• 제목/요약/키워드: dental materials

검색결과 3,544건 처리시간 0.026초

Flowable 및 microfill 복합레진으로 충전된 제 5급와동에서 load cycling 전,후의 미세변연누출 비교 (MICROLEAKAGE OF MICROFILL AND FLOWABLE COMPOSITE RESINS IN CLASS V CAVITY AFTER LOAD CYCLING)

  • 강석호;김오영;오명환;조병훈;엄정문;권혁춘;손호현
    • Restorative Dentistry and Endodontics
    • /
    • 제27권2호
    • /
    • pp.142-149
    • /
    • 2002
  • Low-viscosity composite resins may produce better sealed margins than stiffer compositions (KempScholte and Davidson, 1988: Crim, 1989). Plowable composites have been recommended for use in Class V cavities but it is also controversial because of its high rates of shrinkage. On the other hand, in the study comparing elastic moduli and leakage, the microfill had the least leakage (Rundle et at. 1997) Furthermore, in the 1996 survey of the Reality Editorial Team, microfills were the clear choice for abfraction lesions. The purpose of this study was to evaluate the microleakage of 6 compostite resins (2 hybrids, 2 microfills, and 2 flowable composites) with and without load cycling. Notch-shaped Class V cavities were prepared on buccal surface of 180 extracted human upper premolars on cementum margin. The teeth were randomly divided into non-load cycling group (group 1) and load cycling group (group 2) of 90 teeth each. The experimental teeth of each group were randomly divided into 6 subgroups of 15 samples. All preparations were etched, and Single bond was applied. Preparations were restored with the following materials (n=15) : hybrid composite resin [Z250(3M Dental Products Inc. St. Paul, USA), Denfil(Vericom, Ahnyang, Korea)], microfill [Heliomolar RO(Vivadent, Schaan, Liechtenstein), Micronew(Bisco Inc. Schaumburg, IL, USA)], and flowable composite[AeliteFlo(Bisco Inc. Schaumburg, IL, USA), Revolution(Kerr Corp. Orange, CA, USA)]. Teeth of group 2 were subjected to occlusal load (100N for 50,000 cycles) using chewing simulator(MTS 858 Mini Bionix II system, MTS Systems Corp. Minn. USA). All samples were coated with nail polish 1mm short of the restoration, placed in 2% methylene blue for 24 hours, and sectioned with a diamond wheel. Enamel and dentin/cementum margins were analyzed for microleakage on a sclale of 0 (no leakage) to 3 (3/3 of wall). Results were statistically analyzed by Kruscal-Wallis One way analysis, Mann-Whitney U-test, and Student-Newmann-Keuls method. (p = 0.05) Results : 1. There was significantly less microleage in enamel margins than dentinal margins of all groups (p<0.05) 2. There was no significant between six composite resin in enamel margin of group 1. 3. In dentin margin of group 1, flowable composite had more microleakage than others but not of significant differences. 4. there was no significant difference between six composite resin in enamel margin of group 2. 5. In dentin margin of group 2, the microleakage were R>A =H=M>D>Z. But there was no significant differences. 6. In enamel margins, load cycling did not affect the marginal microleakage in significant degree. 7. In enamel margins, load cycling did affect the marginal microleakage only in Revolution. (p<0.05).

2단계 접착제의 상아질 결합강도에 대한 Er:YAG 레이저 조사 영향 (Effect of Er:YAG lasing on the dentin bonding strength of two-step adhesives)

