• 제목/요약/키워드: dental alloy

검색결과 486건 처리시간 0.031초

Comparison of the cyclic fatigue resistance of One Curve, F6 Skytaper, Protaper Next, and Hyflex CM endodontic files

  • Charlotte Gouedard;Laurent Pino;Reza Arbab-Chirani;Shabnam Arbab-Chirani;Valerie Chevalier
    • Restorative Dentistry and Endodontics
    • /
    • 제47권2호
    • /
    • pp.16.1-16.9
    • /
    • 2022
  • Objectives: This study compared the cyclic fatigue resistance of One Curve (C wire) and F6 Skytaper (conventional austenite nickel-titanium [NiTi]), and 2 instruments with thermos-mechanically treated NiTi: Protaper Next X2 (M wire) and Hyflex CM (CM wire). Materials and Methods: Ten new instruments of each group (size: 0.25 mm, 6% taper in the 3 mm tip region) were tested using a rotary bending machine with a 60° curvature angle and a 5 mm curvature radius, at room temperature. The number of cycles until fracture was recorded. The length of the fractured instruments was measured. The fracture surface of each fragment was examined with a scanning electron microscope (SEM). The data were analyzed using one-way analysis of variance and the post hoc Tukey test. The significance level was set at 0.05. Results: At 60°, One Curve, F6 Skytaper and Hyflex CM had significantly longer fatigue lives than Protaper Next X2 (p < 0.05). No statistically significant differences were found in the cyclic fatigue lives of One Curve, F6 Skytaper, and Hyflex CM (p > 0.05). SEM images of the fracture surfaces of the different instruments showed typical features of fatigue failure. Conclusions: Within the conditions of this study, at 60° and with a 5 mm curvature radius, the cyclic fatigue life of One Curve was not significantly different from those of F6 Skytaper and Hyflex CM. The cyclic fatigue lives of these 3 instruments were statistically significantly longer than that of Protaper Next.

코발트 크롬 합금의 주조성에 미치는 타이타늄의 효과 (The Effect of Titanium on the Castability of Cobalt-Chrome Alloy)

  • 유수경;정희정;방몽숙;양홍서;임현필;윤귀덕;박상원
    • 구강회복응용과학지
    • /
    • 제27권1호
    • /
    • pp.73-79
    • /
    • 2011
  • 연구의 목적은 타이타늄이 함유된 코발트 크롬의 주조성에 타이타늄이 어떠한 영향을 미치는지 평가하기 위함이다. 원재료에는 코발트, 크롬, 몰리브덴, 실리콘, 망간, 탄소, 질소, 티타늄이 사용되었고 이것들을 정량계량하였다. $Biosil^F$ (Degudent, Germany)를 대조군으로 하였고, 실험군에는 티타늄을 1 wt% 에서 4 wt% 까지 각기 다른 함량으로 첨가하여 주조성을 평가하였다. 왁스 패턴은 $30{\times}40$ cm 크기의 직사각형 모양으로, 총 160개의 격자를 함유하고 있다. 원심주조기 (Neutrodyne Easy Ti: Manfredy)를 사용하여 왁스패턴을 주조하였다. 주조성의 평가는 왁스패턴의 4면이 완전한 격자의 수를 육안과 X-ray를 이용하여 검사하였다. 1 wt%에서 3 wt%의 티타늄을 함유한 금속은 대조군과 비슷한 주조성을 나타냈다. 4 wt%의 티타늄을 함유한 금속은 좋지 않은 결과를 보였다. 4 wt% 미만의 티타늄 함유한 실험군의 주조성은 대조군과 비슷하면서도 기계적인 물성은 증가됨을 보였으며 임상에서의 성공적인 사용을 가능케 한다.

