• Title/Summary/Keyword: depth of penetration

Search Result 1,072, Processing Time 0.032 seconds

Essential Oil Penetration Depth in Prunus sargentii Rehder

  • Ahmed, Sheikh Ali;Hong, Seong-Du;Chun, Su-Kyoung
    • Journal of the Korea Furniture Society
    • /
    • v.18 no.4
    • /
    • pp.307-311
    • /
    • 2007
  • An experiment was conducted to know the essential oil penetration depth in radial and longitudinal direction of Prunus sargentii. Oil penetration depth was found greater than radial flow depth. Vessel conducted oil more than wood fiber. In radial direction, body ray parenchyma was found more permeable than marginal ray parenchyma and it was about 138% times higher. Furthermore penetration depth of oil in intercellular space was greater than ray parenchyma and it was about 250% higher than ray parenchymas. Initial flow speed was found high and then it gradually decreased.

  • PDF

A study of Determination of Frost penetration Depth in incheon Area (인천지역의 동결깊이산정에 관한 연구)

  • Kim, Hui-Doo;Yang, Seong-Hwan
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.5-6
    • /
    • 2015
  • Recently, freezing index of frost penetration depth estimation used in Korea is applied according to the standard, published by MOLIT in 2003. However, it is difficult to consider can not be determined to standard reflects weather conditions in accordance with the current climate warming or abnormally high temperature. Also the temperature should be considered local variables because heavy local gap. Therefore, this study is through the freezing index presented in MOLIT's code by calculating the frost penetration depth determining whether the adequacy and conducted a study to apply in the field. As a result, when the Elevation 100m to standard in Incheon frost penetration depth is found to be 50.8cm.

  • PDF

Effect of three different irrigation solutions applied by passive ultrasonic irrigation

  • Llena, Carmen;Forner, Leopoldo;Cambralla, Raquel;Lozano, Adrian
    • Restorative Dentistry and Endodontics
    • /
    • v.40 no.2
    • /
    • pp.143-148
    • /
    • 2015
  • Objectives: This study evaluated the maximum depth and percentage of irrigant penetration into dentinal tubules by passive ultrasonic irrigation (PUI). Materials and Methods: Thirty extracted human teeth were instrumented and divided into three groups. According to final irrigation regimen, 5.25% sodium hypochlorite (Group A, NaOCl), 2% chlorhexidine (Group B, CHX) and saline solution (Group C, control group) were applied with Irrisafe 20 tips (Acteon) and PUI. Irrigant was mixed with 0.1% rhodamine B. Sections at 2 mm, 5 mm, and 8 mm from the apex were examined with confocal laser scanning microscopy (CLSM). The percentage and maximum depth of irrigant penetration were measured. Kruskal-Wallis test and Mann-Whitney test were performed for overall comparison between groups at each level and for pairwise comparison, respectively. Within a group, Wilcoxon test was performed among different levels. p values less than 0.05 were considered significant. Results: In all groups, highest penetration depth and percentage of penetration were observed at the 8 mm level. At 2 mm level, Groups A and B had significantly greater depths and percentages in penetration than Group C (p < 0.05), but there were no significant differences between Groups A and B. At 5 mm level, penetration depths and percentage of penetration was not significantly different among the groups. Conclusions: NaOCl and CHX applied by PUI showed similar depth and percentage of penetration at all evaluated levels.

Impregnation of Castanea creanata Wood by Hydrophobic Oil

  • Ahmed, Sheikh Ali;Lee, Kyoung-Min;Chun, Su-Kyoung
    • Journal of the Korea Furniture Society
    • /
    • v.19 no.1
    • /
    • pp.91-96
    • /
    • 2008
  • This paper investigates the penetration of essential oil into radial and longitudinal directions of Castanea crenata. Present study was performed to know the essential oil penetration depth in radial and longitudinal direction of Castanea crenata. Essential oil penetration depth was found higher in longitudinal direction than in radial direction and it was about 53 times high at 15.0 second of penetration. In early wood, fiber conducted oil more than that of large vessel. In heartwood, fiber had played an important role for the conduction of oil. But in sapwood, small vessel conducted oil deeper than wood fiber, which was also significantly different from large. On the other hand, large vessel in heartwood had statistically lower penetration depth than that of fiber and small vessel. At the beginning of penetration the speed was high and gradually decreased in course of time.