  • 송병춘;조영곤;이명선
    • Restorative Dentistry and Endodontics
    • /
    • 제36권5호
    • /
    • pp.409-418
    • /
    • 2011
  • 연구목적: 이 연구는 상아질 표면에 Er:YAG 레이저를 조사하지 않는 군, 레이저를 조사한 군, 레이저를 조사한 후 부가적인 산처리를 한 군으로 분류하여 2단계 단일병 전부식 접착시스템과 자가부식 프라이머 접착시스템을 이용하여 복합레진을 접착하였을 때 이러한 표면처리가 복합레진의 미세전단 결합강도와 결합계면에 미치는 영향을 비교하기 위하여 시행하였다. 연구 재료 및 방법: 32개의 발거된 대구치의 교합면측 상아질을 이용하였고, 상아질의 표면처리는 1군과 4군에서 각각 인산과 자가부식 프라이머로 하였으며, 2군과 5군은 Er:YAG 레이저로 에칭처리하였고, 3군과 6군은 레이저로 에칭한 후 다시 각각 인산과 자가부식 프라이머로 하였다. 1군, 2군, 3군은 Single Bond 2와 Z 250 (3M ESPE)을 이용하였고, 4군, 5군, 6군은 Clearfil SE Bond와 Clearfil AP-Z (Kuraray)을 이용하여 상아질 면에 Tygon tube를 접착하였다. 각 군의 미세전단 결합강도를 측정한 후 통계 처리하였고, 또한 6개의 시편에서 복합레진과 상아질 계면을 주사전자현미경하에서 관찰하였다. 결과: Single Bond 2를 사용한 군에서 2군의 결합강도는 1군과 3군보다 통계학적으로 낮게 나타났으며, Clearfil SE Bond를 사용한 군에서 4군, 5군, 6군의 결합강도는 각각 통계학적으로 유의한 차이를 나타내었다(p < 0.05). 2군과 5군은 아주 짧고 가는 레진테그가 관찰되었고, 3군과 6군은 길고 가는 레진테그와 레진테그의 측지가 관찰되었다. 결론: 레이저로 에칭 처리한 상아질에 대한 부가적인 산 처리나 자가부식 프라이머의 처리는 상아질의 접착력을 향상시켰다.

무치악 환자를 위한 참고점들의 효용성에 대한 연구 (A study on the validity of reference points for edentulous patient)

  • 박정재;김명주
    • 대한치과보철학회지
    • /
    • 제53권4호
    • /
    • pp.310-317
    • /
    • 2015
  • 목적: 한국 성인 유치악자를 대상으로 치아와 안모 사이의 크기 및 형태적인 상관관계, 구강 내 해부학적 기준점들과 치아배치 양상 사이의 관계를 조사하여 총의치 제작 시 무치악 환자 치료에 사용되는 기준점들의 효용성을 평가하고자 하였다. 대상 및 방법: 서울대학교 치의학 대학원생을 대상으로 상악 6전치가 정상적으로 배열되어 있는 성인 남성 270명 여성 280명을 선정하여 연구를 수행하였다. 악안면부의 해부학적 구조를 크게 변화시킬 수 있는 외과적 치료를 받은 경우, 교정치료를 받은 경우, 선천적으로 상악 전치부 치아 형태 및 수에 이상이 있는 경우, 상악 전치부 치관의 변형을 초래할 수 있는 수복치료를 받은 경우는 연구대상에서 제외하였다. 연구항목은 안모의 외형, 협골궁 폭경, 안모의 길이, 상악중절치의 형태 및 장경, 상악6전치의 치관 폭경, 견치간 거리, 절치유두 중심에서 중절치 순면까지의 거리, 절치유두 중심에서 양견치 첨단을 지나는 선까지의 수직거리이었다. 이를 바탕으로 안면계측항목과 모형계측항목간의 비율 및 상관관계를 통계적으로 분석하였다. 결과: 본 연구의 한계 내에서 다음과 같은 결과를 얻었다. 1) 안모의 외형과 상악 중절치의 형태가 일치하는 비율은 남성 55.56%, 여성 46.43%, 전체 50.91%이었다. 1) 협골궁 폭경과 상악중절치 폭경, 상악6전치 연합폭경의 비율은 각각 16.8 : 1, 3.0 : 1이며 통계적으로 양의 상관관계가 있었다. 2) 상모학상 안모의 길이(Trichion-Gnathion)와 상악중절치 치관 장경, 코뿌리점-턱끝융기점간 거리(Nasion-Gnathion)와 상악중절치 장경과의 비율은 각각 19.7 : 1, 11.6 : 1이었고 남성에서는 코뿌리점-턱끝융기점간 거리가, 여성에서는 안모의 길이가 더 큰 상관관계가 있었다. 3) 절치유두 중심과 양 견치첨단을 연결하는 선 사이의 수직거리는 $1.33{\pm}1.08mm$이었다. 4) 절치유두 중심에서 중절치 순면까지의 거리는 $9.23{\pm}1.20mm$이었다. 결론: 총의치 제작에 사용되는 기준점들은 한국 성인 유치악자의 경우에도 통계적으로 효용성을 가지며, 중요한 해부학적 지표가 임상적으로 의미를 가진다고 할 수 있다. 그러나 통계적으로 수치에서 차이를 보이고 개별적인 편차를 가지므로 인공치아의 선택이나 배열 후 환자의 동의를 받는 과정이 필수적이라고 할 수 있다.

