• 제목/요약/키워드: dental cements

검색결과 180건 처리시간 0.022초

생체외(生體外) 섬유아세포(纖維芽細胞) 배양법(培養法)을 이용(利用)한 합착성(合着性) 시멘트의 독성(毒性) 평가(評價)에 관(關)한 연구(硏究) (A STUDY OF THE CYTOTOXICITY OF DENTAL CEMENTS ON HUMAN FIBROBLAST IN VITRO)

  • 맹형렬;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제14권1호
    • /
    • pp.7-24
    • /
    • 1989
  • The purpose of the study was to evaluate the cytotoxic effects of polycarboxylate cements and zinc phosphate cements in vitro. Human fibroblasts were cultured in ${\alpha}$-MEM, and each cement was manually mixed and filled in glass ring cylinder (8${\times}$8mm in diameter, in height.) Cement filled cylinders were placed in the center of the dish (35mm in diameter) containing 3ml of ${\alpha}$-MEM. Millipore filters to simulate dentinal barrier were also placed between the cylinder and the dish, then stored in 5% $CO_2$ containing chamber for 1 and 2 weeks at the temperature of $36.6^{\circ}C$. The results of the experiments were analyzed by counting the cells in the period of one week and two weeks respectively, and were assessed by calculating the cell multiplication rate and the relative growth rate. The experimental groups and the control group were compared. The results of the study were summarized as follows. 1. Durelone brand of the polycarboxylate cements showed marked cytotoxicity after one week, but after two weeks the toxicity decreased remarkably. Poly-F brand exhibited moderate cytotoxicity after one week, but after two weeks the toxicity slightly decreased. HY-BOND brand was weakly cytotoxic after one week, but after two weeks the toxicity became significant. 2. The cytotoxicity of the zinc phosphate cements was negligible after one week, but after two weeks Lee Smith brand revealed considerable cytotoxicity. 3. In general, the zinc phosphate cements were less cytotoxic than the polycarboxylate cements.

  • PDF

Evaluation of the radiopacity of restorative materials with different structures and thicknesses using a digital radiography system

  • Yaylaci, Ayla;Karaarslan, Emine Sirin;Hatırli, Huseyin
    • Imaging Science in Dentistry
    • /
    • 제51권3호
    • /
    • pp.261-269
    • /
    • 2021
  • Purpose: The aim of this study was to evaluate the radiopacities of various types of restorative materials with different thicknesses compared with enamel, dentin, and aluminum. Materials and Methods: Four bulk-fill resins, 2 hybrid ceramics, 2 micro-hybrid resin composites, 6 glass ionomer-based materials, 2 zinc phosphate cements, and an amalgam were used in the study. Twelve disk-shaped specimens were prepared from each of 17 restorative materials with thicknesses of 1 mm, 2 mm, and 4 mm (n=4). All the restorative material specimens with the same thickness, an aluminum (Al) step wedge, and enamel and dentin specimens were positioned on a phosphor storage plate and exposed using a dental X-ray unit. The mean gray values were measured on digital images and converted to equivalent Al thicknesses. Statistical analyses were performed using 2-way analysis of variance and the Bonferroni post hoc test(P<0.05). Results: Radiopacity was significantly affected by both the thickness and the material type (P<0.05). GCP Glass Fill had the lowest radiopacity value for samples of 1 mm thickness, while Vita Enamic had the lowest radiopacity value for 2-mm-thick and 4-mm-thick samples. The materials with the highest radiopacity values after the amalgam were zinc phosphate cements. Conclusion: Significant differences were observed in the radiopacities of restorative materials with different thicknesses. Radiopacity was affected by both the material type and thickness.

