• 제목/요약/키워드: dental resin composite

검색결과 521건 처리시간 0.025초

Effect of pH and storage time on the elution of residual monomers from polymerized composites

  • Jeon, Cheol-Min;Kwon, Hyuk-Choon
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.561-562
    • /
    • 2003
  • pH varies in the oral environment and on tooth surfaces. The surface of a plaque covered resinous restoration has a low pH. In human dental plaque a number of acids are produced by bacterial metabolism. The predominant acids are acetic, propionic and lactic acids. These acids induced a surface swelling of restorative resin. The swelling cause formation of pores inside the resin matrix from which organic substances can be released, resulting in a mass loss. The purpose of this study was to qualitatively and quantitatively analyse the leached monomers of dental composites after storage in acetate buffer solution as a function of time by means of high performance liquid chromatography(HPLC) / mass spectrometer and further determine whether pH and time has any influence on the degradation behavior of composite restoration.(omitted)

  • PDF

복합레진의 색에 대한 이해 (Understanding of the color in composite resin)

  • 박정원
    • Restorative Dentistry and Endodontics
    • /
    • 제36권4호
    • /
    • pp.271-279
    • /
    • 2011
  • 임상에서 복합 레진을 이용하여 자연치를 재현하는 과정은 매우 어려우며 이를 위해서는 색과 사용하는 재료에 대한 충분한 이해가 필요하다. 복합 레진은 자연치와 화학적 조성과 미세구조가 다르기 때문에 광학적 특성도 다를 수 밖에 없다. 본 논문에서는 색에 대한 기본적인 지식과 색을 측정하는 장비에 대한 이해, 그리고 자연치의 색에 대한 분석을 살펴보고, shade tab의 정확도에 대한 평가, 복합 레진의 중합 전후의 색 변화, 수분과 물에 의한 영향, 미백제의 의한 영향 및 투명도, 유백광 성질(opalescence), 형광성(fluorescence)에 대해 알아보고자 하였다.

Endocrown restorations for extensively damaged posterior teeth: clinical performance of three cases

  • Tzimas, Konstantinos;Tsiafitsa, Maria;Gerasimou, Paris;Tsitrou, Effrosyni
    • Restorative Dentistry and Endodontics
    • /
    • 제43권4호
    • /
    • pp.38.1-38.9
    • /
    • 2018
  • The restoration of endodontically treated teeth (ETT) with more than one cusp missing and thin remaining walls is challenging for the general practitioner. The use of posts combined with full coverage restorations is a well-established approach, yet not following the minimal invasive principles of adhesive dentistry. Endocrowns are indirect monoblock restorations that use the pulp chamber of the ETT for retention. In this study the fabrication of 4 endocrowns and their clinical performance will be discussed. Two clinical cases include computer-aided design/computer-aided manufacturing manufactured molar endocrowns (one feldspathic ceramic and one hybrid composite-ceramic restoration) and the other two are dental laboratory manufactured resin composite premolar endocrown restorations. The modified United States Public Health Service criteria were used to assess the clinical behavior of the restorations at different follow up periods. Endocrown restorations present a satisfactory clinical alternative, either by the use of resin composite or glass ceramic and hybrid materials. Specific guidelines with minimal alterations should be followed for an endocrown restoration to be successful. Due to limited evidence regarding the long term evaluation of this restorative technique, a careful selection of cases should be applied.

Comparative Analysis of Stress Distribution in Composite Resin Brackets with Metal Slot of Permanent Maxillary Central Incisor Using the Finite Element Method: A Pilot Study

  • Im, Jae-Jung;Song, Jae-Joon;Kim, Nan-Hee;Heo, Jin-Young;Jung, Gyu-Un;Hwang, Kyung-Gyun;Park, Chang-Joo
    • Journal of Korean Dental Science
    • /
    • 제4권2호
    • /
    • pp.46-51
    • /
    • 2011
  • Purpose: For aesthetic reasons, composite resin brackets are widely used. However, related studies are rare. This pilot study sought to compare the stress distributions in two commercially available composite resin brackets with metal slot. Materials and Methods: Two commercially available resin brackets -- full-metal slot resin bracket (fSRB) and partial-metal slot resin bracket (pSRB) with straight wire appliance dimension of $0.022{\times}0.028$ in -- were selected. In each bracket, 3-dimensional finite element models were constructed, and stress level was evaluated using finite element analysis. By loading the tipping force and torsion moment, which are similar to those applied by the stainless steel rectangular wire ($0.019{\times}0.025$ -in), stress distributions were calculated, and von Mises stress values were obtained. Results: In pSRB and fSRB, the stress value of the torque moment was much higher than that of the tipping force. The pSRB showed higher stress value than fSRB in both tipping force and torque moment because of the difference in size and configuration of the metal frame inserted into the slot. More stress was also found to be concentrated on the slot area than the wing area in fSRB. Conclusion: The slot form of fSRB was found to be more resistant to the stress of tipping and torque than the slot form of pSRB. In addition, the slot areas -- rather than the wing areas -- of the bracket showed breakage susceptibility. Therefore, resistance to the torque moment on the slot area should be considered in bracket design.