광중합형 복합레진과 shade guide의 색차에 관한 연구 (A Spectrophotometric Study on Color Differences between Various Light-Cured Composite Resins and Shade Guides)

  • 임경민;이민호;송광엽
    • 구강회복응용과학지
    • /
    • 제25권1호
    • /
    • pp.13-22
    • /
    • 2009
  • 심미적인 특성을 가진 복합레진은 전치부 수복용 재료로 많이 이용되고 있다. 복합레진 수복 시 만족스러운 결과를 얻기 위해서는 색조의 선택이 중요한 역할을 한다. 현재 대부분의 수복용 복합레진은 Vita Lumin 색조견본(shade guide)이나 각각의 회사에서 제공하는 색조견본을 사용하고 있으나, 색조 견본 사이의 색차와 수복물과 견본 사이에 색차가 예상되어 그 차이를 규명하여 임상적인 선택 시에 도움이 되고자 하였다. 4종의 광중합 복합레진(Gradia Direct (GD), Z250 (Z250), Clearfil AP-X (AP-X), $Esthet{\cdot}X$ ($E{\cdot}X$))과 A2와 A3의 색조 견본을 사용하였다. 각 재료마다 3개의 시편과 1개의 색조 견본을 제작하였다. Teflon 주형(깊이 1.35 mm, 직경 8 mm)에 각각의 복합레진을 채우고 응축한 후에 중합하여 젖은 사포로 연마하였다. 색조 견본을 연마용 stone과 고무를 이용하여 1.35 mm 두께로 연마하였다. 컴퓨터에 의해 조절되는 spectrophotometer(color i5, GretagMacbeth, USA)를 이용하여 시편과 색조견본의 색의 특성을 CIELAB coordinates ($L^*$, $a^*$, $b^*$)로 평가하였다. CIELAB 계측을 통하여 복합레진과 색조 견본의 색차(${\Delta}E^*ab$)를 비교 평가 하였다. 광원으로는 CIE standard D65를 사용하였다. 다음과 같은 결과를 얻었다. 1. 동일한 shade로 설계된 여러 제조회사의 복합레진 시편의 $L^*$, $a^*$, $b^*$ 값 간에 유의할 만한 수준의 차이를 나타냈다(p<0.05). 2. 동일한 shade로 설계된 여러 제조회사의 복합레진 시편 간에 대부분 육안으로 인지할 만한 색차(${\Delta}E^*ab>3.3$)값을 나타냈다. 3. 동일한 shade로 설계된 여러 제조회사의 복합레진과 제조회사에서 제공되는 shade guide 및 Vita Lumin shade guide 간에 대부분 육안으로 인지할 만한 색차(${\Delta}E^*ab>3.3$)값을 나타냈다. 4. 임상에서 보다 나은 색 조화를 얻어 심미성을 향상시키기 위해서는 실제 수복물로 제작한 custom shade guide의 제작이 필요할 것으로 생각된다. 제조사에 의해 제공되는 색조 견본이나 Vita Lumin 색조 견본은 임상의에게 복합레진의 색조 선택 시에 정확한 기준을 제공하지는 않았고, 대부분의 제품에서 인지할 수 있는 색차가 있었다. 그러므로 보다 나은 색조 선택을 위해 수복용 레진으로 제작한 맞춤형 색조 견본을 사용하는 것을 추천한다.

두 가지 다른 행정의 니켈 티타늄 파일의 성형 성상: 표면 성상, 상아질 삭편과 도말층에 대한 예비적 비교 연구 (Shaping characteristics of two different motions nickel titanium file: a preliminary comparative study of surface profile and dentin chip)

  • 박소라;박세희;조경모;김진우
    • 구강회복응용과학지
    • /
    • 제30권2호
    • /
    • pp.121-130
    • /
    • 2014
  • 목적: Reciprocating 파일인 WaveOne과 continuous rotary 파일인 ProTaper와 ProFile로 근관 형성시 상아질 벽의 표면성상과 상아질 삭편 크기와 도말층 제거 효과를 비교하였다. 연구 재료 및 방법: 60개 단근치를 ProFile, ProTaper, WaveOne으로 성형 후 근관이 보이도록 grinding 하였다. 근관 성형 동안 상아질 삭편을 모아 건조하였다. Scanning electron microscope으로 상아질 삭편 크기와 근관 표면의 불규칙성과 도말층을 관찰하였다. 결과: 표면 함요부의 범위는 ProFile, ProTaper 그리고 WaveOne에서 $150{\mu}m$, $70{\mu}m$, 그리고 $80{\mu}m$의 범위 내에서 관찰되었다. 상아질 삭편의 크기는 ProFile, ProTaper 그리고 WaveOne에서 $7{\mu}m$, $6.5{\mu}m$, 그리고$4{\mu}m$의 범위 내에서 관찰되었다. 도말층은 WaveOne의 중간 1/3과 근단 1/3에서 유의하게 더 많이 관찰되었다. 결론: WaveOne은 중간 1/3과 치근단 1/3의 도말층 제거 효과를 제외하고, ProFile과 ProTaper와 근관 표면 성상과 상아질 삭편에서 큰 차이가 없는 것으로 사료된다.

