• 제목/요약/키워드: derivatization

검색결과 297건 처리시간 0.035초

Part-Per-Trillion level determination of Alkylphenols, Chlorophenols and Bisphenol A using GC/MS-SIM in Tap Water

  • Kim, Hyub
    • 한국환경독성학회:학술대회논문집
    • /
    • 한국환경독성학회 2003년도 추계국제학술대회
    • /
    • pp.149-149
    • /
    • 2003
  • A new technique is proposed for the determination of alkylphenols, chlorophenols and bisphenol A in tap water. The sample preparation consists of a solid phase extraction (SPE) of alkylphenols, chlorophenols and bisphenol A from a water sample with XAD-4 and subsequent conversion to isobutyloxycarbonyl (isoBOC) derivatives or tert.-butyldimethylsilyl (TBDMS) derivatives for sensitive analysis with the GC/MS-SIM mode. The recoveries were 86.6∼105.2 % (isoBOC derivatization) and 97.6∼484.5 % (TBDMS derivatization), respectively. The limit of quantitation of alkylphenols, chlorophenols and bisphenol A for SIM were 0.001∼0.050 $\mu\textrm{g}$/l (isoBOC derivatization) and 0.003∼0.050 $\mu\textrm{g}$/l (TBDMS derivatization). The SIM responses were linear with the correlation coefficient varying 0.9755∼0.9981 (isoBOC derivatization), and 0.9908∼0.9996 (TBDMS derivatization). The derivative methods and their application to tap water samples will be disscussed.

  • PDF

Chiral Separation of ${\beta}-Blockers$ after Derivatization with a New Chiral Derivatization Agent, GATC

  • Ko, Mi-Young;Shin, Dae-Hong;Oh, Joung-Weon;Asegahegn, Workaferhaw Shibru;Kim, Kyeong-Ho
    • Archives of Pharmacal Research
    • /
    • 제29권11호
    • /
    • pp.1061-1065
    • /
    • 2006
  • A new chiral derivatization agent with sugar moiety, 2,3,4,6-tetra-O-acetyl-${\beta}$-D-galactopyranosyl isothiocyanate (GATC) was synthesized. Several ${\beta}-blockers$ were investigated for the possible separation of the enantiomers by reversed-phase HPLC after derivatization with this new chiral derivatization agent (GATC). GATC was reacted readily with ${\beta}-blockers$ at room temperature and the reaction mixture could directly be injected into the HPLC system. The corresponding diastereomers were well resolved on an ODS column with acetonitrile-ammonium acetate buffer as a mobile phase and monitored at UV 254 nm. The optimization of the derivatization procedure (concentration of GATC, reaction temperature and time) and HPLC conditions (pH and ionic strength of mobile phase) were investigated and compared with GITC.

Chiral separation of $\beta$-agonists after derivatization with a new chiral derivatization agent, GATC

  • Min, Kyeong-Il;Ko, Mi-Young;Kim, Kyeong-Ho
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2003년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.1
    • /
    • pp.275.2-276
    • /
    • 2003
  • Several ${\beta}$-agonists were investigated for the possible separation of the enantiomers by reversed-phase high-performance liquid chromatography after derivatization with a new chiral derivatization agent, GATC. The derivatization proceeded quantitatively within 1 h at room temperature. The corresponding diastereomers were well resolved an ODS column with acetonitrile-acetate buffers a mobile phase and monitored at UV 254nm. (omitted)

  • PDF

기체 크로마토그래피/질량분석기를 이용한 종이류 중 알킬페놀류, 클로로페놀류 및 비스페놀 A 정량 (Sensitive Determination of Alkylphenols, Chlorophenols, and Bisphenol A using GC/MS-SIM in Paper Materials)

