전국치기공과의 교과과정분석과 전망 (Prospect and Analysis about curriculum of the Department of Dental Laboratory Technology in the whole country)

  • 박용덕;황경숙;김남중
    • 대한치과기공학회지
    • /
    • 제25권1호
    • /
    • pp.203-218
    • /
    • 2003
  • The 3 year graduate school course of the dental technician, which has been enforced since 1994 till the present date, differs from the currently existing 2 year graduate course because of an 8 weeks clinical field training course being newly executed and an imposed curriculum about manufacturing specialized prosthetics like all-ceramic, double prosthetic technology, attachment, and implant. Even though nearly 10 years have passed, the education program of the 18 colleges have still not been standardized and the subjects differing a little, while some are still not following the 3 years graduate course. The goal of this research is to emphasize the qualities of the 3 years graduate program and enable the dental technician to handle clinical models in the dental technical clinic right after graduation by adding clinical field training in the dental technician education program of the 18 colleges. Also in accordance to a national and international increase in esthetical prosthetics, credits, weekly study hours, education practice time of specialized prosthetic dental technology can be analyzed as follows. 1. In the year 2003, currently colleges start clinical practice education starting from the 1st semester of the 2nd year junior year, to the 2nd semester of 3rd year the varying in time with adequate class time, and credits. The average credit is 9.56, and weekly average class time is 18.00 hours. later clinical trainee education will be adjusted to the 3 year graduate school course to 10 credits and 20 hours and the adequate education period should be the 2nd semester of 3rd grade when most basic clinical education has been covered. 2. Currently in the year 2003, all-ceramic education has an average credit of 8.01 in 17 colleges with an exception of Ma-san college. The weekly average theoretical education is 4.94 hours, weekly clinical education of 7.88 hours and currently in 14 colleges porcelain technical class usually starts in the 1st semester of the 2nd year. All-ceramic education is thought to have adequate credits, timing, and weekly study hours. 3. Currently in 2003 implant education is enforced in 11 colleges including Bu-san Catholic university and the education period is usually in the 3rd year. Out of the 11 colleges, only Bu-san Catholic univ., Ma-san and Shinheung college have practice training classes. We knew that Shingu, Dongu, Mokpo science colleges have practice training as a curriculum, namely specific prosthetics laboratory. Out of the 9 colleges enforcing implant education the average credits taken are 2.56, and the average hours of weekly theory education is 2.14, but with the exception of Shinheung college which has an implant practice training course theory and practice classes are not divided. Therefore implant education is thought to start in the 3rd year as a 3 credit course with 3 hours of theory and practice each. 4. Currently in 2003, theoretical attachment education is given in 15 colleges and including practical training it is given in 10 colleges. The education starts 1st semester of the 2nd year till the 2nd semester of the 3rd year. The average credit of attachment theory education in the 15 colleges was 3.64, the average weekly theoretical education was 2.64, and the average weekly practice training out of the schools teaching it was 3.20. Later attachment education is thought to start the 1st semester of the 3rd year as a 3 credit course with 2 hours of theory class and 3 hours of practice training. 5. Double prosthetic technology is currently carried out in Dae-jon Health Science college(2nd year 2nd semester, 2 credits, theory 2hours), Gimcheon college (1 credit, 2 hours of practical training), Bu-san Catholic university (4th year 2nd semester, 4 hours of theory. practice). When the 3 year course is enforced, education will start 1st semester of the 3rd year with 2hours of theory and practice each. 6. The newly installed programs of the 3 year education is clinical field training, and specialized prosthetic manufacturing practice like all-ceramic, double prosthetic technology, attachment, and implant. If such education is to be effectively managed, a primary precursor as systemic basic clinical education is thought to be important. 7. Nationally in the 18 colleges of dental technology the currently executed curriculum course had varying subjects, class time according to the subject, and credits by each college. The curriculum difference between the colleges must be settled.

  • PDF

부산지역(釜山地域) 개업치과(開業齒科)의 치과보철물(齒科補綴物)에 관(關)한 만족도(滿足度) 조사(調査)(I) - 일부정식 치과 보철물에 관하여 - (A Study on Satisfaction of Practicing Dentists about Prosthesis in Pusan Part I : About Fixed Prosthetic appliances)