Bioactive glass의 장기 임상적 평가 (Clinical Long-term Assessment of Bioactive Glass Graft)

  • 이항빈;백정원;김창성;최성호;조규성;김종관;채중규
    • Journal of Periodontal and Implant Science
    • /
    • 제32권1호
    • /
    • pp.187-198
    • /
    • 2002
  • The ultimate goal of periodontal therapy is the regeneration of periodontal tissue which has been lost due to destructive periodontal disease. To achieve periodontal regeneration, various kinds of methods have been investigated and developed, including guided tissue regeneration and bone graft. Bone graft can be catagorized into autografts, allografts, xenografts, bone substitutes. And materials of all types have different biological activity and the capacity for periodontal regeneration, but ideal graft material has not been developed that fits all the requirement of ideal bone graft material. Recently, bioactive glass that has been utilized in plastic surgery is being investigated for application in dental practice. But, there has not been any long-term assessment of bioactive glass when used in periodontal intrabony defects. The present study evaluates the long-term effects of bioactive glass on the periodontal regeneration in intrabony defects of human and the effect of plaqu control on long term treatment results after dividing patients into those who underwent 3-month regular check-up and those who didn't under go regular check-up The clinical effect on 74sites from 17 infrabony pockets of 11 patients were analyzed 36months after treatment. 51 sites which underwent regular check up were classified as the Follow-up group(F/U group), and 23 sites which did not undergo regular check up were classified as Non Follow-up group(Non F/U group). After comparing the probing depth, attachment loss, bone probing depth before and 36months after treatment, the following results could be concluded. 1. The changes of probing pocket depth showed a statistically significant decrease between after baseline and 36 months after treatment in F/U group(1.79${\pm}$0.68mm) and did no show astatistically significant decrease between after baseline and 36months after treatment in Non F/U group(0.61${\pm}$0.54mm) (P<0.05). 2. The changes of loss of attachment showed a statistically significant decrease between after baseline and 36 months after treatment in F/U group(1.44${\pm}$0.74mm) and did no show astatistically significant decrease between after baseline and 36months after treatment in Non F/U group(1.18${\pm}$1.54) (P<0.05). 3. The changes of bone probing depth showed a statistically significant decrease between after baseline and 36 months after treatment in both F/U(1.35${\pm}$0.28) and Non F/U group(0.78${\pm}$0.55mm) (P<0.05). The results suggest that treatment of infrabony defects with bioactive glass resulted in significan reduction of attachment loss and bone probing depth 36months after the treatment. The use of bioactive glass in infrabony defects, combined with regular check-up and proper plaque control generally shows favorable clinical results. This measn that bioactive glass could be a useful bone substitute.

백서 두개골 결손부에서 항생제를 함유한 키토산 차단막의 골재생 유도 효과 (The Bone regenerative effects of tetracycline blended chitosan membranes on the calvarial critical size defect in Sprague dawley rats)

