• Title/Summary/Keyword: dental material

Search Result 1,380, Processing Time 0.03 seconds

AN EXPERIMENTAL STUDY ON THE EFFECT OF Ca(OH)2 UPON THE HEALING PROCESS OF THE PULP AND PERIAPICAL TISSUE IN THE DOGS' TEETH (수산화칼슘이 손상치수조직 및 치근조직의 치유에 미치는 영향에 관한 연구)

  • Lim, S.S.;Yoon, S.H.;Lee, C.S.;Lee, M.J.;Kim, Y.H.;Kwon, H.C.;Um, C.M.
    • Restorative Dentistry and Endodontics
    • /
    • v.8 no.1
    • /
    • pp.123-131
    • /
    • 1982
  • The purpose of this study was to observe the responses of the remaining pulp tissue after pulpotomy upon the several kinds of $Ca(OH)_2$ products and the responses of periapical tissue upon some root canal filling materials after extirpation. For pulpotomy, the class V cavities were prepared on the premolars, molars and upper canines, and the pulp was amputated. Each drug was placed over the amputated tissue and cavity was sealed with zinc oxide eugenol cement. The drugs which were used for the study were Dycal (Caulk Co. U.S.A.), Cavitec (Kerr Co. U.S.A.), Calvital, Nobudyne and Neodyne (Neo Dental Chemical Products). For extirpation, the endodontic cavities were prepared on the lingual surfaces of anterior teeth, and the pulp tissues were extirpated as routine method. After enlarging, irrigation, and measuring of root length by taking X-ray, each root canal filling material was filled in the canal with gutta percha cone, and endodontic cavity was sealed with zinc oxide eugenol cement. Zinc oxide eugenol, $Ca(OH)_2$ (Eli Lilly Co. U.S.A.) and Vitapex (Neo Dental Chemical Products) were used as root canal filling materials. Animals were sacrificed after 1, 3 and 6 weeks following the operation. The teeth were decalcified in formic acid, sectioned and stained with hematoxylin eosin. Microscopic examination revealed as follows. 1. Dycal: The dentin bridge formation was observed at the 3rd week after pulpotomy. Inflammatory conditions which were infiltration of inflammatory cells and dilatation of blood vessels were kept in remaining pulp tissue at the 6th week. 2. Calvital: The dentin bridge was observed at the 1st week after pulpotomy. As the time clasped, the pulp tended to be the fibrous degeneration. 3. Cavitec, Nobudyne and Neodyne: In the case of Cavitec and Nobudyne, the incompleted and irregular dentin bridge was observed at the 6th week, and in Neodyne, was observed at the 3rd week. The severe inflammatory changes were seen in the remaining pulp tissue. As the time clasped, the fibrous degeneration tended to spread in the remaining pulp tissue. 4. $Ca(OH)_2$: Osteocementum was formed at the 3rd week, the matrix of cementum and dentin were resorted, and infiltration of lymphocytes was seen in periapical tissue when $Ca(OH)_2$ was used as canal-filling materials. S. ZOE and Vitapex The cementum like substance was seen in periapical portion at the 1st week, when ZOE and Vitapex were used as root canal filling materials. As the time elapsed, the matrix of cementum and dentin tended to be resorted. At the 6th week, the inflammatory condition of periapical tissue was continued in the case of ZOE, but was reduced in the case of Vitapex.

  • PDF

A MOLECULAR BIOLOGIC STUDY ON BIOCOMPATIBILITY OF METALLIC DENTAL MATERIALS USED FOR CHILDREN WITH CULTURED HUMAN GINGIVAL FIBROBLASTS (인체 섬유모세포(HGF-1) 배양에서 소아용 치과금속재의 세포친화성에 대한 분자생물학적 연구)