  • 이명곤
    • 대한치과기공학회지
    • /
    • 제10권1호
    • /
    • pp.159-169
    • /
    • 1988
  • Fixed prosthetic appliance is the restorations of damaged teeth with cast metal or porcelain, and of replacing missing teeth with fixed, or cemented prosthesis. Successfully treating a patient by means of fixed prosthodontics requires the thoughtful combination of dentist and dental laboratory technician. In order to know the satisfaction of dentisits about fixed prosthetic appliances-porcelain, precious and non precious metal-, this study was conducted for 69 practicing dentisis in Pusan during Fed. to Mar. 1988 using a questionnaire method and was analyzed by the use of percentage, $X^2$-test The results are obtained as follow: 1. General characteristics of the respondents, The rate of age distribution of practcing dentists responded was as follow : 31$\sim$35 age group is 29.0%, 51$\sim$55age group 18.8%, 41$\sim$45 age group and 46$\sim$50 group each 11.6%, 36$\sim$40 age group and 56$\sim$60 age group 8.7%, over 60 age group 7.3%, below 30 age group 4.3% respectively. The tate of term of practice experience distribution of dentists responded was as follow : 6$\sim$10 year group 26.1%, 25$\sim$25year group 18.8%, 11$\sim$15 years group and 16~20 years group each 13.0%, below 5 years group and over 30 years group each 10.2%, 26$\sim$30 years group 8.7% in order. The rate of respondents’ degree was follow : bachelor group 81.2%, doctor group 13.0%, master group 5.8% in order. The rate of respondents’completed medical specialist course was as follow : non-complete group 75.4%, complete group 24.6%. The rate of having own laboratory in respondents’clinic was as follow : no having own laboratory group 58.0%, having own labiratory group 42.0% The rate of being lab. technician in respondent;s clinic was as follow: non-being lab. technician group 91.3%, being lab. technician group 8.7%. The rate of transactional commercial dental lab. numbers was as follow : I dental lab. group 40.6%, 2 dental lab. group 30.4%, 3 dental lab. group 20.3%, production at own lab. group 8.7% 2. Cognitions about the respondent's job, About cognition of patient numvers, there were neither many nor few group 62.3%, few group 17.4%, many group 15.9%, too many group 4.4% in order.(P<.01) As compared with the ratio of dentists to patient prothetic treatment, there were moderate level group 46.4%, high level group 33.6%, low level group 18.8% in order.(P<.01) By job satisfaction of respondents, the highest percentage group was satisfied group 44.9%, neither astisfied nor disstified group 33.3%, dissatisfied group 14.5%, much satisfied group 7.3%(P<.01). As compared with the level of prosthetics price, the were moderate level group 71.0%, low level group 23.2%, high level group 5.8%(P<.01) 3. Satisfaction and assessment of dissatisfied factor of the fixed prosthetic appliance, As compared with the satisfaction of al prosthetic appliance, there were neither satisfied nor dissatisfied group 59.4%, satisfied group 20.3% dissatisfied group 18.8%, much satisfied group 1.5% in order.(P<.01). About precious and non precious metal crown and bridge, there were neither satisfied nor dissatisfied group 60.9%, satisfied group 24.6%, dissatisfied group 11.6%, much satisfied group 2.9% in order.(P<.01) The reat of respondent;s satisfaction about porcelain crown and bridge was as follow : neither satisfied nor dissatisfied group 43.5%, dissatisfied group 33.3%, satisfied group 21.7%, much satisfied group 1.5%(P<.01). The rate of respondent's dissatisfied factor item of precious and non precious metal crown and bridge was as follow : inadequate margin fit item 39.1% respondent, inadequate occlusion item 24.6%, inadequate adaptation item 23.2%, poor anat omic form item 15.9%, inadequate contact item 31.9%, improper polishing item 4.4%, the rest item 11.6% respectively. The rate of respondent's dissatisfied factor item of porcelain crown and bridge was as follow : inadequate margin fit item 52.2%, inadequate occlusion item 2.9%, inadequate adaptation item 10.1%, poor anatomic form item 11.6%, improper polishing item 1.5%, shade mismatching item 71%, the rest item 7.2% respectively. The rate of cognition of respondents’ about cause of dissatisfied factor on fixed prosthetic appliance by item was as follow : deficiency of sincerity item 55.1%, deficiency of knowledge about work item 47.8%, deficiency of experience item 15.9%, poor quality of using material item 5.8%, the rest item 2.9% respectively.

  • PDF

Quality of life, patient preferences, and implant survival and success of tapered implant-retained mandibular overdentures as a function of the attachment system