  • PDF

Capillary Flow in Different Cells of Thuja orientalis, Gmelina arborea, Phellodendron amurense

  • Chun, Su Kyoung
    • Journal of the Korea Furniture Society
    • /
    • v.28 no.3
    • /
    • pp.248-258
    • /
    • 2017
  • A study was carried out to observe the 1% aqueous safranine solution flow speed in longitudinal and radial directions of softwood Thuja orientalis L., diffuse-porous wood Gmelina arborea Roxb., and ring-porous wood Phellodendron amurense Rupr., Longitudinal flow was considered from bottom to top while the radial flow was considered from bark to pith directions. In radial direction, ray cells and in longitudinal direction tracheids, vessel and wood fiber were considered for the measurement of liquid penetration speed at less than 12% moisture contents(MC). The variation of penetration speed for different species was observed and the reasons behind for this variation were explored. The highest radial penetration depth was found in ray parenchyma of T. orientalis but the lowest one was found in ray parenchyma of P. amurense. The average liquid penetration depth in longitudinal trachied of T. orientalis was found the highest among all the other cells. The penetration depth in fiber of G. arborea was found the lowest among the other longitudinal cells. It was found that cell dimension and also meniscus angle of safranine solution with cell walls were the prime factors for the variation of liquid flow speed in wood. Vessel was found to facilitate prime role in longitudinal penetration for hardwood species. The penetration depth in vessel of G. arborea was found highest among all vessels. Anatomical features like ray parenchyma cell length and diameter, end-wall pits number were found also responsible fluid flow differences. Initially liquid penetration speed was high and the nit gradually decreased in an uneven rate. Liquid flow was captured via video and the penetration depths in those cells were measured. It was found that even in presence of abundant rays in hardwood species, penetration depth of liquid in radial direction of softwood species was found high. Herein the ray length, lumen area, end wall pit diameter determined the radial permeability. On the other hand, vessel and fiber structure affected the longitudinal flow of liquids. Following a go-stop-go cycle, the penetration speed of a liquid decreased over time.

An Analysis of Frost Penetration Depths in Pavements in Korea (국내 동결심도 조사 및 분석)

  • Kim, Young-Chin;Hong, Seung-Seo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.78-89
    • /
    • 2008
  • In this study the frost penetration depth along national roads in Korea were measured and analyzed over several years. The frost penetration depth was analyzed with respect to the Provinces of Korea and sunny/shaded areas. Additionally, the measurement results were compared to the formular of the US Army Corps of Engineers and Terada in Japan.

  • PDF

Examination on Required Cover Depth to Prevent Reinforcement Corrosion Risk in Concrete

  • Yoon, In-Seok
    • Corrosion Science and Technology
    • /
    • v.11 no.5
    • /
    • pp.157-164
    • /
    • 2012
  • In first experiment series, this paper is devoted for examining progress of reinforcement corrosion due to carbonation in concrete and to quantify uncarbonation depth to protect reinforcement from corroding. The tolerance of cover depth should be considered in order to prevent carbonation-induced corrosion. From the relationship between the weight loss of reinforcement and corrosion current density for a given time, therefore, the tolerance of cover depth to prevent carbonation-induced corrosion is computed. It is observed that corrosion occurs when the distance between carbonation front and reinforcement surface (uncarbonated depth) is smaller than 5 mm.As a secondary purpose of this study, it is investigated to examine the interaction between carbonation and chloride penetration and their effects on concrete. This was examined experimentally under various boundary conditions. For concrete under the double condition, the risk of deterioration due to carbonation was not severe. However, it was found that the carbonation of concrete could significantly accelerate chloride penetration. As a result, chloride penetration in combination with carbonation is a serious cause of deterioration of concrete.