  • 채경준;김태균;정의원;이수복;정용식;이용근;김창성;채중규;조규성;김종관;최성호
    • Journal of Periodontal and Implant Science
    • /
    • 제35권4호
    • /
    • pp.1019-1037
    • /
    • 2005
  • The major goals of periodontal therapy are the functional regeneration of periodontal supporting structures already destructed by periodontal disease as well as the reduction of signs and symptoms of progressive periodontal disease. There have been many efforts to develop materials and therapeutic methods to promote periodontal wound healing. There have been increasing interest on the chitosan made by chtin. Chitosan is a derivative of chitin made by deacetylation of side chains. Chitosan has been widely studied as bone substitution and membrane material in periodontology. Many experiments using chitosan in various animal models have proven its beneficial effects. Tetracycline has been considered for use in the treatment of chronic periodontal disease and gingivitis. The aim of this study is to evlauate the osteogenesis of tetracycline blended chitosan membranes on the calvarial critical size defect in Sprague Dawley rats. An 8mm surgical defect was produced with a trephine bur in the area of the midsagittal suture. The rats were divided into five groups: Untreated control group versus four experimental group. Four types of membranes were made and comparative study was been done. Two types of non-woven membranes were made by immersing non-woven chitosan into either the tetracycline solution or chitosan-tetracycline solution. Other two types of sponge membranes were fabricated by immersing chitosan sponge into the tetracycline solution, and subsequent freeze-drying. The animals were sacrificed at 2 and 8 weeks after surgical procedure. The specimens were examined by histologic analyses. The results are as follows: 1. Clinically the use of tetracycline blended chitosan membrane showed great healing capacity. 2. The new bone formations of all the experimental group, non-woven and sponge type membranes were greater than those of control group. But, there was no significant difference between the experimental groups. 3. Resorption of chitosan membranes were not shown in any groups at 2 weeks and 8 weeks. These results suggest that the use of tetracycline blended chitosan membrane on the calvarial defects in rats has significant effect on the regeneration of bone tissue in itself. And it implicate that tetracycline blended chitosan membrane might be useful for guided tissue regeneration.

연령에 따른 미소형태분석과 치과지식 정도에 의한 심미성 평가 (A study on the smile according to age and esthetic evaluation by the degree of dental knowledge)

  • 김성진;김문관;박소민;반재삼;박상원
    • 대한치과보철학회지
    • /
    • 제50권4호
    • /
    • pp.249-257
    • /
    • 2012
  • 연구 목적: 본 연구는 광주지역 주민의 나이에 따른 미소형태를 분석하고 설문조사를 통해 심미적인 미소형태를 분석하여 전치부의 보철 수복에 도움을 주고자 하였다. 연구 재료 및 방법: 20대(평균연령 27.2세)와 50, 60대(평균연령 55.6세)의 정상 교합자를 각각 33명(남자 15명, 여자 18명), 20명 (남자 7명, 여자 13명)을 대상으로 하였고, 안정위 시와 미소 시 얼굴정면 사진을 촬영하여 미소 시 입술 형태, 입술의 변화와 치아와의 관계를 계측, 분석하였다. 그 후, 전남대학교 치의학전문대학원 1학년(67명), 4학년(47명)을 대상으로 아름다운 미소에 대한 설문조사를 실시하였다. 결과: 미소 시 상순과 치아와의 관계는 두 그룹 모두 average smile이 가장 많았으며, smile line ratio는 청년층에서 1.09, 장년층에서 0.90으로 나타나 거의 평행한 관계를 보였다. 미소 시 buccal corridor ratio가 커질수록 노출되는 치아 수는 적어지는 역상관관계를 보였다. 미소 시 노출되는 치아는 청년층에서 제2소구치까지 보이는 경우가 63.64%로 제일 많았고, 장년층에서는 제1소구치까지 보이는 경우가 35%로 가장 많았다. 미소 시 상순 하연의 수직적 길이 변화와 상악 중절치 노출 임상치관 길이 사이에는 서로 역상관관계가 보였으며, 하순 상연의 길이 변화와 상악 중절치 노출 임상치관 길이 사이에는 아무런 상관관계가 나타나지 않았다. 결론: 심미성에 관하여는 High smile line과, 미소 시 상악 제1소구치까지 보이는 경우가 제일 심미성이 높았으며, 전남대학교 치의학전문대학원 1학년의 경우, 얼굴전체 사진과 입술만 나타난 사진에서 뽑은 아름다운 미소 사진이 달랐으며, 4학년의 경우에는 일치하였다.

기성품과 맞춤형 임플란트 지대주 나사의 풀림 토크 비교 (Comparison of removal torque between prefabricated and customized abutment screw)

