• 제목/요약/키워드: denture relining material

검색결과 14건 처리시간 0.025초

국소의치상을 위한 연성 이장재사용시 교합압에 따른 의치상 변위(Displacement)량 비교 (A STUDY ON DIFFERENT AMOUNT OF DENTURE BASE DISPLACEMENT USING SOFT DENTURE RELINING MATERIAL UNDER MASTICATORY FORCE)

  • 이호용
    • 대한치과보철학회지
    • /
    • 제36권1호
    • /
    • pp.18-25
    • /
    • 1998
  • The purpose of this study was to determine how to use soft relining material by observing an amount of denture displacement according to the different base area of residual ridge and thickness of soft relining material under masticatory force. Stone models that simulated residual ridge were made with different amount of denture base area and denture was fabricated by conventional heat curing resin with usual manner on the model and relined by silicone type soft relining material with different thickness. Specimen was examined the amount of denture displacement by Instron within range of normal occlusal force. The results were as following : 1. The increasing rate of denture displacement was higher than that of soft relining material thickness. 2. The amount of denture displacement decreased 1.7 times when base area became double at same thickness of soft relining material 3. The increasing rate of denture displacement was higher than that of occlusal force

  • PDF

의치상 첨상재의 종류와 임상적 고려사항 (Clinical considerations for complete denture relining)

  • 조영은
    • 구강회복응용과학지
    • /
    • 제40권2호
    • /
    • pp.39-45
    • /
    • 2024
  • 의치상 하방의 잔존 치조제는 시간이 지남에 따라 생리적인 흡수가 일어난다. 이로 인하여 기존의 의치는 잔존 치조제와의 적합성이 떨어지게 되며, 임상적으로 교합평면의 변화, 수직고경의 감소, 의치의 유지력과 안정성의 소실로 인한 구강기능의 상실 및 심미적인 손상이 나타난다. 따라서 의치상과 잔존 치조제 사이의 첨상은 의치의 유지관리면에서 필수적이며 잔존 치조제와 의치상의 정확한 적합은 의치 치료의 성공을 결정하는 중요한 요인이 된다. 통상적인 첨상의 방법으로는 진료실에서 시행하는 직접법과 기공실에서 시행하는 간접법이 있다. 직접법은 진료실에서 시행하기 때문에 간편하고 쉽게 시행할 수 있는 장점이 있으나, 의치상 레진과 첨상재의 결합강도에 따라 영향을 받을 수 있는 단점이 존재한다. 반면, 간접법은 기공실에서 시행하며 첨상재와 의치상 레진간의 결합력을 제공한다는 장점이 있으나, 기공실 작업 기간 동안에 환자가 의치를 사용할 수 없다는 단점이 있다. 본 연구에서는 CAD-CAM의치를 포함하여 첨상에 사용하는 재료들과 각각의 특징들을 살펴보고, 첨상시 임상적으로 고려해야 하는 사항에 대해 알아보고자 한다.

Wettability of denture relining materials under water storage over time

  • Jin, Na-Young;Lee, Ho-Rim;Lee, Hee-Su;Pae, Ahran
    • The Journal of Advanced Prosthodontics
    • /
    • 제1권1호
    • /
    • pp.1-5
    • /
    • 2009
  • STATEMENT OF PROBLEM. Poor wettability of denture relining materials may lead to retention problems and patient discomfort. PURPOSE. Purpose of this study is to compare and evaluate wettability of nine denture relining materials using contact angle measurements under air and water storage over time. MATERIAL AND METHODS. Nine denture relining materials were investigated in this study. Two heat-curing polymethyl-methacrylate(PMMA) denture base materials: Vertex RS, Lang, one self-curing polyethyl-methacrylate(PEMA) chairside reline resin: Rebase II, six silicone relining materials: Mucopren soft, Mucosoft, $Mollosil^{{R}}$ plus, Sofreliner Touch, GC $Reline^{TM}$ Ultrasoft, Silagum automix comfort were used in this experiment. Contact angles were measured using high-resolution drop shape analysis system(DSA 10-MK2, KRUESS, Germany) under three conditions(in air after setting, 1 hour water storage, and 24 hours water storage). Nine materials were classified into three groups according to material composition(Group 1: PMMA, Group 2: PEMA, Group 3: Silicone). Mean values of contact angles were compared using independent samples t-test and one-way ANOVA, followed by a Scheffe's post hoc analysis($\alpha$=0.01). RESULTS. Contact angles of materials tested after air and water storage increased in the following order: Group 1(PMMA), Group 2(PEMA), Group 3(Silicone). Heat-cured acrylic denture base resins had more wettability than silicone relining materials. Lang had the highest wettability after 24 hours of water storage. Silicone relining materials had lower wettability due to their hydrophobicity. Wettability of all denture relining materials, except Rebase II and $Mollosil^{{R}}$ plus, increased after 24 hours of water storage. CONCLUSIONS. Conventional heat-cured resin showed the highest wettability, therefore, it can be suggested that heat-cured acrylic resin is material of choice for denture relining materials.