Evaluation of shear bond strength between dual cure resin cement and zirconia ceramic after thermocycling treatment

  • Lee, Jung-Jin;Kang, Cheol-Kyun;Oh, Ju-Won;Seo, Jae-Min;Park, Ju-Mi
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권1호
    • /
    • pp.1-7
    • /
    • 2015
  • PURPOSE. This study was performed to evaluate shear bond strength (SBS) between three dual-cured resin cements and silica coated zirconia, before and after thermocycling treatment. MATERIALS AND METHODS. Sixty specimens were cut in $15{\times}2.75mm$ discs using zirconia. After air blasting of $50{\mu}m$ alumina, samples were prepared by tribochemical silica coating with $Rocatec^{TM}$ plus. The specimens were divided into three groups according to the dual-cure resin cement used: (1) Calibra silane+$Calibra^{(R)}$, (2) Monobond S+$Multilink^{(R)}$ N and (3) ESPN sil+$RelyX^{TM}$ Unicem Clicker. After the resin cement was bonded to the zirconia using a Teflon mold, photopolymerization was carried out. Only 10 specimens in each group were thermocycled 6,000 times. Depending on thermocycling treatment, each group was divided into two subgroups (n=10) and SBS was measured by applying force at the speed of 1 mm/min using a universal testing machine. To find out the differences in SBS according to the types of cements and thermocycling using the SPSS, two-way ANOVA was conducted and post-hoc analysis was performed by Turkey's test. RESULTS. In non-thermal aged groups, SBS of Multilink group (M1) was higher than that of Calibra (C1) and Unicem (U1) group (P<.05). Moreover, even after thermocycling treatment, SBS of Multilink group (M2) was higher than the other groups (C2 and U2). All three cements showed lower SBS after the thermocycling than before the treatments. But Multilink and Unicem had a significant difference (P<.05). CONCLUSION. In this experiment, Multilink showed the highest SBS before and after thermocycling. Also, bond strengths of all three cements decreased after thermocycling.

도재라미네이트에 사용되는 수종의 레진시멘트와 try-in paste의 색조 비교 (THE COLOR COMPARISON OF VARIOUS RESIN CEMENTS WITH TRY-IN PASTES USED IN PORCELAIN LAMINATE VENEER)

  • 안경희;박하옥;방몽숙;양홍서;박상원
    • 대한치과보철학회지
    • /
    • 제44권5호
    • /
    • pp.514-525
    • /
    • 2006
  • Statement of problem: The color change of final restoration resulting from resin cement is variable since the amount of the tooth is prepared is minimum. Purpose: The purpose of this study was to compare the color accuracy of try-in paste and their corresponding resin cements and the color stability of restoration intermediated resin cement according to two shades of three products(Rely-X. Variolink II. Choice). Material and method: Color was measured for porcelain disk sample without try-in paste, and porcelain disk sample intermediated by try-in paste and resin cement, then color differences were calculated. Results : 1. Color difference(${\Delta}E^*$) between try-in paste and resin cement showed the lowest value at Variolink II and increased in the order Choice and Rely-X statistically significant, and $?E^*$ of three resin cements was greater in A3 then A1. 2. The values of ${\Delta}L^*$ and ${\Delta}a^*$ between try-in paste and resin cement was in the increasing order of Variolink II, Choice and Rely-X. The ${\Delta}b^*$ value was increased in this order Choice, Rely-X and Variolink II in A1 on the other hand Variolink II, Rely-X and Choice in A3. 3. Color difference(${\Delta}E^*$) before and after resin cement showed the lowest value at Variolink II and increased in the order Rely-X and Choice. Conclusion : Above result revealed that the colors of try-in paste and resin cement were more or less accurate in the range of 0.35-1.95 of color difference which was unnoticeable with human eye, and Variolink II was superior to the other resin cements in color accuracy.

