• 제목/요약/키워드: dentistry radiation

검색결과 301건 처리시간 0.023초

MC3T3-E1 조골세포주의 osteonectin과 bone sialoprotein mRNA (Effects of irradiation on the mRNA expression of osteonectin and bone sialoprotein in MC3T3-E1 osteoblastic cell line)

  • 하쌍용;강기현;이상래;권기정;고광준
    • Imaging Science in Dentistry
    • /
    • 제34권2호
    • /
    • pp.99-106
    • /
    • 2004
  • Purpose: To investigate the effects of irradiation on the phenotypic expression of the MC3T3-El osteoblastic cell line, especially on the osteonectin and bone sialoprotein. Materials and Methods: Cells were irradiated with a single dose of 0.5, 1, 4 and 8 Gy at a dose rate of 5.38 Gy/min using Cs-I37 irradiator. After specimens were harvested, total RNA was extracted on the 3rd, 7th, 14th, 21st day after irradiation. The total RNA was reverse-transcribed and the resulting cDNAs were subjected to amplification by PCR with a pair of primers. Results: The irradiated cells showed a dose-dependent increase in osteonectin mRNA expression when compared with the unirradiated control group. The irradiated cells showed no difference in bone sialoprotein mRNA expression when compared with the unirradiated control group. In accordance with the duration of culture period after irradiation, the level of osteonectin mRNA expression showed no difference, but it increased a little at the 21st day in the 4 and 8 Gy exposure groups. In the case of bone sialoprotein, however, the level of mRNA expression increased significantly at the 3rd and 7th day after irradiation, but it showed no difference at the 14th and 21st day when compared with the control group. Conclusion: These results showed that each single dose of 0.5, 1, 4 and 8 Gy influenced the mRNA expression of osteonectin and bone sialoprotein at the calcification stage of osteoblastic cells, suggesting that single dose of irradiation affected the osteoblastic bone formation at the cell level.

  • PDF

하악 무치악 부위의 임플란트 이식을 위한 전산화단층촬영 영상의 비교 평가 (Comparative evaluation of computed tomography for dental implants on the mandibular edentulous area)

  • 선경훈;정호걸;박혁;박창서;김기덕
    • Imaging Science in Dentistry
    • /
    • 제39권1호
    • /
    • pp.27-33
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate the clinical usefulness of the recently developed multi-detector computed tomography and cone beam computed tomography in pre-operative implant evaluation, by comparing them with the single detector computed tomography, already confirmed for accuracy in this area. Materials and Methods: Five partially edentulous dry human mandibles, with $1{\times}1mm$ gutta percha cones, placed in 5mm intervals posterior to the mental foramen on each side of the buccal part of the mandible, were used in this study. They were scanned as follows: 1) Single detector computed tomography: slice thickness 1mm, 200mA, 120kV 2) Multi-detector computed tomography: slice thickness 0.75mm, 250mA, 120kV 3) Cone beam computed tomography: 15mAs, 120kV Axial images acquired from three computed tomographies were transferred to personal computer, and then reformatted cross-sectional images were generated using V-Implant $2.0^{(R)}$ (CyberMed Inc., Seoul, Korea) software. Among the cross-sectional images of the gutta perch a cone, placed in the buccal body of the mandible, the most precise cross section was selected as the measuring point and the distance from the most superior border of the mandibular canal to the alveolar crest was measured and analyzed 10 times by a dentist. Results: There were no significant intraobserver differences in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). There were no significant differences among single detector computed tomography, multi-detector computed tomography and cone beam computed tomography in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). Conclusion: Multi-detector computed tomography and cone beam computed tomography are clinically useful in the evaluation of pre-operative site for mandibular dental implants, with consideration for radiation exposure dose and scanning time.

