• Title/Summary/Keyword: dentistry radiation

Search Result 302, Processing Time 0.028 seconds

AN ELECTRON MICROSCOPIC STUDY ON THE EFFECTS OF IRRADIATION ON THE ACINAR CELLS OF RAT PAROTID GLAND (방사선조사가 백서 이하선의 선세포에 미치는 영향에 관한 전자현미경적 연구)

  • Ko Kwang Jun;Lee Sang Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.18 no.1
    • /
    • pp.31-45
    • /
    • 1988
  • The author studied the histopathologic changes according to a single or a split dose and the time after irradiation on the acinar cells of rat parotid gland. 99 Sprague Dawley rats, weighing about l20gm, were divided into control and 3 experimental groups. In experimental groups, GroupⅠ and Ⅱ were delivered a single dose of l5Gy, 18Gy and Group Ⅲ and Ⅳ were delivered two equal split doses of 9Gy, 10.5Gy for a 4 hours interval, respectively. The experimental groups were delivered by a cobalt-60 teletherapy unit with a dose rate of 222cGy/min, source-skin distance of 50㎝, depth of l㎝ and a field size of l2×5㎝. The animals were sacrificed at 1, 2, 3, 6, 12 hours, 1, 3, 7 days after irradiation and examined by light and electron microscopy. The results were as follows: 1. As the radiation dose increased and the acinar cells delivered a single dose exposure were more damaged, and the change of acinar cells appeared faster than those of a split dose exposure. 2. The histopathologic change of acinar cells appeared at 1 hour after irradiation. The recovery from damaged acinar cells appeared at 1 day after irradiation and there was a tendency that the recovery from damage of a split dose exposure was somewhat later than that of a single dose exposure. 3. Light microscope showed atrophic change of acinar cells and nucleus, degeneration and vesicle formation of cytoplasm, widening of intercellular space and interlobular space. 4. Electron microscope showed loss of nuclear membrane, degeneration of nucleus and nucleoli, clumping of cytoplasm, widening and degeneration of rough endoplasmic reticulum, loss of cristae of mitochondria, lysosome, autophagosome and lipid droplet. 5. Electron microscopically, the change of rough endoplasmic reticulum was the most prominent and this appeared at 1 hour after irradiation as early changes of acinar cells. The nuclear change appeared at 2 hours after irradiation and the loss of cristae of mitochondria was observed at 2 hours after irradiation in all experimental groups.

  • PDF

Corrosion Charateristics of PEO-treated Ti-6Al-4V Alloy in Solution Containing Si and Mg Ions

  • Park, Seon-Yeong;Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.153-153
    • /
    • 2017
  • The application of the coating supports the mechanical characteristics of the implant, and various materials and coatings are currently being used in the implant in a way to accelerate adhesion. Especially, plasma electrolytic oxidation (PEO) coating has been proposed continually with good surface treatment of titanium alloys. Also, the PEO process can incorporate Ca and P ions on the titanium surface through variables varied factor. PEO process for bioactive surface has carried out in electrolytes containing Ca and P ions. Natural bone is composed of mineral elements such as Mg, Si, Zn, Sr, and Mn, etc. Especially, Mg and Si of these elements play role in bone formation and growth after clinical implantation of bio-implants. In this study, corrosion charateristics of PEO-treated Ti-6Al-4V alloy in solution containing Si and Mg ions has been investigated using several experimental techniques. The PEO-treated surfaces were identified by X-ray diffraction, using a diffractometer (XRD, Philips X' pert PRO, Netherlands) with Cu $K{\alpha}$ radiation. The morphology was observed by field-emission scanning electron microscopy (FE-SEM, Hitachi 4800, Japan) and energy-dispersive X-ray spectroscopy (EDX, Oxford ISIS 310, England). The potentiodynamic polarization and AC impedance tests for electrochemical degradations were carried out in 0.9% NaCl solution at similar body temperature using a potentiostat with a scan rate of 1.67mV/s and potential range from -1500mV to + 2000mV.

