformate, the possibility of racemization had to be established. Different ratios of (S)-(-)-metoprolol and (R)-(+)-metoprolol were prepared. Enantiomeric separation of these mixtures took place on a chiralcel OD column or, after derivatization with (-)-menthyl chloroformate, on a C8 column. The results form the these two independent separation systems were compared with trace racemization and were in very good agreement. No racemization was found during the experiment.

  • PDF

The preliminary evaluation of semi-quantitative analysis by in situ pre-chromatographic derivatization of amines and image analysis in TLC (TLC상 분리 전 직접적 유도체화 반응과 이미지 분석을 통한 아민 화합물의 반정량분석을 위한 선행평가)

  • Kim, Younsu;Choi, Sung-Woon
    • Analytical Science and Technology
    • /
    • v.28 no.2
    • /
    • pp.79-85
    • /
    • 2015
  • A preliminary experiment was performed to develop a fast, convenient, and economical semi-quantitative method of analyzing amphetamine-like amines from images of derivatives. These were generated from the reaction (in situ, co-spot) of three amphetamine-like compounds with three derivatization reagents on a TLC plate. The attempt was made to optimize the reaction conditions for an efficient derivatization reaction, and TLC images taken by a digital camera were analyzed using two types of image analysis program (CP Atlas 2.0 and ImageJ) for repeatability (RSD, %) and linearity (R2). Then, their results were compared. For efficient derivatization, the reaction conditions needed to be modified. The results of image analysis of each of the samples at two different concentrations (0.5 mg/mL and 0.01 mg/mL) showed that the RSD values for reaction repeatability were in the range of 0.69-5.50%. From the calibration curves between the area of the derivative and the concentration of amines, the R2 values (R2 > 0.9906) for good linear correlation were found to be high, in a concentration range of 0.1-0.005 mg/mL of amines. In addition, the two programs demonstrated little difference in the analysis of repeatability and linearity of the derivatization, so that the current method has the potential to be used for the semi-quantitative analysis of amines.

Sensitive Determination of Alkylphenols, Chlorophenols, and Bisphenol A using GC/MS-SIM in Papers Materials

  • Kim, Hyub;Kim, Jin-Ho;Kim, Yong-Hwa
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.120.2-121
    • /
    • 2003
  • The alkylphenols, chlorophenols and bisphenol A were determined by gas chromatography/mass spectrometry-selected ion monitoring (GC/MS-SIM) mode followed by two work-up methods for comparison; isoBOC derivatization method and TBDMS derivatization method. Eleven phenols in paper samples were extracted with acetonitrile. (omitted)

  • PDF

Comparison of isoBOC derivatives, TBDMS derivatives, with US EPA Method in the sensitivity of Alkylphenols, Chlorophenols, and Bisphenol A potential field-screening applications of GC/MS-SIM

  • Kim, Hyub;Hong, Jong-Ki;Kim, Yong-Hwa;Kim, Kyoung-Rae
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.235.2-236
    • /
    • 2002
  • The alkylphenols, chlorophenols and bisphenol A were determined by gas chromatography/mass spectrometry-selected ion monitoring mode followed by three work-up methods for comparison: EPA method, isoBOC derivatization method and TBDMS derivatization method. Eleven phenols in water samples were extracted with dichloromethane. (omitted)

  • PDF

Dertermination of Alkylphenols, Chlorophenols and Bisphenol A in Various Samples by Freezing Filtration and GC/MS-SIM

  • Kim, Hyub
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.68.1-68.1
    • /
    • 2003
  • A method for determination 11 endocrine disrupting chemicals of phenols in various samples was deloped. The alkylphenols, chlorophenols and bisphenol A were determined by gas chromatography/mass spectrometry-selected ion monitoring (GC/MS-SIM) followed by two work-up methods for comparison; isobutoxycarbonyl (isoBOC) derivatization method and tert-butyldimethylsilyl (TBDMS) derivatization method. Eleven endocrine disrupting chemicals (EDCs) of phenols in biological samples were extracted with acetonitrile and then acetonitrile layer was refrigerated at -60$^{\circ}C$ for 2 hours (freezing filtration). (omitted)

  • PDF

Study on the quantitation of moxidectin by fluoroscence derivatization and it's residual after subcutaneously injection in pigs (형광유도체화법을 이용한 Moxidectin 정량 및 피하주사 후 돼지에서의 잔류 연구)

  • Jang, Beom-su;Lim, Jong-hwan;Park, Byung-kwon;Kim, Min-Kyu;Yun, Hyo-in
    • Korean Journal of Veterinary Research
    • /
    • v.44 no.1
    • /
    • pp.23-28
    • /
    • 2004
  • We established a new method to analyze moxidectin using high performance liquid chromatography(HPLC) with fluorescence derivatization in order to obtain its residual profiles in biological samples. Recovery of moxidectin in tissue was 62% at 10 ppb. Average detection reproducibility in terms of coefficience variation was 4.47% at 0.32 to 10 ppb. Residual of moxidectin was studied in 44 Yorkshire-Landrace mixed bred male pigs administered subcutaneously 0, 200, or $800{\mu}g/kg$ body weight (BW) Residual profiles of moxdectin in blood, muscle, liver, kidney and fat of pigs were described. The concentration of the moxidectin in liver after administration of moxidectin was the highest among the tissues examined. Moxidectin in liver after administration of moxidectin as $200{\mu}g/kg$ BW was declined from $10.0{\pm}3.7ng/g$ at 10 day post administration to $0.5{\pm}0.3ng/g$ level at 40 day post administration. Residual levels of moxidectin in all samples were estimated to fall below the limit of quantitation (0.32 ng/ml) after 50 day after treatment of $200{\mu}g/kg$. Moxidectin showed no abnormal observations in all the clinical findings at any concentrations under these experimental conditions. In conclusion, this analysis method by HPLC after fluorescence derivatization was very effective for the detection of moxidectin in biological samples. We suggest that 50-day is safe enough for the withdrawal time of moxidectin in pigs, following the recommendation dose by the manufacturer.