  • 김협;김진호
    • Environmental Analysis Health and Toxicology
    • /
    • 제18권1호
    • /
    • pp.45-55
    • /
    • 2003
  • The alkylphenols, chlorophenols and bisphenol A were determined by gas chromatography/mass spectrom-etry-selected ion monitoring (GC/MS-SIM) mode followed by two work-up methods for comparison; isoBOC derivatization method and TBDMS derivatization method. Eleven phenols in paper samples were extracted with acetonitrile. Also, solid -phase extraction (SPE) with XAD -4 and subsequent conversion to isobutoxycarbonyl derivatives or tert.-butyldimethylsilyl derivatives for sensitive analysis with the selected ion-monitoring (SIM) mode. The SIM responses were linear with the correlation coefficient varying 0.9717 ∼ 0.9995 (isoBOC derivatization), and 0.9842 ∼ 0.9980 (TBDMS derivatization). The recoveries were 82.4 ∼ 108.8%) by area ratio of phenanthrene -d$\_$10/ vs bisphenol A-d$\^$l6/. (isoBOC derivatization and TBDMS derivatization) The range of concentrations was respectively, 0.95 ∼ 1.44 ng/g in 2,4-dichlorophenol, 1.01 ∼ 1.17 ng/g in t-butylphenol,2.17 ∼ 5.84 ng/g in pentachlorophenol, 12.68 ∼ 14.88 ng/g in nonylphenol and 30.84 ∼ 153.72 ng/g in bisphenol A.

GC/MS-SIM 방법에 의한 수돗물 중 알킬페놀, 플로로페놀과 비스페놀 A의 ppt 정량 (Part-Per-Trillion Level Determination of Alkylphenols, Chlorophenols and Bisphenol A using GC/MS-SIM in Tap Water Samples)

  • 김협
    • Environmental Analysis Health and Toxicology
    • /
    • 제18권3호
    • /
    • pp.199-208
    • /
    • 2003
  • A new technique was proposed for the determination of alkylphenols, chlorophenols and bisphenol A in tap water samples. The sample preparation consists of a solid phase extraction (SPE) of alkylphenols, chlorophenols and bisphenol A from a water sample with XAD-4 and subsequent conversion to isobutyloxycarbonyl (isoBOC) derivatives or tert-butyldimethylsilyl (TBDMS) derivatives for sensitive analysis with the CC/MS SIM mode. The recoveries were 86.6 ∼ 105.2% (isoBOC derivatization) and 97.6∼484.5% (TBDMS derivatization), respectively. The limit of quantitation of alkylphenols, chlorophenols and bisphenol h for SIM were 0.001∼0.050 $\mu\textrm{g}$/1 (isoBOC derivatization) and 0.003∼0.050 $\mu\textrm{g}$/1 (TBDMS derivatization). The SIM responses were linear with the correlation coefficient varying 0.9755∼0.9981 (isoBOC derivatization), and 0.9908∼0.9996 (TBDMS derivatization). When these methods were applied to tap water samples, the range of concentrations were 22.8∼31.3 ng/1 in 2,4-dichlorophenol, 28.6∼70.3 ng/1 in pentachlorophenol, 15.2∼17.4 ng/1 in t-butylphenol, 10.8∼13.2 ng/1 in t-octylphenol and 17.6∼36.3 ng/l in bisphenol A, respectively.

Reversed-Phase High Performance and Liquid Chromatographic Separation of the Enantiomers of Terbutaline by Derivatization with 2,3,4-Tetra-o-acetyl-\beta-glucopyranosyl Isothiocyanate

  • Kim, Kyeong-Ho;Kim, Dong-Sig;Hong, Seon-Pyo;Keon, Oh-Seung
    • Archives of Pharmacal Research
    • /
    • 제23권1호
    • /
    • pp.26-30
    • /
    • 2000
  • The enantiomers of the bronchodilator terbutaline were separated by reversed-phase high performance liquid chromatograhy after derivatization with 2,3,4,6-tetra-O-acetyl-\beta-D-glucopyranosyl isothiocyanate(GITC) reagent. The derivatization proceeded quantitatively within 1 h at room temperature. The corresponding diastereomeric thiourea derivatives were well resolved on an ODS column with acetonitrile-acetate buffer as a mobile phase. Elution orders of the diastereomers were confirmed by derivatization of R-(-)-terbutaline and S-(+)-terbutaline which were collected by semi-preparative chiral HPLC using Sumichiral OA-4700 column. The native fluorescence of terbutaline was quenched by derivatization with GITC. The detection limit was 25ng when monitored at UV 278 nm.