  • PDF

Effect of Variable Scanning Protocols on the Pre-implant Site Evaluation of the Mandible in Reformatted Computed Tomography (영상재구성 전산화 단층촬영에서 촬영조건의 변화가 하악골 술전 임플란트 부위 평가에 미치는 영향)

  • Kim Kee-Deog;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.21-32
    • /
    • 1999
  • Purpose: To evaluate the effect of variable scanning protocols of computed tomography for evaluation of pre-implant site of the mandible through the comparison of the reformatted cross-sectional images of helical CT scans obtained with various imaging parameters versus those of conventional CT scans. Materials and Methods: A dry mandible was imaged using conventional nonoverlapped CT scans with 1 mm slice thickness and helical CT scans with 1 mm slice thickness and pitches of 1.0, 1.5. 2.0, 2.5 and 3.0. All helical images were reconstructed at reconstruction interval of 1 mm. DentaScan reformatted images were obtained to allow standardized visualization of cross-sectional images of the mandible. The reformatted images were reviewed and measured separately by 4 dental radiologists. The image qualities of continuity of cortical outline. trabecular bone structure and visibility of the mandibular canal were evaluated and the distance between anatomic structures were measured by 4 dental radiologists. Results: On image qualities of continuity of cortical outline. trabecular bone structure and visibility of the mandibular canal and in horizontal measurement. there was no statistically significant difference among conventional and helical scans with pitches of 1.0. 1.5 and 2.0. In vertical measurement. there was no statistically significant difference among the conventional and all imaging parameters of helical CT scans with pitches of 1.0, 1.5, 2.0, 2.5 and 3.0. Conclusion: The images of helical CT scans with 1 mm slice thickness and pitches of 1.0, 1.5 and 2.0 are as good as those of conventional CT scans with 1 mm slice thickness for evaluation of predental implant site of the mandible. Considering the radiation dose and patient comfort, helical CT scans with 1 mm slice thickness and pitch of 2.0 is recommended for evaluation of pre-implant site of the mandible.

  • PDF

Radiographic examination protocol and patient dose in lateral cephalometric radiography in Korea (국내 의료기관에서 측방두부규격방사선촬영시 임상에서의 촬영조건 및 환자 선량)

  • Choi, Jin-Woo
    • Imaging Science in Dentistry
    • /
    • v.40 no.4
    • /
    • pp.165-169
    • /
    • 2010
  • Purpose : To survey the radiographic examination protocol for lateral cephalometric radiographic examinations and to measure their patient doses in Korea and to compare the dose according to the size of hospital, the type of image receptor system, and the installation duration. Materials and Methods : The radiographic examination protocols (kVp, mA, and exposure time) for lateral cephalometric radiography were surveyed with 61 cephalometric radiographic equipments and their patient dose-area product (DAP) measured with a DAP meter (DIAMENTOR M4-KDK, PTW, Freiburg, Germany) for 51 cephalometric radiographic equipments. The radiographic examination protocols and patient doses were compared according to the size of hospital (university dental hospital, dental hospital, and dental clinic), the type of image receptor system (film-based, DR and CR type) and the installation duration, respectively. SPSS 12.0.1 for Windows (SPSS Inc., Chicago, USA) was used for independent t-test and ANOVA test. Results : The average protocols were 77.0 kVp, 12.7 mA, 6.2 second for cephalometric radiography. The average patient dose (DAP) was $128.0mGy\;cm^2$ and 3rd quartile dose (DAP) $161.1mGy\;cm^2$ for cephalometric radiography for adult male. There was no statistically significant difference at average patient DAP according to the size of hospital, the type of image receptor system, and the installation duration, repectively. Conclusion : The average patient dose was $128.0mGy\;cm^2$ and the third quartile patient dose $161.1mGy\;cm^2$ for lateral cephalometric radiography for adult male in Korea.

