• Title/Summary/Keyword: dental material

Search Result 1,380, Processing Time 0.028 seconds

A PHOTOELASTIC ANALYSIS OF THE EFFECT OF ORTHOPEDIC FORCES ON THE CRANIOFACIAL COMPLEX UTILIZING THE THREE KINDS OF THE HEAD GEAR (각종의 HEAD GEAR를 사용한 정형력이 두개안면 골에 미치는 영향에 대한 광탄성적 연구)

  • Kim, Kwang-Ho
    • The korean journal of orthodontics
    • /
    • v.16 no.1
    • /
    • pp.71-84
    • /
    • 1986
  • The purpose of this study was to analyze the effect of orthopedic forces on the craniofacial complex utilizing the three kinds of the head gear. (high pull head gear, straight pull head gear, cervical pull head gear) For this study, the teeth and alveolar bone and palate were reproduced from birefringent materials and other parts of craniofacial complex were coated with birefringent material on the model. The effect of orthopedic forces on the craniofacial complex was analyzed by photoelastic method using transmission polariscope and reflection polariscope. The results were as follows. 1. The cervical pull head gear had the greatest tipping effect on the maxillary molars and high pull head gear had the least tipping effect. 2. In areas stressed, the cervical pull head gear stressed the greatest degree. 3. Only cervical pull head gear produced stress at the zygomaticofrontal suture and the posterior region of palate. 4. The straight pull head gear and high pull head gear produced stress at just inferior to the anterior nasal spine. 5. The cervical pull head gear and straight pull head gear produced tensile stress at the fronto-maxillary suture. 6. The pterygoid plates of the sphenoid bone, the zygomatic arches, the junction of the maxilla with the lacrimal and ethmoid bone, and the maxillary molars were affected by three types of head gear.

  • PDF

THE EPIDEMIOLOGIC STUDY ON DENTAL MALOCCLUSION AND SKELETAL FACIAL PATTERN (부정교합과 골격성 안모형태에 관한 역학적 연구)

  • Cho, Kyu-Seok;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.17 no.1
    • /
    • pp.107-117
    • /
    • 1987
  • The study was designed to examinate the discrimination rate of 4 antero-posterior cephalometric measurements from Angle's malocclusion groups. The material was 246 cephalometric radiographs taken from 42 Normal occlusions, 83 Class I malocclusions, 64Class II Division I malocclusions, 57Class III malocclusions. ANB angle, APDI, AB/OP angle, and Wits appraisal as measurements of antero-posterior skeletal relationship were measured on the cephalometric radiographs and statistically analyzed by the Canonical Discriminant Function. The results of this study were as follows: 1. ANB angle, APDI, AB/OP angle, and Wits appraisal were clinically useful measurements for the evaluation of the antero-posterior skeletal relationship. 2. The rates that discriminate actual malocclusion groups were $77.45\%$ in Wits appraisal, $74.02\%$ in AB/OP angle, $71.08\%$ in ANB angle, and $70.59\%$ in APDI. 3. The discrimination rate of actual Class III malocclusion show above $93\%$, but actual Class I and Class II division I malocclusions were relatively low.

  • PDF

A cephalometric comparison of Skeletal Class III malocclusion and Cleft lip and palate patients (골격성 제 III급 부정교합환자와 구순구개열환자의 두부방사선계측치의 비교)

  • Baik Hyoung-Seon;Yu Hyung-Seog;Jeon Jai-min
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.6 no.2
    • /
    • pp.59-67
    • /
    • 2003
  • A cephalometric study was performed to reveal differences between skeletal Class III malocclusion patients and cleft lip and palate patients, The material for this study consisted of 16 males (mean age 19.8, range 17-29) and 9 females(mean age 19.4, range 16-27) with cleft lip and palate, and 222 Skeletal Class III malocclusion patients(males 106, females 116), Cephalometric tracing and measurements were done by one investigator. Results were followed: 1. Cleft lip and palate group had more retrusive maxilla than the skeletal Class III malocclusion group. 2, Cleft lip and palate group had smaller effective maxillary and mandibular length than skeletal Class III malocclusion group, and the difference was more prominent in the mandible than in the maxilla. 3. Dental compensation was not observed in the upper incisors of cleft lip and palate group and in the lower incisors it was smaller than skeletal Class III group. 4, In the Gonial angle and lower anterior facial height values, there was no significant difference between cleft lip and palate and skeletal Class III malocclusion group. These results can be used in orthodontic treatment planning and orthognathic surgery for the cleft lip and palate patients.

