• Title/Summary/Keyword: dental implant CT

Search Result 130, Processing Time 0.031 seconds

A study on sagittal root position of maxillary anterior teeth in Korean (한국인에서 상악 전치의 시상 치근 위치에 대한 연구)

  • Kong, Hyun-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.2
    • /
    • pp.88-94
    • /
    • 2020
  • Purpose: The purpose of this study was to analyze the sagittal root position of maxillary anterior teeth and report the frequency of each classification in Korean for immediate implant placement. Materials and Methods: A retrospective review of cone-beam computed tomography (cone-beam CT) images was conducted on 120 patients (60 male and 60 female) who fulfilled the inclusion criteria. After reorientation of the axis, cone-beam CT images were evaluated and the relationship of the sagittal root position (SRP) of the maxillary anterior teeth to its associated osseous housing was recorded. Class I, II, and III were classified respectively when the root was positioned on the labial, central, and palatal aspect of the alveolar bone. Class IV was the position that at least two thirds of the root is engaging both the labial and palatal cortical plates. Then, the angulation of the root axis and the alveolar bone axis was measured. Descriptive statistics and Kruskal-Wallis test were used to compare the angulation according to the root position and SRP class. Results: The frequency distribution of sagittal root position of maxillary anterior teeth indicated that 81.1%, 10.3%, 1.9%, and 6.7% were classified as Class I, II, III, and IV, respectively. The sagittal angulation at approximately 77.5% of central incisor, lateral incisor, and canine was < 20 degrees, but the angle at more than 42.7% of canine was ≥ 20 degrees. Within the class, the angulation was statistically significantly greater in Class I (16.19) compared to Class II (8.72) and Class III (9.93), and smaller in Class IV (3.79). Conclusion: Within the limitation of this study, a majority of the maxillary anterior roots were positioned close to the buccal cortical plate. However, some roots have very thin alveolar bone and sagittal angulation larger than 30 degrees. Therefore, cone-beam CT analyses of the sagittal root position and the sagittal angulation are recommended for the selection of the appropriate dental implant treatment approach.

Patients satisfaction for implant supported overdenture with small diameter implant (작은 직경 임플란트를 이용한 임플란트 지지 피개의치에 대한 환자 만족도 조사)

  • Lee, Sang-Yeup;Choi, Dae-Gyun;Paek, Jang-Hyun;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.1
    • /
    • pp.29-37
    • /
    • 2011
  • Purpose: In cases when implant supported overdenture is made by using standard size implant, additional procedure such as bone surgery and bone grafting can be required. And it gives burden to doctor and patient in terms of cost. Therefore, it is necessary to find the implant therapy for the edentulous patients in making denture with accordable cost and simple procedure. Materials and methods: Edentulous patients with upper and lower dentures participated in this study. Before the operation, survey about patient's satisfaction to the existing dentures was carried out. Surgical procedures included four small diameter implants installation anterior area and immediate loading. One and three month after the procedure, the same survey about patient's satisfaction was carried out, and radiography was taken. Results: We are doing research to the nine patients. Survival rate is 97.2 percent. The comparison of patient's satisfaction before and after surgery is performed based on oral health impact profile 49. We analyze mainly with masticatory discomfort, retention, aesthetics, social problem, psychological discomfort problems. As a result, satisfaction level is increased at all factors. Retention is the most increased satisfactory factor followed by mastication difficulty, pronunciation, psychological discomfort, social discomfort, aesthetics in order. Marginal bone loss is 0.21 mm at 12 weeks after implant placement. Conclusion: This research reveals that the denture supported by mini dental implant increases patient's satisfaction. This study will be continued with more patients for a long time and we are scheduled for taking additional radiography to check whether peri-implant bone resorption occurs or not.