Automatic detection of tooth cracks in optical coherence tomography images

  • Kim, Jun-Min;Kang, Se-Ryong;Yi, Won-Jin
    • Journal of Periodontal and Implant Science
    • /
    • v.47 no.1
    • /
    • pp.41-50
    • /
    • 2017
  • Purpose: The aims of the present study were to compare the image quality and visibility of tooth cracks between conventional methods and swept-source optical coherence tomography (SS-OCT) and to develop an automatic detection technique for tooth cracks by SS-OCT imaging. Methods: We evaluated SS-OCT with a near-infrared wavelength centered at 1,310 nm over a spectral bandwidth of 100 nm at a rate of 50 kHz as a new diagnostic tool for the detection of tooth cracks. The reliability of the SS-OCT images was verified by comparing the crack lines with those detected using conventional methods. After performing preprocessing of the obtained SS-OCT images to emphasize cracks, an algorithm was developed and verified to detect tooth cracks automatically. Results: The detection capability of SS-OCT was superior or comparable to that of trans-illumination, which did not discriminate among the cracks according to depth. Other conventional methods for the detection of tooth cracks did not sense initial cracks with a width of less than $100{\mu}m$. However, SS-OCT detected cracks of all sizes, ranging from craze lines to split teeth, and the crack lines were automatically detected in images using the Hough transform. Conclusions: We were able to distinguish structural cracks, craze lines, and split lines in tooth cracks using SS-OCT images, and to automatically detect the position of various cracks in the OCT images. Therefore, the detection capability of SS-OCT images provides a useful diagnostic tool for cracked tooth syndrome.

Diagnostic Application of Temporomandibular Joint Disorder and Ultra Sound Guided Oral &Maxillofacial application (초음파를 이용한 턱관절질환의 진단과 초음파 가이드의 활용)

  • Seong, Tae-Hwan;Park, Jung-Hyun;Kim, Sun-Jong
    • The Journal of the Korean dental association
    • /
    • v.55 no.11
    • /
    • pp.789-799
    • /
    • 2017
  • Ultrasound images are noninvasive, can be observed in real time, have no radiation exposure, do not cause pain, and are not restricted in use depending on the patient's prosthetic implant or medical condition. Since the use of ultrasound in the dental field was first applied for tooth preparation in 1957, the use of diagnostic ultrasound for the first time in 1963 has been reported. Currently, it is used in the diagnosis of soft tissue lesions such as malignant tumor or salivary gland disease, fine needle aspiration test, temporomandibular joint disease, lymph node metastasis, measurement of muscle thickness and inflammatory diseases, differentiation of periapical cyst and granulation tissue, measurement of periodontal tissue thickness. The ultrasound image can be visualized in real time. The clinician can explain the structure to the patient while consulting the patient and consult the patient. When injecting the drug into a specific site or aspirating a specific site or substance, So that it can be confirmed and practiced. Recently, ultrasonic equipment specialized in the dental field has been developed and marketed, and it is expected that the use of ultrasonic waves will become active in the dentistry. In the future, development of popular equipment with size and frequency suitable for dental diagnosis and various researches on maxillofacial ultrasonic anatomy. If clinical studies are continuously carried out to demonstrate efficacy, ultrasound is expected to aid in accurate diagnosis and treatment throughout the dentistry.

  • PDF

AN EXPERIMENTAL STUDY ON THE RADIOSENSITIVITY AND CHEMOSENSITIVITY OF MG-63 CELL LINE (MG-63 세포주의 방사선 및 항암제감수성에 관한 실험적 연구)

  • Lee Un-Gyeong;Koh Kwang-Joon
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.26 no.2
    • /
    • pp.121-132
    • /
    • 1996
  • The purpose of this study was to aid in the prediction of tumor cell tolerance to radiotherapy and/or chemotherapy. For this study, cell surviving curves were obtained for human osteosarcoma MG-63 cell line using semiautomated MTT assay. 2,4, 6, 8, 10Gy were irradiated at a dose rate of 210cGy/min using /sup 60/Co Irradiator ALDORADO 8. After irradiation, MG-63 cell lines(3×10⁴ cells/ml) were exposed to bleomycin and cisplatin at concentration of 0.2, 2, 20㎍/㎖ for 1 hour respectively. The viable cells were determined for each radiation dose and/or each concentration of drug. And they were compared to control values. The obtained results were as follows : 1. There was significant difference of surviving fraction at 4, 6, 8, 10Gy on MG-63 cell line(p<0.05). 2. There was significant difference of cytotoxicity of bleomycin or cisplatin at all concentration of 0.2, 2, 20㎍/㎖ (p<0.05) on MG-63 cell line. The cytotoxicity of cisplatin was more effective than bleomycin at concentration of 20㎍/㎖ on MG-63 cell line. 3. There was significant difference of cytotoxicity of bleomycin or cisplatin at all concentration after irradiation of 2Gy on MG-63 cell line. 4. There was significant difference of cytotoxicity of bloemycin or cisplatin at concentration of 20㎍/㎖ after irradiation than that of irradiation alone(p<0.01). But there was no significant difference of cytotoxicity of bleomycin at concentration of 20㎍/㎖ after irradiation of l0Gy than that of irradiation alone.