Glass ionomer cement의 상아질 결합력에 관한 연구 (BONDING STRENGTH OF GLASS-IOMOMER CEMENT AND COMPOSITE RESIN COMBINATION)

  • 엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제19권2호
    • /
    • pp.633-640
    • /
    • 1994
  • The tensile bond strength to dentin was measured for three glass-ionomer cement and composite resin combinations: two light-curing glass-ionomer cements(Vitrebond and XR - Ionomer) and one traditional glass - ionomer cement(Ketac - Bond), two adhesive systems(Scotchbond, and XR - Bonding System), and a corresponding composite resin. The bond strength of this "sandwich" was also compared with that of the same cements used in bulk. Vitredbond showed a significantly higher bond strength in bulk than did the other two cements. Of the sandwiches, the XR - Iomomer and XR - Bond combination showed a bond strength significantly higher than that of the Vitrebond and Scotchbond or Ketac- bond and Scotchbond combination. The fracture of the bond was mainly adhesive for Vitrebond, cohesive for XR - Ionomer when used in bulk and adhesive - cohesive when used in a sandwich, and cohesive for Ketac-Bond.

  • PDF

Degree of conversion of two dual-cured resin cements light-irradiated through zirconia ceramic disks

  • Kim, Min-Jeong;Kim, Kyo-Han;Kim, Young-Kyung;Kwon, Tae-Yub
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권4호
    • /
    • pp.464-470
    • /
    • 2013
  • PURPOSE. The aim of this Fourier transform infrared (FTIR) spectroscopic study was to measure the degree of conversion (DC) of dual-cured resin cements light-irradiated through zirconia ceramic disks with different thicknesses using various light-curing methods. MATERIALS AND METHODS. Zirconia ceramic disks (KT12) with three different thicknesses (1.0, 2.0, and 4.0 mm) were prepared. The light transmittance of the disks was measured using ultraviolet visible near-infrared spectroscopy. Four different light-curing protocols were used by combining two curing light modes (Elipar TriLight (standard mode) and bluephase G2 (high power mode)) with light-exposure times of 40 and 120 seconds. The DCs of the two dual-cured resin cements (Duo-Link and Panavia F2.0) light-irradiated through the disks was analyzed at three time intervals (3, 7, and 10 minutes) by FTIR spectroscopy. The data was analyzed using repeated measures ANOVA (${\alpha}$=.05).Two-way ANOVA and Tukey post hoc test were used to analyze the 10 minute DC results. RESULTS. The 1.0 mm thick disk exhibited low light transmittance (<25%), and the transmittance decreased considerably with increasing disk thickness. All groups exhibited significantly higher 10 minute DC values than the 3 or 7 minute values (P<.05), but some exceptions were observed in Duo-Link. Two-way ANOVA revealed that the influence of the zirconia disk thickness on the 10 minute DC was dependent on the light-curing methods (P<.001). This finding was still valid even at 4.0 mm thickness, where substantial light attenuation took place. CONCLUSION. The curing of the dual-cured resin cements was affected significantly by the light-curing technique, even though the additional chemical polymerization mechanism worked effectively.

치과용 시멘트 용액의 증발이 경화된 시멘트의 성질에 미치는 영향 (INFLUENCE OF THE EVAPORATOIN OF LIQUIDS OF DENTAL CEMENTS ON THE PROPERTIES OF HARDENED CEMENTS)

  • 김향경;박상진
    • Restorative Dentistry and Endodontics
    • /
    • 제22권1호
    • /
    • pp.156-169
    • /
    • 1997
  • This study was designed to evaluate the influences of evaporation of liquid of dental cements by drying during long term using. Zinc phosphate cement, polycarboxylate cement, and glass ionomer cement were used, and evaluated the properties as follows; consistency, setting time, film thickness, solubility, and compressive strength according to the ADA specification. The specimens of control group were made by mixing the newly opened liquid using the powder-liquid ratio recommended by the manufacturer, and the specimens of ES groups were made by mixing the 10% evaporated liquid by drying with the powder-liquid ratio recommeded by the manufacturer, and the specimens of EM group were made by mixing the 10% evaporated liquid with the powder-liquid ratio modified for standard consistency. The following conclusions were drawn ; 1. The viscosity of mixture of all kinds of cements were increased by the evaporation of liquid, especially the viscosity of glass ionomer cement were influenced significantly. 2. The amount of liquid should be increased to get a standard consistency at the using of evaporated liquid of cement, the most significant increase of liquid amount was required on Ketac-Cem. 3. The setting times were increased at both cases of mixing of evaporated liquid with powder - liquid ratio recommended by manufacturer or modifided through consistency test. 4. At an experimental group of mixing of the evaporated liquid with powder-liquid ratio recommended by manufacturer, solubility was decreased and film thickness was increased. 5. By the result of evaporation of cement liquid, the compressive strength of polycarboxylate cement was increased slightly and it of glass ionomer cement was increased, however, by the increase of amount of liquid to be possible to manipulate the compressive strength were decreased.

