CAD/CAM 및 카피밀링 시스템을 이용하여 제작한 구치부 3-유닛 고정성 국소의치의 파절강도 (Fracture Strength of All-Ceramic 3-Unit Fixed Partial Dentures Manufactured by CAD/CAM and Copy-Milling Systems)

  • 강후원;김희진;김장주;고명원
    • 대한치과기공학회지
    • /
    • 제34권2호
    • /
    • pp.95-103
    • /
    • 2012
  • Purpose: Fracture strength of all-ceramic 3-unit fixed partial dentures manufactured by CAD/CAM and copy-milling systems were evaluated. Methods: Zirconia cores were made by milling the pre-sintered zirconia block by CAD/CAM or copy milling method followed by subsequent sintering. By building-up the corresponding porcelains on the core, all-ceramic bridges were fabricated, and those were evaluated in comparison with PFM fixed partial denture. Results: During the flexural test of the 3-unit PFM bridge, the porcelain started to chip or break at 507.28(${\pm}62.82$)kgf and the metal framework did not break until the maximum load level of 800kgf which was set in the testing instrument of this study. However, among all-ceramic restoration test groups, Everest(EV) group showed a peeling off or breakage of the porcelain from 365.64(${\pm}64.96$)kgf and the core was broken at 491.77(${\pm}55.62$)kgf. Those values of Zirkonzahn(ZR) were 431.03(${\pm}58.47$)kgf and 602.74(${\pm}48.44$)kgf, respectively. The break strength of the porcelain of PFM(PM) group was significantly higher than that of EV (p<0.05) group and there was no significant difference when comparing to that of ZR (p>0.05). ZR group showed higher break strength than that of EV group however there was no significant difference (p>0.05). The break strength of cores were in the increasing order of EV < ZR < PM (p<0.05). Conclusion: We could find that even though the PM group fractured at much higher value than all-ceramic cores, the breakage values of the porcelain of PM group with crack formation or delamination, which will be regarded as clinical failure, was significantly higher than that of EV group and not significantly higher than that of ZR group at p-values of 0.05. The break strength of ZR group was higher than that of EV group at an insignificant level(p>0.05).

Lithium Disilicate (IPS e.max CAD) 코어와 전장 도재 사이의 전단결합강도에 관한 연구 (A Study on the Shear Bond Strength of Veneering Ceramics to the Lithium Disilicate (IPS e.max CAD) Core)

  • 김기백;김재홍
    • 치위생과학회지
    • /
    • 제13권3호
    • /
    • pp.290-295
    • /
    • 2013
  • 본 연구는 심미 치과보철물에 사용되는 지르코니아, lithium disilicate 코어와 전장도재 사이의 전단결합강도를 측정하고, 금속도재관을 대조군으로 설정하여 비교하였다. 직사각기둥 모양의 시편을 각각 10개씩 제작하여 코어와 전장도재 사이의 전단결합강도를 측정한 후 파절면의 양상을 실체현미경을 통해 관찰하였다. 제한된 조건하에 시행된 실험을 통하여 심미보철 분야에 널리 적용되고 있는 치과용세라믹 코어의 전단결합강도를 확인하였으며, 측정 후 비교분석된 결과는 다음과 같다. 2종의 치과용 세라믹 코어와 전장도재 간에 전단결합강도는 금속도재관의 전단결합강도와 유의한 차이가 있었다 (p<0.05). 본 실험 결과를 토대로 ZB군은 임상적으로 받아들여지는 전단결합강도 범위 내 분포를 보이지만, LB군은 임상허용 범위에 못 미치는 결과값을 보였다. 금속도재관과 달리 지르코니아, lithium disilicate 전부도재관은 모두 혼합형 파절양상을 보였다. 결론적으로 전단결합강도 실험에 사용된 시편이 임상적인 치과보철물의 형태와는 달리 실험을 위한 시편의 형태로 제작되어 임상적 결과를 반영하지 못했으며 구강 내의 상황과도 다르다는 한계점을 가지고 있다. 추후에는 이를 보완하여 치과보철물과 유사한 형태의 시편을 이용한 전단결합 강도의 측정과 구강 내 조건을 고려한 추가 실험이 필요하다고 생각된다.

