• Title/Summary/Keyword: denture part

Search Result 50, Processing Time 0.02 seconds

Implant-retained overdenture with CM LOC® Pekkton® in maxillary edentulous patient (상악 완전 무치악 환자에서 CM LOC® Pekkton® attachment를 이용한 임플란트 유지 피개의치 수복 증례)

  • Hong, Mun Gi;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.4
    • /
    • pp.321-328
    • /
    • 2017
  • Treatment options for edentulous patients are complete denture and implant prosthesis. A two implant-retained overdenture can be considered the first treatment in the edentulous mandible, but there is no clear consensus of treatment for edentulous maxilla. Implant-retention/support overdenture shows better retention and stability than complete denture and is less expensive and more esthetic than implant-supported fixed prosthesis. CM $LOC^{(R)}$ $Pekkton^{(R)}$ attachment is a solitary type attachment and evaluated to have excellent abrasion resistance and retention with a female part made of poly-ether-ketone-ketone. Meanwhile, SR Ivocap system is injection molding method and discussed to show few changes in the vertical dimension of denture and have excellent fracture resistance. In this case, we restored maxillary arch with a four implant-retained overdenture using CM $LOC^{(R)}$ $Pekkton^{(R)}$ and SR Ivocap system, and mandibular arch with a removable partial denture. Through this procedure, satisfactory outcomes were achieved both in functional and esthetic aspects.

The Effects of National Health Insurance Denture Coverage Policies for the Elderly on the Unmet Dental Needs of the Edentulous Elderly

  • Ahn, Eunsuk;Hwang, Ji-Min;Han, Ji-Hyoung
    • Journal of dental hygiene science
    • /
    • v.18 no.3
    • /
    • pp.182-187
    • /
    • 2018
  • As the elderly population increases, they are increasingly affected by oral health problems. Therefore, efforts are being made to improve the oral health of older people, alleviate mental discomfort, and reduce unmet dental needs. This study was conducted to confirm the relationship between the National Health Insurance Elderly Denture Coverage and the unmet dental need for the edentulous elderly, as part of the protection policy. We analyzed the 2011 and 2013 Community Health Survey data of the edentulous elderly, aged 75 years or older, before 2012. In order to more precisely confirm the effects of the denture donation policy on unmet dental care, basic life recipients who were subject to the free elderly prosthetic project were excluded from the analysis. The final analysis included 20,400 subjects. According to our investigation of the factors that affect the unmet dental needs of the elderly, the National Health Insurance Elderly Denture Coverage did not affect unmet dental needs. The statistically significant variables that affected the unmet dental needs of the elderly were education and income levels, which are representative socioeconomic status variables. The lower the level of education, the unhealthier the dental care experience, and income levels showed a similar tendency. The elderly who have a low socioeconomic status are more likely to experience unmet dental needs because they lack the knowledge and socioeconomic ability to pay for dental care. Therefore, the policy for health protection of the entire elderly population should be continuously expanded. In addition, the socioeconomically vulnerable groups may have health problems due to the restriction of medical use, which may lead to quality of life deterioration.

A simplified chair-side remount technique using customized mounting platforms

  • Chauhan, Mamta Devendrakumar;Dange, Shankar Pandharinath;Khalikar, Arun Narayan;Vaidya, Smita Padmakar
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.3
    • /
    • pp.170-173
    • /
    • 2012
  • Correct occlusal relationships are part of the successful prosthetic treatment for edentulous patients. Fabrication of complete dentures comprises of clinical and laboratory procedures that should be executed accurately for achieving success with fabricated dentures. Errors occurring during the clinical and laboratory procedures of a denture may subsequently lead to the occlusal errors in the final prosthesis. These occlusal errors can be corrected in two ways: i) in patient's mouth ii) by recording new centric relation and remounting dentures on an articulator. The latter method is more feasible because the mobility of denture base on the mucosa in oral cavity does not permit the identification of premature contacts in centric occlusion and tooth guided eccentric excursions. This article describes a modest and effective clinical chair-side remount procedure using customized mounting platforms.