  • PDF

THE MANAGEMENT OF A COMPLEX IMPLANT CASE USING CAD-CAM TECHNOLOGY: A CLINICAL REPORT

  • Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.6
    • /
    • pp.634-638
    • /
    • 2008
  • PURPOSE: The application of computer-aided technology to implant dentistry has created new opportunities for treatment planning, surgery and prosthodontic treatment, but the correct selection and combination of available methods may be challenging in times. Hence, the purpose of this case report is to present a combination of several computer-aided tools as approaches to manage complicated implant case. MATERIAL AND METHODS: A 47 year-old female patient with severe dental anxiety, high expectations, financial restrictions and poor compliance presented for a fixed rehabilitation. A CT scan with a radiographic template obtained with software (SimPlant, Materialize, Leuven, Belgium) was used for treatment planning. The surgical plan was created and converted into a stereolithographic model of the maxilla with bone-supported surgical templates (SurgiGuide, Materialise, Leuven, Belgium), that allowed for the precise placement of 7 implants in a severely resorbed edentulous maxilla. After successful osseointegration, an accurate scan model served as the basis for the fabrication of a one-piece milled titanium framework using the Procera (Nobel Biocare, Gothenburg, Sweden) technology. The final rehabilitation of the edentulous maxilla was rendered in the form of a screw-retained maxillary metal-reinforced resin-based complete prosthesis. RESULTS: Despite challenging circumstances, 7 implants could be placed without bone augmentation in a severely resorbed maxilla using the SimPlant software for pre-implant analysis and the SurgiGuide-system as the surgical template. The patient was successfully restored with a fixed full arch restoration, utilizing the Procera system for the fabrication of a milled titanium framework.

Can Cancer Therapy be Achieved by Bridging Apoptosis and Autophagy: a Method Based on microRNA-Dependent Gene Therapy and Phytochemical Targets

  • Vijayarathna, Soundararajan;Gothai, Sivapragasam;Jothy, Subramanion L;Chen, Yeng;Kanwar, Jagat R;Sasidharan, Sreenivasan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.17
    • /
    • pp.7435-7439
    • /
    • 2015
  • A failure of a cell to self destruct has long been associated with cancer progression and development. The fact that tumour cells may not instigate cell arrest or activate cell death mechanisms upon cancer drug delivery is a major concern. Autophagy is a mechanism whereby cell material can be engulfed and digested while apoptosis is a self-killing mechanism, both capable of hindering multiplication after cell injury. In particular situations, autophagy and apoptosis seem to co-exist simultaneously or interdependently with the aid of mutual proteins. This review covers roles of microRNAs and chemopreventive agents and makes an attempt at outlining possible partnerships in maximizing cancer cell death with minimal normal cell damage.

The Influence of Surface Treatment and Opaque Application Methods on the Bond Strength of PFM Restorations (모래분사법과 불투명 도재의 도포방법이 도재용착주조관의 전단결합강도에 미치는 영향)

  • Kim, Sung-Min;Choi, Sung-Min;Chung, In-Sung
    • Journal of Technologic Dentistry
    • /
    • v.33 no.4
    • /
    • pp.339-347
    • /
    • 2011
  • Purpose: This study was investigated the bonding strength of two kinds of Ni-Cr alloy with respect to the condition of surface treatment. Methods: The surface treatment was performed on the two kinds of Ni-Cr alloy (B alloy and R alloy) specimens, which were sandblasted with $50{\mu}m$, $110{\mu}m$, and $250{\mu}m$ aluminium oxide and were treated with opaque application (paste and wash opaque). The roughness on the surfaces of the specimens was observed. The metal-ceramic interfaces were analyzed with EPMA in order to ionic diffusion, and the shear test was performed. Results: The BA250 specimen, which has higher surface roughness, showed the highest bonding strength in B specimens. In R specimens, the bonding strength of RA110 specimen was the highest. Conclusion: B specimen formed a mechanical bond between metal-ceramic interfaces; however, in the case of R specimen, a chemical bond was formed between that interfaces. There was no significant statistical difference between the bonding strengths of two types of specimens (p>0.05).