Mechanical behavior and microstructural characterization of different zirconia polycrystals in different thicknesses

  • Arcila, Laura Viviana Calvache;Ramos, Nathalia de Carvalho;Campos, Tiago Moreira Bastos;Dapieve, Kiara Serafini;Valandro, Luiz Felipe;de Melo, Renata Marques;Bottino, Marco Antonio
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권6호
    • /
    • pp.385-395
    • /
    • 2021
  • PURPOSE. To characterize the microstructure of three yttria partially stabilized zirconia ceramics and to compare their hardness, indentation fracture resistance (IFR), biaxial flexural strength (BFS), and fatigue flexural strength. MATERIALS AND METHODS. Disc-shaped specimens were obtained from 3Y-TZP (Vita YZ HT), 4Y-PSZ (Vita YZ ST) and 5Y-PSZ (Vita YZ XT), following the ISO 6872/2015 guidelines for BFS testing (final dimensions of 12 mm in diameter, 0.7 and 1.2 ± 0.1 mm in thicknesses). Energy-dispersive X-ray spectroscopy (EDX), X-ray diffraction (XRD) and scanning electron microscopy (SEM) analyses were performed, and mechanical properties were assessed by Vickers hardness, IFR, quasi-static BFS and fatigue tests. RESULTS. All ceramics showed similar chemical compositions, but mainly differed in the amount of yttria, which was higher as the amount of cubic phase in the diffractogram (5Y-PSZ > 4Y-PSZ > 3Y-TZP). The 4Y- and 5Y-PSZ specimens showed surface defects under SEM, while 3Y-TZP exhibited greater grain uniformity on the surface. 5Y-PSZ and 3Y-TZP presented the highest hardness values, while 3Y-TZP was higher than 4Y- and 5Y-PSZ with regard to the IFR. The 5Y-PSZ specimen (0.7 and 1.2 mm) showed the worst mechanical performance (fatigue BFS and cycles until failure), while 3Y-TZP and 4Y-PSZ presented statistically similar values, higher than 5Y-PSZ for both thicknesses (0.7 and 1.2 mm). Moreover, 3Y-TZP showed the highest (1.2 mm group) and the lowest (0.7 mm group) degradation percentage, and 5Y-PSZ had higher strength degradation than 4Y-PSZ group. CONCLUSION. Despite the microstructural differences, 4Y-PSZ and 3Y-TZP had similar fatigue behavior regardless of thickness. 5Y-PSZ had the lowest mechanical performance.

타액으로 오염된 지르코니아 수복물의 접착강도에 세척 방법들이 미치는 영향 (The effect of cleaning methods on bond strength of zirconia after saliva contamination)

  • 심영보;최안나;손성애;정경화;권용훈;박정길
    • 대한치과재료학회지
    • /
    • 제44권1호
    • /
    • pp.61-68
    • /
    • 2017
  • 본 연구는 MDP 적용 후 타액으로 오염된 지르코니아 수복물을 다양한 방법으로 세척한 후 전단결합강도를 비교하여 세척방법이 결합강도에 미치는 영향을 알아보고자 한다. 80개의 지르코니아 시편을 8개의 군으로 나누었다. 모든 시편에 MDP를 적용한 후 한 개의 군(음성대조군)을 제외하고 나머지 군에 타액을 적용하여 오염시켰다. 그 중 한 개의 군(양성대조군)은 타액 오염 후 세척하지 않고 즉시 레진 시멘트를 이용하여 접착하였다. 나머지 6개의 군의 시편을 물을 이용하여 세척하고 MDP를 적용하거나(물+MDP) 적용하지 않은 군(물), Ivoclean으로 세척하고 MDP를 적용하거나(IVOCLEAN+MDP) 적용하지 않은 군(IVOCLEAN), 차아염소산나트륨을 이용하여 세척하고 MDP를 적용하거나(NaOCl+MDP) 적용하지 않은 군(NaOCl)으로 분류하였다. 모드 시편은 $37^{\circ}C$ 증류수에 24시간 저장한 후 전단강도를 측정하였고, ANOVA, Tukey's post hoc test를 이용하여 전단강도를 분석하였고, MDP의 재적용 여부가 미치는 영향에 대해서는 student t-test를 이용하여 통계분석하여 다음의 결과를 얻었다. 양성대조군이 가장 낮은 전단강도 값을 나타냈으며, 물군과 NaOCl군이 낮은 전단강도 값을 나타내며 양성대조군과 유의한 차이가 없었다. IVOCLEAN군은 물군과 NaOCl군보다 유의하게 높은 전단강도 값을 나타내며 음성대조군과 유의한 차이가 없었다. MDP를 재적용한 것은 물과 차아염소산나트륨을 이용한 경우 MDP를 재적용하지 않은 경우와 유의한 차이를 나타내면서 음성대조군과 유의한 차이가 없었다. Ivoclean을 사용한 경우 MDP 재적용 여부와는 관계없이 음성대조군과 유의한 차이가 없었다. 결론적으로, 세척방법에 따라 전단강도는 영향을 받으며, MDP 재적용 여부와는 관계없이 Ivoclean이 효과적이며, 물과 차아염소산나트륨 사용시에는 MDP를 다시 적용해주는 것이 결합강도를 향상시킬 수 있는 방법으로 사료된다.

