The purpose of this study was to compare the retention of complete cast crown over amalgam ores, composite resin cores, and cast gold cores when cemented with three different luting agents. Eighteen core specimens each of amalgam(Bestaloy, Dong Myung, Seoul, Korea), composite resin (Z100, 3M Dental product, st. Paul, Minn) and type IV gold alloy (Ba-4, Heesung Engelhard Corp., Korea) were made in a customized milling stainless steel die. A wax pattern with a loop attached to occlusal surface was made for each core and a type II gold alloy casting was fabricated. The castings which had clinically acceptable marginal fit were used as test samples. The following luting cements were used to cement cast crowns on each core material : (1) zinc phosphate cement (Confi-dental Products Co., USA) (2) glass-ionomer cement (Fuji Plus, GC Industrial Corp., Tokyo, Japan) (3) resin cement (Panavia 21, Kuraray Co., USA). All cements were mixed according to manufacturers' instructions. A static load of 5kg was then applied for 10 minutes on the crowns. All specimens were stored in saline solution for 24 hours at $37^{\circ}C$ and thermocycled for 500 cycles. After storage and cycling, the tensile bond strengths were measured by using a universal testing machine (Instron Corp., Canton, Mass.) at a crosshead speed of 0.5mm/min. The results were as follows 1. The retentive strength of resin cement was the highest of alt three types of cement for resin core (p<0.05). 2. There was no statistical difference among the retentive strengths of three cements for amalgam core (p>0.05). 3. The retentive strength of resin cement was higher than that of zinc phosphate for cast core, but there was no difference between the retentive strength of glass ionomer cement and those of rein and zinc phosphate cement. 4. The retentive strength of the zinc phosphate cement for amalgam core was the highest of all type of cores.
Jo, Ji-Ho;Kim, Su-Gwan;Moon, Seong-Yong;Oh, Ji-Su;Park, Jin-Ju;Jung, Jong-Won;Yoon, Dae-Woong;Yang, Seong-Su;Jeong, Mi-Ae
Maxillofacial Plastic and Reconstructive Surgery
/
v.33
no.4
/
pp.352-358
/
2011
Purpose: This study evaluated the prognosis and survival rate of SLA (Sandblasted, Large-grit and Acid-etched) implants and it also evaluated the prosthodontic complications and the associated factors. Methods: Twenty seven patients (14 men and 13 women, mean age: 54.9) who visited Chosun University Hospital Implant Center with the chief desire for placement of an implant in an edentulous area from March, 2008 to December 2008 and who received placement of a SLA implant ($Implantium^{(R)}$, Dentium Co., Korea) were selected for this study. Results: The average follow-up period was 15 months and the study was based on the treatment records, radiographs and clinical examinations. A total of 69 implant cases were retrospectively assessed for the width and length of the implant, the primary and secondary stability, the combined surgery, the employed bone graft material and barrier membrane, the status of the opposing tooth, implant failure and the prosthetic complications. During the follow-up period (average: 15 months), the accumulative survival rate of the 69 implants in 27 patients was 100%. Complications such as infection, sinusitis and fixture exposure after surgery were seen for 5 implants in 4 patients. Complications such as screw loosening, contact loosening and peri-implant gingivitis after prosthodontic treatment occurred in 7 cases (10.14%). Conclusion: This study reports placement of SLA implants may cause various complications, yet the final accumulative survival rate was 100%. The SLA implant ($Implantium^{(R)}$) has an excellent clinical survival rate and outcome.
Park, Jung Min;Kim, Soung Min;Kim, Min Keun;Park, Young Wook;Myoung, Hoon;Lee, Byung Cheol;Lee, Jong Ho;Lee, Suk Keun
Maxillofacial Plastic and Reconstructive Surgery
/
v.35
no.1
/
pp.38-50
/
2013
Purpose: The aim of this study is to evaluate the effect and potential of electron beam (E-beam) irradiation treatment to the synthetic bony mixtures composed of hydroxyapatite (HA; Bongros$^{(R)}$, Bio@ Co., Korea) and tricalcium phosphate (${\beta}$-TCP, Sigma-Aldrich Co., USA), mixed at various ratios and of type I collagen (Rat tail, BD Biosciences Co., Sweden) as an organic matrix. Methods: We used 1.0~2.0 MeV linear accelerator and 2.0 MeV superconductive linear accelerator (power 100 KW, pressure 115 kPa, temperature $-30{\sim}120^{\circ}C$, sensor sensitivity 0.1~1.2 mV/kPa, generating power sensitivity 44.75 mV/kPa, supply voltage $5{\pm}0.25$ V) with different irradiation dose, such as 1, 30 and 60 kGy. Structural changes in this synthetic bone material were studied in vitro, by scanning electron microscopy (SEM), elementary analysis and field emission scanning electron microscope (FE-SEM), attenuated total reflection (ATR), and electron spectroscopy for chemical analysis (ESCA). Results: The large particular size of HA was changed after E-beam irradiation, to which small particle of TCP was engaged with organic collagen components in SEM findings. Conclusion: The important new in vitro data to be applicable as the substitutes of artificial bone materials in dental and medical fields will be able to be summarized.