  • ;김지환;김무성;박영범;심준성
    • 대한치과보철학회지
    • /
    • 제50권4호
    • /
    • pp.243-248
    • /
    • 2012
  • 연구 목적: 본 연구의 목적은 임플란트 지대주 연결에 사용되는 기성품 나사와 맞춤형 나사의 풀림 토크를 비교하는 것이다. 연구 재료 및 방법: 세가지 임플란트 시스템에(Osstem, Astra, Zimmer) 대해 고정체와 지대주의 연결에 기성품 나사군(대조군)과 맞춤형 나사군(실험군)으로 총 6군(n = 6)으로 나누었다. 조임 토크조절은 디지털 토크 측정기를 이용하였으며 각 임플란트 제조사가 추천한 조임 토크 값을 적용하였다. 체결 10분 후 동일한 조임 토크를 다시 적용하고 5분 후에 풀림 토크력을 측정하였다. 이 과정을 10회 반복 측정하였다. 반복 하중 실험에서는 6개 군(n = 3)에 대해 체결 10분 후 2차 조임 토크를 적용하고 $30^{\circ}$ 경사로 50 N 하중으로 총 1,000,000번 반복 하중을 가하였다. 반복 하중 적용 이후 풀림 토크값을 측정하였다. 통계 방법으로는 10회 반복 측정에서 풀림 토크값의 차이를 비교하기 위해 repeated measures of ANOVA test (${\alpha}$=.05)를 사용하였고, 반복 하중 후 풀림 토크값의 차이를 비교하기 위해서 각 시스템별 Independant t-test로 통계 처리하였다. 결과: 모든 군에서 반복 횟수가 증가할수록 풀림 토크값이 유의성 있게 감소하는 것으로 나타났다(P<.05). 10회 반복 측정 실험에서는 세 종류의 임플란트에서 대조군(기성품나사)과 실험군(맞춤형 나사) 간에 풀림 토크값은 유의차가 없었다(P>.05). 반복 하중 실험에서 세가지 시스템에서 대조군과 실험군 간의 풀림 토크력은 유의한 차이가 없었다(P>.05). 결론: 반복 측정된 풀림력 검사와 반복 하중을 적용 후 풀림력 검사에서 맞춤형 나사와 기성품 나사의 풀림력은 유의한 차이가 없었다.

두경부암 방사선치료 시 선량 균일도 향상을 위한 Thermoplastic 구강 보상체의 개발 (Development of a Thermoplastic Oral Compensator for Improving Dose Uniformity in Radiation Therapy for Head and Neck Cancer)

  • 최준용;원영진;박지연;김종원;문봉기;윤형근;문수호;전종병;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제23권4호
    • /
    • pp.269-278
    • /
    • 2012
  • 두경부암 방사선치료 시 공동 경계면 및 주변 치료 부위의 선량 균일도 향상을 위하여 조직 등가의 thermoplastic 구강 보상체를 개발하였다. Thermoplastic의 유용성 평가를 위해, 기존에 사용해 오던 치과용 인상재료인 paraffin, alginate, 그리고 putty로 제작한 각 구강 보상체의 물성 및 선량 분포 향상도를 비교하였다. 물성 평가에는 강도 평가(압축 실험, 낙하 실험)와 자연변형도(시간에 따른 체적 변화) 평가를 수행하였으며, 개발한 선량 검증용 팬톰에 삽입한 유리선량계와 Gafchromic EBT2 필름을 이용하여 표면선량, 공동 경계면 선량 및 빔 측면도를 측정하여 전달 선량을 평가하였다. 두 달간 각 구강 보상체의 자연변형도 평가하였을 때, alginate는 수분증발로 최대 80% 체적 변화를 보였으나, thermoplastic을 포함한 나머지 조직 등가 물질은 체적 변화가 3% 미만으로 나타났다. 강도 평가 중 5회 반복한 1.5 m 높이의 자유 낙하실험에서 paraffin은 충격에 의하여 파손이 발생되었으나, thermoplastic은 낙하에 의한 파손이 발생되지 않았으며, 압축 강도 실험에서도 paraffin에 비하여 8배 이상의 높은 힘에서도 파손되지 않았다. 유리선량계를 이용한 선량 검증 결과, 1문 조사 시 조직등가[약 80 HU (Hounsfield Unit)]의 thermoplastic은 동일한 처방 선량 전달 시 약 1,000 HU 이상의 값을 나타내는 putty에 비해 4% 낮은 출력계수(monitor unit) 전달로 약 4.9%의 낮은 표면 선량을 전달하였다. 또한 빔 입사 방향을 기준으로 할 때, 구강 통과 후 경계면의 빔 측면도에서 선량 균일도 평가를 위해 측정한 조사영역 편평도는 air, thermoplastic, putty에서 각각 11.41, 3.98, 4.30으로 나타났다. Thermoplastic 구강 보상체는 조직 등가 물질로 기존에 사용해오던 구강 보상체에 비하여 강도가 높고 물질 변형 확률이 적으며, 구강을 포함을 경계면 및 주변 부위에 균일한 선량 분포를 형성할 수 있으므로 균일한 처방 선량 전달 및 피부 선량 감소가 가능하다.