  • Ilze Indriksone;Pauls Vitols;Viktors Avkstols;Linards Grieznis;Kaspars Stamers;Susy Linder;Michel Dard
    • Journal of Periodontal and Implant Science
    • /
    • 제53권3호
    • /
    • pp.194-206
    • /
    • 2023
  • Purpose: A novel attachment system for implant-retained overdentures (IRODs) with novel material combinations for improved mechanical resilience and prosthodontic success (Novaloc) has been recently introduced as an alternative to an existing system (Locator). This study investigated whether differences between the Novaloc and Locator attachment systems translate into differences in implant survival, implant success, and patient-centered outcomes when applied in a real-world in-practice comparative setting in patients restored with mandibular IRODs supported by 2 interforaminal implants (2-IRODs). Methods: This prospective, intra-subject crossover comparison compared 20 patients who received 2 intra-foraminal bone level tapered implants restored with full acrylic overdentures using either the Locator or Novaloc attachment system. After 6 months of function, the attachment in the corresponding dentures was switched, and the definitive attachment system type was delivered based on the patient's preference after 12 months. For the definitive attachment system, implant survival was evaluated after 24 months. The primary outcomes of this study were oral health-related quality of life and patient preferences related to prosthetic and implant survival. Secondary outcomes included implant survival rate and success, prosthetic survival, perceived general health, and patient satisfaction. Results: Patient-centered outcomes and patient preferences between attachment systems were comparable, with relatively high overall patient satisfaction levels for both attachment systems. No difference in the prosthetic survival rate between study groups was detected. The implant survival rate over the follow-up period after 24 months in both groups was 100%. Conclusions: The results of this in-practice comparison indicate that both attachment systems represent comparable candidates for the prosthodontic retention of 2-IRODs. Both systems showed high rates of patient satisfaction and implant survival. The influence of material combinations of the retentive system on treatment outcomes between the tested systems remains inconclusive and requires further investigations.

울산지역 근로자의 보철물과 임플란트의 기대수준에 대한 인식 (Perception on Expectation of Prosthetics and Implant of Workers in Ulsan)

  • 조미숙;김창숙
    • 한국콘텐츠학회논문지
    • /
    • 제14권5호
    • /
    • pp.281-288
    • /
    • 2014
  • 본 연구는 울산시에 소재하는 H기업 예비군 동원훈련에 참여한 307명을 대상으로 보철물(틀니, 브릿지)과 임플란트 기대 수준에 대한 인식을 조사하고, 환자교육 및 상담에 기초자료로 활용하고자 한다. 보철물 기대수준의 신뢰도 cronbach'${\alpha}$는 .971, 임플란트 기대수준의 신뢰도 cronbach'${\alpha}$는 .967로 높게 나타났고 자료의 분석은 IBM SPSS Statistics. v. 19.0 프로그램을 이용하였으며, 유의수준은 0.05로 고려하였다. 연구결과는 첫째, 보철물 기대수준은 평균 3.98점으로 나타났다. 둘째, 임플란트 기대수준은 평균 3.74점으로 나타났다. 셋째, 주관적 건강상태에 따른 임플란트 기대수준은 평균 3.74점으로 나타났고 통계적으로 유의하였다(p=0.003). 넷째, 구강위생관리 관심정도에 따른 임플란트 기대수준의 차이는 평균 3.74점으로 나타났고 통계적으로 유의하였다(0<0.001). 다섯째, 보철물 기대수준과 임플란트 기대수준은 0.392로 강한 양의 상관관계를 나타났다. 위의 결과로 보철과 임플란트에 대한 정확한 정보전달이 필요하다.

Locator attachment를 이용한 하악 임플란트 유지 피개의치의 후향적 평가 (Retrospective Evaluation of Implant Retained Overdentures Using Two Implants and Locator Attachments in the Edentulous Mandibles)

  • 이주형;손동석;이청희
    • 구강회복응용과학지
    • /
    • 제29권2호
    • /
    • pp.153-162
    • /
    • 2013
  • 이번 연구는 2개의 임플란트 식립 후 로케이터를 이용한 하악 임플란트 유지 피개의치를 한 20명의 환자를 대상으로 임플란트 생존율, 변연골 흡수량, 보철적 합병증을 알아보았다. 진료 기록부를 조사하고 방사선 사진을 계측하여 후향적 임상연구를 하였으며, 임플란트는 95%의 누적 생존율을 보였고, 평균 94주 후 방사선 사진에서 임플란트는 평균 1.21 mm($SD{\pm}0.20mm$)의 골소실을 보였다. 보철적 합병증으로는 피개의치 파절, 의치상 이장 또는 개상, 메일의 탈락 또는 유지력 감소로 인한 메일 교체 등이 있었다. 그러나 의치상 이장 및 개상, 메일 인써트의 간단한 교체로 인해 장기적으로 임플란트 및 임플란트 유지 피개의치가 환자에게 유지되고 있었다. Locator를 이용한 하악 임플란트 유지 피개의치는 최소침습적인 수술, 간단한 보철 과정 및 수리 과정의 장점으로 인해 장기적으로 안정적인 치료법으로 사료된다.