  • PDF

저출력 레이저가 기계적 노출치수에 미치는 영향에 관한 연구 (A STUDY OF THE EFFECTS OF THE LOW POWER DENSITY LASER ON THE MECHANICALLY EXPOSED PULP)

  • 박동성;임성삼
    • Restorative Dentistry and Endodontics
    • /
    • 제14권1호
    • /
    • pp.109-118
    • /
    • 1989
  • The purpose of this study was to investigate the bio-stimulating effect of low power density laser radiation on the mechanically exposed pulp. Class V cavities on dog's teeth were prepared and the pulps were mechanically exposed with a round bur. In control group, the exposed pulps were capped with $Ca(OH)_2$ powder and the cavities were sealed with Z.O.E.. In experimental group A, the pulps were irradiated with GaA1As laser for 5 minutes and then they were treated the same as control group. In experimental group B, the exposed pulps were covered by aluminum foil and sealed with Z.O.E. after they were irradiated with the laser as the experimental group A. In the all groups, the pulps were histopathologically observed at the time intervals of 1, 2 and 3 week after experiment and the results were statistically evaluated. The results were as follows: 1) In control and experimental groups, mild vascular congestion and bleeding was found in most of the specimens and for the new formation of dentin bridge, experimental group A had the most cases. The dentin bridge had discontinuous osteodentin like appearance without any dentinal tubules. Inflammatory cell infiltration consisted of acute and chronic inflammatory cell, and the formation of microabscess was also observed. 2) The degree of inflammatory cell infiltration was not significantly different among control group and experimental groups at 1 week, 2 week and 3 week. 3) The formation of new dentin bridge was not significantly different between control group and experimental group A at 1 week, but at 2 week and 3 week, experimental group A showed significantly more cases of new dentin formation than control groups. (P < 0.05). 4) Between control group and experimental group B, there was no significant difference in formation of the new dentin bridge at 1, 2 and 3 week. (P> 0.05). 5) There was no significant difference in formation of the new dentin bridge at 1 and 2 week between experimental group A and experimental group B, but at 3 week, the former significantly had more cases of new dentin bridge formation than the latter.(P < 0.05).

  • PDF

Lipopolysaccharide로 자극시킨 방사선 조사 치은 섬유아 세포에서 granulocytemacrophage colony-stimulating factor와 transforming growth factor-${\beta}1$ 생성 (PRODUCTION OF GM-CSF AND TGF-${\beta}1$ IN IRRADIATED HUMAN GINGIVAL FIBROBLASTS CULTURED WITH LIPOPOLYSACCHARIDE)

  • 김홍식;이성근;김광혁;김욱규;김종렬;정인교;양동규
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제28권3호
    • /
    • pp.169-174
    • /
    • 2002
  • Purpose: Irradiation in the oral cancer patients causes early and late complications such as intraoral mucositis and fibrosis, with a various expression of GM-CSF and TGF-${\beta}1$. The purpose of this study was to investigate the production of GM-CSF and TGF-${\beta}1$ by the irradiated human gingival fibroblasts cultivated with lipopolysaccharide. Materials and Methods: Irradiated (total dose, 60 Gy) human gingival fibroblasts were incubated with LPS. Culture supernatants that were collected at 24, 48, and 72 hours were assessed for GM-CSF and TGF-${\beta}1$ by enzyme-linked immunosorbent assay. Results: 1. GM-CSF production in nomal gingival fibroblasts was increased with incubation time, but decreased with incubation time in irradiated gingival fibroblasts. GM-CSF production in both normal and irradiated gingival fibroblasts induced with LPS was higher than the control. 2. TGF-${\beta}1$ production in normal gingival fibroblasts was decreased after 24 hours, but, it was increased until 48 hours in irradiated gingival fibroblasts. TGF-${\beta}1$ production in normal gingival fibroblasts exposed with LPS was higher than the control. Conversely, It was lower than the control in irradiated gingival fibroblasts exposed with LPS. Conclusion: This indicates that irradiation in gingival fibroblasts may play an important role in radiation-induced intraoral mucositis and fibrosis. However, LPS decreases the production of TGF-${\beta}1$ in the irradiated gingival fibroblasts.