  • PDF

Effect of antioxidants on push-out bond strength of hydrogen peroxide treated glass fiber posts bonded with two types of resin cement

  • Khoroushi, Maryam;Mazaheri, Hamid;Tarighi, Pardis;Samimi, Pouran;Khalighinejad, Navid
    • Restorative Dentistry and Endodontics
    • /
    • 제39권4호
    • /
    • pp.303-309
    • /
    • 2014
  • Objectives: Hydrogen peroxide ($H_2O_2$) surface treatment of fiber posts has been reported to increase bond strength of fiber posts to resin cements. However, residual oxygen radicals might jeopardize the bonding procedure. This study examined the effect of three antioxidant agents on the bond strength of fiber posts to conventional and self-adhesive resin cements. Materials and Methods: Post spaces were prepared in forty human maxillary second premolars. Posts were divided into five groups of 8 each: G1 (control), no pre-treatment; G2, 10% $H_2O_2$ pre-treatment; G3, G4 and G5. After $H_2O_2$ application, Hesperidin (HES), Sodium Ascorbate (SA) or Rosmarinic acid (RA) was applied on each group respectively. In each group four posts were cemented with Duo-Link conventional resin cement and the others with self-adhesive BisCem cement. Push-out test was performed and data were analyzed using 2-way ANOVA and tukey's post-hoc test (${\alpha}=0.05$). Results: There was a statistically significant interaction between the cement type and post surface treatment on push-out bond strength of fiber posts (p < 0.001, F = 16). Also it was shown that different posts' surface treatments significantly affect the push-out bond strength of fiber posts (p = 0.001). $H_2O_2$ treated posts (G2) and control posts (G1) cemented with Duo-link showed the highest ($15.96{\pm}5.07MPa$) and lowest bond strengths ($6.79{\pm}3.94$) respectively. Conclusions: It was concluded that $H_2O_2$ surface treatment might enhance the bond strength of fiber posts cemented with conventional resin cements. The effect of antioxidants as post's surface treatment agents depends on the characteristics of resin cements used for bonding procedure.

레진 시멘트의 혼합 후 시간에 따른 피막도의 변화 (Effect of working time on the film thickness of dental resin cements)