Discoloration of various CAD/CAM blocks after immersion in coffee

  • Lauvahutanon, Sasipin;Shiozawa, Maho;Takahashi, Hidekazu;Iwasaki, Naohiko;Oki, Meiko;Finger, Werner J.;Arksornnukit, Mansuang
    • Restorative Dentistry and Endodontics
    • /
    • 제42권1호
    • /
    • pp.9-18
    • /
    • 2017
  • Objectives: This study evaluated color differences (${\Delta}Es$) and translucency parameter changes (${\Delta}TPs$) of various computer-aided design/computer-aided manufacturing (CAD/CAM) blocks after immersion in coffee. Materials and Methods: Eight CAD/CAM blocks and four restorative composite resins were evaluated. The CIE $L^{\ast}a^{\ast}b^{\ast}$ values of 2.0 mm thick disk-shaped specimens were measured using the spectrophotometer on white and black backgrounds (n = 6). The ${\Delta}Es$ and ${\Delta}TPs$ of one day, one week, and one month immersion in coffee or water were calculated. The values of each material were analyzed by two-way ANOVA and Tukey's multiple comparisons (${\alpha}=0.05$). The ${\Delta}Es$ after prophylaxis paste polishing of 1 month coffee immersion specimens, water sorption and solubility were also evaluated. Results: After one month in coffee, ${\Delta}Es$ of CAD/CAM composite resin blocks and restorative composites ranged from 1.6 to 3.7 and from 2.1 to 7.9, respectively, and ${\Delta}TPs$ decreased. The ANOVA of ${\Delta}Es$ and ${\Delta}TPs$ revealed significant differences in two main factors, immersion periods and media, and their interaction except for ${\Delta}Es$ of TEL (Telio CAD, Ivoclar Vivadent). The ${\Delta}Es$ significantly decreased after prophylaxis polishing except GRA (Gradia Block, GC). There was no significant correlation between ${\Delta}Es$ and water sorption or solubility in water. Conclusions: The ${\Delta}Es$ of CAD/CAM blocks after immersion in coffee varied among products and were comparable to those of restorative composite resins. The discoloration of CAD/CAM composite resin blocks could be effectively removed with prophylaxis paste polishing, while that of some restorative composites could not be removed.

이원중합형 코어 축조용 복합레진의 결합강도에 대한 NaOCI의 영향에 대한 연구 (Influence of Sodium Hypochlorite on Bond Strength of Dual-cured Core Build-up Resin Composite)

  • 이준봉;박종덕;권수미;유미경;이광원
    • 구강회복응용과학지
    • /
    • 제23권4호
    • /
    • pp.283-292
    • /
    • 2007
  • Two-step or one-step bonding systems generally inhibit curing process of dual-cured core build-up resin composite for their adhesive acidity. In addition this dual-cured core build-up resin composite can be applied to dentin of pulp chamber and root at the time that complete the endodontic treatment. The purpose of this investigation was to determine the influence of sodium hypochlorite on rnicrotensile bond strength of dual-cured core build-up resin composite. Extracted human molars were horizontally sectioned with 1mm thickness using low speed diamond saw. After the sectioned specimens were divided into 8 groups, adhesive systems (Clearfil SE-Bond, Prime&Bond NT[2-step, 1-step], Adper Prompt L-Pop) were then applied with or without sodium hypochlorite pretreatment. The treated specimen was filled with dual-cured core build-up resin composite (Luxacore, DMG corp., German). Then light cured for 40 seconds and soaked in $37^{\circ}C$ water bath for 24 hours. After the treated specimen was grinded with 1mm width and measured rnicrotensile bond strength by testing machine. Additionally 8 teeth were prepared for SEM evaluation. The results were as follows. : NaOCl treated groups generally had lower rnicrotensile bond strength but did not show any difference statistically except Adper Prompt L-Pop. When the teeth were treated by NaOCl, though the difference of applied adhesive system, it had no statistically significant difference within the NaOCl treated groups except the relation of between ClearFil SE-Bond adhesive system and Adper Prompt L-Pop adhesive system. In the SEM evaluation, NaOCl treated groups presented relatively long resin tags and incomplete hybrid layer formation generally.