Automatic Sagittal Plane Detection for the Identification of the Mandibular Canal (치아 신경관 식별을 위한 자동 시상면 검출법)

  • Pak, Hyunji;Kim, Dongjoon;Shin, Yeong-Gil
    • Journal of the Korea Computer Graphics Society
    • /
    • v.26 no.3
    • /
    • pp.31-37
    • /
    • 2020
  • Identification of the mandibular canal path in Computed Tomography (CT) scans is important in dental implantology. Typically, prior to the implant planning, dentists find a sagittal plane where the mandibular canal path is maximally observed, to manually identify the mandibular canal. However, this is time-consuming and requires extensive experience. In this paper, we propose a deep-learning-based framework to detect the desired sagittal plane automatically. This is accomplished by utilizing two main techniques: 1) a modified version of the iterative transformation network (ITN) method for obtaining initial planes, and 2) a fine searching method based on a convolutional neural network (CNN) classifier for detecting the desirable sagittal plane. This combination of techniques facilitates accurate plane detection, which is a limitation of the stand-alone ITN method. We have tested on a number of CT datasets to demonstrate that the proposed method can achieve more satisfactory results compared to the ITN method. This allows dentists to identify the mandibular canal path efficiently, providing a foundation for future research into more efficient, automatic mandibular canal detection methods.

Full-mouth rehabilitation of a patient with loss of posterior support and collapsed occlusion utilizing dental CAD-CAM system (구치부 지지 소실 및 무너진 교합관계를 보이는 환자에서 Dental CAD-CAM system을 활용한 완전 구강 회복 증례)

  • Jung, Jiwon;Heo, Seong-Joo;Kim, Seong-Kyun;Koak, Jai-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.44-54
    • /
    • 2022
  • Without proper treatment on the multiple tooth missing area, the lack of posterior support and the supra-eruption of the teeth cause many severe complications of occlusion, vertical dimension and masticatory function. This report is a case of full-mouth rehabilitation of a patient with loss of posterior support and collapsed occlusion due to missing teeth area left untreated for a long time. The patient who is 68-year old male patient had some teeth fallen out while removing his old maxillary denture and was complaining about pain in the region of anterior teeth due to traumatic contact. The vertical dimension was corrected by 4 mm from the top cervical point of the canine through various evaluations and the edentulous area was treated with the implant fixed prostheses through computer guided implant surgery based on the diagnosis and treatment plan for definitive prostheses supported by computed tomography (CT) data analysis and CAD-CAM (Computer-aided design/computer-aided manufacturing) technique. After full mouth rehabilitation, the patient was very satisfied with remarkable improvements in mastication, function, and aesthetics.

Measurement of maxillary sinus volume and available alveolar bone height using computed tomography (치과 임플란트 수술 계획시 CT를 이용한 상악동 체적 및 치조골량 측정)

  • Lee Jae-Hak;Han Won-Jeong;Choi Young Hi;Kim Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.33 no.1
    • /
    • pp.35-41
    • /
    • 2003
  • Purpose: To aid in determining the volume of graft bone required before a maxillary sinus lift procedure and compare the alveolar bone height measurements taken by panoramic radiographs to those by CT images. Materials and Methods : Data obtained by both panoramic radiographs and CT examination of 25 patients were used in this study. Maxillary sinus volumes from the antral floor to heights of 5 mm, 10 mm, 15 mm, and 20 mm, were calculated. Alveolar bone height was measured on the panoramic images at each maxillary tooth site and corrected by magnification rate (PBH). Available bone height (ABH) and full bone height (FBH) was measured on reconstructed CT images. PBH was compared with ABH and FBH at the maxillary incisors, canines, premolars, and molars. Results: Volumes of the inferior portion of the sinuses were 0.55 ± 0041 ㎤ for 5 mm lifts, 2.11 ± 0.68 ㎤ for 10 mm, 4.26 ± 1.32 ㎤ for 15 mm, 6.95 ± 2.01 ㎤ for 20 mm. For the alveolar bone measurement, measurements by panoramic images were longer than available bone heights determined by CT images at the incisor and canine areas, and shorter than full bone heights on CT images at incisor, premolar, and molar areas (p<0.001). Conclusion: In bone grafting of the maxillary sinus floor, 0.96 ㎤ or more is required for a 5 mm-lift, 2.79 ㎤ or more for a 10 mm-lift, 5.58 ㎤ or more for a 15 mm-lift, and 8.96 ㎤ or more for a 20 mm-lift. Maxillary implant length determined using panoramic radiograph alone could result in underestimation or overestimation, according to the site involved.