카복실레이트계 시멘트의 접착력에 관한 비교 연구 (COMPARATIVE STUDIES OF THE ADHESIVE QUALITIES OF POLYCARBOXYLATE CEMENTS)

  • 이한무
    • 대한치과보철학회지
    • /
    • 제17권1호
    • /
    • pp.23-34
    • /
    • 1979
  • In this study, the adhesive strength of three commercial polycarboxylate cements to ten types of dental casting alloys, such as gold, palladium, silver, indium, copper, nickel, chromium, and human enamel and dentine were measured and compared with that of a conventional zinc phosphate cement. The $8.0mm{\times}3.0mm$ cylindrical alloy specimens were made by casting. The enamel specimens were prepared from the labial surface of human upper incisor, and the dentine specimens were prepared from the occulusal surface of the human molar respectively. Sound extracted human teeth, which had been kept in a fresh condition since, extraction, were mounted in a wax box with a cold-curing acrylic resin to expose the flattened area. The mounted teeth were then placed in a Specimen Cutter (Technicut) and were cut down under a water spray, and then the flat area on the all specimens were ground by hand with 400 and 600 grit wet silicone carbide paper. Two such specimens were then cemented together face-to-face with freshly mixed cement, and moderate finger pressure was applied to squeeze the cement to a thin and uniform film. All cemented specimens were then kept in a thermostatic humidor cabinet regulated at $23{\pm}2^{\circ}C.$ and more than 95 per cent relative humidity and tested after 24 hours and 1 week. Link chain was attached to each alloy specimen to reduce the rigidity of the jig assembly, and then all the specimens were mounted in the grips of the Instron Universal Testing Machine, and a tensile load was delivered to the adhering surface at a cross head speed of 0.20 mm/min. The loads to which the specimens were subjected were recorded on a chart moving at 0.50 mm/min. The adhesive strength was determined by measuring the load when the specimen separated from the cement block and by dividing the load by the area. The test was performed in a room at $23{\pm}2^{\circ}C.$ and $50{\pm}10$ per cent relative humidity. A minimum of five specimens were tested each material and those which deviated more than 15 per cent from the mean were discarded and new specimens prepared. From the experiments, the following results were obtained. 1) It was found that the adhesive strength of the polycarboxylate cement to all alloys tested was considerably greater than that of the zinc phosphate cement. 2) The adhesive strength of the polycarboxylate cements was superior to the non precious alloys, such as the copper, indium, nickel and chromium alloys, but it was inferior to the precious gold, silver and palladium alloys. 3) Surface treatment of the alloy was found to be an important factor in achieving adhesion. It appears that a polycarboxylate cement will adhere better to a smooth surface than to a rough one. This contrasts with zinc phosphate cements, where a rough helps mechanical interlocking. 4) The adhesion of the polycarboxylate cement with enamel was found superior to its adhesion with dentine.

  • PDF

Thermocycling이 첨상용 레진과 금속 의치상간의 전단결합강도에 미치는 영향 (The Effects of Thermocycling on the Shear Bond Strength between Metal Denture Base and Relining Resin)

  • 이준석
    • 구강회복응용과학지
    • /
    • 제21권2호
    • /
    • pp.95-103
    • /
    • 2005
  • Purpose: Recently, various metal primers have been developed, and these are known to increase the bond strength between metal and relining resin. In this study, the change in bond strength according to amount of thermocycling was evaluated. Materials and Methods: In this study, 216 specimens were fabricated. Tokuyama Rebase $II^{(R)}$(Tokuyama Corp., Japan) and $Kooliner^{(R)}$(GC America Inc., Japan) as relining material, and MR. $Bond^{(R)}$(Tokuyama Corp., Japan) and Alloy $Primer^{(R)}$(Kuraray Medical Inc., Japan) as a metal primers were used. Using Ni-Cr and various metal surface treatment methods, resin was bonded and the change in bond strength during thermocycling was measured. The data was analyzed by one-way ANOVA, t-test(p<.05 level of significance). Results: When comparing the groups with only sandblasting, rapid decrease in shear bond strength could be seen. In the groups using Tokuyama Rebase $II^{(R)}$, with the exception of the 1000 and 2000 cycle groups, each group showed statistically significant decrease in shear bond strength(p<0.05). In comparison according to relining materials, $Kooliner^{(R)}$ showed higher shear bond strength than Tokuyama Rebase $II^{(R)}$ in all groups. In groups using MR $bond^{(R)}$, $Kooliner^{(R)}$ had higher shear bond strength than Tokuyama Rebase $II^{(R)}$ but, there was no statistical significance(p<0.05). In the other groups, $Kooliner^{(R)}$ showed significantly higher shear bond strength(p<0.05). There was significant difference between groups with sandblasting and metal primer treatments(p<0.05). In comparison according to metal primer materials, Alloy $Primer^{(R)}$ showed the highest shear bond strength but there was no statistical significance(p>0.05). According to the number of thermocycling cycles, when using Tokuyama Rebase $II^{(R)}$, there were no significant differences between the 0, 1000 and 2000 cycle groups regardless of the type of metal primer. There were no differences between the 2000 and 3000 cycle groups. When using $Kooliner^{(R)}$, regardless of the type of metal primer, there were no significant differences between the 0, 1000, 2000 and 3000 cycle groups(p>0.05). Conclusion: The use of metal primers showed increase in bond strength, and the stability after to thermocycling has been authenticated. Thus, the use of metal primers in relining and rebasing of metal frameworks is essential. But when selecting the material various physical properties should be considered.