  • PDF

A STUDY ON THE PRE-AND POST-IRRADIATION EFFECT OF BLOOD VESSELS IN THE EXPERIMENTALLY INDUCED TONGUE CANCER (실험적 설암에서 방사선 조사전후의 혈관분포에 관한 연구)

  • Kim Young-Tae;Park Tae-Won
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.20 no.1
    • /
    • pp.41-49
    • /
    • 1990
  • The author observed the changes of vasculature of pre-and post-irradiation on DMBA induced rat tongue cancer. The study was performed by using vascular corrosion resin casting, and scanning electron microscopy. The results were as follows. 1. The capillaries runned parallely and formed bundles and, sometimes, plexus. The endothelial cells were arranged regularly and small pores were observed. 2. In irradiated normal tongue the capillaries were curved slightly and formed plexus on initial day of post-irradiation. On third day the capillaries and capillary pores were dilated and the endothelial cell arrangement was irregular. The effects of irradiation were gradually increased from initial to the 3rd day, though it was decreased after 7th day. 3. The vasculature of DMBA induced tongue cancer group were very irregular, and large avascular lesions were formed according to the cancer necrosis or tumor cell nest and the vasculature was narrowed and paralleled around the avascular lesion by compression of cancer cell nest. The vascular wall was roughened and dilated, forming club shaped or varix. 4. The vessels were curved and formed reticular network in irradiated DMBA induced tongue carinoma group. The free end of newly formed capillaries had regular width, and also irregular club shaped or aneurysmal dilatation were observed. The vascular structures were destroyed and vessels were fused in tumor necrosis lesion. The radiation effects were marked on the first and third day of irradiation and the effects were decreased after seventh day and showed capillary regeneration.

  • PDF

Comparative Study of the Effective Dose from Panoramic Radiography in Dentistry Measured Using a Radiophotoluminescent Glass Dosimeter and an Optically Stimulated Luminescence Detector

  • Lee, Kyeong Hee;Kim, Myeong Seong;Kweon, Dae Cheol;Choi, Jiwon
    • Journal of the Korean Physical Society
    • /
    • v.73 no.9
    • /
    • pp.1377-1384
    • /
    • 2018
  • Accurate measurement of the absorbed dose and the effective dose is required in dental panoramic radiography involving relatively low energy with a rotational X-ray tube system using long exposures. To determine the effectiveness of measuring the irradiation by using passive dosimetry, we compared the entrance skin doses by using a radiophotoluminescent glass dosimeter (RPL) and an optically stimulated luminescence detector (OSL) in a phantom model consisting of nine and 31 transverse sections. The parameters of the panoramic device were set to 80 kV, 4 mA, and 12 s in the standard program mode. The X-ray spectrum was applied in the same manner as the panoramic dose by using the SpekCalc Software. The results indicated a mass attenuation coefficient of $0.008226cm^2/g$, and an effective energy of 34 keV. The equivalent dose between the RPL and the OSL was calculated based on a product of the absorbed doses. The density of the aluminum attenuators was $2.699g/cm^3$. During the panoramic examination, tissue absorption doses with regard to the RPL were a surface dose of $75.33{\mu}Gy$ and a depth dose of $71.77{\mu}Gy$, those with regard to the OSL were surface dose of $9.2{\mu}Gy$ a depth dose of $70.39{\mu}Gy$ and a mean dose of $74.79{\mu}Gy$. The effective dose based on the International Commission on Radiological Protection Publication 103 tissue weighting factor for the RPL were $0.742{\mu}Sv$, $8.9{\mu}Sv$, $2.96{\mu}Sv$ and those for the OSL were $0.754{\mu}Sv$, $9.05{\mu}Sv$, and $3.018{\mu}Sv$ in the parotid and sublingual glands, orbit, and thyroid gland, respectively. The RPL was more effective than the OSL for measuring the absorbed radiation dose in low-energy systems with a rotational X-ray tube.