  • PDF

Bone density around the fixture after function of implant molar prosthesis using CBCT (임플란트 보철 기능후 고정체 주변 콘빔CT 골밀도 평가)

  • Jung, Jae-Hyun;Hwang, In-Taik;Jung, Byung-Hyun;Kim, Jae-Duk;Kang, Dong-Wan
    • Imaging Science in Dentistry
    • /
    • v.40 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • Purpose : The purpose of this study was to examine the significance of increased bone density according to whether bone grafts were applied using demographic data with Cone Beam Computed Tomography (CBCT) and to compare the bone densities between before and after implant prosthesis using the Hounsfield index. Materials and Methods : Thirty-six randomly selected computed tomography (CT) scans were used for the analysis. The same sites were evaluated digitally using the Hounsfield scale with V-Implant $2.0^{TM}$, and the results were compared with maxillary posterior bone graft. Statistical data analysis was carried out to determine the correlation between the recorded Hounsfield unit (HU) of the bone graft and implant prosthesis using a Mann-Whitney U test and Wilcoxon Matched-pairs test. Results : The bone grafted maxillary posterior teeth showed an increase in the mean values from-157 HU to 387 HU, whereas non-grafted maxillary posterior teeth showed an increase from 62 HU to 342 HU. After implantation, the grafted and non-grafted groups showed significantly higher bone density than before implantation. However, the grafted group showed significantly more changes than the non-grafted group. Conclusion : Bone density measurements using CBCT might provide an objective assessment of the bone quality as well as the correlation between bone density (Hounsfield scale) and bone grafts in the maxillary molar area.

A comparative biomechanical study of original and compatible titanium bases: evaluation of screw loosening and 3D-crown displacement following cyclic loading analysis

  • Oziunas, Rimantas;Sakalauskiene, Jurgina;Jegelevicius, Darius;Januzis, Gintaras
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.2
    • /
    • pp.70-77
    • /
    • 2022
  • PURPOSE. This study evaluated screw loosening and 3D crown displacement after cyclic loading of implant-supported incisor crowns cemented with original titanium bases or with three compatible, nonoriginal components. MATERIALS AND METHODS. A total of 32 dental implants were divided into four groups (n = 8 each): Group 1 used original titanium bases, while Groups 2-4 used compatible components. The reverse torque value (RTV) was evaluated prior to and after cyclic loading (1,200,000 cycles). Samples (prior to and after cyclic loading) were scanned with a microcomputed tomography (micro-CT). Preload and postload files were superimposed by 3D inspection software, and 3D crown displacement analysis was performed using root-mean-square (RMS) values. All datasets were analyzed using one-way ANOVA and Tukey's post hoc analysis. RESULTS. Significant variations were observed in the postload RTV, depending on the titanium base brand (P < .001). The mean postload RTVs were significantly higher in Groups 1 and 2 than in the other study groups. While evaluating 3D crown displacement, the lowest mean RMS value was shown in the original Group 1, with the highest RMS value occurring in Group 4. CONCLUSION. Within the limitations of this in vitro study and under the implemented conditions, it was concluded that the manufacturer brand of the titanium base significantly influenced screw loosening following the fatigue test and influenced 3D crown displacement after cyclic loading.

Adjunctive effect of 470-nm and 630-nm light-emitting diode irradiation in experimental periodontitis treatment: a preclinical study

  • Dongseob Lee;Jungwon Lee;Sun-Hee Ahn;Woosub Song;Ling Li;Yang-Jo Seol;Yong-Moo Lee;Ki-Tae Koo
    • Journal of Periodontal and Implant Science
    • /
    • v.54 no.1
    • /
    • pp.13-24
    • /
    • 2024
  • Purpose: This study investigated the adjunctive effect of light-emitting diodes (LEDs) in the treatment of experimental periodontitis. Methods: Experimental periodontitis was induced by placing ligatures around the mandibular second, third, and fourth premolars of 6 beagles for 3 months. After ligature removal, periodontitis progressed spontaneously for 2 months. The animals' hemimandibles were allocated among the following 3 groups: 1) no treatment (control), 2) scaling and root planing (SRP), and 3) SRP with LED irradiation at 470-nm and 630-nm wavelengths (SRP/LED). The probing pocket depth (PPD) and gingival recession (GR) were measured at baseline, 6 weeks, and 12 weeks. The clinical attachment level (CAL) was calculated. After 12 weeks, histological and histomorphometric assessments were performed. The distances from the gingival margin to the apical extent of the junctional epithelium (E) and to the connective tissue (CT) attachment were measured, as was the total length of soft tissue (ST). Results: PPD and CAL increased at 12 weeks compared with baseline in the control group (6.31±0.43 mm to 6.93±0.50 mm, and 6.46±0.60 mm to 7.61±0.78 mm, respectively). PPD and CAL decreased at 12 weeks compared with baseline in the SRP group (6.01±0.59 to 4.81±0.65 mm, and 6.51±0.98 to 5.39±0.93 mm, respectively). PPD and CAL decreased at 12 weeks compared with baseline in the SRP/LED group (6.03±0.39 to 4.46±0.47 mm, and 6.11±0.47 to 4.78±0.57 mm, respectively). The E/ST and CT/ST ratios significantly differed among the 3 groups (P<0.05). The clinical parameters and histologic findings demonstrated that 470-nm and 630-nm wavelength LED irradiation accompanying SRP could improve treatment results. Conclusions: Within the study limitations, 470 nm and 630 nm wavelength LED irradiation might provide additional benefits for periodontitis treatment.

