• Title/Summary/Keyword: dental prosthetic

Search Result 483, Processing Time 0.024 seconds

Prospect and Analysis about curriculum of the Department of Dental Laboratory Technology in the whole country (전국치기공과의 교과과정분석과 전망)

  • Park, Yong-Duck;Hwang, Kyung-Sook;Kim, Nam-Jung
    • Journal of Technologic Dentistry
    • /
    • v.25 no.1
    • /
    • pp.203-218
    • /
    • 2003
  • The 3 year graduate school course of the dental technician, which has been enforced since 1994 till the present date, differs from the currently existing 2 year graduate course because of an 8 weeks clinical field training course being newly executed and an imposed curriculum about manufacturing specialized prosthetics like all-ceramic, double prosthetic technology, attachment, and implant. Even though nearly 10 years have passed, the education program of the 18 colleges have still not been standardized and the subjects differing a little, while some are still not following the 3 years graduate course. The goal of this research is to emphasize the qualities of the 3 years graduate program and enable the dental technician to handle clinical models in the dental technical clinic right after graduation by adding clinical field training in the dental technician education program of the 18 colleges. Also in accordance to a national and international increase in esthetical prosthetics, credits, weekly study hours, education practice time of specialized prosthetic dental technology can be analyzed as follows. 1. In the year 2003, currently colleges start clinical practice education starting from the 1st semester of the 2nd year junior year, to the 2nd semester of 3rd year the varying in time with adequate class time, and credits. The average credit is 9.56, and weekly average class time is 18.00 hours. later clinical trainee education will be adjusted to the 3 year graduate school course to 10 credits and 20 hours and the adequate education period should be the 2nd semester of 3rd grade when most basic clinical education has been covered. 2. Currently in the year 2003, all-ceramic education has an average credit of 8.01 in 17 colleges with an exception of Ma-san college. The weekly average theoretical education is 4.94 hours, weekly clinical education of 7.88 hours and currently in 14 colleges porcelain technical class usually starts in the 1st semester of the 2nd year. All-ceramic education is thought to have adequate credits, timing, and weekly study hours. 3. Currently in 2003 implant education is enforced in 11 colleges including Bu-san Catholic university and the education period is usually in the 3rd year. Out of the 11 colleges, only Bu-san Catholic univ., Ma-san and Shinheung college have practice training classes. We knew that Shingu, Dongu, Mokpo science colleges have practice training as a curriculum, namely specific prosthetics laboratory. Out of the 9 colleges enforcing implant education the average credits taken are 2.56, and the average hours of weekly theory education is 2.14, but with the exception of Shinheung college which has an implant practice training course theory and practice classes are not divided. Therefore implant education is thought to start in the 3rd year as a 3 credit course with 3 hours of theory and practice each. 4. Currently in 2003, theoretical attachment education is given in 15 colleges and including practical training it is given in 10 colleges. The education starts 1st semester of the 2nd year till the 2nd semester of the 3rd year. The average credit of attachment theory education in the 15 colleges was 3.64, the average weekly theoretical education was 2.64, and the average weekly practice training out of the schools teaching it was 3.20. Later attachment education is thought to start the 1st semester of the 3rd year as a 3 credit course with 2 hours of theory class and 3 hours of practice training. 5. Double prosthetic technology is currently carried out in Dae-jon Health Science college(2nd year 2nd semester, 2 credits, theory 2hours), Gimcheon college (1 credit, 2 hours of practical training), Bu-san Catholic university (4th year 2nd semester, 4 hours of theory. practice). When the 3 year course is enforced, education will start 1st semester of the 3rd year with 2hours of theory and practice each. 6. The newly installed programs of the 3 year education is clinical field training, and specialized prosthetic manufacturing practice like all-ceramic, double prosthetic technology, attachment, and implant. If such education is to be effectively managed, a primary precursor as systemic basic clinical education is thought to be important. 7. Nationally in the 18 colleges of dental technology the currently executed curriculum course had varying subjects, class time according to the subject, and credits by each college. The curriculum difference between the colleges must be settled.