  • PDF

GC/MS-SIM for the Determination of Alkylphenols, Chlorophenols and Bisphenol A in Paper Materials

  • Kim, Hyub
    • 한국환경독성학회:학술대회논문집
    • /
    • 한국환경독성학회 2003년도 춘계학술대회
    • /
    • pp.145-145
    • /
    • 2003
  • A method for the determination of alkylphenols, chlorophenols and bisphenol A in paper materials using GC/MS-SIM has been developed. Eleven endocrine disrupting chemicals (EDCs) of phenols in paper samples were extracted with acetonitrile. Also, solid-phase extraction (SPE) with XAD-4 and subsequent conversion to isobutoxycarbonyl derivatives or tert.-butyldimethylsilyl derivatives for sensitive analysis with the selected ion-monitoring (SIM) mode. The recoveries were 82.4∼108.8 % by area ratio of pheranthrene-d$\sub$10/ vs bisphenol A d$\sub$l6/. (isoBOC derivatization and TBDMS derivatization) The SIM responses were linear with the correlation coefficient varying 0.9717∼0.9995 (isoBOC derivatization), and 0.9842∼0.9980 (TBDMS derivatization). The range of concentrations was respectively, 0.95∼l.44 ng/g in 2,4-dichlorophenol, 1.01∼1.17 ng/g in t-butylphenol, 2.17∼5.84 ng/g in pentachlorophenol, 12.68∼14.88 ng/g in nonylphenol and 30.84∼153.72 ng/g in bisphenol A.

  • PDF

Chemical Derivatization of Catecholamines for Gas Chromatography-Mass Spectrometry

  • Park, Sun-Young;Kang, Bo-Xin;Li, Quing;Kim, Hoon-Sik;Lee, Jun-Gae;Hong, Jong-Ki
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권7호
    • /
    • pp.1497-1504
    • /
    • 2009
  • GC/MS analysis of catecholamines (CAs) in biological sample may produce poor reproducible quantitaion when chemical derivatization is used as the technique to form a volatile derivative. Significant quantities of the side products can be formed from CAs with primary amine during the derivatization reaction under un-optimized conditions. We have tested various chemical derivatization techniques in an attempt to find an optimum derivatization method that will reduce side product formation, enable to separate several catecholamine derivatives in GC chromatogram, and obtain significant improvement of detection sensitivity in GC/MS analysis. Whereas several derivatization techniques such as trimethylsilylation (TMS), trifluoroacylation (TFA), and two step derivatization methods were active, selective derivatization to form O-TMS, N-heptafluorobutylacyl (HFBA) derivative using N-methyl-N-(trimethylsilyl)-trifluoroacetamide (MSTFA) and N-methyl-bis(heptafluorobutyramide) (MBHFBA) reagents was found to be the most effective method. Moreover, this derivative formed by selective derivatization could provide sufficient sensitivity and peak separation as well as produce higher mass ion as base peak to use selected ion in SIM mode. Calibration curves based on the use of an isotopically labeled internal standard show good linearity over the range assayed, 1 ~ 5000 ng/mL, with correlation coefficients of > 0.996. The detection limits of the method ranged from 0.2 to 5.0 ppb for the different CAs studied. The developed method will be applied to the analysis of various CAs in biological sample, combined with appropriate sample pretreatment.