This investigation was designed to compare the craniofacial and dental morphology of class III malocclusion with that of normal occlusin in children, and to determine the incidence of various class III craniofacial skeletal patterns. The material selected for this study consisted in standard lateral cephalograms of eighty two Korean children, forty one boys and forty one girls, aged 10 through 12 years, having class III malocclusion, and forty two Korean children, twenty boys and twenty two girls, with normal occlusion in the same age. Using the tracings of the standard lateral cephalograms, various angular and linear measurements were recorded, tabulated and statistically analyzed, and then the class III craniofacial skeletal morphology was divided into various patterns by the degree of SNA and SNB, which respectively were below, within or beyond the normal range of those of normal occlusion. The following characteristics of the craniofacial and dental morphology of class III malocclusion were observed. 1. The cranial base length of class III malocclusion was smaller than that of normal occlusion, and the small saddle angle was a characteristic figure of class III malocclucion. 2. Maxillary length of class III malocclusion was smaller than that of normal occlusion, and point A was retropositioned relative to cranial base but not PNS in class III malocclusion. Maxillary base inclination was not significantly different between the two, but occlusal plane to palatal plane was small in class III malocciusion. 3. The mandibular body length shown no difference between the two, but the mandibular body positioned anteriorly relative to cranial base in class III malocclusion. Ramus height, gonial angle, and mandibular effective length were large in class III malocclusion. Mandibular plane angle and joint angle had no difference between the two, and occlusal plane to mandibular plane angle was large in class III malocclusion. 4. Maxillary incisor inclination was not significantly different between class III malocclusion and normal occlusion, but mandibular incisors positioned and inclined lingually and consequently interincisal angle was large in class III malocclusion. 5. Class III malocclusion was divided into six categories of craniofacial skeletal pattern. The most common class III pattern was found to be one in which the maxilla was within the normal range of prognathism while the mandible extended beyond this range. The pattern in which the maxilla was below the normal range of prognathism while the mandible was within this range was approximately one fifth of the class III sample.
Journal of Korean Academy of Oral and Maxillofacial Radiology
/
v.28
no.2
/
pp.471-489
/
1998
For the successful endodontic treatment, root canal should be cleaned thoroughly by accurate mechanical and chemical canal preparation and sealed completely with canal filling material without damaging the periapical tissues. The accuracy of the root canal length measurement is a prerequisite for the success of the endodontic treatment, and the root canal length is often determined by the standard periapical radiographs and digital tactile sense. In this study, the accuracy and the clinical usefulness of Digora/sup (R)/, an intraoral digital imaging processor and the conventional standard radiographs were compared by measuring the length from the top of the file to the root apex. 30 single rooted premolars were invested in a uniformly sized blocks and No.25 K-file was inserted into and fixed in each canal. Each block was placed in equal distance and position to satisfy the principle of the bisecting angle and paralleling techniques and Digora/sup (R)/ system's image and standard periapical radiographs were taken. Each radiograph was examined by 3 different observers by measuring the length from top of the file to the root apex and each data was compared and analyzed. The results were as follows; 1. In the bisecting angle technique, the average difference between the Digora/sup (R)/ system and standard periapical radiograph was 0.002 mm and the standard deviation was 0.341 mm which showed no statistically significant difference between the two systems(p>0.05). Also, in the paralleling technique, the average difference between these two system was 0.007 mm and the standard deviation was 0.323 mm which showed no statistically significant difference between the two systems(p>0.05). 2. In Digora/sup (R)/ system, the average difference between the bisecting angle and paralleling technique was -0.336 mm and the standard deviation was 0.472 mm which showed a statistically significant difference between the two techniques(p<0.05). Also, in the standard periapical radiographs, the average difference between the bisecting angle and paralleling technique was 0.328 mm and the standard deviation was 0.517 mm which showed a statistically significant difference between these two techniques(p<0.05). 3. In Digora/sup (R)/ system and the standard periapical radiographs. there was a statistically significant difference between the measurement using the bisecting angle technique and the actual length(p<0.05), But there was no statistically significant difference between the measurement using the paralleling technique and the actuallength(p>0.05). In conclusion. the determination of the root canal length by using the Digora/sup (R)/ system can give us as good an image as the standard periapical radiograph and using the paralleling technique instead of the bisecting angle technique can give a measurement closer to the actual canal length. thereby contributing to a successful result. Also. considering the advantages of the digital imaging processor such as decreasing the amount of exposure to the patient. immediate use of the image. magnification of image size. control of the contrast and brightness and the ability of storing the image can give us good reason to replace the standard periapical radiographs.