AN EXPERIMENTAL STUDY OF THE EFFECT OF S. MUTANS ON THE PULP IN RELATION TO THE REMAINING DENTIN THICKNESS (잔존 상아질 후경에 따른 S. mutans의 성견 치수반응에 관한 실험적 연구)

  • Kim, Hyung-Dong
    • Restorative Dentistry and Endodontics
    • /
    • v.15 no.2
    • /
    • pp.34-45
    • /
    • 1990
  • The purpose of this study was to evaluate the pulpal responses of S. mutans (6715, serotype A) in relation to the remaining dentin thickness. The material was consisted of 72 teeth from 6 dogs. Cl. V cavities were prepared into 2 different thickness (0.5mm, 1.0mm) of remaining dentin. In the control groups, the cavities were filled with filter paper of broth, tin foil, and IRM$^{(R)}$ cement. In the experimental groups, the cavities were filled with filter paper of S. mutans, filter paper of broth, tin foil, and IRM$^{(R)}$ cement. The intervals of observation period were 1 week, 3 weeks, and 8 weeks respectively after the experiment. The specimens were fixed with 10% formalin and decalcified in 5% nitric acid. All specimens were stained with Hematoxylin-Eosin and examined histopathologically under the microscope. The results were as follows. 1. The changes and congestion of odontoblastic layers were more frequent and lasting in the control group of 0.5mm than in that of 1.0mm remaining dentin thickness. 2. There was no characteristic difference between the control group of 1.0mm and the experimental group of 1.0mm in all pulp responses. 3. Acute and chronic inflammatory cells were seen in the experimental group of 0.5mm, but not seen in the control group of 0.5mm.

  • PDF

A Study on Corrosion Resistance and Mechanical Properties of Ti-15Sn System Alloys for Medical Implants (생체용 Ti-15Sn계 합금의 내식성 및 기계적 성질에 관한 연구)

  • Lee, Doh-Jae;Kim, Dae-Hwan;Park, Hyo-Byeong;Lee, Kyung-Ku
    • Journal of Korea Foundry Society
    • /
    • v.20 no.3
    • /
    • pp.208-215
    • /
    • 2000
  • The mechanical properties and corrosion resistance of Ti alloys for medical implants have been investigated. Ti, Ti-15Sn-4Nb and Ti-15Sn-4Nb-2Zr alloys were melted in arc furnace and the corrosion resistance of Ti alloys was evaluated by anodic polarization test. The microstructure and mechanical properties of Ti alloys were analysed by optical microscope, hardness and tensile tester. The tensile strength of the pure-Ti improved by addition of Sn and Nb and Ti-15Sn-4Nb alloy showed better Rockwell hardness compared with pure Ti. However, there was no significant difference in corrosion resistance between thoseTi-alloys made of Pure-Ti and Ti-15Sn-4Nb alloy. The passive films on the Ti-15Sn-4Nb alloy in air atmosphere consisted of $TiO_2$, SnO and NbO as demonstrated by X-ray photoelectron spectroscopy(XPS)

  • PDF

A pH Optosensor Based on Fluoresence from Nile Blue Encapsulated within Silica Sol-Gel Film (실리카 졸-겔막을 이용한 pH 광학센서)

  • Lee, Jung-Min;Li, Ming;Lee, Sang-Hak;Kim, Young-Sun;Kim, Chang-Jin;Lee, Boo-Huyng
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.169-174
    • /
    • 2004
  • A fiber optic pH sensor has been fabricated using nile blue entrapped in an ammonia catalyzed silica sol-gel film coated on glass substrate by dip-coating. The sensor was fixed on the end of an optical fiber. The sensor showed pH sensitivity when dipped into liquids at different pHs. Linear and reproducible responses were obtained in standard buffer solutions in the pH range $6.0{\sim}8.5$, which encompasses the clinically-relevant range. The effects of interferences on the determination of pH were also investigated. The sensors were successfully applied to the determination of pH in different commercial ionic drinks.

Survival rate of Astra Tech implants with maxillary sinus lift

  • Yoon, Wook-Jae;Jeong, Kyung-In;You, Jae-Seek;Oh, Ji-Su;Kim, Su-Gwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.40 no.1
    • /
    • pp.17-20
    • /
    • 2014
  • Objectives: The aim of this study was to retrospectively evaluate the clinical survival rate of Astra Tech implants in the maxillary molar region performed with sinus lift and bone graft. Materials and Methods: Ninety-nine Astra Tech implants (Osseospeed) placed in the maxillary molar region using sinus lift from September 2009 to February 2012 were selected with a minimum follow-up period of 1 year. The height of alveolar bone, sinus approach technique, bone material and implant survival rate were evaluated. Results: Of the 99 implants, the survival rate was 90.9%; 8 implants failed within 1 year after implant placement, and 1 implant failed 1 year after implant loading. All failed implants were placed with sinus lift simultaneously. The average height of alveolar bone before implant placement was 6.9 mm, while the height of alveolar bone of failed implants was 2.1 mm, on average. Conclusion: Astra Tech implants placed in the maxillary molar region had generally good survival rates, but the relationship between reduced pre-implant alveolar bone height and implant failure requires further attention.