반복주조된 치과용 합금의 피착면 처리방법에 따른 접착성 수지와의 접착강도에 관한 실험적 연구 (AN EXPERIMENT STUDY ON THE BOND STRENGTH OF ADHESIVE RESINS TO SUEEXSSIVELY RECAST ALLOYS FOR REISN-BONDED RESTORATIONS)

  • 정금태;양재호;이선형;정헌영
    • 대한치과보철학회지
    • /
    • 제28권2호
    • /
    • pp.53-76
    • /
    • 1990
  • The purpose of this study was to evaluate the tensile bond strength of adhesive resins to successively recast Rexillium III and Degudent-U. Recasting was done 4times successively. Specimen $A_1$, were cast by new metal, and $A_2$ by surpus of $A_1$, $A_3$ by surplus of, $A_2$ $A_4$ by surplus of $A_3$, $A_5$ by surplus of $A_4$ plus 50% new metal. The types of surface treatment for resinbonded restoration in this experiment were electrolytic etching by OXY-ETCH(Oxy dental products, Inc., Hillside, New Jersey, U.S,A.), aluminum oxide blasting, anodic oxidation by EZ-OXISOR( Towagiken Co., Kyoto, Japan), electrotinplating by Kura Ace(Kuralay Co., Kyoto, Japan). Three kinds of cementing resin used in this study were Comspan(K.P. Cauil Co, Milford Delaware, U.S.A.), Super Bond C&B(Sun-Medical Co. Ltd., Kyoto,Japan), Panavia EX(Kuralay Co., Ltd., Osaka, Japan). Tensile bond strength was measured by Instron Universal testing machineModel 1125) and all the specimen were observed with SEM(JEOL, JSM-T2000) and mode of bond failure were recorded. The obtained results were as follows : 1. In electrolytic etched group, tensile bond strength was decreassed when recast alloy was used, and tensile bond strength of Compan and panavia EX were not significantly different(P>0.05). 2. In remaining group treated by aluminum oxide blasting, EZ-OXIOR, Kura Ace, tensile bond strength were not changed when recast alloy were used, and tensile bond strength of SuperBond(C&B and Panavia EX were not significantly different(P>0.05). 3. IN SEM evaluation, electrolytic etched group and electrotinplated group exhibited different image when recast alloy was used, and remaining groups treated by aluminum oxide blasting, EZ-OXISOR exhibited the same. 4. IN observation of bond failure, electrolytic etched group exhibited adhesive failure and remaing groups treated by aluminium oxid blasting, EZ-OXISOR, Kura Ace exhibited adhesive and cohesive failure.

  • PDF

수종의 인공 레진 치아의 마모저항성과 경도에 관한 비교 연구 (Comparative Study on Wear Resistance and Hardness of Several Artificial Resin Teeth)