키토산을 첨가한 개상용 레진의 세균부착에 관한 연구 (ADHERENCE OF ORAL BACTERIA ON VARIOUS DENTURE RELINING MATERIALS WITH CHITOSAN)

  • 방몽숙;김영이
    • 대한치과보철학회지
    • /
    • 제39권4호
    • /
    • pp.444-451
    • /
    • 2001
  • The purpose of this study was to evaluate the rate of adherence of bacteria on various denture relining materials and to find out the effects of chitosan, when it was added to denture relining materials. Denture relining materials such as Tokuso rebase normal $set^{(R)}$, Mild $rebaron^{(R)}$, $Kooliner^{TM}$, and New $truliner^{TM}$ were used in this study. The adherence of Streptococcus mutans was studied on the surfaces in the denture relining materials with chitosan and in those without chitosan. When chitosan was added to M17 broth and MRS broth, the viable cell count of Streptococcus mutans was reduced. The viable cell count of Streptococcus mutans on the specimens decreased in the following order : Mild rebaron, Tokuso rebase normal set, and Newtruliner and Kooliner. The deture relining materials with chitosan showed a lower rate of adherence of Streptococcus mutans than those without chitosan.

  • PDF

3D-프린팅 의치상 레진과 열중합 의치상 레진에서의 의치 첨상 재료 간의 전단결합강도 비교 연구 (A comparison study on shear bond strength of 3D printed resin and conventional heat-cured denture base resin to denture relining materials)

  • 조성윤;송영균
    • 구강회복응용과학지
    • /
    • 제37권4호
    • /
    • pp.232-243
    • /
    • 2021
  • 목적: 다양한 3D 프린팅 의치상 레진과 여러 가지 의치 첨상 재료 간의 전단결합강도를 평가하여 기존의 열중합 의치상 레진과의 전단결합강도를 비교 평가하고자 하였다. 연구 재료 및 방법: 열중합레진(Vertex RS)과 3D프린팅 의치상 레진 두종(DENTCA Denture base II, NextDentTM Base)을 사용하였다. 의치 첨상 재료로는 성분이 다른 총 4종(Tokuyama Rebase II fast, Kooliner, Denture Liner, Denture Liner, Lang Jet Denture Repair Kit)을 사용하여 12개의 군으로 분류하였다. ISO/TS 11405규격에 따라 접착을 시행하였다. 전단결합강도를 측정하였고, 이후 입체현미경과 주사전자현미경을 이용하여 접착 계면을 관찰하고 파절편의 분석을 통하여 파절 양상을 조사하였다. 결과: 3D 프린팅 의치상 레진 군에서 의치 첨상 재료와의 전단결합강도가 열중합레진 군에 비해 유의하게 낮은 전단결합강도 결과를 나타내었다(P < 0.05). Polymethyl methacrylate계열의 첨상재료의 경우, 의치상종류와 관계없이 높은 전단결합강도를 보였다. 파절 양상은 대부분의 군에서 접착성 파절이 나타났고 일부 군에서 응집성 파절과 혼합성 파절 양상이 나타났다. 결론: Polymethyl methacrylate를 주성분으로 하는 의치 첨상 재료가 실험에 사용된 모든 의치상 레진에서 다른 의치 첨상 재료와 비교하여 높은 전단 결합강도 값을 나타내었지만, 직접법으로 의치 첨상을 시행할 경우 단량체로 Isobutyl methacrylate 성분의 의치 첨상재료를 사용하는 것이 전단결합강도면에서 유리할 것으로 사료된다.

Effect of surface treatment on shear bond strength of relining material and 3D-printed denture base

  • Park, Se-Jick;Lee, Joon-Seok
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권4호
    • /
    • pp.262-272
    • /
    • 2022
  • PURPOSE. This study aimed to analyze the shear bond strength between the 3D-printed denture base and the chairside relining material, according to the surface treatment. MATERIALS AND METHODS. Cylindrical specimens were prepared using DENTCA Denture Base II. The experimental groups were divided into 6 (n = 10): no surface treatment (C), Tokuyama Rebase II Normal adhesive (A), sandblasting (P), sandblasting and adhesive (PA), sandblasting and silane (PS), and the Rocatec system (PPS). After bonding the chairside relining material to the center of the specimens in a cylindrical shape, they were stored in distilled water for 24 hours. Shear bond strength was measured using a universal testing machine, and failure mode was analyzed with a scanning electron microscope. Shear bond strength values were analyzed using one-way analysis of variance, and Tukey's honest significant difference test was used for post-hoc analysis (P < .05). RESULTS. Group PPS exhibited significantly higher shear bond strength than all other groups. Groups P and PA displayed significantly higher bond strengths than the control group. There were no significant differences between groups PS and A compared to the control group. Regarding the failure mode, adhesive failure occurred primarily in groups C and A, and mixed failure mainly in groups P, PA, PS, and PPS. CONCLUSION. The shear bond strength between the 3D-printed denture base and the chairside relining material exhibited significant differences according to the surface treatment methods. It is believed that excellent adhesive strength will be obtained when the Rocatec system is applied to 3D-printed dentures in clinical practice.