인공타액에서 아말감의 부식거동에 관한 전기화학적 연구 (ELECTROCHEMICAL STUDY ON THE CORROSION BEHAVIOUR OF DENTAL AMALGAM IN ARTIFICIAL SALIVA)

  • 김영남;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제13권2호
    • /
    • pp.221-235
    • /
    • 1988
  • The purpose of this study was to observe characteristic properties through the polarization curves and EMPA images from 4 different types of amalgam obtained by using the potentiostats (EG & G PARC) & EPMA (Jeol JSM-35), to investigate the degree of corrosion of each phase of amalgam on the oxidation peak, and to identify corrosion products from the corroded amalgam by use of X-ray diffractometer(Rigaku). After each amlgam alloy and Hg were triturated as the direction of the manufacturer by means of the mechanical amalgamator(Shofu), the triturated mass was inserted into the cylindrical metal mold which was 12mm in diameter and 10mm in height and was condensed by means of routine manner. The specimen was removed from the mold and stored at room temperature for about 7 days. The standard surface preparation was routinely carried out. Anodic polarization measurement was employed to compare the corrosion behaviours of the amalgams in 0.9% saline solution(pH6.8~7.0) and artificial saliva (pH6.8~7.0) at $37^{\circ}C$. The open circuit potential was determined after 30 minutes' immersion of specimen in electrolyte and the potential scan was begun at the potential of 100mV cathodic from the corrosion potential. The scan rate was 1mV/sec and the surface area of amalgam exposed to the solution was 0.64$cm^2$ for each specimen. All the potentials reported are with respect to a saturated calomel electrode (SCE). EPMA images on the determined oxidation peaks of each amalgam in artificial saliva were observed. X-ray diffraction patterns of each sample were recorded before and after polarization in artificial saliva (Aristaloy, Caulk Spherical, Dispersalloy and Tytin: at +770mV, +585mV, +8.10m V and +680m V respectively) by use of a recording diffractometer. Nickel filtered Cu $K_{{\alpha}_1}$ radiation was used and sample was scanned at $4^{\circ}(2{\theta})/min.$ from $25^{\circ}$ to $80^{\circ}$. The following results were obtained. 1. Oxidation peak potential in artificial saliva shifted to more anodic direction than that in saline solution. 2. The corrosion potential of high copper amalgam was more anodic than the potential of low copper amalgam. 3. The current density was lower in artificial saliva than in saline solution. 4. One of the corrosion products, AgCl was identified by X-ray diffraction analysis. 5. ${\gamma}_2$ phase was the most susceptible to corrosion and e phase was stable in low copper amalgam and ${\eta}$' phase and Ag-Cu eutectic were susceptible to corrosion in high copper amalgam.

  • PDF

Characteristics of radiographic images acquired with CdTe, CCD and CMOS detectors in skull radiography

  • Queiroz, Polyane Mazucatto;Santaella, Gustavo Machado;Lopes, Sergio Lucio Pereira de Castro;Haiter-Neto, Francisco;Freitas, Deborah Queiroz
    • Imaging Science in Dentistry
    • /
    • 제50권4호
    • /
    • pp.339-346
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the image quality, diagnostic efficacy, and radiation dose associated with the use of a cadmium telluride (CdTe) detector, compared to charge-coupled device (CCD) and complementary metal oxide semiconductor(CMOS) detectors. Materials and Methods: Lateral cephalographs of a phantom (type 1) composed of synthetic polymer filled with water and another phantom (type 2) composed of human skull macerated with polymer coating were obtained with CdTe, CCD, and CMOS detectors. Dosimeters placed on the type 2 phantom were used to measure radiation. Noise levels from each image were also measured. McNamara cephalometric analysis was conducted, the dentoskeletal configurations were assessed, and a subjective evaluation of image quality was conducted. Parametric data were compared via 1-way analysis of variance with the Tukey post-hoc test, with a significance level of 5%. Subjective image quality and dentoskeletal configuration were described qualitatively. Results: A statistically significant difference was found among the images obtained with the 3 detectors(P<0.05), with the lowest noise level observed among the images obtained with the CdTe detector and a higher subjective preference demonstrated for those images. For the cephalometric analyses, no significant difference (P>0.05) was observed, and perfect agreement was seen with regard to the classifications obtained from the images acquired using the 3 detectors. The radiation dose associated with the CMOS detector was higher than the doses associated with the CCD (P<0.05) and CdTe detectors(P<0.05). Conclusion: Considering the evaluated parameters, the CdTe detector is recommended for use in clinical practice.

