• Title/Summary/Keyword: dental material

Search Result 1,380, Processing Time 0.03 seconds

SURFACE MICROGROOVES OF THIRTY MICROMETERS IN WIDTH ON TITANIUM SUBSTRATA ENHANCE PROLIFERATION AND ALTER GENE EXPRESSION OF CULTURED HUMAN GINGIVAL FIBROBLASTS

  • Lee, Suk-Won;Kim, Su-Yeon;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.6
    • /
    • pp.787-794
    • /
    • 2007
  • Statement of problem. Surface microgrooves on Ti substrata have been shown to alter the expression of genes responsible for various biological activities of cultured fibroblasts. However, their effect on enhancing cell proliferation is not yet clear. Purpose. The purpose of this study was to determine the dimension of surface microgrooves on Ti substrata that enhances proliferation and alters gene expression of cultured human gingival fibroblasts. Material and methods. Commercially pure Ti discs with surface microgrooves of monotonous $3.5{\mu}m$ in depth and respective 15 and $30{\mu}m$ in width were fabricated using photolithography and used as the culture substrata in the two experimental groups in this study (TiD15 and TiD30), whereas the smooth Ti was used as the control substrata (smooth Ti group). Human gingival fibroblasts were cultured on the three groups of titanium substrata and the proliferation, DNA synthesis, and gene expression of theses cells were analyzed and compared between all groups using XTT assay, BrdU assay, and reverse transcriptase-polymerase chain reaction (RT-PCR), respectively. Results. From the XTT assay at 48 h incubation, the proliferation of human gingival fibroblasts in TiD30 was significantly enhanced compared to that in smooth Ti and TiD15. The results from the BrdU assay showed that, at 24 h incubation, the DNA synthesis was significantly enhanced in TiD30 compared to that in smooth Ti. In RT-PCR, increase in the expression of PCR transcripts of fibronectin, CDK6, $p21^{cip1}$ genes was noted at 48h incubation. Conclusion. Surface microgrooves $30{\mu}m$ in width and $3.5{\mu}m$ in depth on Ti substrata enhance proliferation and alter gene expression of cultured human gingival fibroblasts.

Study on broken periodontal curets (치주큐렛 파절에 대한 연구)

  • Kwon, Oh-Jang;Lee, Jae-Kwan;Chang, Beom-Seok;Um, Heung-Sik
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.1
    • /
    • pp.23-30
    • /
    • 2008
  • Purpose: The purpose of this study was to investigate the incidence of curet fracture and its contributing factors. Material and Methods: Fifty-eight periodontal curets which were broken during periodontal treatment in Kangnung National University Dental Hospital for 1 year were used as study materials. The blade thickness of new curets and broken ones was measured using a digital micrometer. Types of treatment procedures, clinical experience of operators, point of breakage, and method of removal of broken fragments were recorded for each broken curet. Results: The incidence of curet fracture in root planing (16.4 curets per 1,000 procedures) was higher than those in flap surgery (7.5) or supragingival scaling (2.7). No curet was broken during supportive periodontal treatment. The incidence of fracture did not seem to be related with clinical experience of operators. The most frequent breakage point of the curets were upper 1/3 of blades. Fifty-six of 58 broken fragments were removed by non-surgical methods. Two broken tips which could not removed non-surgically were left in the pockets, and proved to be removed spontaneously 1 week later. Conclusion: Root planing showed higher incidence of curet fracture than any other type of periodontal treatment. Most of the fractured fragments were removed by non-surgical method. Further study is needed to develop methods of removal of the fragments which can not be removed non-surgically.