섬유의 종류와 조합이 열중합 의치상 레진의 강화에 미치는 영향 (Effect of Fiber Type and Combination on the Reinforcement of Heat Polymerized Denture Base Resin)

  • 유상희;김영임
    • 치위생과학회지
    • /
    • 제10권6호
    • /
    • pp.445-450
    • /
    • 2010
  • 본 연구에서는 열중합 의치상 레진에 유리 섬유, 아라미드 섬유, 폴리에틸렌 섬유를 2.6%, 5.3% 부피비로 첨가하여 섬유의 종류에 따른 강화효과를 평가하고, 각 섬유를 두 가지로 조합한 hybrid FRC를 제작하여 동일 함량의 단독 섬유 FRC보다 굴곡성질이 더 우수한지 평가하고자 하였다. 단독 섬유 FRC에서는 5.3% 부피비의 GL, PE 섬유군의 굴곡강도가 높게 나타났다. 두 가지 섬유 조합FRC의 굴곡강도는 단독 섬유 FRC보다 증가하는 양상을 보였으나, 5.3% GL, PE 섬유군과 유의한 차이가 없었다. 단독 섬유 FRC의 굴곡계수는 5.3% 부피비의 GL 섬유군이 가장 높게 나타났다. 두 가지 섬유 조합FRC의 굴곡계수는 단독 섬유 FRC의 5.3% GL 섬유군보다 높게 나타나 유의한 차이를 보였다. 열중합 의치상 레진의 강화를 위해 섬유를 단독으로 이용할 경우 5.3% 부피비로 첨가한 유리 섬유가 굴곡강도와 굴곡계수 면에서 효과적으로 적용될 수 있을 것으로 본다. 두 가지 섬유 조합FRC의 경우 굴곡강도 면에서는 강화효과가 크지 않았지만, 굴곡계수 면에서 볼 때 유리섬유를 하방에 아라미드 섬유를 그 상방에 위치 시킨 조합을 의치상의 강화에 효과적으로 적용할 수 있을 것으로 본다.

자가부식형 상아질 접착제와 상아질과의 전단결합강도 비교 (Comparison of the shear bond strength of self-etching dentin bonding agents to dentin)

  • 노수정;김부섭;정인성
    • 대한치과기공학회지
    • /
    • 제29권2호
    • /
    • pp.141-150
    • /
    • 2007
  • The purpose of this study was to ascertain the bonding durability of self-etching dentin bonding agents to dentin by means of shear bonding strength. Several acid-etching dentin bonding system (ESPE Z100) and self-etching dentin bonding systems (DEN-FIL, GRADIA DIRET) were used. The occlusion surface of human molars were ground flat to expose dentin and treated with the etch bonding system according to manufactures instruction and followed by composite resin application. After 24hours of storage at 37$^{\circ}C$, the shear bonding strength of the specimens was measured in a universal testing machine with a 1mm/min crosshead speed. An one-way analysis of variance and the scheffe test were performed to identify significant differences (p<0.05). The bonded interfacial surfaces and treated dentin surfaces were examined using a SEM. Through the analysis of shear bond strength data and micro-structures of dentin-resin interfaces, following results are obtained. In dentin group, the shear bond strength of DEN-FIL showed statistical superiority in comparison to the other groups and followed by ESPE Z100 and GRADIA DIRECT (p<0.05).

