• Title/Summary/Keyword: dental radiology

Search Result 1,192, Processing Time 0.027 seconds

Pathologic conditions associated with impacted third molars: A retrospective study of panoramic radiographs in a Southern Brazilian population

  • Gabriela Brum Cardoso;Gleica Dal' Ongaro Savegnago;Waneza Dias Borges Hirsch;Mariana Boessio Vizzotto;Gabriela Salatino Liedke
    • Imaging Science in Dentistry
    • /
    • v.53 no.4
    • /
    • pp.303-312
    • /
    • 2023
  • Purpose: This study investigated the prevalence of developmental and acquired pathologic conditions associated with impacted third molars (3Ms) in a Southern Brazilian population and evaluated whether demographic and tooth characteristics were correlated with the presence of bone or tooth lesions. Materials and Methods: Panoramic radiographs were assessed for developmental (bone-related) or acquired (tooth-related) pathoses associated with impacted upper or lower 3Ms. Data on tooth positioning, tooth development, and patient demographics were collected. A trained, calibrated postgraduate student evaluated all images. Binary and multivariate logistic regression models were used to assess associations between outcomes and the demographic and radiographic variables. The threshold for statistical significance was set at 5% (P<0.05). Results: The sample comprised panoramic radiographs from 2054 patients, predominantly female (59.2%), with a mean age of 27.2±11.5 years. Overall, 4066 impacted 3Ms were evaluated, revealing 471 (11.6%) developmental and 710 (17.5%) acquired pathoses. Among the developmental pathoses, 460 (95.2%) were indicative of dentigerous cysts. Male sex, lower 3M location, vertical or distoangular positioning, and incomplete root formation were associated with an elevated likelihood of developmental pathology. Lower tooth position, complete root formation, and partial eruption were linked to an increased probability of an acquired pathology in the third or second molar. Conclusion: The prevalence of pathologic conditions associated with impacted 3Ms was low. Male sex, lower 3M placement, horizontal or distoangular positioning, and incomplete root formation were associated with developmental pathoses, while lower tooth position, complete root formation, and partial eruption were related to acquired pathoses.

THE MEDIAL SIGMOID DEPRESSION: Its Anatomic and Radiographic Considerations (하악골과 방사선사진상에서의 하악절흔 내측 함요)

  • Kang Byung-Cheol
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.21 no.1
    • /
    • pp.7-13
    • /
    • 1991
  • An anatomic radiolucency called medial sigmoid depression can be observed on a number of panoramic and mandibular oblique lateral views in the ramus just below and anterior to the mandibular sigmoid notch. The radiolucency may be unilateral or bilateral. Seventy-eight mandibles of dry skulls were visually examined and radiographed by panoramic machine. The observable incidence, the location center, and the mean size of the medial sigmoid depression were studied. Additionally, the radiographic incidence of the depression was determined using 500 panoramic radiographs. Normal anatomic radiolucent areas in the jaws are encountered often in the radiographs taken for the usual dental practice purpose. Some of these radiolucencies can be misdiagnosed as pathologic entities. But in most cases, the size, location, and appearance of the radiolucent area, and the presence or absence of symptoms can lead one to the correct diagnosis before surgery is undertaken. And this can be secured if diagnosticians are aware of the common and varied appearances of the normal anatomic radiolucencies A depression in the ramus just below and slightly anterior to the most inferior aspect of mandibular sigmoid notch shows occasionally foramen-like or notch-like radiolucency on some panoramic and oblique lateral views. This radiolucency was named medial sigmoid depression by Langlais et a1. in 1983. Since there're no reports about this medial sigmoid depression after that, (The author retrieved the Mediline from 1983 to 1990: Cambridge scientific abstracts, (7200 Wisconsin Ave Bethesda MD 20814 U.S.A.) National Library of Medicine) the author studied the size and the location of the depression of the mandible specimens, and determined the relationship between the observable anatomic incidence and its reproducibility on the radiographs.