APPLICATION OF THERMOFORMED APPLIANCES IN PEDIATRIC DENTISTRY (소아치과 임상에서의 Thermoformed Appliance의 적용)

  • Kim, Shin;Jeong, Tae-Sung;Yang, Chul-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.3
    • /
    • pp.539-544
    • /
    • 1998
  • Thermoformed appliance, which has been recently introduced for dental usage, is an appliance made of thermoformed sheets and formed with positive or negative pressure under heat. Thermoplastic material is a kind of plastics and can be repeatedly softened by heat. It is classified into hard elastic foil, hard/soft compound foil and soft elastic foil, including BIOPLAST, BIOCRYL, IMPRELON, etc. It has been developed in 1969 and is available in various thickness, shape and color. There are two types of Vacuum former for thermoplastic materials; the pressure type and suction type. The former is much better than the latter for fabrication of various appliances due to its higher pressure. The authors have applied these appliances to some cases - chin cap, active retainer, individual Fluoride tray, mouth protector, bracket transfer mask, bruxism splint(night guard), Essix appliance - by pressure type Vacuum former($Biostar^{(R)}$). The thermoplastic appliances have numerous advantages such as simple procedure, short working time, clean and transparent product, less objectionable taste. But its outstanding advantage would be its excellent biocompatibility bacause it has no monomer and hence no tissue irritation. Although there is some limitations in its usage, it can be used widely for various purposes especaily for pediatric dentistry.

  • PDF

RESTORATION OF A FRACTURED CENTRAL INCISOR USING TOOTH FRAGMENT : CASE REPORT (상악 영구중절치의 외상환자에서 치아파절편을 이용한 치험례)

  • Choi, Eun-Young;Choi, Nam-Ki;Yang, Kyu-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.4
    • /
    • pp.715-721
    • /
    • 2003
  • Dental injuries with crown fracture occur frequently, especially in young patient Reattachment of the crown fragment has been shown to yield good esthetic results in that original tooth anatomy is restored with a material that abrades at a rate indntical to that of the adjacent tooth substance and at the same time permits continual monitoring of pulpal status through the fragment. Case 1 was complicated crown fracture with pin-point bleed ing, that was treated by direct pulp capping with calcium hydroxide and fragment reattachment. Case 2 was in trusive luxation with complicated crown fracture and was treated by pulp treatment and fragment reattachment. Case 3 was uncomplicated crown fracture, and fracture line involved slightly biologic width and treated by reattachment of the crown fragment.

  • PDF

Effect of Sambucus sieboldiana Extract on the Cell Growth and Extracellular Matrix Formation in Osteoblast Cells

  • Kim, Jeongsun;Cho, Seon-Ho;Park, Jong-Tae;Yu, Sun-Kyoung;Kim, Su-Gwan;Kim, Do Kyung
    • International Journal of Oral Biology
    • /
    • v.39 no.2
    • /
    • pp.121-128
    • /
    • 2014
  • Sambucus sieboldiana (SS) is a member of the family Caprifoliaceae and has been recommended as a functional material because of its several bioactivities. Although numerous literatures are available on the pharmacological and biological activities, the biological activity of SS in bone regeneration process has not yet been well-defined. Therefore, in this study, the effect of SS was investigated in the proliferation and differentiation of MC3T3-E1 osteoblastic cell line. The treatment of SS did not significantly affect the cell proliferation in MC3T3-E1 cells. SS significantly accelerated the mineralization and significantly increased the expression of alkaline phosphatase (ALP) and osteocalcin (OC) mRNAs, compared to the control, in the differentiation of MC3T3-E1 cells. SS significantly accelerated the decrease of osteonectin (ON) mRNA expression as compared with the control in a time-dependent manner in the differentiation of MC3T3-E1 cells. These results suggest that the SS facilitate the osteoblast differentiation and mineralization in MC3T3-E1 osteoblastic cells. Therefore, there may be potential properties for development and clinical application of bone regeneration materials.