  • PDF

A Study on Satisfaction of Practicing Dentists about Prosthesis in Pusan Part I : About Fixed Prosthetic appliances (부산지역(釜山地域) 개업치과(開業齒科)의 치과보철물(齒科補綴物)에 관(關)한 만족도(滿足度) 조사(調査)(I) - 일부정식 치과 보철물에 관하여 -)

  • Lee, Myung-Kon
    • Journal of Technologic Dentistry
    • /
    • v.10 no.1
    • /
    • pp.159-169
    • /
    • 1988
  • Fixed prosthetic appliance is the restorations of damaged teeth with cast metal or porcelain, and of replacing missing teeth with fixed, or cemented prosthesis. Successfully treating a patient by means of fixed prosthodontics requires the thoughtful combination of dentist and dental laboratory technician. In order to know the satisfaction of dentisits about fixed prosthetic appliances-porcelain, precious and non precious metal-, this study was conducted for 69 practicing dentisis in Pusan during Fed. to Mar. 1988 using a questionnaire method and was analyzed by the use of percentage, $X^2$-test The results are obtained as follow: 1. General characteristics of the respondents, The rate of age distribution of practcing dentists responded was as follow : 31$\sim$35 age group is 29.0%, 51$\sim$55age group 18.8%, 41$\sim$45 age group and 46$\sim$50 group each 11.6%, 36$\sim$40 age group and 56$\sim$60 age group 8.7%, over 60 age group 7.3%, below 30 age group 4.3% respectively. The tate of term of practice experience distribution of dentists responded was as follow : 6$\sim$10 year group 26.1%, 25$\sim$25year group 18.8%, 11$\sim$15 years group and 16~20 years group each 13.0%, below 5 years group and over 30 years group each 10.2%, 26$\sim$30 years group 8.7% in order. The rate of respondents’ degree was follow : bachelor group 81.2%, doctor group 13.0%, master group 5.8% in order. The rate of respondents’completed medical specialist course was as follow : non-complete group 75.4%, complete group 24.6%. The rate of having own laboratory in respondents’clinic was as follow : no having own laboratory group 58.0%, having own labiratory group 42.0% The rate of being lab. technician in respondent;s clinic was as follow: non-being lab. technician group 91.3%, being lab. technician group 8.7%. The rate of transactional commercial dental lab. numbers was as follow : I dental lab. group 40.6%, 2 dental lab. group 30.4%, 3 dental lab. group 20.3%, production at own lab. group 8.7% 2. Cognitions about the respondent's job, About cognition of patient numvers, there were neither many nor few group 62.3%, few group 17.4%, many group 15.9%, too many group 4.4% in order.(P<.01) As compared with the ratio of dentists to patient prothetic treatment, there were moderate level group 46.4%, high level group 33.6%, low level group 18.8% in order.(P<.01) By job satisfaction of respondents, the highest percentage group was satisfied group 44.9%, neither astisfied nor disstified group 33.3%, dissatisfied group 14.5%, much satisfied group 7.3%(P<.01). As compared with the level of prosthetics price, the were moderate level group 71.0%, low level group 23.2%, high level group 5.8%(P<.01) 3. Satisfaction and assessment of dissatisfied factor of the fixed prosthetic appliance, As compared with the satisfaction of al prosthetic appliance, there were neither satisfied nor dissatisfied group 59.4%, satisfied group 20.3% dissatisfied group 18.8%, much satisfied group 1.5% in order.(P<.01). About precious and non precious metal crown and bridge, there were neither satisfied nor dissatisfied group 60.9%, satisfied group 24.6%, dissatisfied group 11.6%, much satisfied group 2.9% in order.(P<.01) The reat of respondent;s satisfaction about porcelain crown and bridge was as follow : neither satisfied nor dissatisfied group 43.5%, dissatisfied group 33.3%, satisfied group 21.7%, much satisfied group 1.5%(P<.01). The rate of respondent's dissatisfied factor item of precious and non precious metal crown and bridge was as follow : inadequate margin fit item 39.1% respondent, inadequate occlusion item 24.6%, inadequate adaptation item 23.2%, poor anat omic form item 15.9%, inadequate contact item 31.9%, improper polishing item 4.4%, the rest item 11.6% respectively. The rate of respondent's dissatisfied factor item of porcelain crown and bridge was as follow : inadequate margin fit item 52.2%, inadequate occlusion item 2.9%, inadequate adaptation item 10.1%, poor anatomic form item 11.6%, improper polishing item 1.5%, shade mismatching item 71%, the rest item 7.2% respectively. The rate of cognition of respondents’ about cause of dissatisfied factor on fixed prosthetic appliance by item was as follow : deficiency of sincerity item 55.1%, deficiency of knowledge about work item 47.8%, deficiency of experience item 15.9%, poor quality of using material item 5.8%, the rest item 2.9% respectively.