The thickness of facial and palatal bone of maxillary anterior natural teeth: radiographic analysis using computed tomography (전산화 단층 촬영을 이용한 상악 전치부 자연치의 순측과 구개측 골의 두께 계측)

  • Bae, Soo-Yong;Park, Jung-Chul;Sohn, Joo-Yeon;Um, Yoo-Jung;Jung, Ui-Won;Kim, Chang-Sung;Cho, Kyoo-Sung;Chai, Jung-Kiu;Kim, Chong-Kwan;Choi, Seong-Ho
    • The Journal of the Korean dental association
    • /
    • v.47 no.10
    • /
    • pp.669-676
    • /
    • 2009
  • Purpose : Anterior region is crucial area for esthetic implant restoration. However, the alveolar process undergoes atrophy after removal of teeth and creates unfavorable situation for implant installation. The knowledge of the thickness of alveolar bone is required to estimate and expect the bone resorption after extraction. The aim of this study is to measure facial, palatal and faciopalatal bone thickness on maxillary anterior teeth. Methods : Facial, palatal, and faciopalatal bone thickness were measured on the computed tomography (CT) images from 57 patients, using an image analyzer program (Ondemand$3D^{(R)}$, Cybermed, Seoul, Korea). Results : The thickness of facial bone in incisors, lateral incisors and canines were less than 1 mm. The thickness of facial bone increased from anterior to posterior region and the thickness of palatal bone increased from posterior to anterior region. Conclusion : The measurement can be used for planning implant surgery before extraction. CT has are clinically useful in the evaluation of thickness of alveolar bone.

  • PDF

STABILITY OF SIMULTANEOUS IMPLANTATION WITH AUTOGENOUS ILIAC BONE GRAFT IN THE SEVERELY ATROPHIC MAXILLA (심하게 흡수된 상악골에서 자가 장골 이식술과 동시에 시행한 임프란트 치료의 안정성에 대한 연구)

  • Byun, June-Ho;Park, Bong-Wook;Jeong, Hee-Chan;Kim, Jong-Ryoul
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.6
    • /
    • pp.570-578
    • /
    • 2006
  • A severely atrophic maxilla may disturb the proper implant placement. The various bone graft techniques are required for simultaneous or delayed implantation in the cases of atrophic alveolar ridges. We present 11 consecutive patients treated with simultaneous implantation using the autogenous inlay and/or onlay bone grafts from iliac crest to the floor of the maxillary sinus and the alveolar crest. In the cases of atrophic maxilla, a total 69 implants were simultaneously placed with autogenous iliac bone graft. 40 fixtures were inserted in the sinus floor simultaneously with subantral block bone graft, the other 29 fixtures were placed in the anterior or premolar areas with block or particulate bone graft. The vertical alveolar bone height was measured with Dental CT at the preoperation and 6 months postoperation. Moreover, the implant stability quotients (ISQ) were measured by $Osstell^{TM}$ during second implant surgery at 6 months later of first implantation. All implants were obtained successful osseointegration with the grafted bone. The mean vertical increases were 3.9mm in the anterior ridges and 12.8mm in the posterior ridges. During the second implant surgery, mean ISQ were 62.95 in the anterior ridge and 61.32 in the posterior ridge. We concluded that the simultaneous implantation with autogenous iliac bone graft were stable and available methods for severely atrophic maxilla.