  • PDF

Evaluation of the Accuracy of Distance Measurements on 3D Volume-rendered Image of Human Skull Using Multi-detector CT: Effects of Acquisition Section Thickness and Reconstruction Section Thickness

  • Haijo Jung;Kim, Hee-Joung;Lee, Sang-Ho;Kim, Dong-Wook;Soonil Hong;Kim, Dong-Hyeon;Son, Hye-Kyung;Wonsuk Kang;Kim, Kee-Deog
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.457-460
    • /
    • 2002
  • The image quality of three-dimensional (3D) images has been widely investigated by the qualitative analysis method. A need remains for an objective and quantitative method to assess the image quality of 3D volume-rendered images. The purpose of this study was to evaluate the quantitative accuracy of distance measurements on 3D volume-rendered images of a dry human skull by using multi-detector computed tomography (MDCT). A radiologist measured five times the twenty-one direct measurement line items composed among twelve reference points on the skull surface with a digital vernier caliper. The water filled skull specimen was scanned with a MDCT according to the section thicknesses of 1.25, 2.50, 3.75, and 5.00 mm for helical (high quality; pitch 3:1) scan mode. MDCT data were reconstructed with its acquisition section thickness and with 1.25 mm section thickness for all scans. An observer also measured seven times the corresponding items on 3D volume-rendered images with measuring tools provided by volumetric analysis software. The quantitative accuracy of distance measurements on the 3D volume-rendered images was statistically evaluated (p-value < 0.05) by comparatively analyzing these measurements with the direct distance measurements. The accuracy of distance measurements on the 3D volume-rendered MDCT images acquired with 1.25, 2.50, 3,75 and 5.00 mm section thickness and reconstructed with its section thickness were 48%, 33%, 23%, and 14%, respectively. Meanwhile, there were insignificant statistical differences in accuracy of distance measurements among 3D volume-rendered images reconstructed with 1.25 mm section thickness for the each acquisition section thickness. MDCT images acquired with thick section thickness and reconstructed with thin section thickness in helical scan mode should be effectively used in medical planning of 3D volume-rendered images. The quantitative analysis of distance measurement may be a useful tool for evaluating the quantitative accuracy and the defining optimal parameters of 3D volume-rendered CT images.

  • PDF

An Assessment on Cu-Equivalent Image of Digital Intraoral Radiography (디지털구내방사선사진의 구리당량화상에 대한 평가)

  • KIM JAE-DUK
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.33-42
    • /
    • 1999
  • Geometrically standardized dental radiographs were taken. We prepared Digital Cu-Equivalent Image Analyzing System for quantitative assessment of mandible bone. Images of radiographs were digitized by means of Quick scanner and personal Mcquintosh computer. NIH image as software was used for analyzing images. A stepwedge composed of 10 steps of 0.1mm copper foil in thickness was used for reference material. This study evaluated the effects of step numbers of copper wedge adopted for calculating equation. kVp and exposure time on the coefficient of determination(r²)of the equation for conversion to Cu-equivalent image and the coefficient of variation and Cu-Eq value(mm) measured at each copper step and alveolar bone of the mandible. The results were as follows: 1. The coefficients of determination(r²) of 10 conversion equations ranged from 0.9996 to 0.9973(mean=0.9988) under 70kVp and 0.16 sec. exposure. The equation showed the highest r was Y=4.75614612-0.06300524x +0.00032367x² -0.00000060x³. 2. The value of r² became lower when the equation was calculated from the copper stepwedge including 1.0mm step. In case of including 0mm step for calculation. the value of r showed variability. 3. The coefficient of variation showed 0.11, 0.20 respectively at each copper step of 0.2, 0.1mm in thickness. Those of the other steps to 0.9 mm ranged from 0.06 to 0.09 in mean value. 4. The mean Cu-Eq value of alveolar bone was 0.14±0.02mm under optimal exposure. The values were lower than the mean under the exposures over 0.20sec. in 60kVp and over 0.16sec. in 70kVp. 5. Under the exposure condition of 60kVp 0.16sec.. the coefficient of variation showed 0.03. 0.05 respectively at each copper-step of 0.3, 0.2mm in thickness. The value of r² showed over 0.9991 from both 9 and 10 steps of copper. The Cu-Eq value and the coefficient of variation was 0.14±0.01mm and 0.07 at alveolar bone respectively. In summary. A clinical application of this system seemed to be useful for assessment of quantitative assessment of alveolar provided high coefficient of determination is obtained by the modified adoption of copper step numbers and the low coefficient of variation for the range of Cu-Equivalent value of alveolar bone from optimal kVp and exposure time for each x-ray machine.