CAD/CAM system을 이용한 Zirconia수복

  • 박은진
    • 대한치과의사협회지
    • /
    • 제47권12호
    • /
    • pp.817-822
    • /
    • 2009
  • 치과보철학 분야에서 컴퓨터를 이용한 기술의 발달로 치료 계획, 수술, 보철물 수복에 이르기까지 CAD-CAM의 광범위한 적용이 가능해지고 있으며, 비용과 시간의 절약으로 효율적인 진료가 가능하다는 점을 인지한 많은 회사들의 투자로 다양한 프로그램과 기계들이 소개되고 있다. 그러나, 이렇게 활발한 제품 개발에도 불구하고 아직 실제 임상으로의 적용은 보편화되었다고 보기는 어려운데, 가장 큰 이유는 정확도에 대한 의심과 복잡하다고 느껴지는 초기의 숙련 과정에 있다고 하겠다. 제작회사들의 보고에 따르면 컴퓨터를 이용하여 디자인하고 절삭하는 것이 기존의 주조 기술보다 더 정교하다고 하였으나, 실제 임상에서는 미세한 오차를 간과한 데서 오는 최종 결과물과의 차이를 얘기하는 임상가들이 있는 것이 현실이다. 또, 그 사용 재료에 있어서도 초기 티타늄 금속 재료에 이어 심미적 요구를 위한 알루미나, 보다 향상된 강도를 가진 지르코니아에 이르기까지 다양한 재료들이 쏟아져 나오고 있다. 이에 본 논문에서는 다양한 CAD-CAM 시스템 중 대표적인 것 중의 하나인 Nobel Biocare사의 $Procera^{(R)}$ 시스템을 중심으로 지르코니아 수복물에 관한 최신 정보를 제공하며, 그 다양한 치과적 적용을 누구나 쉽고 정확하게 사용할 수 있는 임상 증례와 함께 소개함으로써 실제 임상 적용에 도움이 되고자 한다.

  • PDF

Influence of preparation depths on the fracture load of customized zirconia abutments with titanium insert

  • Joo, Han-Sung;Yang, Hong-So;Park, Sang-Won;Kim, Hyun-Seung;Yun, Kwi-Dug;Ji, Min-Kyung;Lim, Hyun-Pil
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권3호
    • /
    • pp.183-190
    • /
    • 2015
  • PURPOSE. This study evaluated the fracture load of customized zirconia abutments with titanium insert according to preparation depths, with or without 5-year artificial aging. MATERIALS AND METHODS. Thirty-six identical lithium disilicate crowns (IPS e.max press) were fabricated to replace a maxillary right central incisor and cemented to the customized zirconia abutment with titanium insert on a $4.5{\times}10$ mm titanium fixture. Abutments were fabricated with 3 preparation depths (0.5 mm, 0.7 mm, and 0.9 mm). Half of the samples were then processed using thermocycling (temperature: $5-55^{\circ}C$, dwelling time: 120s) and chewing simulation (1,200,000 cycles, 49 N load). All specimens were classified into 6 groups depending on the preparation depth and artificial aging (non-artificial aging groups: N5, N7, N9; artificial aging groups: A5, A7, A9). Static load was applied at 135 degrees to the implant axis in a universal testing machine. Statistical analyses of the results were performed using 1-way ANOVA, 2-way ANOVA, independent t-test and multiple linear regression. RESULTS. The fracture loads were $539.28{\pm}63.11$ N (N5), $406.56{\pm}28.94$ N (N7), $366.66{\pm}30.19$ N (N9), $392.61{\pm}50.57$ N (A5), $317.94{\pm}30.05$ N (A7), and $292.74{\pm}37.15$ N (A9). The fracture load of group N5 was significantly higher than those of group N7 and N9 (P<.017). Consequently, the fracture load of group A5 was also significantly higher than those of group A7 and A9 (P<.05). After artificial aging, the fracture load was significantly decreased in all groups with various preparation depths (P<.05). CONCLUSION. The fracture load of a single anterior implant restored with lithium disilicate crown on zirconia abutment with titanium insert differed depending on the preparation depths. After 5-year artificial aging, the fracture loads of all preparation groups decreased significantly.