시험관내 A-253 세포주의 방사선 및 항암제 감수성에 관한 연구 (A STUDY ON THE RADIOSENSITIVITY AND CHEMOSENSITIVITY OF A-253 CELL LINE IN VITRO)

  • 이주현;황의환;이상래
    • 치과방사선
    • /
    • 제27권2호
    • /
    • pp.91-103
    • /
    • 1997
  • The purpose of this study was to aid in the prediction of tumor cell tolerance to radiotherapy and/or chemotherapy. For this study, cell surviving curves were obtained for human epidermoid carcinoma A-253 cell line using semiautomated MTT assay. 2,4,6,8,10 Gy were irradiated at a dose rate of 210 cGy/min using /sup 60/Co Irradiator ALDORADO 8. After irradiation, A-253 cell lines(2×10⁴cells/mil were exposed to bleomycin or cisplatin for 1 hour. The viable cells were determined for each radiation dose with/without 2 /lg/mi of drug at the 3rd day. And they were compared to control values. The results were obtained as follows : 1. The surviving curve with gentle slope was obtained after irradiation of 2, 4, 6, 8, 10 Gy on A-253 cell line. 2. The cytotoxicity of bleomycin or cisplatin at the concentration of 2㎍/ml was great on A-253 cell line. But, there was no significant difference between the cytotoxicity of bleomycin and that of cisplatin. 3. There were significant differences of surviving fractions after irradiation with 2㎍/mi of bleomycin compared with irradiation only on A-253 cell line. 4. There were significant differences of surviving fractions after irradiation with 2㎍/ml of cisplatin compared with irradiation only on A-253 cell line. 5. There were no significant differences of surviving fractions between the groups of irradiation with bleomycin and the groups of irradiation with cisplatin on A-253 cell line.

  • PDF

저출력 레이저 조사가 성견의 실험적 치주질환 치유에 미치는 영향에 관한 조직병리학적 연구 (THE HEALING EFFECTS OF LOW POWER DENSITY LASER TO THE EXPERIMENTAL PERIODONTITIS;HISTOPATHOLOGIC STUDY)

  • 김동운;이재현;정진형
    • Journal of Periodontal and Implant Science
    • /
    • 제23권1호
    • /
    • pp.16-26
    • /
    • 1993
  • In order to investigate the healing effect on inflammation and bone regeneration of low power density laser radiation in dogs, experimental periodontitis was made in dog mandibular 3rd, 4th premolars. All teeth were classified with four groups of two experimental group and control groups. The second group were irradiated on periodontitis site and the first group were control. The fourth group were irradiated on periodontitis site flap operation and the third group were flap control. Experimental groups were irradiated with GaAs low power density laser of pulse wave and continuous wave of 904nm every day by five days respectively and then control group and experimental groups were evaluated by histo-pathological study. The results were as follows : 1. Experimental periodontits site of dog were irradiated with GaAs low power laser results in reducing of pseudoepitheliomatous proliferation and inflammation at light microscope. 2. After irradiation with low power density laser, experimental groups were revealed that PDL forming activity were increased and newly formed collagen deposition were observed. 3. Low power density lsaer irradiation on experimental periodontits site after flap operation showed that decreasing of inflammation, reducing of osteoclast activity. Capillary proliferation, reduction of pseudoepitheliomatous proliferation. 4. After irradiation with low power density laser on flap experimental site, experimental groups were revealed that newly formed collagen in periodontal ligament and alveolar bone were detected on MT staining.