  • PDF

Comparison of cone beam computed tomography and conventional panoramic radiography in assessing the topographic relationship between the mandibular canal and impacted third molars (하악 제3대구치와 하악관과의 위치관계에 대한 파노라마 방사선사진과 cone beam형 전산화단층촬영상의 비교)

  • Choi, Hyung-Soo;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.38 no.3
    • /
    • pp.169-176
    • /
    • 2008
  • Purpose : To assess the diagnostic accuracy and value in an imaging technique field through the comparison of cone beam computed tomography and conventional panoramic radiography in assessing the topographic relationship between the mandibular canal and impacted third molars. Materials and Methods : Participants consisted of 100 patients offered the images through cone beam computed tomography and panoramic radiography. PSR-$9000^{TM}$ Dental CT system (Asahi Roentgen Ind. Co., Ltd, Japan) was used as the unit of cone beam computed tomography. CE-II (Asahi Roentgen Ind. Co., Ltd, Japan) and Pro Max (Planmeca Oy, Finland) were used as the unit of panoramic radiography. The images obtained through panoramic radiography were classified into 3 types according to the distance between mandibular canal and root of mandibular third molar. And they were classified into 4 types according to the proximity of radiographic feature. The images obtained through cone beam computed tomography based on the classification above were classified into 4 types according to the location between the mandibular canal and the root and were analyzed. And they were classified into buccal, inferior, lingual, and between roots, according to the location between mandibular canal and root. The data were statistically analyzed and estimated by $X^2$-test. Results : 1. There was no statistical significance according to 3 types (type I, type II, type III) through CBCT. 2. The results of 4 types (type A, type B, type C, type D) through CBCT were as high prevalence of CBCT 1 in type A, CBCT 2 in type B, CBCT 3 in type C, and CBCT1 in type D and those of which showed statistical significance (P value=0.03). 3. The results according to location between mandibular canal and root through CBCT recorded each 49, 25, 17, 9 as buccal, inferior, lingual, between roots. Conclusion : When estimating the mandibular canal and the roots through the panoramic radiography, it could be difficult to drive the views of which this estimation was considerable. Thus it is required to have an accurate diagnostic approaching through CBCT that could estimate the location between mandibular canal and roots.

  • PDF

Occupational Radiation Exposure in Korea: 2002 (2002년 국내 방사선 작업종사자의 직업군별 피폭선량)

  • Jeong, Je-Ho;Kwon, Jeong-Wan;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.4
    • /
    • pp.175-183
    • /
    • 2005
  • Dose distribution of Korean radiation workers classified by occupational categories was analyzed. Statistics of the occupational radiation exposure(ORE) in 2002 of the radiation workers in diagnostic and dental radiology were obtained from the Korea Food and Drug Agency(KFDA) who maintains the database for individual radiation dose records. Corresponding statistics for the rest of radiation workers were obtained by processing the individual annual doses provided by the Korea Radioisotope Association(KRIA) after deletion of individual information. The ORE distribution was classified in term of 28 occupational categories, annual individual dose levels, age groups and gender of 52733 radiation workers as of the year of 2002. The total collective dose was 66.4 man-Sv and resulting average individual ORE was 1.26 mSv. Around 80% of the workers were exposed to minimal doses less than 1.2 mSv. However, it appeared that the recorded doses exceeded 20 mSv for 43 workers in the industrial radiography and for 147 workers in the field of radiology. Particularly, recorded doses of 23 workers in radiology exceeded the annual dose limits of 50 mSv, which is extraordinary when the working environment is considered. It is uncertain whether those doses are real or caused by careless placing of dosimeters in the imaging rooms while the X-ray units are in operation. No one in the workforce of 16 operating nuclear power plant units was exposed over 20 mSv in 2002. Number of workers was the largest in their 30's of age and the mean individual dose was the highest in their 20's. Women were around 20% of the radiation workers and their average dose was around one half of that of man workers.