  • PDF

광중합형 복합레진과 shade guide의 색차에 관한 연구 (A Spectrophotometric Study on Color Differences between Various Light-Cured Composite Resins and Shade Guides)

  • 임경민;이민호;송광엽
    • 구강회복응용과학지
    • /
    • 제25권1호
    • /
    • pp.13-22
    • /
    • 2009
  • 심미적인 특성을 가진 복합레진은 전치부 수복용 재료로 많이 이용되고 있다. 복합레진 수복 시 만족스러운 결과를 얻기 위해서는 색조의 선택이 중요한 역할을 한다. 현재 대부분의 수복용 복합레진은 Vita Lumin 색조견본(shade guide)이나 각각의 회사에서 제공하는 색조견본을 사용하고 있으나, 색조 견본 사이의 색차와 수복물과 견본 사이에 색차가 예상되어 그 차이를 규명하여 임상적인 선택 시에 도움이 되고자 하였다. 4종의 광중합 복합레진(Gradia Direct (GD), Z250 (Z250), Clearfil AP-X (AP-X), $Esthet{\cdot}X$ ($E{\cdot}X$))과 A2와 A3의 색조 견본을 사용하였다. 각 재료마다 3개의 시편과 1개의 색조 견본을 제작하였다. Teflon 주형(깊이 1.35 mm, 직경 8 mm)에 각각의 복합레진을 채우고 응축한 후에 중합하여 젖은 사포로 연마하였다. 색조 견본을 연마용 stone과 고무를 이용하여 1.35 mm 두께로 연마하였다. 컴퓨터에 의해 조절되는 spectrophotometer(color i5, GretagMacbeth, USA)를 이용하여 시편과 색조견본의 색의 특성을 CIELAB coordinates ($L^*$, $a^*$, $b^*$)로 평가하였다. CIELAB 계측을 통하여 복합레진과 색조 견본의 색차(${\Delta}E^*ab$)를 비교 평가 하였다. 광원으로는 CIE standard D65를 사용하였다. 다음과 같은 결과를 얻었다. 1. 동일한 shade로 설계된 여러 제조회사의 복합레진 시편의 $L^*$, $a^*$, $b^*$ 값 간에 유의할 만한 수준의 차이를 나타냈다(p<0.05). 2. 동일한 shade로 설계된 여러 제조회사의 복합레진 시편 간에 대부분 육안으로 인지할 만한 색차(${\Delta}E^*ab>3.3$)값을 나타냈다. 3. 동일한 shade로 설계된 여러 제조회사의 복합레진과 제조회사에서 제공되는 shade guide 및 Vita Lumin shade guide 간에 대부분 육안으로 인지할 만한 색차(${\Delta}E^*ab>3.3$)값을 나타냈다. 4. 임상에서 보다 나은 색 조화를 얻어 심미성을 향상시키기 위해서는 실제 수복물로 제작한 custom shade guide의 제작이 필요할 것으로 생각된다. 제조사에 의해 제공되는 색조 견본이나 Vita Lumin 색조 견본은 임상의에게 복합레진의 색조 선택 시에 정확한 기준을 제공하지는 않았고, 대부분의 제품에서 인지할 수 있는 색차가 있었다. 그러므로 보다 나은 색조 선택을 위해 수복용 레진으로 제작한 맞춤형 색조 견본을 사용하는 것을 추천한다.

치과 캐드캠 시스템에서 사용되는 고분자 수복재료들의 표면특성과 접착양상 (Surface characteristics and bonding performance of polymer restorative materials for dental CAD/CAM systems)

  • 김재홍;김기백
    • 대한치과기공학회지
    • /
    • 제41권3호
    • /
    • pp.203-209
    • /
    • 2019
  • Purpose: The purpose of this study was to investigate the mechanical properties of polymer prosthetic and restorative materials for dental CAD/CAM using two test method; surface characteristics and shear bond strength. Methods: Commercialized CAD/CAM polymer blanks were investigated; One kinds of PMMA, and one PEKK blanks. A total of 20 PMMA and PEKK specimens were prepared, and each group was divided into 10 specimens. Average surface roughness was observed under surface profilometer. The contact angle was measured with a surface electrooptics. The bond strength was evaluated by a universal testing machine at a crosshead speed of 5mm/min. The data were statistically analyzed using independent t-test and Fisher's exact test(P<0.05). Results: The PMMA and PEKK group showed a significant difference in the shear bond strength with the composite resin(P<0.05). The surface roughness of the PEKK group was higher than that of the PMMA group. The fracture mode were observed in PEKK groups with 50% showing adhesive remnant index score. Conclusion: PEEK is used as substructure material and composite veneering material is applied. PEKK resins will contribute to the development of successful products that will provide structural and aesthetic satisfaction.