  • 최유성;이준석;조인호
    • 구강회복응용과학지
    • /
    • 제24권2호
    • /
    • pp.129-146
    • /
    • 2008
  • 본 연구에서는 다양한 치과 수복재료에 대합되는 의치용 레진치의 마모저항성을 알아보기 위해 통상의 아크릴 릭 레진치인 $Trubyte^{(R)}$ $Biotone^{(R)}$ (Dentsply, U.S.A.)과 고강도 레진치인 Endura $Posterio^{(R)}$ (Shofu, Japan), Physio $Duracross^{(R)}$ (Nissin, Japan)를 수복재료인 금합금, 도재, 충전용 레진에 대합시켜 마모저항성을 비교 분석하였다. 또한 앞의 세 종류의 레진 인공치와 5종류의 의치세정제인 유한락스, 폴리덴트, 싸이덱스, 헥사메딘, 증류수를 사용하여 의치세정제 및 소독제가 경도에 미치는 영향을 비교 분석하여 다음과 같은 결과를 얻었다. 1. 대합되는 수복재료로 충전용 레진, 도재를 사용한 경우 $Trubyte^{(R)}$ $Biotone^{(R)}$, Endura $Posterio^{(R)}$, Physio $Duracross^{(R)}$ 순으로 교두정 높이감소가 컸으며 세 재료간의 유의한 차이를 보였다 (p<0.05). 2. 대합되는 수복재료로 금합금을 사용한 경우 $Trubyte^{(R)}$ $Biotone^{(R)}$, Endura $Posterio^{(R)}$, Physio $Duracross^{(R)}$ 순으로 교두정 높이 감소가 컸으며, 특히 $Trubyte^{(R)}$ $Biotone^{(R)}$ 이 다른 두 종류의 인공치보다 유의성 있게 높은 교두정 높이 감소를 보였다 (p<0.05). 3. 대합되는 수복재료로 충전용 레진, 금합금, 도재를 사용한 경우 모두 $Trubyte^{(R)}$ $Biotone^{(R)}$, Endura $Posterio^{(R)}$, Physio $Duracross^{(R)}$ 순으로 무게 감소가 컸으며, 세 재료간의 유의한 차이를 보였다 (p<0.05). 4. 의치세정제에 따른 경도 감소는 실험 전과 후의 측정치를 비교했을 때 모든 레진 인공치에서 유의성 있는 차이 를 나타내었다 (p<0.05). 5. 유한락스, 싸이덱스, 헥사메딘에 담구었던 레진 인공치에 의한 경도감소는 $Trubyte^{(R)}$ $Biotone^{(R)}$, Endura $Posterio^{(R)}$, Physio $Duracross^{(R)}$ 순으로 높은 감소를 보였고, 특히 $Trubyte^{(R)}$ $Biotone^{(R)}$이 다른 두 종류의 인공치보다 유의성 있게 높은 경도 감소를 보였다 (p<0.05). 이상의 실험 결과 마모저항성 실험에서는 최근에 개발된 Physio $Duracross^{(R)}$가 다른 두 종류의 레진 인공치에 비해 세 종류의 대합되는 수복재료 모두에서 높은 마모저항성을 보였고 특히 $Trubyte^{(R)}$ $Biotone^{(R)}$에 비해 유의성 있게 높은 마모저항성을 보였다. 경도 실험에서는 Physio $Duracross^{(R)}$와 Endura $Posterio^{(R)}$$Trubyte^{(R)}$ $Biotone^{(R)}$에 비해 유의성 있게 낮은 경도감소를 보였고 (p<0.05), 폴리덴트, 증류수에서는 유의한 차이를 보이지 않았다. 따라서, Physio $Duracross^{(R)}$가 세 종류의 레진 인공치에 비해 우수한 마모저항성을 보인다고 볼 수 있고, Endura $Posterio^{(R)}$와 함께 $Trubyte^{(R)}$ $Biotone^{(R)}$에 비해서 우수한 경도를 보인다고 볼 수 있지만, 단편적인 실험 결과이므로, 아직은 신중하게 고려되어야 하고, 더 많은 연구가 필요하다고 사료된다.

금 실린더의 제작법과 고정 방법이 임플랜트 지대주의 preload에 미치는 영향 (THE EFFECTS OF FABRICATION AND TIGHTENING METHODS OF GOLD CYLINDER ON THE PRELOAD OF THE IMPLANT ABUTMENT)

  • 조혜원;김성훈
    • 대한치과보철학회지
    • /
    • 제38권5호
    • /
    • pp.695-703
    • /
    • 2000
  • The purpose of this study was to evaluate the effects of fabrication and tightening methods of gold cyliner on the preload of the standard abutment. Three linear strain gauges (KFR-02N-120-C1-23, Kyowa, Japan) were mounted longitudinally on the 5.5mm Standard abutment (Nobel Biocare, Sweden) and three kinds of gold cylinders such as, as-received gold cylinder, gold cylinder after casting, and plastic cylinder after casting with type IV gold alloy were connected over the top of the standard abutment. Two kinds of tightening methods, such as manual torque with handhold screwdriver and electronic torque using Electronic torque controller were used to generate preload on the abutment. The result were as follows; 1. The preload generated by tightening cast plastic cylinder with handhold screw driver, was the lowest among the six groups. 2. The preload generated by cast plastic cylinder was lower than those by gold cylinders regardless of the tightening methods. 3. The electronic torque controller produced higher torque values than the handheld screwdriver.