  • PDF

Quality of life, patient preferences, and implant survival and success of tapered implant-retained mandibular overdentures as a function of the attachment system

  • Ilze Indriksone;Pauls Vitols;Viktors Avkstols;Linards Grieznis;Kaspars Stamers;Susy Linder;Michel Dard
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.3
    • /
    • pp.194-206
    • /
    • 2023
  • Purpose: A novel attachment system for implant-retained overdentures (IRODs) with novel material combinations for improved mechanical resilience and prosthodontic success (Novaloc) has been recently introduced as an alternative to an existing system (Locator). This study investigated whether differences between the Novaloc and Locator attachment systems translate into differences in implant survival, implant success, and patient-centered outcomes when applied in a real-world in-practice comparative setting in patients restored with mandibular IRODs supported by 2 interforaminal implants (2-IRODs). Methods: This prospective, intra-subject crossover comparison compared 20 patients who received 2 intra-foraminal bone level tapered implants restored with full acrylic overdentures using either the Locator or Novaloc attachment system. After 6 months of function, the attachment in the corresponding dentures was switched, and the definitive attachment system type was delivered based on the patient's preference after 12 months. For the definitive attachment system, implant survival was evaluated after 24 months. The primary outcomes of this study were oral health-related quality of life and patient preferences related to prosthetic and implant survival. Secondary outcomes included implant survival rate and success, prosthetic survival, perceived general health, and patient satisfaction. Results: Patient-centered outcomes and patient preferences between attachment systems were comparable, with relatively high overall patient satisfaction levels for both attachment systems. No difference in the prosthetic survival rate between study groups was detected. The implant survival rate over the follow-up period after 24 months in both groups was 100%. Conclusions: The results of this in-practice comparison indicate that both attachment systems represent comparable candidates for the prosthodontic retention of 2-IRODs. Both systems showed high rates of patient satisfaction and implant survival. The influence of material combinations of the retentive system on treatment outcomes between the tested systems remains inconclusive and requires further investigations.

Perception on Expectation of Prosthetics and Implant of Workers in Ulsan (울산지역 근로자의 보철물과 임플란트의 기대수준에 대한 인식)

  • Cho, Mi-Suk;Kim, Chang-Suk
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.5
    • /
    • pp.281-288
    • /
    • 2014
  • This study has surveyed patient education and counseling, based on the data you want to utilize the expectations on dental prosthetic appliances (denture, bridge) and implants among 307 workers who participated in reservists mobilization training of Hyundai Heavy Industries located in Ulsan City. The reliability of expectations on dental prosthetic appliances and implants were fairly high at cronbach'${\alpha}$ of .971 and .967 respectively. The collected data was analyzed through IBM SPSS Statistics. v. 19.0 program at the significance level of 0.05. The research findings are as follows. First, the expectations on prosthetic appliances scored an average of 3.98. Second, the expectations on implants scored an average of 3.74. Third, the expectations on implants depending on subjective health status scored an average of 3.74, which were statistically significant (p=0.003). Fourth, the differences in expectations on implants depending on the concerns for oral hygiene care scored an average of 3.74, which were statistically significant (0<0.001). Fifth, the expectations on prosthetic appliances and implants were strongly correlated at 0.392. As a result of implants of prosthodontics need for accurate information transfer.

Retrospective Evaluation of Implant Retained Overdentures Using Two Implants and Locator Attachments in the Edentulous Mandibles (Locator attachment를 이용한 하악 임플란트 유지 피개의치의 후향적 평가)

  • Lee, Ju-Hyoung;Sohn, Dong-Seok;Lee, Cheong-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.2
    • /
    • pp.153-162
    • /
    • 2013
  • This study compared the marginal bone loss around dental implants that were placed in the canine areas of the mandibles and finded the survival rate of the implants, marginal bone loss around implants and prosthetic complications in 20 patients treated with overdentures retained with Locator attachments. Implants placed in this study showed a 95% survival rate and the average marginal bone loss was 1.21 mm($SD{\pm}0.60mm$) in 94.3 weeks of functional loading. Implant-retained overdentures had various prosthetic complications such as male change, metal cap loosening, Locator attachment loosening, denture teeth change, relining and denture fracture. Implant-retained overdentures using two implants and Locator attachments in the edentulous mandibles is considered as a stable way for long terms because of minimal invasive operation, simple prosthetic process and easy repair.