  • Kim, Ju-Mi;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.2
    • /
    • pp.243-254
    • /
    • 2002
  • For the purpose of evaluating the biocompatability of 3 kinds of metallic materials frequently used in pediatric dentistry (stainless steel crown, orthodontic band, orthodontic wire), cellular and molecular studies, including cell growth and proliferation, screening of cell death with determination of types whether necrosis or apoptosis and changes in expressions of related signaling molecules were examined, using cultured human gingival fibroblasts (HGF-1), HGF-1 was cultured in Dulbecco's modified Eagle's medium. among which the 3rd to 6th generations of HGF-1 were used. The specimen were divided into stainless steel crown (R), band (B) and wire (W). The immunocytochemical study was done for the detection of anti-PCNA (proliferating cell nuclear antigen) labeling. With extracted protein, western blot was done for the detection of ERK1/2, JNK, and p38, using individual antibodies. Cultured cells proliferated, remarkably till 7 day and slightly at 11 day. There was no statistical significance in the counts of proliferating HGF-1 between control and experimental groups (p>0.05). Relative growth rates were no statistically significant difference between control and experimental groups (p>0.05). PCNA labeling indexes showing similar patterns in control and experimental groups. The expressions of ERK1 and ERK2, p38 were similar in control and experimental groups. The expression of JNK increased at 1st day, slightly decreased at 4th day and markedly increased at 7th and 11 day. Although the patterns of control and experimental groups were similar, the increased expressions of JNK at late period suggest a possible stress due to inhibited cell growth and proliferation, and worse culture condition. Conclusively, the 3 kinds of metal specimens used in this study did not induce cellular and molecular hazards during short term culture of HGF-1. But, for the better clinical stability, the establishment of long period culture and animal experiment was thought necessary.

  • PDF

Comparison of the degree of conversion of light-cured resin cement in regard to porcelain laminate thickness, light source and curing time using FT-IR (도재 라미네이트 두께와 광원 및 광조사 시간에 따른 광중합형 레진 시멘트의 FT-IR을 이용한 중합도 비교)

  • Yuh, Chi-Sung;Kim, Jee-Hwan;Kim, Sun-Jai;Lee, Yong-Keun;Shim, June-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.416-423
    • /
    • 2009
  • Statement of problem: The degree of light attenuation at the time of cementation of the PLV restoration depends on characteristics such as thickness, opacity and shade of the restorations, which interfere with light transmittance and, as a result, may decrease the total energy reaching the luting cement. Purpose: The purpose of this study was to compare the degree of conversion of light-cured resin cements measuring by FT-IR in regard to different thickness, light devices and curing time. Material and methods: In the control group, a clear slide glass (1.0 mm) was positioned between the light cured resin cement and light source. The specimens of ceramics were made with IPS Empress Esthetic. The ceramics were fabricated with varying thicknesses-0.5, 1.0, 1.5 mm with shade ETC1. Rely $X^{TM}$ Veneer with shade A3, light-cured resin cement, was used. Light-activation was conducted through the ceramic using a quartz tungsten halogen curing unit, a light emitting diode curing unit and a plasma arc curing unit. The degree of conversion of the light-cured resin cement was evaluated using FT-IR and OMNIC. One-way ANOVA and Tukey HSD test were used for statistical analysis ($\alpha$< .05). Results: The degree of conversion (DC) of photopolymerization using QTH and LED was higher than results of using PAC in the control group. After polymerization using QTH and LED, the DC results from the different ceramic thickness- 0.5 mm, 1.0 mm, 1.5 mm- did not show a significant difference when compared with those of control group. However, the DC for polymerization using PAC in the 1.5mm ceramic group showed significantly lower DC than those of the control group and 0.5 mm ceramic group (P<.05). At 80s and 160s, the DC of light-cured resin cement beneath 1.0 mm ceramic using LED was significantly higher than at 20s (P<.05). Conclusion: Within the limitation of this study, when adhering PLV to porcelain with a thickness between 0.5-1.5 mm, the use of PAC curing units were not considered however, light cured resin cements were effective when cured for over 40 seconds with QTH or LED curing units. Also, when curing the light cured resin cements with LED, the degree of polymerization was not proportional with the curing time. Curing exceeding a certain curing time, did not significantly affect the degree of polymerization.

The fracture resistance of heat pressed ceramics with wire reinforcement (금속선 강화에 따른 열 가압 도재의 파절저항)