Double crown retained RPD의 4년 임상 관찰 (DOUBLE CROWN RETAINED REMOVABLE PARTIAL DENTURE - 4 YEARS IN RETROSPECT)

  • 이석형
    • 대한치과보철학회지
    • /
    • 제42권1호
    • /
    • pp.73-82
    • /
    • 2004
  • Statment of problem : Little in known about the importance of selection of various double crowns as retainer in determining the outcome of treatment with double crown retained removable partial denture. Purpose : To obtain information about the effects and the results of this treatment modality. Material and methods : This study describes 61 double crown retained removable partial dentures worn by 51 patients from Samsung Medical Center, Seoul a time ranging between 6 and 48 months and evaluate occlusal contacts on the denture teeth, denture movement, incidence of denture relining, denture retention, fracture of dentures and abutments, hygiene, residual ridge inflammatory changes, number of lost abutment,. interruption of denture use. Results : One tenth of all the restorations were relined. Restorations in 21 arches fractured repeatedly for various reasons . There was no apparent interrelationship between fractures and the five groups. Conclusion : Good prognoses of removable partial dentures were shown in all groups(Kennedy Classes I, II, III, combination and few remaining abutment).

열가소성 의치상 레진과 첨상용 레진의 접착 강도에 저온플라즈마가 미치는 효과 (Nonthermal plasma on the shear bond strength of relining resin to thermoplastic denture base resin)

  • ;;송소연;박진홍;이정열;신상완
    • 대한치과보철학회지
    • /
    • 제56권3호
    • /
    • pp.199-205
    • /
    • 2018
  • 목적: 이 연구는 저온 플라즈마가 자가중합형 재이장용 레진과 주입형 열가소성 의치상 레진의 결합 강도에 미치는 영향을 다른 표면 처리 방법에서 평가하기 위함이다. 재료 및 방법: 네 가지 열가소성 의치상이 이 연구에서 사용되었다: Acrylic Resin (Acrytone), Polyester (Estheshot-Bright), Polyamide (Valplast), Polypropylene (Weldenz)에 다양한 표면처리를 시행하였다: 대조군, 저온플라즈마, Sandblasting, Sandblasting와 저온플라즈마. 표면 처리 후 모든 시편은 Tokuyama Rebase II를 이용하여 원형의 테플론 관에 접착되었다. 전단강도는 Universal testing machine을 통해 crosshead speed 1 mm/min으로 측정되었다. 통계 분석 방법으로는 이원분산분석을, 사후 검정 방법으로는 Tukey's test가 사용되었다. 결과: Acrytone이 다른 열가소성 의치상 레진 그룹에 비하여 통계적으로 유의한 수준에서 더 높은 전단강도를 보인 반면 Weldenz는 가장 낮은 값을 나타냈다. Sandblast와 저온플라즈마를 순차적으로 시행한 조건에서 모든 레진 그룹 중 통계적으로 유의한 수준에서 가장 높은 전단강도 값을 나타냈다. 결론: 열경화성 의치상 레진과 재이장용 레진 사이의 전단강도에 저온플라즈마는 제한된 효과를 나타내었으며, sandblasting 처리와 함께 처리되었을 때 두 재료간 전단강도는 향상되었다.

첨상용 레진의 성형법이 의치상의 굴곡강도에 미치는 영향 (The Effect of Packing Method of Relining Material on the Flexural Strength of Denture Base Resin)