내부연결 임플란트용 타이타늄 소켓을 이용한 지르코니아 지대주에서 열순환이 나사풀림에 미치는 영향: 예비연구 (The effect of a titanium socket with a zirconia abutment on screw loosening after thermocycling in an internally connected implant: a preliminary study)

  • 경규영;차현석;이주희
    • 구강회복응용과학지
    • /
    • 제33권2호
    • /
    • pp.114-118
    • /
    • 2017
  • 목적: 이 연구의 목적은 타이타늄 구성요소를 가진 지르코니아 지대주가 내부연결 임플란트에 사용되었을 때 나사 풀림에 대해 알아보는 것이다. 열순환 후 타이타늄 소켓을 가진 지르코니아 지대주와 타이타늄 지대주의 나사 풀림과 제거력을 비교 분석하였다. 연구 재료 및 방법: 내측연결 임플란트와 내측연결 타이타늄 지대주, 타이타늄 소켓을 가진 외측연결 지르코니아 지대주를 준비하였다. 내부연결형 임플란트에 5개의 타이타늄 지대주를(대조군), 타이타늄 소켓을 가진 5개의 지르코니아 지대주(실험군)를 각각 연결하고 30 Ncm의 토크로 조인 후 열순환 처리 전후의 지대주 나사 제거력을 측정하였다. 각 시편들은 열순환 장치의 수조에서 $5^{\circ}C$$55^{\circ}C$의 물에 60초씩 교대로 2,000회의 열순환을 시행하였다. 각 시편의 나사 풀림을 조사하고 열순환 전후에 나사 제거력을 통계학적으로 분석하였다. 결과: 두 그룹 모두에서 열순환 후 지대주 나사 풀림을 보이지 않았다. 열순환 전후의 나사 제거력 차이는 대조군에서 $-1.34{\pm}2.53Ncm$, 실험군에서 $-1.26{\pm}2.06Ncm$ 로 나타났다. 독립표본 T 통계분석 결과 두 군간에 유의한 차이를 보이지 않았다(P > 0.05). 결론: 이 실험의 결과 내에서 내부연결 임플란트를 위한 지르코니아 지대주 내 타이타늄 소켓이 열순환 후 지대주 나사풀림에 타이타늄 지대주와 비교하여 유의한 영향을 나타내지 않았다.

전부도재수복물을 위한 수종의 코어 세라믹의 반투명도 및 색 안정성 (Translucency and Color Stability of Various Core Ceramics for All-Ceramic Restoration)

  • 오상천;이해형;신미란;박광수
    • 구강회복응용과학지
    • /
    • 제23권2호
    • /
    • pp.157-170
    • /
    • 2007
  • Purpose: This investigation was designed to determine the translucency and color stability of various core ceramics for all-ceramic restoration using the CIE $L^*a^*b^*$ system. Material and Methods: IPS e.max Press ceramic(Ivoclar-Vivadent, Liechtenstein), $LAVA^{TM}$ All Ceramic(3M-Espe, Germany), Cercon Smart Ceramic(Dentsply, Germany), and Z-match Ceramic(DentAim, Korea) were used for this study. For the specimens of zirconia oxide ceramics, the as-sintered cylindrical blanks($11.0{\times}25.0mm$) were machined into the shape of a disk(0.4, 0.8, 1.5 mm in thickness, 10 mm in diameters) with a diamond grind machine. The IPS e.max Press specimens ($0.8{\times}10mm$) were fabricated using the "lost wax" technique. CIE $L^*a^*b^*$ coordinates and light transmission were recorded for each specimen with a spectrophotometer(CM-2600d, Minolta, Japan). Color differences were calculated using the equation, ${\Delta}E^*ab=[({\Delta}L^*)2+({\Delta}a^*)2+({\Delta}b^*)2]1/2$. Results: The results were obtained as follows: 1. The most translucent group was IPS e.max Press ceramic that is a glass-ceramic, and $Lava^{TM}$ and Z-match ceramic were more translucent than Cercon Smart ceramic in zirconia ceramic group. 2. In the all groups, there was no significant translucent change after 6 times heat-treatments required to make a final restoration. 3. Colored zirconia was showed more yellowish and dark than uncolored zirconia. 4. After heat-pressing, IPS e.max Press ceramic was showed high ${\Delta}E^*ab$ value(4.1 of eM1, 6.8 of eM2) that means to be more whiter than before heat-pressing. However, there was no color change after additive heat treatments for final restoration. 5. In the colored zirconia groups, there was no significant color change after some heat-treatments required to make a final restoration.