  • Jo, Deuk-Won;Dong, Jin-Keun;Oh, Sang-Chun;Kim, Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.191-198
    • /
    • 2009
  • Statement of problem: Ceramics have been important materials for the restoration of teeth. The demands of patients for tooth-colored restorations and the availability of various dental ceramics has driven the increased use of new types of dental ceramic materials. Improved physical properties of theses materials have expanded its use even in posterior crowns and fixed partial dentures. However, ceramic still has limitation such as low loading capability. This is critical for long-span bridge, because bridge is more subject to tensile force. Purpose: The wire reinforced ceramic was designed to increase the fracture resistance of ceramic restoration. The purpose of this study was to evaluate the fracture resistance of wire reinforced ceramic. Material and methods: Heat pressed ceramic(ingot No.200 : IPS Empress 2, Ivoclar Vivadent, Liechtenstein) and Ni-Cr wire(Alfa Aesar, Johnson Matthey Company, USA) of 0.41 mm diameter were used in this study. Five groups of twelve uniform sized ceramic specimens(width 4 mm, thickness 2 mm, length 15 mm) were fabricated. Each group had different wire arrangement. Wireless ceramic was used as control group. The experimental groups were divided according to wire number and position. One, two and three strands of wires were positioned on the longitudinal axis of specimen. In another experimental group, three strands of wires positioned on the longitudinal axis and five strands of wires positioned on the transverse axis. Three-point bending test was done with universal testing machine(Z020, Zwick, Germany) to compare the flexural modulus, flexural strength, strain at fracture and fracture toughness of each group. Fractured ceramic specimens were cross-sectioned with caborundum disc and grinded with sandpaper to observe interface between ceramic and Ni-Cr wire. The interface between ceramic and Ni-Cr wire was analyzed with scanning electron microscope(JSM-6360, JEOL, Japan) under platinum coating. Results: The results obtained were as follows: 1. The average and standard deviation in flexural modulus, flexural strength and fracture toughness showed no statistical differences between control and experimental groups. However, strain was significantly increased in wire inserted ceramics(P<.001). 2. Control group showed wedge fracture aspects across specimen, while experimental groups showed cracks across specimen. 3. Scanning electron microscopic image of cross-sectioned and longitudinally-sectioned specimens showed no gap at the interface between ceramic and Ni-Cr wire. Conclusion: The results of this study showed that wire inserted ceramics have a high strain characteristic. However, wire inserted ceramics was not enough to use at posterior area of mouth in relation to flexural modulus and flexural strength. Therefore, we need further studies.

Evaluation of clinical status of fixed prosthesis (고정성 보철물의 임상적 상태에 대한 평가)

  • Yun, Mi-Jung;Jeon, Young-Chan;Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.99-107
    • /
    • 2009
  • Statement of problem: Restoring and replacing teeth with fixed prostheses commonly used in dental practice. Because of improper oral hygiene care and inaccurate laboratory procedure, complications of fixed prostheses were found in the mouth of patients. Although many efforts have been continually made to obtain the data of long term prognosis of fixed prostheses, it was difficult to do it. Purpose: The purpose of this study was to evaluate the clinical status of fixed prostheses. Material and methods: In order to assess the clinical status of fixed prostheses, a total of 161 individuals(aged 17-85, 99 women and 62 men with 1596 unit of fixed prostheses, and 1169 abutments) who first visited the Department of Prosthodontics, Pusan National University Hospital, between April to September, in 2007 were examined. Results and conclusion: The results of this study were as follows: 1. Length of service of fixed prostheses was $8.6{\pm}0.6$ years(mean), 10.0 years(median). 2. Location of fixed prostheses was found to have no statistically significant influence on longevity of fixed prostheses(P>.05). But, the success rate was high in posterior region and in mandible where the failure rate was high in combination(P<.05). 3. Longevity of fixed prostheses made of metal was longest(mean: $13.0{\pm}9.3$, median: 14.0), gold, precious ceramic, non-precious ceramic trailing behind(P<.05). 4. Number of units in fixed prostheses was found to have no statistically significant influence on longevity of fixed prostheses(P>.05). But, the success rate was high in Single-unit and the failure rate was high in over 3-unit(P<.05). 5. Condition of opposing dentition was found to have no statistically significant influence on longevity of fixed prostheses(P>.05). But, the success rate was high in natural dentition(P<.05). 6. Defective margin(28.2%), dental caries(23.0%), periodontal disease(19.3%), periapical disease(16.9%) were frequent complications. In 30.1% of the cases, abutment state after removing fixed prostheses was needed to be extracted.