  • 이유승;김성훈;이재봉;한중석;여인성;하승룡;김희경
    • 대한치과보철학회지
    • /
    • 제53권4호
    • /
    • pp.325-329
    • /
    • 2015
  • 목적: 본 연구에서는 임상에서 사용되는 몇 가지 레진 시멘트의 혼합 후 부하를 가하기까지의 시간에 따른 피막도의 변화를 비교하고, 혼합 후 작업 시간과 레진 시멘트의 피막도의 관계를 알아 보고자 하였다. 재료 및 방법: 네 종류의 레진 시멘트(Panavia F2.0, Clearfil SA Luting, Zirconite, RelyX U200)를 제조사의 지시대로 혼합한 후 두 장의 투명한 Mylar matrix strip 사이에 소량의 시멘트를 넣고 다양한 시간 간격(20, 40, 60, 80, 100, 120, 140, 160, 180, 200초) 후에 50 N의 부하를 가하고 광중합을 시행하였다. 각 시점에서의 피막도는 $1{\mu}m$ 단위까지 측정 가능한 디지털 피막도 측정기를 이용하여 각 시편 당 세 번씩 측정하여 평균값을 구하였으며, 선형회귀분석을 통하여 시간에 따른 측정값의 변화를 알아 보았다. 또한 Wilcoxon 검정을 사용하여 각 측정값과 제조사에서 제시한 작업 시간을 유의수준 0.05로 비교 분석하였다 ($\alpha$=.05). 결과: 본 연구에 사용된 모든 레진 시멘트에서 혼합 후 부하를 가하기까지 걸린 시간과 피막도는 선형회귀분석 결과 양의 상관관계를 갖는 일차함수적 패턴을 보였다. ISO기준에 따라 피막도가 $50{\mu}m$가 되는 시점까지의 시간은 각 레진 시멘트의 제조사가 제시한 작업 시간과 차이가 있었으나 통계적인 유의성은 없었다. 결론: 레진 시멘트의 피막도는 작업 시간의 증가에 따라 증가한다. 임상에서의 레진 시멘트의 작업 시간은 제조사에서 제시한 작업 시간과 차이가 있을 수 있다.

In vitro study of compressive fracture strength of Empress 2 crowns cemented with various luting agents

  • Kim Min-Ho;Yang Jae-Ho;Lee Sun-Hyung;Chung Hun-Young;Chang Ik-Tae
    • 대한치과보철학회지
    • /
    • 제39권3호
    • /
    • pp.260-272
    • /
    • 2001
  • All-ceramic restorations have had a more limited life expectancy than metal ceramic restorations because of their low strength. Their relatively lower strength and resistance to fracture have restricted the use of all-ceramic crowns to anterior applications where occlusal loads are lower. But there has been increasing interest in all-ceramic restorations because patients are primarily concerned with improved esthetics. Many efforts have been made to in prove the mechanical properties of dental ceramics. This study was designed to elucidate the influence of the luting agent on the strength of the Empress 2 crown (staining technique) cemented on human teeth. Seventy extracted human permanent molar teeth were chosen. Teeth were prepared for Empress 2 crowns with milling machine on a surveyor. A dental bur was placed in the mandrel that was positioned so that the long axis of the bur was perpendicular to the surveyor base. Dimensions of the Empress 2 crown preparation were $6^{\circ}$ taper on each side, $1.5{\pm}0.1mm$ shoulder margin, and 4mm crown height. The luting cements used in this study were as follow: 1. Uncemented 2. Zinc phosphate cements (Confi-Dental) 3. Conventional glass ionomer cement : Fuji 1 (GC) 4. Resin-modified glass ionomer cements : Fuji plus (GC) 5. Adhesive cements : Panavia F (Kuralay), Variolink II (Vivadent), Choice (Bisco). Fracture test using Instron. The crowns were loaded in compressive force to evaluate the effect of these cements on the breaking strength of these all-ceramic crowns. A steel ball with a diameter of 4mm was placed on the occlusal surface and load was applied to the steel ball by a cylindrical bolt with a crosshead speed of 0.5mm per minute until fracture occurred. The fractured surface was examined using Scanning Electron Microscopic Image (SEM) to discover the correlation between fracture strength and bonding capacity. Within the limitation of this in vitro study design, the results were as follows : 1. fomentations significantly increased the fracture resistance of Empress ceramic crowns compared to control. Uncemented (206.9 N): ZPC (812.9 N): Fuji 1 (879.5 N): Fuji Plus (937.7 N): Choice (1105.4 N): Variolink II (1221.1 N): Panavia F (1445.2 N). 2. Resin luting agent, treated by a silane bond enhancing agents, yielded a significant increase in fracture resistance. In some of the Panavia F group, a fracture extended into dentin. 3. According to SEM images of fractured Empress crowns, the stronger the bond at both interfaces(crown and die), the more fracture strength was acquired.

  • PDF