STATEMENT OF PROBLEM: While patient-centered outcomes are usually not reported, these may represent major aspects of the implant success for the patient. Use of a well-designed patient survey form can be an invaluable asset to the implant practitioners. PURPOSE: The objective of this study was to investigate patient satisfaction after implant therapy by means of a questionnaire. MATERIAL AND METHODS: South Korean patients (n = 100), who visited the dental examination center of Soon Chun Hyang university hospital, were asked to fill out the satisfaction questionnaire regarding aspects of cost, comfort, esthetics, chewing, gingival health, food impaction, phonetic aspect, screw loosening, and general satisfaction. Responses to statements were given on the Likert response scale. Four experimental groups of patients were distinguished with various location ($A_1,\;A_2,\;A_3$), year ($B_1,\;B_2,\;B_3$), number of implant replacements ($C_1,\;C_2,\;C_3$), and treatment cost ($D_1,\;D_2,\;D_3$). The reliability of the response scales was measured by calculation of its internal consistency, expressed as Cronbach's ${\alpha}$. The scales were distinguished by means of factor analysis method. Possible differences in scale scores among the groups were assessed by One-way ANOVA (${\alpha}$= 0.05). RESULTS: Patients responded to most of the statements with high satisfaction. But the mean scale score of statement about cost was low. After the verification of internal consistency and factor analysis, five components, e.g. general satisfaction, comfort, chewing efficiency, esthetics, and phonetic aspect were grouped together. These components could be explained with common meaning and the first factor was named as 'general satisfaction'. Differences in patient satisfaction on the scale with esthetics were present between patients who have been wearing the implant prosthesis less than three years and those more than seven years ($B_1<B_3$). CONCLUSION: The patients were generally satisfied with the outcome of implant treatment. But the patients' major complaint was high cost and while the statistically significant difference was not shown, the satisfaction scale about food impaction and esthetics was low. So the continuing efforts to make improvements about these problems are needed for the implant practitioners.
Purpose: The aim of this prospective pilot study was to compare alveolar ridge preservation (ARP) procedures with open-healing approach using a single-layer and a double-layer coverage with collagen membranes using radiographic and clinical analyses. Methods: Eleven molars from 9 healthy patients requiring extraction of the maxillary or mandibular posterior teeth were included and allocated into 2 groups. After tooth extraction, deproteinized bovine bone mineral mixed with 10% collagen was grafted into the socket and covered either with a double-layer of resorbable non-cross-linked collagen membranes (DL group, n=6) or with a single-layer (SL group, n=5). Primary closure was not obtained. Cone-beam computed tomography images were taken immediately after the ARP procedure and after a healing period of 4 months before implant placement. Radiographic measurements were made of the width and height changes of the alveolar ridge. Results: All sites healed without any complications, and dental implants were placed at all operated sites with acceptable initial stability. The measurements showed that the reductions in width at the level 1 mm apical from the alveolar crest (including the bone graft) were $-1.7{\pm}0.5mm$ in the SL group and $-1.8{\pm}0.4mm$ in the DL group, and the horizontal changes in the other areas were also similar in the DL and SL groups. The reductions in height were also comparable between groups. Conclusions: Within the limitations of this study, single-layer and double-layer coverage with collagen membranes after ARP failed to show substantial differences in the preservation of horizontal or vertical dimensions or in clinical healing. Thus, both approaches seem to be suitable for open-healing ridge preservation procedures.