  • PDF

디지털 적외선 체열 검사를 사용한 하치조 신경 손상의 평가 (ASSESSMENT OF INFERIOR ALVEOLAR NERVE DAMAGE USING DIGITAL INFRARED THERMOGRAPHIC IMAGING)

  • 이지연;이재훈;김철환
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제30권6호
    • /
    • pp.488-496
    • /
    • 2004
  • Oral & Maxillofacial surgery can lead to complications that result in abnormal sensation or movement. Inferior alveolar nerve(IAN) injury can result in dysesthesia, paresthsia of the lower lip and chin, so patients presenting with IAN damage suffer from sensory loss. But diagnosis of the nerve injury is largely limited to the subjective statements made by the patient. Distribution of sympathetic nerves parallels the distribution of the somatosensory nerves. Loss of sensory tone causes a concomitant loss of sympathetic activity, resulting in vasodilation of the cutaneous blood vessels that demonstrates greater heat loss. Digital infrared thermographic imaging(DITI) detects infra-red radiation given off by body. DITI can detect minute difference in temperature from different parts of the body and translates the amount of heat into quantitative data. The area of different temperature correlated with pain or disease can be visualized by corresponding color. The objective of this study was to determine the efficacy of DITI in objectively assessing IAN injury. The 19 normal subjects and the 14 patients underwent DITI scan. The normal subjects received unilateral IAN block anesthesia with 2 ml of 2% lidocaine (IAN bolck group) to evaluate temporary alteration in nerve function. Patient group were patients with unilateral IAN damage (dysesthesia or paresthesia) after surgical treatment(Mn. 3rd molar Extraction, etc.). The surgical procedure performed within 6 months of test. The results were as follows. 1. No significant differences in temperature were found between left and right sides of the lower lip and chin in the control group. 2. Significant temperature differences were found between the anesthetized and non-anesthetized sides of the lower lip and chin in the IAN block group. 3. Significant temperature differences were found between the involved and uninvolved sides of the lower lip and chin areas of the experimental group. The results of the study show that DITI can be an useful and effective means of objectively assessing and visualizing IAN damage.

백서 연조직에 저수준 레이저 요법시 창상 치유기전에 관한 연구 (EFFECT OF LOW LEVEL LASER THERAPY ON HEALING OF OPEN SKIN WOUNDS IN RATS)

  • 유상우;김경욱;이재훈;김창진
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제26권5호
    • /
    • pp.481-489
    • /
    • 2000
  • This research was focused on overall examination of tissue alteration, wound healing promotion. After the hair on the dorsal surface was shaved, $5{\times}5mm$ oval skin defect was formed. Experimental wounds of right side were irradiated on every day for 90 second with Ga-Al-As semi-conductor laser. Left side wounds served as control group. The rats were sacrificed on the 1st, 3rd, 5th, 7th, 14th, 21th day. For light microscopically, parafin section were stained with H&E, MT. The outcomes were as follows : 1. On 1st day, experimental and control group were seen acute inflammatory cell infiltration, edema. 2. On the 3rd days, both groups were seen crust development, collagen, blood vessel proliferation. 3. On the 5th days, experimental group were reduced edema and inflammatory cell infiltration than control group. 4. On the 7th days, both groups were observed edema, inflammatory cell infiltration disappearance and keratinocytes motility from wound defect. 5. On the 14th days, experimental group appeared collagen, blood vessel proliferation and hair follicle than control group. 6. On the 21th days, both groups were seen normal status re-epithelization. According to the above results, The wound-healing stimulated by laser radiation involves an increased rate of epithelial growth. LLLT was confirmed that it has fibroblast, blood vessel proliferation, influence initial wound healing process.

  • PDF