Determination of 11 Phenolic Endocrine Disruptors using Gas Chromatography/Mass Spectrometry-Selected Ion Monitoring in Five Selected Wastewater Influents

  • Kim, Hyub
    • Environmental Engineering Research
    • /
    • 제13권4호
    • /
    • pp.216-223
    • /
    • 2008
  • An efficient method for the simultaneous determination of eleven phenolic endocrine-disrupting chemicals (EDCs) present in wastewater influent samples was described. The 11 phenolic EDCs including alkylphenols, chlorophenols, and bisphenol A were determined by gas chromatography/mass spectrometry-selected ion monitoring (GC/MS-SIM) following two work-up methods for comparison; isobutoxycarbonyl (isoBOC) derivatization and tert-butyldimethylsilyl (TBDMS) derivatization. The wastewater influent samples containing the 11 EDCs were adjusted to pH 2 with $H_2SO_4$ and then cleaned up with n-hexane. Next, they were subjected to solid-phase extraction (SPE) with XAD-4 resin and subsequently converted to isoBOC or TBDMS derivatives for sensitivity analysis with gas chromatography/mass spectrometry-selected ion monitoring (GC/MSSIM). Following isoBOC derivatization and TBDMS derivatization, the recoveries were 86.6-105.2% and 97.6-142.7%, the limits of quantitation (LOQ) for the 11 phenolic EDCs for SIM was 0.001-0.050 ng/mL and 0.003-0.050 ng/mL, and the SIM responses were linear with the correlation coefficient varying by 0.9717-0.9995 and 0.9842-0.9980, respectively. When these methods were applied to five selected wastewater influent samples, for isoBOC derivatization and TBDMS derivatization the ranges of concentration detected were 0.2-99.6 ng/mL and 0.4-147.4 ng/mL, respectively.

HPLC와 Fluorescence Derivatization 기법을 이용한 극미량 NDMA의 수질분석 (Trace-level Determination of N-nitrosodimethylamine(NDMA) in Water Samples using a High-Performance Liquid Chromatography with Fluorescence Derivatization)

  • 차우석;;;최희철
    • 대한환경공학회지
    • /
    • 제28권2호
    • /
    • pp.223-228
    • /
    • 2006
  • 본 연구에서는 fluorescence derivatization 기법과 HPLC를 이용하여 수중에 nanograms per liter로 존재하는 극미량 N-nitrosodimethylamine(NDMA)를 분석하고자 하였다. 이를 위해 먼저 다양한 조건 하에서의 fluorescence intensity를 측정함으로써 derivatization 기법을 최적화하였는데, fluorescence detector의 excitation/emission wavelength는 340 nm(excitation)과 530 nm(emission)에서, denitrosation 후 용액의 pH는 9-12의 범위에서, 그리고 dansyl chloride의 농도는 330-500 mg/L 범위에서, 최대 fluorescence intensity를 보여주였다. 용매추출을 통한 수질 시료의 분석에서, 표준농도와 검출농도의 차이는, 저농도(10-200 ng/L) 범위에서 12-162%, 고농도(100-1000 ng/L) 범위에서 6-23%를 보여, 저농도 범위에서 더 많은 차이가 나는 것으로 나타났으나, 두 농도 범위 모두 표준농도와 검출농도의 평균 대비율이 1에 매우 근접해 있어, 수십에서 수백 nanograms NDMA per liter의 분석이 가능함을 보여주었다. 하수처리장 처리수에 주입한 NDMA의 분석에서도 다른 물질에 의한 간섭없이 정확한 농도 검출이 가능했는데, 이는 목적물질을 선별적으로 분석해내는 derivatization 과정에 의한 것으로 나타났다. HPLC와 fluorescence derivatization 기법을 이용한 NDMA의 분석은 상수 및 하수를 사용하는 다양한 실험 연구에서 NDMA를 분석하는 방법으로 효과적으로 사용될 수 있을 것이다.