THE EFFECTS OF NANO-SIZED HYDROXYAPATITE ON DEMINERALIZATION RESISTANCE AND BONDING STRENGTH IN LIGHT-CURED GLASS IONOMER DENTAL CEMENT (광중합형 글라스아이오노머 시멘트의 탈회 저항성과 결합 강도에 대한 나노미터 입자의 하이드록시아파타이트의 효과)

  • Kim, Ji-Hee;Lee, Yong-Keun;Kim, Seong-Oh;Song, Je-Seon;Choi, Byung-Jai;Choi, Hyung-Jun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.1
    • /
    • pp.24-34
    • /
    • 2010
  • The aim of this study was to evaluate the effect of incorporated nano HA on the demineralization resistance and bonding strength of LC GIC in comparison with micro HA. Fuji II LC GIC was used as the control group and a base material for experimental groups. Two experimental groups were prepared. One was prepared by adding 15% micro HA to LC GIC by weight ratio (Exp. 1), and the other was prepared by adding 15% nano HA instead (Exp. 2). According to the results, the following conclusions could be obtained. 1. Observing under the CLSM, the control group showed thicker enamel demineralization layer than in the experimental groups, and the Exp. 2 group showed the thinnest demineralization layer. 2. In SEM analysis, there was greater enamel demineralization in the control group. The Exp. 2 group was more resistant to demineralization compared to the Exp. 1 group. 3. The bonding strength was found to be in the increasing order of control, Exp. 1, and Exp. 2 group (p < 0.05). 4. Observing the fractured surfaces under SEM after the bonding strength test was performed, there were bone-like apatite particles formed in HA-added experimental groups, and a greater number of bone-like apatite particles were formed in the Exp. 2 group compared to the Exp. 1 group.

Comparison of the SNR in the MR images on dental implant material (치아 임플란트 재료에 따른 자기공명영상의 SNR 비교)

  • Kim, Dong-Hyun;Ko, Seong-Jin;Ye, Soo-Young
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.16 no.4
    • /
    • pp.149-155
    • /
    • 2015
  • Tooth implant is located in oral cavity and affects neck, skull base, and facail image. These magnetic inhomogeneities are usually frequency encoding direction which cause artifacts due to change of signal strength and geometric distortion. First, to evaluate signal to noise ratio (SNR) of magnetic resonance image caused by tooth implant this study uses meat phantom which is similar to human body and is consisted with fat, muscle, and water to measure signal to noise ratio. Second, signal to noise ratio by using custom-made fixed phantom is measured, and then signal to noise ratio size of different tooth implant types is compared and analyzed. The measured signal to noise ratio values of Brushite, HSA, Metal, and RBM for meat phantom were 2.76, 2.22, 1.88, and 1.57 on T1 SE, 1.88, 1.78, 1.65, and 1.79 on T2 FLAIR, 2.28, 2.25, 2.88, and 2.05 on T2 FSE, and 2.74, 1.94, 1.67, and 1.48 on T2 GRE. The measured signal to noise ratio values of Brushite, HSA, Metal, and RBM for fixed water phantom were 1.2, 1.06, 1.12, and 1.22 on DWI, 1.93, 1.87, 1.93, and 2.06 T1 SE, 1.83, 1.76, 1.82, and 1.92 on T2 FLAIR, 1.85, 1.79, 7.86, and 1.97 on T2 FSE, and 1.97, 1.93, 1.99, and 2.06 on T2 GRE. By considering through the results, patients and dentists need to consider some impacts from testing many aspects although their main purpose of having tooth implants is a dental restoration. Moreover, depending on the tooth implant characteristics of individual patients this study results can be used as baseline data when choosing test protocol.

THE CLINICAL STUDY OF MAXILLARY SINUS SEPTA USED IN PANORAMA, CT (Panorama, CT를 이용한 상악동내 중격의 임상적 연구)

  • Jung, Jin-Won;Song, Kyoung-Ho;Lee, Seul-Ki;Kim, Jwa-Young;Yang, Byoung-Eun;Kim, Sung-Gon;Song, Sang-Hun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.3
    • /
    • pp.319-324
    • /
    • 2008
  • Purpose: The aim of this study was to examine the incidence, location and morphology of antral septa using radiographic exam.(Panorama, CT) in the dentate/non-atrophic and edentulous/atrophic maxillary segments. Material & methods: 232 sinuses were subdivided into two groups(group1 : 175 sinuses were classified as complete & partial dentate maxillary segments, group2 : 57 sinuses were classified as complete edentulous maxillary segments) and were investigated for the incidence, location and morphology of maxillary sinus septa. Results: A total of 80 septa were observed in 232 maxillary sinuses, which corresponded to 30.65% of the sinuses(71 of 232). 67.5% of the total septa was observed in the complete & partial dentate groups, but 32.5% of the total septa was observed in the complete edentulous group. Upon analysis of the anatomical location of the septa, it was seen that 14 septa(17.5%) were located in the P1 area, 15 septa(18.7%) were located in the P2 area, 19 septa(23.8%) were located in the M1 area and 32 septa(40%) were located in the M2 area & dista area of M2. we found 45 septa in the apical lesion of teeth, Group 1. However the remaining 9 septa were found in the edentulous area. Conclusion: CT is a better method than panoramic radiography for detecting the presence of the maxillary sinus septa. Maxillary sinus septa are more commonly detected in complete edentulous maxillary segments than in complete & partial dentate maxillary segments. Also maxillary sinus septa are more commonly detected posteriorly than anteriorly.