Journal of Dental Rehabilitation and Applied Science
/
v.25
no.4
/
pp.349-360
/
2009
Purpose: As the esthetic demands of dental implant patients are increased, the demands of zirconia as implant abutment material are also increased. It has non-metalic color, good biocompatibility, high strength and high toughness. Even thought the advatage of zirconia abutment, there are a few studies about mechanical properties of zirconia abutment. This study evaluated the mecanical strength with compressive bending strength and endurance limit of implant-zirconia abutment assembly. Materials and Methods: Static and cyclic loading of implant-Zirconia abutment assembly were simulated under worst case condition according to ISO. Test groups were implants of external butt joint with straight regular diameter and angled regular diameter zirconia abutment, implant of external butt joint with narrow straight diameter zirconia abutment and implant of internal conical joint with straight narrow diameter zirconia abutment. All test group were evaluated the mecanical strength with compressive bending strength and endurance limit. After fatique testing, fracture surface were examined by SEM. Results: The compressive bending strengths exceed 927N. Regular diameter zirconia abutment were stronger than narrow diameter zirconia abutment(P<.05). The endurance limits ranged from 503N to 868N. Conclusion: Within the limitation of this study, zirconia implant abutment exceeded the estabilished values for maximum incisal biting forces reported in the literature.
Statement of problem: One of common problems associated with dental implant is the loosening of abutment screws that retain the implants. Purpose : This study was performed to investigate the influence of abutment screw length and repeated tightening on screw loosening in dental implant. Material and method: Forty nine Hexplants (13mm length, 4.3mm diameter, Ti grade IV, Warantec. Co. Ltd. Seongnam, Korea) and cementation type abutments(straight abutment) and abutment screws (0.4mm/pitch) were divided into 7 groups, depending on abutment screw length. Each implant and abutment was tightened to 30Ncm by torque controller(MGT50, MARK-10 Inc., USA) and the removal torque values were measured during 10 consecutive closure/opening trials. Results and Conclusion: The results of comparing the removal torque value are as follows : 1. There is no significant difference in the removal torque value between groups in 10 consecutive closure/opening trials (p = 0.97). 2. If the fractured abutment screw is engaged in longer than 2.425 thread length, there is no significant difference in the preload between the fractured abutment screw and the new abutment screw when both are equally tightened to 30 Ncm. 3. The removal torque value in the 1st trial(24.510 Ncm) was lower than that in the 2nd, 3rd, 4th, 5th, 6th, 7th trials and the removal torque value in the 2nd trials(25.551 Ncm) was maximum and was decreased in 1311owing trials. The removal torque value in the 1st trial was significantly lower than that in the 2nd, 3rd, 4th trials and was significantly higher than that in the 8th, 9th, l0th trials(p<0.05). 4. In the 2nd, 3rd, 4th, 5th, 6th, 7th trials, the abutment screw was mainly influenced by settling effect and the higher preload was obtained In the 8th, 9th, l0th trials, the abutment screw was mainly influenced by adhesive wear and the progressively lower preload was obtained.
Statement of problem : Accurate impression is essential to success of implant prostheses. But there have been few studies about the accuracy of fixture-level impression technique in internal connection implant system. Purpose: This study evaluated the accuracy of splinted fixture-level impression technique using clinical methods and the effect of internal hex on fit of superstructure in internal connection implant system (Astra Tech). Material and method : Two metal master frameworks made from two abutments (Cast-to Abutment ST) each for parallel and divergent conditions and a corresponding. passively fitting, dental stone master cast with four future replicas (Fixture Replica ST) were fabricated. Ten dental stone casts were made with vinyl polysiloxane impressions from the master cast by acrylic resin splinted fixture-level impression technique. To evaluate the accuracy of impression technique, the fit of master frameworks for test models was evaluated using screw resistance test (SRT) and one-screw test. The results of SRT were recorded as SRT values from grade 1 to grade 5 by 1/4 turn. And to evaluate the effect of hex on fit of superstructure, the same tests were performed after removing hexes of master frameworks. Results: 1. There was only one case (2.5%) showing SRT value of test model below ade 2 in total before and after removing hexes of master frameworks. And, by removing hexes. SRT values decreased in only one test model (5%) and did not change in 17 test models (85%). 2. SRT values of the 1$^{st}$ screws were grade 2 in 80% of cases before, and grade 1 in 80% of cases after removing hexes. And, by removing hexes, SRT values decreased in 72.5% of cases. 3. SRT values of the 2$^{nd}$ screws were grade 3 in 85% of cases before, and grade 3 in 95% of cases after removing hexes. And, by removing hexes, SRT values did not change in 85% of cases. 4. There were only 2 cases regarded as acceptable fit by one-screw test, and SRT values of 2$^{nd}$ screws of both cases were grade 2. Conclusion. Within the limitations of this study, future-level impression of internal connection implant system is considered to obtain inaccurate working cast, even using acrylic resin splinted impression technique. And, it is considered to be unable improve the fit to remove the hexes of implant restoration.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.