The effect of repeated porcelain firings on corrosion resistance of different dental alloys

  • Tuncdemir, Ali Riza;Karahan, Ismail;Polat, Serdar;Malkoc, Meral Arslan;Dalkiz, Mehmet
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권1호
    • /
    • pp.44-50
    • /
    • 2013
  • PURPOSE. The aim of this study was to evaluate the effects of repeated porcelain firing process on the corrosion rates of the dental alloys. MATERIALS AND METHODS. Cr-Co, Cr-Ni and Pd-Ag alloys were used for this study. Each metal supported porcelain consisted of 30 specimens of 10 for 7, 9 and 11 firing each. Disc-shaped specimens 10 mm diameter and 3 mm thickness were formed by melting alloys with a propane-oxygen flame and casted with a centrifuge casting machine and then with the porcelain veneer fired onto the metal alloys. Corrosion tests were performed in quintuplicate for each alloy (after repeated porcelain firing) in Fusayama artificial saliva solution (pH = 5) in a low thermal-expansion borosilicate glass cell. Tamhane and Sheffe test was used to compare corrosion differences in the results after repeated firings and among 7, 9 and 11 firing for each alloy. The probability level for statistical significance was set at ${\alpha}$=0.05. RESULTS. The corrosion resistance was higher (30 mV), in case of 7 times firing (Commercial). On the other hand, it was lower in case of 11 times firing (5 mV) (P<.05). Conclusion. Repeated firings decreased corrosion resistance of Pd-Ag, Cr-Co and Cr-Ni alloys. The Pd-Ag alloy exhibited little corrosion in in vitro tests. The Cr-Ni alloy exhibited higher corrosion resistance than Cr-Co alloys in in vitro tests.

상악 측절치가 유실된 증례의 임상적 고찰과 치험일례

  • 이기수;장열일
    • 대한치과의사협회지
    • /
    • 제18권8호통권137호
    • /
    • pp.639-644
    • /
    • 1980
  • In cases with maxillary lateral incisor missing, the problems were usually treated by the choice between space opening for prosthetic lateral incisor replacement and space closure with cuspid sub stitution for the alteral insicors. The decision of the choice could be perplexing in evaluation of the individual case. Therefore, various diagnostic criteria, such as occlusion, dental esthetics, canine position and inclination, tooth size relationship, maxillary lip length, and skeletal relation had to be evaluated. On the basis of this diagnostic information, the treatment planning could be established. A case was shown to illustrate the treatment of patient with congenitally maxillary lateral incisor missing.

  • PDF

Prosthodontic rehabilitation of a patient with bilateral auricular deformity

  • Mantri, Sneha Shivkumar;Thombre, Ram U.;Pallavi, Daigavane
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권2호
    • /
    • pp.101-105
    • /
    • 2011
  • Maxillofacial prosthodontics is an art and science which provides life like appearance to the person with facial deformity. Maxillofacial prosthetic rehabilitation for acquired defects has become more complex and sophisticated with advancement in techniques and materials. This case report describes the clinical and laboratory procedure for fabricating an auricular prosthesis for a patient with trauma related bilateral auricular deformity. Ear prosthesis was fabricated in two parts taking retention from external auditory canal.

Prosthetic management of a growing patient with Russell-Silver syndrome: a clinical report

  • Kim, Kanghyun;Noh, Kwantae;Paek, Janghyun;Kwon, Kung-Rock;Pae, Ahran
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권5호
    • /
    • pp.406-410
    • /
    • 2015
  • Russell-Silver syndrome (RSS) is a congenital disease characterized by short stature due to growth hormone deficiency, physical asymmetry, inverted triangular face, micrognathia, prominent forehead, and hypodontia. This case report presents a prosthetic management of a 6-year-old patient with Russell-Silver syndrome treated with overdentures on the maxilla and the mandible using the remaining primary teeth. Subsequent and comprehensive dental management considering the growth and development of a young patient will be necessary.

보철치료를 위한 골다공증 환자의 관리 (Management of osteoporosis patients for prosthetic restoration)

  • 백지연;전한솔;이진한
    • 구강회복응용과학지
    • /
    • 제32권2호
    • /
    • pp.93-101
    • /
    • 2016
  • 건강에 대한 관심과 평균 수명 증가로 보철수복을 위해 치과에 내원하는 고령 환자의 수도 증가하고 있다. 고령 환자는 다양한 만성 질환을 가지고 있는 경우가 많다. 특히 골다공증은 고령 환자에서 매년 증가하는 추세로 치과에 내원하는 골다공증 환자 수는 더욱 증가할 전망이다. 현재 비스포스포네이트 제재가 골다공증 치료에 가장 많이 사용되며 장기간 경구복용 하거나 주사제를 투여받은 환자에서 악골괴사가 부작용으로 보고되었다. 이러한 약제관련 악골괴사는 외과적인 치과치료가 원인이 되는 경우가 많고 발병하면 치유가 어려워 예방이 중요하다. 보철 수복을 위한 구강형성 과정에서 외과적 치료가 필요할 수 있으며, 골다공증 환자의 성공적인 치료를 위해 치과의사는 질환에 대해 충분히 이해하고 관심을 가져야 한다.