Development and validation of a qualitative GC-MS method for THCCOOH in urine using injection-port derivatization

  • Sim, Yeong Eun;Kim, Ji Woo;Kim, Jin Young
    • Analytical Science and Technology
    • /
    • v.34 no.2
    • /
    • pp.68-77
    • /
    • 2021
  • Cannabis is one of the most abused drugs in Korea. The main psychoactive component in cannabis, Δ9-tetrahydrocannabinol, is metabolized to 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THCCOOH) and THCCOOH-glucuronide (THCCOOH-glu) in the human liver, whereby the amount of THCCOOH-glu found in urine is twice as high as that of THCCOOH. The analytical process adapted by the majority of urine drug-testing programs involves a two-step method consisting of an initial immunoassay-based screening test followed by a confirmatory test if the screening test result is positive. In this study, a qualitative gas chromatography-mass spectrometry (GC-MS) method was developed and validated for the detection of THCCOOH in human urine, where THCCOOH-glu was converted into THCCOOH by alkaline hydrolysis. For purification of the urine extract prior to instrumental analysis, high-speed centrifugation was used to minimize interference. In addition, an injection-port derivatization method using ethyl acetate and N,O-bis(trimethylsilyl)-trifluoroacetamide containing 1 % trimethylchlorosilane was employed to reduce the time required for derivatization, and an aliquot of the final solution was injected into the GC-MS. The method was validated by measuring the selectivity, limit of detection (LOD), and repeatability. The sensitivity, specificity, precision, accuracy, Kappa, F-measure, false positive, and false negative rate were determined by comparing the GC-MS results with those obtained using the immunoassay. The LOD was determined to be 0.32 ng/mL, while the repeatability was within 9.1 % for THCCOOH. Furthermore, a comparison study was carried out, whereby the screening immunoassay exhibited a sensitivity of 86.4 % and a specificity of 100 % compared to GC-MS. The applicability of the developed method was examined by analyzing spiked urine and forensic urine samples obtained from suspected cannabis abusers (n = 221).

Fast Determination of Multiple-Reaction Intermediates for Long-Chain Dicarboxylic Acid Biotransformation by Gas Chromatography-Flame Ionization Detector

  • Cho, Yong-Han;Lee, Hye-Jin;Lee, Jung-Eun;Kim, Soo-Jung;Park, Kyungmoon;Lee, Do Yup;Park, Yong-Cheol
    • Journal of Microbiology and Biotechnology
    • /
    • v.25 no.5
    • /
    • pp.704-708
    • /
    • 2015
  • For the analysis of multiple-reaction intermediates for long-chain dicarboxylic acid biotransformation, simple and reproducible methods of extraction and derivatization were developed on the basis of gas chromatography with flame ionization detector (GC-FID) instead of mass spectrometry. In the derivatization step, change of the ratio of pyridine to MSTFA from 1:3 to 9:1 resulted in higher peak intensity (p = 0.021) and reproducibility (0.6%CV) when analyzing 32 g/l ricinoleic acid (RA). Extraction of RA and ω-hydroxyundec-9-enoic acid with water containing 100 mM Tween 80 showed 90.4-99.9% relative extraction efficiency and 2-7%CV compared with those with hydrophobic ethyl acetate. In conclusion, reduction of the pyridine content and change of the extraction solvent to water with Tween 80 provided compatible derivatization and extraction methods to GC-FID-based analysis of longchain carboxylic acids.

Determination of Volatile Fatty Acids in Aqueous Samples by HS-SPME with In-Fiber Derivatization (Fiber내 유도체화/HS-SPME를 이용한 수용액 시료 중 휘발성 지방산의 분석)

  • Ahn, Yun Gyong;Lee, Jee Yeon;Kim, Jeehyeong;Hong, Jongki
    • Analytical Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.458-465
    • /
    • 2003
  • The HS (headspace)-SPME (Solid phase microextraction) as rapid and simple method was performed for the determination of volatile fatty acids (VFAs) from the aqueous samples. In-fiber derivatization of VFAs with 1-Pyrenyldiazomethane (PDAM) was applied to improve their sensitivity of detection. In SPME procedure, typical parameters such as effects of solution pH, and salting out reagent and ultrasonication were investigated to improve the extraction efficiency. Based on the developed method, VFAs in wastewater samples were determined by gas chromatography / mass spectrometry-selected ion monitoring (GC/MS-SIM) mode.