A Study on the Environmental Condition and Safety in Dental Radiography Room (치과방사선 촬영실의 환경 및 안전성에 관한 연구)

  • Park, Il-Soon;Lee, Kyung-Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.4 no.1
    • /
    • pp.49-64
    • /
    • 2004
  • This study is designed to conduct a questionnaire research into the safety control and the actual condition of radiography by working with dentistry belonging to university hospitals, dental hospitals and dental clinics for three months ranging from August, 2003 to October, 2003. The researcher came to the following conclusions. 1. The research on the current condition of possessed radiational equipment shows that 61.2 percent of the subjects had one intraoral radiation medicine and that 70.1 percent of the subjects had more than one extraoral radiation medicine and that 37.3 percent of the subjects had more than one digital radiation medicine. 2. Most of intraoral radiography (82.1%) was conducted by dental hygienists, and 7.5 percent of intraoral radiography was conducted by nurse aids. On the other hand, most of extraoral radiography (76.6%) was conducted by dental hygienists and digital radiography was conducted by dental hygienists(60.6%), dentists(32.0%) and radiographer(80.0%). 3. The less-than 1-meter-long distance between cone and the radiographer accounted for 44.8 percent. And the more-than 1.6-meter-long distance accounted for no more than 13.4 percent. The exposure time per standard film which was adjusted to each part accounted for 71.6 percent. Fixing the film on the part of healthy patients accounted for 76.1 percent. Fixing the film of elderly patients and children patients by the radiographer accounted for 43.3 percent. 4. The average daily photographing frequency of standard films stood at six to ten pieces(31.3%), and the average weekly photographing frequency of bitewing films stood at less than one piece(47.8%), and the dentistries where bitewing films were not employed accounted for 25.4%. The subjects whose average weekly photographing freqeuncy of occlusal films stood at less than a piece accounted for 59.7 percent. The dentistries whose average weekly photographing frequency of pediatric films stood at one to five pieces accounted for 41.8 percent. In case of panorama & cephalo, one to five pieces on a weekly average accounted for 36.2 percent. The dentistries whose average daily photographing frequency of digital radiation medicine stood at less than 1 piece accounted for 40.0 percent. 5. The research on the use of protective clothes shows that pregnant ·women only accounted for 31.3 percent. In regard to the use of protective clothes in case of the radiographers fixing films, the cases where no protective clothes were employed accounted for 88.1 percent. The reason was said to he attributable to the trouble related to wearing the clothes(54.2%). 6. The survey on the measurement of exposure dose shows that the cases where no measurement was made accounted for 76.1 percent. As far as the measurement methods of exposure dose was concerned, the employment of film badge accounted for 68.8 percent. The subjects turned out to conduct measurement of exposure dose every third month, which accounted for 43.8 percent. The barriers to the measurement of measurement of exposure dose were attributable to the recognition that a little amount of exposure dose need not be measured(29.9%). 7. The survey on the distinction of radiation rooms and clinic rooms reveals that the cases where radiation rooms exclusively existed accounted for 67.2 percent. 43.3 percent of the subjects turned out to have only one protective garment, and 49.3 percent of the subjects proved to conduct a periodical checkup of radiational equipment. The survey on the examination certificates of radiational generators and protective facilities indicates that 80.6 percent of the subjects had the certificates. The research also shows that the subjects with the marks indicating the radiational areas accounted for 70.1 percent. And trustees turned out to handle developing solutions and fixing solutions.

  • PDF