THE ANALYSIS OF THE POSITIONAL RELATIONSHIP OF CONDYLOID PROCESS WITH MANDIBULAR FOSSA AND MORPHOLOGICAL CLASSIFICATION OF CONDYLAR HEAD IN T.M.J. TROUBLE PATIENTS (악관절 기능장애 환자에 있어서 관절돌기의 위치적 관계 및 그 형태에 관한 방사선학적 연구)

  • Park Chang Sik
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.11 no.1
    • /
    • pp.7-22
    • /
    • 1981
  • A morphological and positional classification was undertaken in the transcranial and transorbital views of 174 traceable films which had been selected from those of 274 patients and previous tracing was performed. For the positional analysis, the author adopted the method which is not influenced by TMJ remodelling, and for the morphological classification, made progress the general method by adding indefinite type to four basic types. The aims of this sutudy consists in performing positional and morphological analysis of condylar head and in its morphological and positional variation in symptomatic patients. I want to express my sincere gratitude to Prof. Park, Tae Won in Seoul National University, interesting me in this field researches and for his never failing interests. I would lide to thank Prof. Ahn, Hyung Kyu and Prof. You, Dong Soo for helpful discussion and critical readings. The author is also indebted to Prof. Fuchihate Hajime in Osaka University, Prof. Uemura, Shusaburo and the late Dr. Nishihara, Heihachi for fruitful discussion and encourgements.

  • PDF

A feasibility study on new stimulation method in fMRI language examinations using custom designed images (기능적 자기공명영상의 언어기능검사 시 image를 이용한 자극방법의 타당성 연구)

  • Choi, Kwan-Woo;Son, Soon-Yong;Jeong, Mi-Ae;Min, Jung-Whan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.11
    • /
    • pp.5005-5011
    • /
    • 2011
  • The purpose of this work is to know the validity of a new stimulation method in cognitive functional imaging using custom-designed images correspond to words or syllables improving the shortcomings of existing method using text. From March 2011 to May five Subjects in need of language related functional MRI scanning were selected and both of text stimulating method and image stimulating method sacanning were carried out three times each. Using 3.0T Philps MRI machine and Invivo Co's Eloquence system, data acquisition was performed with EPI-BOLD technique. Post processing was performed with SPM 99 while the activated signals were determined within 95 percent confidence level.The number of activation clusters and the activation ratio inside ROI were compared. As as result, all of the subject showed activation inside Broca area but it did not have statistical significance. In conclusion, the image sitimulation method has potential because image itself is a common means of recognition and it can be recognised easily even if there language barrier. This stimulation method can be applied to replacing the exising scanning method especially in the elderly, infants, foerigners who may not fully understand about the examination.

Assessment of Effective Dose by using additional Filters in Dental Radiography: PC-Based Monte Carlo Program Analysis Subjected on Intraoral Radiography (치과 방사선 촬영의 부가 필터 사용에 따른 유효선량 평가: 구내 촬영에 대한 PC-Based Monte Carlo Program 분석)

  • Kwak, Jong Hyeok;Kim, A Yeon;Kim, Gyeong Rip;Cho, Hee Jung;Moon, Sung Jin;Kil, Sang Hyeong;Lee, Jong Kyu
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.491-498
    • /
    • 2021
  • In this study, the effective dose was measured using the PCXMC v2.0 program by examining the conditions used to set the diagnostic reference level for intraoral imaging recommended by the government, and the effect of the Al additive filter was confirmed. In oral imaging, the largest effective dose was calculated from the oral mucosa among 11 organs. The effect of the Al additive filter showed an excellent radiation reduction effect at 2mm rather than 1mm. In the case of children aged 5 years, the overall effective dose was calculated to be high in all 11 organs because they are more sensitive to radiation than adults. And as a result of evaluating the image quality according to the use of an additional filter during intraoral imaging, there was no significant difference in SNR and CNR changes compared to before the additional filter was used. Based on this study, it is thought that additional filter settings can be recommended for intraoral imaging.

Endodontic management of a C-shaped maxillary first molar with three independent buccal root canals by using cone-beam computed tomography

  • Karanxha, Lorena;Kim, Hee-Jin;Hong, Sung-Ok;Lee, Wan;Kim, Pyung-Sik;Min, Kyung-San
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.3
    • /
    • pp.175-179
    • /
    • 2012
  • The aim of this study was to present a method for endodontic management of a maxillary first molar with unusual C-shaped morphology of the buccal root verified by cone-beam computed tomography (CBCT) images. This rare anatomical variation was confirmed using CBCT, and nonsurgical endodontic treatment was performed by meticulous evaluation of the pulpal floor. Posttreatment image revealed 3 independent canals in the buccal root obturated efficiently to the accepted lengths in all 3 canals. Our study describes a unique C-shaped variation of the root canal system in a maxillary first molar, involving the 3 buccal canals. In addition, our study highlights the usefulness of CBCT imaging for accurate diagnosis and management of this unusual canal morphology.