  • 김민철;김유리
    • 구강회복응용과학지
    • /
    • 제27권2호
    • /
    • pp.197-207
    • /
    • 2011
  • 의치상의 첨상에 사용하는 레진의 종류가 의치상의 굴곡강도와 굴곡계수에 미치는 영향을 비교하는데 있다. 국제표준규격 제 1567 호(ISO 1567:1999)를 참고로 2 가지의 의치상용 열중합레진(Lucitone199(Dentsply Int., NewYork, USA), SR-Ivocap(Ivoclar AG, Schaan, Liechtenstein))을 이용하여 길이 64 mm ${\times}$ 폭 50 mm ${\times}$ 두께 3.3 mm 의 시편을 제작하였다. 각각의 제작된 시편을 다시 두께 2.0 mm 로 규격화한 뒤 3 종류의 레진(Lucitone199 (Dentsply), SR-Ivocap(Ivoclar), Rebase II(Tokuyama Co., Ltd, Tokyo, Japan))으로 각각 1.3 mm 의 두께로 첨상을 하였다. 제작된 시편(n=10)을 증류수가 담긴 밀폐된 용기 내에 $37^{\circ}C$에서 50 시간 동안 보관하였다. 그 후 만능시험기를 이용하여 시편의 3 점 굴곡강도와 굴곡계수를 측정하였다. 지지대간의 거리는 50 mm, crosshead speed 는 5 mm/min 였다. 측정값은 One-way ANOVA 로 비교 분석하였고, Tukey test 를 이용하여 사후 검정하였다. 열중합형 레진과 자가중합형 레진으로 첨상한 군들은 모두 첨상을 시행하지 않은 대조군보다 통계적으로 유의하게 낮은 굴곡강도와 굴곡계수를 나타났다. 본래의 의치상용 레진의 종류와 무관하게 Lucitone199 을 이용해 첨상한 군이 SR-Ivocap 을 이용한 군보다 통계적으로 유의하게 높은 굴곡강도와 굴곡계수를 보였다. 자가중합형 레진을 이용한 군은 열중합형 레진을 이용한 군 보다 통계적으로 유의하게 낮은 굴곡강도와 굴곡계수를 보였다. 의치상의 첨상 시 자가중합형 레진 보다 열중합형 레진을 이용하는 것이 우수한 기계적 성질을 보였다. 열중합형 레진을 이용한 첨상 시 본래의 의치상과 같은 종류의 레진을 사용하는 것은 의치상의 기계적 성질에 영향을 미치지 않았으며 Lucitone199 를 이용한 가압주형법에서 가장 우수한 물성을 나타냈다.

Thermocycling이 첨상용 레진과 금속 의치상간의 전단결합강도에 미치는 영향 (The Effects of Thermocycling on the Shear Bond Strength between Metal Denture Base and Relining Resin)

  • 이준석
    • 구강회복응용과학지
    • /
    • 제21권2호
    • /
    • pp.95-103
    • /
    • 2005
  • Purpose: Recently, various metal primers have been developed, and these are known to increase the bond strength between metal and relining resin. In this study, the change in bond strength according to amount of thermocycling was evaluated. Materials and Methods: In this study, 216 specimens were fabricated. Tokuyama Rebase $II^{(R)}$(Tokuyama Corp., Japan) and $Kooliner^{(R)}$(GC America Inc., Japan) as relining material, and MR. $Bond^{(R)}$(Tokuyama Corp., Japan) and Alloy $Primer^{(R)}$(Kuraray Medical Inc., Japan) as a metal primers were used. Using Ni-Cr and various metal surface treatment methods, resin was bonded and the change in bond strength during thermocycling was measured. The data was analyzed by one-way ANOVA, t-test(p<.05 level of significance). Results: When comparing the groups with only sandblasting, rapid decrease in shear bond strength could be seen. In the groups using Tokuyama Rebase $II^{(R)}$, with the exception of the 1000 and 2000 cycle groups, each group showed statistically significant decrease in shear bond strength(p<0.05). In comparison according to relining materials, $Kooliner^{(R)}$ showed higher shear bond strength than Tokuyama Rebase $II^{(R)}$ in all groups. In groups using MR $bond^{(R)}$, $Kooliner^{(R)}$ had higher shear bond strength than Tokuyama Rebase $II^{(R)}$ but, there was no statistical significance(p<0.05). In the other groups, $Kooliner^{(R)}$ showed significantly higher shear bond strength(p<0.05). There was significant difference between groups with sandblasting and metal primer treatments(p<0.05). In comparison according to metal primer materials, Alloy $Primer^{(R)}$ showed the highest shear bond strength but there was no statistical significance(p>0.05). According to the number of thermocycling cycles, when using Tokuyama Rebase $II^{(R)}$, there were no significant differences between the 0, 1000 and 2000 cycle groups regardless of the type of metal primer. There were no differences between the 2000 and 3000 cycle groups. When using $Kooliner^{(R)}$, regardless of the type of metal primer, there were no significant differences between the 0, 1000, 2000 and 3000 cycle groups(p>0.05). Conclusion: The use of metal primers showed increase in bond strength, and the stability after to thermocycling has been authenticated. Thus, the use of metal primers in relining and rebasing of metal frameworks is essential. But when selecting the material various physical properties should be considered.