  • PDF

수종 아말감의 Anodic Polarization에 관한 연구 (A STUDY ON THE ANODIC POLARIZATION OF DENTAL AMALGAMS)

  • 엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제14권1호
    • /
    • pp.199-204
    • /
    • 1989
  • The purpose of this study was to observe the anodic polarization curve from 4 kinds of low copper amalgam (Fine cut alloy, Spheralloy, Aristalloy and Amalcap) and 4 kinds of high copper amalgam (Dispersalloy, Sybraloy Orosphere and Tytin) obtained by using the potentiostat. The specimen made as the direction of manufacturer was stored at room temperature for about 7 days. The standard surface preparation was routinely carried out. The 0.9% saline solution was used as electrolyte in pH 6.8-7.0 at $37^{\circ}C$. The open circuit potential was determined after 30 minutes' immersion of specimen. The scan rate was 1mV/sec and the surface area of amalgam exposed to the solution was 0.785$cm^2$ for each specimen. All potentials reported are with respect to Ag/AgCl eelctrode. The following results were obtained. 1. The corrosion potential of high copper amalgams was higher than one of low copper amalgams, and the current density of high copper amalgam was lower than one of low copper amalgams. 2. The low copper amalgams had the similar pattern of polarization curve, but the high copper amalgams had the different pattern one another. 3. The polarization curve of Orosphere amalgam which is the admixed type was similar to one of low copper amalgam.

  • PDF

Pb-기판의 표면특성에 미치는 합금원소의 영향 (Effects of Alloying Elements on the Surface Characteristics of Pb-Substrate for Battery)

  • 오세웅;최한철
    • 한국표면공학회지
    • /
    • 제39권6호
    • /
    • pp.302-311
    • /
    • 2006
  • Nowadays the open-type lead-acid battery for vehicle use is being replaced with the sealed-type because it needs no maintenance and has a longer cycle life. Thus researches on this battery are being conducted very actively by many advanced battery companies. There is, however, a serious problem with the maintenance free(MF) battery that its cathode electrode has a limited cycle life due to a corrosion of grid. In this study, it was aimed to improve a corrosion resistance of the cathode grid which is commonly made of Pb-Ca alloy for a mechanical strength. For this purpose, various amounts of alloying elements such as Sn, Ag and Ba were added singly or together to the Pb-Ca alloys and investigated their corrosion behaviors. Batteries fabricated by using these alloys as cathode grids were subjected to life cycle test and their corrosion layers appeared at the interface between the grids and the active materials were carefully observed in order to clarify effects of alloying elements.

Corrosion Behavior of Hard Coated Ti-Zr-N Film on the Tool Steels

  • Eun, Sang-Won;Choe, Han-Cheol
    • Corrosion Science and Technology
    • /
    • 제9권6호
    • /
    • pp.289-293
    • /
    • 2010
  • To investigate the corrosion behavior of tools steel surface in various coating film, the surface of hard coated Ti-Zr-N film on the tool steel by using magnetron-sputtering methods was researched using various experimental methods. STD 61 steels were manufactured by using vacuum furnace and solutionized for 1hr at $1050^{\circ}C$. Steel surface was coated with Ti-Zr-N film at $150^{\circ}C$ and 100W for 1h by using DC-sputtering equipment. Surface characteristics of Ti-Zr-N film coated specimens were investigated by OM, XRD, FE-SEM and nano-scratch tester. And corrosion behaviors of the coated specimen were investigated by polarization test and electrochemical impedance spectroscopy(EG&G Co, PARSTAT 2273. USA). It was found that Ti-Zr-N film coated sample had a thick coated layer and showed a good wear resistance and corrosion resistance of surface compared with ZrN and TiN coated sample. The corrosion resistance and mechanical property of Ti-Zr-N film coated STD 61 alloy increased as sputtering time increased.