Field Model Tests on Frost Penetration Depths and Frost Heave Amounts in Ballast track and Concrete track (현장모형실험을 통한 자갈궤도와 콘크리트궤도의 동결심도 및 동상량 측정)

  • Kim, Young-Chin
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.4
    • /
    • pp.506-514
    • /
    • 2016
  • Experimental ballast track and concrete track were installed on the railway site and the frost penetration depth and the frost heave amount in the winter were measured. As a result, when the freezing index was the same, the frost penetration depth of concrete track was deeper than that of ballast track. Furthermore, when an XPS and polyethylene aggregate layer was installed below the ballast track, the frost penetration depth of the ballast track decreased significantly; in the case of the concrete track, the frost penetration depth decreased when the thickness of the subbase increased. Meanwhile, the frost heave amount also decreased when an XPS and polyethylene aggregate layer was installed below the ballast track ; in the case of the concrete track, the frost heave amount decreased when the thickness of the subbase increased.

Iontophoresis Enhances Transdermal Delivery of Methylene Blue in Rat Skin (I): The Effect of Current Application Duration

  • Lee, Jae-Hyoung;Choi, Eun-Young
    • The Journal of Korean Physical Therapy
    • /
    • v.23 no.6
    • /
    • pp.77-84
    • /
    • 2011
  • Purpose: The objectives of this study were to determine the enhancing effect of iontophoresis method as it transdermally deliver methylene blue (MB) using visual examination, in terms of penetration depth and tissue distribution in the skin, and to determine the effect of application duration on the efficacy of iontophoresis. Methods: Twenty-four male Sprague-Dawley rats were randomly divided into 5-, 10-, 20-, and 40-minute groups. These rats were exposed to either topical or anodic iontophoresis of 1% MB using a direct current of $0.5mA/cm^2$ for 5, 10, 20, and 40 minutes. Using cryosections of rat tissues, the penetration depth of MB was measured using light microscopy. Results: Significant differences in the penetration depth (F=54.20, p<0.001) were detected among the four groups. Post hoc comparisons of the penetration depth of MB data pooled across groups showed no significant difference between all topical application groups and 5-minute iontophoresis group, but did reveal a significant difference in the penetration depth between all topical application groups and 5-minute iontophoresis group versus 10-minute group, between the 10-minute and 20-minute group, and between the 20-minute and 40-minute iontophoresis group (p<0.05). Conclusion: The results demonstrate that iontophoresis enhances transdermal delivery of MB across stratum corneum of skin barrier by visual examination. Furthermore, the penetration depth of iontophoretic transdermal delivery of MB was dependent on the application duration. The duration of iontophoresis is one of the important factor in the efficacy of iontophoresis application.

A Study of Frost Penetration Depth and Frost Heaving in Railway Concrete Track (콘크리트 궤도의 동결깊이 및 동상량 측정 연구)

  • Lee, Daeyoung;Kim, Youngchin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.1
    • /
    • pp.35-41
    • /
    • 2014
  • Many infra suructure such as road, railway, building and utility foundations have been damaged by the repeated freezing and thawing of the soil during winter and spring every year in seasonal frost region. The frost penetration depth is most important factor in the design of structure such as road, railway and building in seasonal frost region. This paper presents the results of calculation of frost penetration depth and frost heaving in concrete track for railway construction. Model concrete track were installed near the railway track in Gangwon, Gyeonggi, Choongbuk province and frost penetration depth were measured using methylene blue frost penetration depth gauge. Model concrete track in Cheolwon, frost heaving of concrete track were also evaluated. The measure of maximum frost penetration depth and frost heaving can be applied to design railway track for cold region in Korea.