Mechanical properties by resin injection method of orthdontic acrylic resin (교정용 레진장치의 레진주입방법에 따른 기계적 특성)

  • Jo, Jeong-Ki
    • Journal of Digital Convergence
    • /
    • v.18 no.4
    • /
    • pp.341-346
    • /
    • 2020
  • Polymethyl methacrylate (PMMA), a self-curing resin mainly used in removable orthodontic appliances, is an acrylic resin mainly used in the field of modern dentistry. As an advantage, it has been used for a long time as a material for orthodontic devices in dentistry due to its color and volume, tissue affinity, and stability. The production of PMMA can be divided into self-polymerization method and thermal polymerization method according to activation method. Self-curing resins have long been used as orthodontic devices. The resin injection method is largely divided into a sprinkle-on method and a mixing method. In this study, we intend to test the mechanical properties according to the resin injection method of the orthodontic device, such as strength, modulus of elasticity, and surface roughness. There was no significant difference in strength as a result of three-point bending strength test on rectangular specimens (1.4 × 3.0 × 19.0 mm) of orthodontic PMMA. There was also no significant difference in hardness. There was no significant difference in surface roughness. It was confirmed that the orthodontic PMMA had no significant difference in mechanical properties according to the resin injection method of the orthodontic device.

Histomorphometry and stability analysis of early loaded implants with two different surface conditions in beagle dogs

  • Kim, Dong-Seok;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.1
    • /
    • pp.10-18
    • /
    • 2009
  • STATEMENT OF PROBLEM. Despite an improved bone reactions of Mg-incorporated implants in the animals, little yet has been carried out by the experimental investigations in functional loading conditions. PURPOSE. This study investigated the clinical and histologic parameters of osseointegrated Mg-incorporated implants in early loading conditions. MATERIAL AND METHODS. A total of 36 solid screw implants(diameter 3.75 mm, length 10 mm) were placed in the mandibles of 6 beagle dogs. Test groups included 18 Mg-incorporated implants. Turned titanium implants served as control. Gold crowns were inserted 4 weeks after implant placement and the dogs were immediately put on a food diet. Implants were observed for 10 weeks after loading. Radiographic assessments and stability tests were performed at the time of fixture installation, $2^{nd}$ stage surgery, 4 weeks after loading, and 10 weeks after loading. Histological observations and morphometrical measurements were also performed. RESULTS. Of 36 implants, 33 displayed no discernible mobility, corresponding to successful clinical function. There was no statistically significant difference between test implants and controls in marginal bone levels(P=.46) and RFA values. The mean BIC % in the Mg-implants was $54.5{\pm}8.4%$. The mean BIC % in the turned implant was $45.3{\pm}12.2%$. These differences between the Mg-implant and control implant were statistically significant(P=.005). CONCLUSIONS. The anodized, Mg-incorporated implant demonstrated significantly more bone-to-implant contact(BIC) in early loading conditions. CLINICAL IMPLICATIONS. The results of this study in beagle dogs suggest the possibility of achieving predictable stability of early loaded free-standing dental implants with Mg-incorporated surface.

Evaluation of TMJ sound on the subject with TMJ disorder by Joint Vibration Analysis

  • Hwang, In-Taek;Jung, Da-Un;Lee, Jae-Hoon;Kang, Dong-Wan
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.1
    • /
    • pp.26-30
    • /
    • 2009
  • STATEMENT OF PROBLEM. Qualitative and semi-quantitative methods have been developed for TMJ sound classification, but the criteria presented are completely inhomogeneous. Thus, to develop more objective criteria for defining TMJ sounds, electroacoustical systems have been developed. We used Joint vibration analysis in the BioPAK system(Bioresearch Inc., Milwaukee, USA) as the electrovibratography. PURPOSE. The aim of this study was to examine the TMJ sounds with repect to frequency spectra patterns and the integral > 300 Hz /< 300 Hz ratios via six-months follow-up. MATERIAL AND METHODS. This study was done before and after the six-months recordings with 20 dental school students showed anterior disk displacement with reduction. Joint vibrations were analyzed using a mathematical technique known as the Fast Fourier Transform. RESULTS. In this study Group I and Group II showed varied integral > 300 /< 300 ratios before and after the six-months recordings. Also, by the comparative study between the integral > 300 /< 300 ratios and the frequency spectrums, it was conceivable that the frequency spectrums showed similar patterns at the same location that the joint sound occurred before and after the six-months recordings. while the frequency spectrums showed varied patterns at the different locations that the joint sound occurred before and after six-month recordings, it would possibly be due to the differences in the degree of internal derangement and/or in the shape of the disc. CONCLUSIONS. It is suggested that clinicians consider the integral > 300 /< 300 ratios as well as the frequency spectrums to decide the starting-point of the treatment for TMJ sounds.