A study on the amendments of long-term care-related legislations for the introduction of part-time facility dentists (노인장기요양시설 치과촉탁의제 도입을 위한 제도 개선 방향)

  • So, Jong-Seob
    • The Journal of the Korean dental association
    • /
    • v.53 no.10
    • /
    • pp.696-704
    • /
    • 2015
  • The coverage of the National Health Insurance for the elderly is expanding to denture and implants. Although the National Long-Term Care Insurance was just being settled, Oral health service was not provided to the Elderly in Long-Term Care Facilities. The long-term care facilities had part-time facility doctors. However, there is no dentist in the long-term care facility because of lack of long-term care insurance-related legislations. The amendments of long-term care insurance-related legislations for the introduction of part-time facility dentists are needed because the elderly in long-term care facility are vulnerable to oral health. For the substantial management of the National Long-Term Care Insurance, the development of oral health service model for the elderly and education materials for the dental team will be needed. Also, adequate dental service fee of the National longterm care insurance will be needed.

A Study on the Noise by working Process in Dental Laboratory (치과기공실(齒科技工室)의 작업공정별(作業工程別) 소음(騷音)에 관한 연구(硏究))

  • Nam, Sang-Yong
    • Journal of Technologic Dentistry
    • /
    • v.15 no.1
    • /
    • pp.27-41
    • /
    • 1993
  • Degree of noise by personal dental laboratory working process and degree of noise by complex dental laboratory working process were measured separtely. The time of exposure to noise greater than 70dB was analyzed. Then, the whole degree of noise in dental laboratory was estimated on the basis of afore-mentioned information. Questionaire were employed to investigate the mental, emotional and physiological effects of noise in dental technicians, The purpose of this study was to provide basic information on keeping dental techneicans who are exposed to noise pollution in good working condition and good health. Results obtained are as follows ; 1. Polishing process in each working part showed high degree of noise greater than 70dB in terms of degree of noise by personal working. 2. Degree of noise by complex working process in each working part was greater than that of personal working process. 3. Time of exposure to noise complex working process the part of porcelain 150min, partial denture 120 min, crown and bridge 100 min, full denture 80 min. 4. Degree of noise by time in dental laboratory was 80dB in general for polishing process and below 75dB for waxing process. 5. Effects of noise on mental and emotional state of dental technicians showed that they felt irritated every day(14%), irritated once in a while(29%) and easily ger mad(19%). 6. Effects of noise on heart and stomach were hyper-gastric acid(38%), gastric ulcer(11%), gastritis(5%), deuodenal ulcer(3%) and weak heart function(32%). 7. Effects of noise in the hearing ability were weak(39%), moderate(33%) and normal(14%) Data presented in this study demonstrated that noise in the dental laboratory exerts profound effect on dental technicians mentally, physiologically and emotionally, in light of the above results, therefore, it appears advisable to devots substantial on the management of working condition and put further(continuing) efforts in the investigation for reducing noise problem.

  • PDF

Comparison of digitalized fabrication method for interim removable partial denture: case reports (두 가지 프린팅 방식으로 제작한 임시 가철성 의치의 비교: 증례 보고)

  • Yoon-Jeong Shin;Cheong-Hee Lee;Du-Hyeong Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.379-385
    • /
    • 2023
  • With the recent development of digital dentistry, fully digitalized methods for fabricating dentures, using intraoral scans and computer-aided design/computer-aided manufacturing (CAD-CAM), are getting popular. Digital methods have the advantage of simplifying the fabrication process in the clinic and laboratory, supplementing digital data. This case report shows a fully digital fabrication method for interim removable dentures in a patient with anterior tooth loss in which implant placement is impossible or delayed. Interim removable dentures were fabricated using two methods. One method is printing tooth and base parts separately and combining, and the other method is printing the whole denture at one time and coloring on the base part. Afterward, dentures were delivered and adaptation was evaluated using the triple scan technique. The extracted site was scanned intraorally (first scan) and the interim removable denture was digitally scanned both intraorally (second scan) and, after removal extraorally (Third scan). In both method, denture adaptation was shown favorable. We report this case report as both the patient and the operator were satisfied with a simplified process using a fully digital method in the clinic.

Clinical considerations of impression making for edentulous patients (성공적인 총의치 제작을 위한 단계별 포인트 - 무치악인상채득, 이것이 핵심이다.)

  • Park, Chan-Jin
    • The Journal of the Korean dental association
    • /
    • v.55 no.1
    • /
    • pp.72-81
    • /
    • 2017
  • Regardless of the type of impression being made, the tray is the most important part of the impression-making procedure for completely edentulous patients. Dentists have to make use of a combination of rigid, thermoplastic, and resilient materials and control step-by-step procedure from irreversible hydrocolloid impression to definitive cast fabrication. For successful edentulous impression, some considerable clinical tips were guided.