임플란트 지대주 종류와 동적하중이 고정체와 지대주의 미세간극에 미치는 영향 (The Effect of Types of Abutment and Dynamic Loading on Microgap between Implant Fixture and Abutment)

  • 오병두;최유성;신수연
    • 구강회복응용과학지
    • /
    • 제26권4호
    • /
    • pp.389-403
    • /
    • 2010
  • 이전부터 사용된 티타늄, 금합금 지대주 및 최근 사용이 급증한 지르코니아 지대주와 임플란트의 계면에 대한 비교 연구와 동적하중이 계면에 미치는 영향에 관한 연구가 많지 않은 실정이다. 본 연구에서 지대주 종류와 동적 하중에 따른 미세간극의 차이를 주사전자현미경 분석을 통하여 비교평가 하였다. USII ${\phi}3.75{\times}11.5mm$ (Osstem Co., Seoul, Korea) 티타늄 임플란트에 티타늄 지대주, 지르코니아 지대주, 주조 금합금 (UCLA plastic) 지대주를 각 군당 7개씩, 30Ncm의 조임회전력으로 연결하였다. 25-250N의 sine형 동적하중을 장축 방향에서 $30^{\circ}$ 경사로 $10^5$회 시행하였다. 하중 전후에 계면의 미세간극을 순측, 구개측, 근심측, 원심측 부위에서 측정하였고, 그 결과 동적 하중으로 인한 통계적 유의성은 없었다. 지대주 종류에 따른 미세간극을 비교한 결과, 동적하중 시행 전후 모두 UCLA 군과 티타늄 군, UCLA 군과 지르코니아 군 사이에 통계적으로 유의한 차이를 보였다(p<0.05). 티타늄 군과 지르코니아 군 사이에는 유의한 차이를 보이지 않았다. UCLA 지대주는 정밀 연삭된 티타늄, 지르코니아 지대주 보다 더 큰 미세간극을 보였고 $10^5$회 동적하중은 미세간극에 영향을 미치지 않았다.

소결 전 지르코니아 표면처리와 라이너 사용에 따른 지르코니아와 열가압성형도재의 전단결합강도 (Effects of Pre-Sintering Surface Treatment and Liner Application on the Shear Bond Strength of Zirconia and Pressable Ceramic)

  • 이광영;조미향;최성민
    • 대한치과기공학회지
    • /
    • 제37권3호
    • /
    • pp.121-127
    • /
    • 2015
  • Purpose: This study was intended to investigate the effect of applying liner for chemical bonding and physical surface roughness created on zirconia by using a sandpaper before sintering on the bond strength between the two materials. Methods: Zirconia blocks were cut using a low-speed cutter. Plate-shaped specimen($6mm{\times}6mm{\times}3mm$) was fabricated by sintering after giving surface roughness according to four kinds of sandpapers. Depending on whether or not to use liner, 60 specimens were divided into two groups ZN(non-liner), ZL(liner), and the two groups were subdivided into four groups respectively in accordance with sandpaper used, totaling eight groups (n=10). The surface roughness (Ra) values and shapes before sintering were observed, and shear bond strength after pressing ceramic plasticity was measured with a universal testing machine. For a test of the significance, a one-way ANOVA was performed, and Tukey's multiple comparison test was conducted. Results: The observation of the surface roughness was SB04($2.22{\pm}1.16{\mu}m$), SB08($2.98{\pm}0.33{\mu}m$), SB12($2.44{\pm}1.32{\mu}m$), SB20($2.34{\pm}0.59{\mu}m$) and SA04($2.34{\pm}0.67{\mu}m$), SA08($1.28{\pm}0.90{\mu}m$), SA12($2.03{\pm}1.60{\mu}m$), SA20($2.19{\pm}1.73{\mu}m$). In the case of ZN Group, the shear bond strength was ZN04($23.26{\pm}3.83MPa$), ZN08($21.76{\pm}2.33MPa$), ZN12($20.49{\pm}3.01MPa$), ZN20($24.98{\pm}4.22MPa$)(p<0.05). As for ZL Group, the shear bond strength was ZL04($25.09{\pm}5.67MPa$), ZL08($22.98{\pm}2.26MPa$), ZL12($21.54{\pm}5.70MPa$), ZL20($23.98{\pm}3.23MPa$)(p<0.05). Conclusion: The research results showed that the bond strength of Zirconia core and Pressing ceramic was further improved by physical surface treatment before sintering, rather than by chemical bonding through liner surface treatment.