Comparion of stability in titanium implants with different surface topographies in dogs

  • Kim, Nam-Sook;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Park, Ha-Ok;Lim, Hyun-Pil
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.1
    • /
    • pp.47-55
    • /
    • 2009
  • STATEMENT OF PROBLEM. A few of studies which compared and continuously measured the stability of various surface treated implants in the same individual had been performed. PURPOSE. We aim to find the clinical significance of surface treatments by observing the differences in the stabilization stages of implant stability. MATERIAL AND METHODS. Eight different surface topographies of dental implants were especially designed for the present study. Machined surface implants were used as a control group. 4 nano-treated surface implants(20 nm $TiO_2$ coating surface, heat-treated 80 nm $TiO_2$ coating surface, CaP coating surface, heat treated CaP coating surface) and 3 micro-treated surface implants [resorbable blast media(RBM) surface, sandblast and acid-etched(SAE) surface, anodized RBM surface] were used as experiment groups. All 24 implants were placed in 3 adult dogs. $Periotest^{(R)}$ & ISQ values measured for 8 weeks and all animals were sacrificed at 8 weeks after surgery. Then the histological analyses were done. RESULTS. In PTV, all implants were stabilized except 1 failed implants. In ISQ values, The lowest stability was observed at different times for each individual. The ISQ values were showed increased tendency after 5 weeks in every groups. After 4 to 5 weeks, the values were stabilized. There was no statistical correlation between the ISQ values and PTV. In the histological findings, the bone formation was observed to be adequate in general and no differences among the 8 surface treated implants. CONCLUSIONS. In this study, the difference in the stability of the implants was determined not by the differences in the surface treatment but by the individual specificity.

Effect of different veneering techniques on the fracture strength of metal and zirconia frameworks

  • Turk, Ayse Gozde;Ulusoy, Mubin;Yuce, Mert;Akin, Hakan
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.6
    • /
    • pp.454-459
    • /
    • 2015
  • PURPOSE. To determine whether the fracture strengths and failure types differed between metal and zirconia frameworks veneered with pressable or layering ceramics. MATERIALS AND METHODS. A phantom molar tooth was prepared and duplicated in 40 cobalt-chromium abutments. Twenty metal (IPS d.SIGN 15, Ivoclar, Vivadent, Schaan, Liechtenstein) and 20 zirconia (IPS e.max ZirCAD, Ivoclar) frameworks were fabricated on the abutments. Each framework group was randomly divided into 2 subgroups according to the veneering material: pressable and layering ceramics (n=10). Forty molar crowns were fabricated, cemented onto the corresponding abutments and then thermocycled ($5-55^{\circ}C$, 10,000 cycles). A load was applied in a universal testing machine until a fracture occurred on the crowns. In addition, failure types were examined using a stereomicroscope. Fracture load data were analyzed using one-way ANOVA and Tukey HSD post-hoc tests at a significance level of 0.05. RESULTS. The highest strength value was seen in metal-pressable (MP) group, whereas zirconia-pressable (ZP) group exhibited the lowest one. Moreover, group MP showed significantly higher fracture loads than group ZP (P=.015) and zirconia-layering (ZL) (P=.038) group. No significant difference in fracture strength was detected between groups MP and ML, and groups ZP and ZL (P>.05). Predominant fracture types were cohesive for metal groups and adhesive for zirconia groups. CONCLUSION. Fracture strength of a restoration with a metal or a zirconia framework was independent of the veneering techniques. However, the pressing technique over metal frameworks resisted significantly higher fracture loads than zirconia frameworks.