The effect of repeated porcelain firings on corrosion resistance of different dental alloys

  • Tuncdemir, Ali Riza;Karahan, Ismail;Polat, Serdar;Malkoc, Meral Arslan;Dalkiz, Mehmet
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.1
    • /
    • pp.44-50
    • /
    • 2013
  • PURPOSE. The aim of this study was to evaluate the effects of repeated porcelain firing process on the corrosion rates of the dental alloys. MATERIALS AND METHODS. Cr-Co, Cr-Ni and Pd-Ag alloys were used for this study. Each metal supported porcelain consisted of 30 specimens of 10 for 7, 9 and 11 firing each. Disc-shaped specimens 10 mm diameter and 3 mm thickness were formed by melting alloys with a propane-oxygen flame and casted with a centrifuge casting machine and then with the porcelain veneer fired onto the metal alloys. Corrosion tests were performed in quintuplicate for each alloy (after repeated porcelain firing) in Fusayama artificial saliva solution (pH = 5) in a low thermal-expansion borosilicate glass cell. Tamhane and Sheffe test was used to compare corrosion differences in the results after repeated firings and among 7, 9 and 11 firing for each alloy. The probability level for statistical significance was set at ${\alpha}$=0.05. RESULTS. The corrosion resistance was higher (30 mV), in case of 7 times firing (Commercial). On the other hand, it was lower in case of 11 times firing (5 mV) (P<.05). Conclusion. Repeated firings decreased corrosion resistance of Pd-Ag, Cr-Co and Cr-Ni alloys. The Pd-Ag alloy exhibited little corrosion in in vitro tests. The Cr-Ni alloy exhibited higher corrosion resistance than Cr-Co alloys in in vitro tests.

상악 측절치가 유실된 증례의 임상적 고찰과 치험일례

  • Lee, Gi-Soo;Yong, Yeol-Il
    • The Journal of the Korean dental association
    • /
    • v.18 no.8 s.137
    • /
    • pp.639-644
    • /
    • 1980
  • In cases with maxillary lateral incisor missing, the problems were usually treated by the choice between space opening for prosthetic lateral incisor replacement and space closure with cuspid sub stitution for the alteral insicors. The decision of the choice could be perplexing in evaluation of the individual case. Therefore, various diagnostic criteria, such as occlusion, dental esthetics, canine position and inclination, tooth size relationship, maxillary lip length, and skeletal relation had to be evaluated. On the basis of this diagnostic information, the treatment planning could be established. A case was shown to illustrate the treatment of patient with congenitally maxillary lateral incisor missing.

  • PDF

Prosthodontic rehabilitation of a patient with bilateral auricular deformity

  • Mantri, Sneha Shivkumar;Thombre, Ram U.;Pallavi, Daigavane
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.2
    • /
    • pp.101-105
    • /
    • 2011
  • Maxillofacial prosthodontics is an art and science which provides life like appearance to the person with facial deformity. Maxillofacial prosthetic rehabilitation for acquired defects has become more complex and sophisticated with advancement in techniques and materials. This case report describes the clinical and laboratory procedure for fabricating an auricular prosthesis for a patient with trauma related bilateral auricular deformity. Ear prosthesis was fabricated in two parts taking retention from external auditory canal.

Prosthetic management of a growing patient with Russell-Silver syndrome: a clinical report

  • Kim, Kanghyun;Noh, Kwantae;Paek, Janghyun;Kwon, Kung-Rock;Pae, Ahran
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.5
    • /
    • pp.406-410
    • /
    • 2015
  • Russell-Silver syndrome (RSS) is a congenital disease characterized by short stature due to growth hormone deficiency, physical asymmetry, inverted triangular face, micrognathia, prominent forehead, and hypodontia. This case report presents a prosthetic management of a 6-year-old patient with Russell-Silver syndrome treated with overdentures on the maxilla and the mandible using the remaining primary teeth. Subsequent and comprehensive dental management considering the growth and development of a young patient will be necessary.

Management of osteoporosis patients for prosthetic restoration (보철치료를 위한 골다공증 환자의 관리)

  • Baek, Ji-Yeon;Jeon, Han-Sol;Lee, Jin-Han
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.2
    • /
    • pp.93-101
    • /
    • 2016
  • The average life expectancy has been increased, so the proportion of elderly patients that visit to the dental clinic for prosthetic restoration has increased. Elderly patients have various chronic diseases. Recent trends show an increase of osteoporosis in elderly patients, and thus, the number of osteoporosis patients is expected to escalate. Currently, the most widely used drug for osteoporosis is bisphosphonate. However, osteonecrosis of the jaw has been reported as a side effect derived from longterm oral administration or injection treatment of the drug. Surgical dental treatment was the main cause of medication related osteonecrosis of the jaw (MRONJ). As MRONJ is very difficult to cure, it is important to take preventive measures. Surgical operation may be needed for the mouth preparation before prosthetic restoration. For successful treatment, the dentist should have a full understanding of osteoporosis and show a continued interest toward this disease for careful management.