Shear bond strength analysis of non beryllium PFM metal with degassing and opaque firing techniques (도재용착용 Non beryllium 합금의 degassing과 opaque의 소성술식에 따른 결합강도 분석)

  • Im, Joong-Jae;Lee, Sang-Houck
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.7
    • /
    • pp.4357-4363
    • /
    • 2015
  • This study is to compare the differences of bonding strength based on the Degassing temperatures and various opaque materials for Ni-Cr alloy specimen which does not contain beryllium(Be). Numerous comparison tests have been performed to measure the bonding strength by experimenting 3-point flexural rigidity tests in order to find out ways of stabilization and enhancement of bonding strength between metal and porcelain. AVOVA, surface component observation experiment by SAM/EDS, and Tukey's HSAD posteriori tests results are as follows: First, The bonding strength in all groups has exceeded the minimum (25MPa) of ISO9693 bonding strength regulation for dental mental-porcelain specimen. Second, The bonding strength of Group V1 was $32.37{\pm}1.91MPa$, $38.25{\pm}1.38MPa$ in Group V2, $46.43{\pm}2.14MPa$ in Group V3 and $47.21{\pm}1.72MPa$ Group V4. The difference has been statistically meaningful. Tukey's HSAD posteriori tests results have shown that the bonding strength in Group V4 was higher than that of Group V1. Third, the bonding strength between metal and porcelain without degassing process was higher than that of with degassing process, and the bonding strength of powder opaque was higher than that of paste opaque. Fourth, Group V4 has ranked the highest on the comparison table of metal and porcelain bonding strength.

Detection of Collagenase in Inflammatory Gingiva using Root planning and Argon Laser (치근면 활택술과 아르곤 레이저 사용에 따른 염증성 치은의 교원질 분해효소 검출 비교)

  • Lee, Chang-Gon;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.3
    • /
    • pp.577-594
    • /
    • 1999
  • The major cause of periodontal disease is microorganism in the dental plaque. Gingival sulcular fluid, which is exudate released from the tissue near crevicular epithelium is related with inflammation. The purpose of this study was to evaluate the argon laser efficiency between the clinical index and onset of collagenase of gingival sulcular fluid. Material divided 16 patients into 4 groups. The first control was without treatmemt. The second was with just treatment of argon laser, The third was treated by scaling and root planning and the fourth was treated with both scailing and root planning and argon laser. The level of periocheck test, the index of bleeding, and the depth of periodontal pocket were evaluated from for 128 teeth of 64 anterior teeth and 64 posterior teeth. The results were as follows ; 1. In the score of periocheck test, root planing group(group 3) was significantly reduced more than the group without treatment(group 1) and the argon laser treatment(group 2) for results of 3 days and 7 days. But root planing plus argon laser treatment(group 4) in the 7days after experiment, was significantly reduced than no treatment(group 1) and root planing treatment(group 3)(P<0.05), in the 3 days after experiment, was significantly reduced than root planing(group3)(P<0.05). The score of periocheck test to the root planning group(group 3) were significantly reduced between days1, day3 and day7(P<0.05). Root planning plus argon laser group(group 4) were significantly reduced to 1 or 7days and 3 or 7days(P<0.05). The argon laser group(group 2) didn't show any changes. 2. In the case of sulcus bleeding index, the root planning group(group 3) and root planning plus argon laser group(group 4) were reduced more than without treatment group(group 1)(P<0.05) and sulcus bleeding index in the root planning group(group 3) were reduced more than the argon laser group(group 2)(P<0.05). 3. There wasn't any changes of pocket depth between the control and the experiment group as with experiment periods also.

  • PDF