  • PDF

Influence of the amount of tooth surface preparation on the shear bond strength of zirconia cantilever single-retainer resin-bonded fixed partial denture

  • Sillam, Charles-Ellie;Cetik, Sibel;Ha, Thai Hoang;Atash, Ramin
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.4
    • /
    • pp.286-290
    • /
    • 2018
  • PURPOSE. Conventional resin-bonded fixed partial dentures (RBFPDs) are usually made with a two-retainer design. Unlike conventional RBFPDs, cantilever resin-bonded fixed partial dentures (Cantilever RBFPDs) are, for their part, made with a single-retainer design. The aim of this study was to compare the effect of tooth surface preparation on the bond strength of zirconia cantilever single-retainer RBFPDs. The objective is to evaluate the shear bond strength of these single-retainer RBFPDs bonded on 3 different amount of tooth surface preparation. MATERIALS AND METHODS. Thirty extracted bovine incisors were categorized to 3 groups (n=10), with different amounts of tooth surface preparations. Teeth were restored with single-retainer RBFPDs with different retainer surfaces: large retainer of $32mm^2$; medium retainer of $22mm^2$; no retainer and only a proximal connecting box of $12mm^2$. All RBFPDs were made of zirconia and were bonded using an adhesive system without adhesive capacity. Shear forces were applied to these restorations until debonding. RESULTS. Mean shear bond strength values for the groups I, II, and II were $2.39{\pm}0.53MPa$, $3.13{\pm}0.69MPa$, and $5.40{\pm}0.96MPa$, respectively. Statistical analyses were performed using a one-way ANOVA test with Bonferroni post-hoc test, at a significance level of 0.001. Failure modes were observed and showed a 100% adhesive fracture. CONCLUSION. It can be concluded that the preparation of large tooth surface preparation might be irrelevant. For zirconia single-retainer RBFPD, only the preparation of a proximal connecting box seems to be a reliable and minimally invasive approach. The differences are statistically significant.

CORROSION PHENOMENA OF MAGNETIC ATTACHMENT USED IN ORAL ENVIRONMENT (구강 환경에서 사용된 자성 Dyna 어태치먼트의 부식현상)

  • Kwak Jong-Ha;Chung Chae-Heon;Choe Han-Cheol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.5
    • /
    • pp.470-483
    • /
    • 2002
  • The purpose of this study was to investigate further the mechanics of failure of magnets used for denture retention. Dyna magnets were retrived from denture that had failed after 34 months of clinical use. The magnets were observed and sectioned in order to analyse with high resolution scanning electron microscope. From this study, corrosion behaviors of used magnetic attachment were analysed. The results were as follows ; 1. In Nd-Fe-B based magnetic materials, the erosion-corrosion was started at ununiformed part of stainless steel cover. 2. Corrosion was initiated at weared stainless steel surface and then magnetic materials were spalled by corrosive solution. 3. Spatting was occurred in Nd-Fe-B magnet materials due to corrosion products and then corrosion rate was increased drastically. 4. Corrosion started from ununiformed stainless steel surface as well as welded zone. In conclusion, the failure of magnets may occur by either breakdown of the welding or breakdown of the encapsulating material. So, it is considered that the corrosion problem of dental magnetic materials could be solved to some extent with surface treatment of dental magnetic materials.

Immediate loading on mandibular edentulous patient with SFI Bar$^{(R)}$ overdenture

  • Kim, Ha-Young;Kim, Jin-Young-Ryan;Qadeer, Sarah;Jeong, Chang-Mo;Shin, Sang-Wan;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.1
    • /
    • pp.47-50
    • /
    • 2011
  • Despite the greater retention and low maintenance of bar attachment system, the longer clinical time and increased number of visits were the assignments to overcome in bar attachment system. This case report describes SFI-Bar$^{(R)}$ (Cendres et Me$\'{e}$taux, Biel/Bienne, Switzerland) to be solve those problems. A 65-year-old female, who had severely absorbed mandible, hoped to wear a stable mandibular denture without pain. As soon as two implants were placed on mandible, a tube bar was connected to two adaptors connected to each implant. The length of the tube bar was adjusted considering inter implant distance, and reconnected to the adaptors. Finally a female part was seated beneath the denture. This case report showed that a satisfactory clinical result was achieved by delivering bar overdenture immediately after implant placement without laboratory procedure.